슈나이더 LXM32MD72N4 서보 드라이브 - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

위챗: +86-13184948252 왓츠앱: 0086-13811255435 이메일: kent@bestcontactor.com

에 대한 연락하다 |

 슈나이더 LXM32MD72N4 서보 드라이브 - 접촉기,회로 차단기,감지기,인코더,PLC,변환기

PLC/전기 같은/

슈나이더 LXM32MD72N4 서보 드라이브

LXM32: Lexium32 series servo M: Multi-fieldbus version (CANopen 지원, built-in encoder acquisition and positioning function) D72: Peak output current 72A, continuous 24A N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply Core Electrical Specifications Item Specification Power Supply 3-phase AC 208~480V, 50/60Hz Rated Power 400V class: 7kW; 230V 클래스: 5kW Continuous Output Current 24A (8kHz carrier ...

  • 제품 세부정보

LXM32: Lexium32 series servo

중: Multi-fieldbus version (CANopen 지원, built-in encoder acquisition and positioning function)

D72: Peak output current 72A, continuous 24A

N4: 3-phase high-voltage model, 208~480VAC 3-phase power supply

핵심 전기 사양

목사양
전원공급장치3-phase AC 208~480V, 50/60헤르츠
정격 출력400V 클래스: 7kW; 230V 클래스: 5kW
Continuous Output Current24에이 (8kHz carrier frequency)
Peak Output Current72에이, sustainable for 5s
내장형 EMC 필터Standard integrated
Speed Loop BandwidthUp to 1600Hz, 높은 동적 응답
캐리어 주파수8kHz
DC Bus Undervoltage Threshold350다섯 (400V 클래스)

의사소통 & 입출력

  1. 필드버스: CANopen (LXM32M model, different from pulse-type LXM32A)
  2. 디지털: Multiple 24VDC discrete inputs including 2 high-speed capture CAP ports; 디지털 출력
  3. 인코더 인터페이스: Supports SinCos and EnDat, compatible with BSH/BMH servo motors
  4. 인터페이스: RJ45 debug port, detachable color-coded terminals for convenient cabinet wiring and maintenance

Matching Motors

Compatible with BSH / BMH 400V class 서보 모터 of Lexium32 series. Typical match: 140-flange BSH high-torque motor, continuous torque up to 27.8N·m, peak 90.2N·m, common speed 3000rpm.

응용 시나리오

포장 기계, machine tool feed axes, CNC cutting, 섬유 기계, material handling conveying, multi-axis synchronization equipment; suitable for automated production lines requiring CANopen bus multi-axis linkage and high dynamic positioning.

설치 & 환경

Book-style cabinet mounting, vertical installation on control cabinet DIN rail

Overvoltage category: 클래스 III

Max leakage current: 30엄마

Recommended wire gauge for power terminals: 3mm², tightening torque 0.5N·m

잘못 & 시운전 참고 사항

  1. Common Alarms: Overcurrent OC, Overvoltage OV, Undervoltage UV, Encoder Fault, Overheat OH
  2. Commissioning Software: 소무브, supports online parameter configuration, oscilloscope sampling and automatic inertia tuning
  3. For high-power working conditions, it is recommended to install an external 1mH line reactor to reduce harmonics and incoming current surges

대사 & Selection Remarks

Pulse version of the same series: LXM32AD72N4 (no CANopen, pulse-direction control)

Upgrade alternative: 슈나이더 Lexium28 series; comparable competitors: Siemens V90, Mitsubishi MR-J4

메모: LXM32 is a discontinued legacy series. Lexium28 is preferred for new projects; stock or second-hand units are available only for spare part projects.

HS Code Reference

85011099 (서보 드라이브, re-verify customs classification before customs declaration)

LXM32MD72N4 SoMove Power-on Commissioning Parameter Template

해당되는: Lexium32M 7kW CANopen bus servo, matched with BSH/BMH 400V motors; SoMove software, expert mode password 696969

Pre-operation: Complete hardware wiring including power cable, 인코더, 비상 정지, 브레이크, CAN bus and 24V control power supply; perform no-load jog test first, then auto-tune under load; save parameters to EEPROM after modification.

  1. 기본 구성 (Simply Start Wizard Page)
매개변수 이름Parameter IDRecommended Setting설명
Control SourceDEVcmdInterf필드버스LXM32M CANopen positioning mode; temporarily change to Terminal for local jog
Motor SelectionMotor SelectionSelect corresponding BSH/BMH modelDrive loads motor nameplate parameters automatically; must not select incorrectly
인코더 유형ENC1_type신코스 / 엔데이트Select according to motor encoder; EnDat absolute encoder requires battery module
캐리어 주파수PWM_Freq8kHzDefault for LXM32MD72N4, not recommended to increase
Rotation DirectionInvertDirOfMove끄다 (기본)Set to ON if rotation direction reversed; power cycle required after change
Auto Enable on Power-upIO_AutoEnable0 (Disabled)Disabled during commissioning; can be set to 2 for mass production after safety assessment
  1. Axis Limit Parameters (Axis Configuration → Limitations)
매개변수 이름Parameter IDRecommended Setting설명
최대 출력 전류CTRL_I_max모터 정격 전류Limit maximum torque to protect machinery; cannot exceed 72A peak of drive
Max Motor SpeedM_n_max모터 정격 속도Typical 3000rpm for BSH/BMH, do not exceed nameplate
Positive Software LimitPOS_LIM_PUser unitInside mechanical hard limit to prevent overtravel
Negative Software LimitPOS_LIM_NUser unitSame as positive limit
E-Stop DecelerationQS_Dec관습Deceleration triggered by emergency stop, safety related
  1. 입출력 & 안전 매개변수 (Axis Configuration → IO)
매개변수 이름Parameter IDRecommended Setting설명
Positive Limit ContactIOsigLIMPNC Normally ClosedDefault for safety standards; set to NO if using normally open sensors
Negative Limit ContactIOsigLIMNNC Normally Closed위와 동일
Brake Release DelayBRK_AddT_Release100msBrake motor: wait for brake release before movement after servo enable
Brake Apply DelayBRK_AddT_Apply50msDelay brake output after servo disable to prevent axis falling
Fault ResetIO_FaultResetAssign DI terminalExternal reset button
  1. Position Scaling (Scaling, Core for Positioning Projects)

User units per revolution, 예: 10mm per revolution for lead screw, modify as required

| 매개변수 이름 | Parameter ID | Example Value | 설명 |

| —| —| —| —|

| Position Numerator | ScalePOSnum | 10 | Numerator of travel per revolution |

| Position Denominator | ScalePOSdenom | 1 | 분모; 예: 10mm/rev → 10/1 |

| Velocity Scaling | ScaleVELnum / ScaleVELdenom | Follow position | Velocity unit: 밀리미터/초 |

| Acceleration Scaling | ScaleACCnum / ScaleACCdenom | Follow position | Acceleration unit: mm/s² |

Raw encoder resolution: 16384count/rev for SinCos motors

  1. Servo Loop Gains (Tuning Page, No-load → On-load Auto-tune)

Prioritize SoMove automatic inertia identification + auto-tune, then fine tune

| 매개변수 이름 | Parameter ID | Initial Recommendation | Tuning Logic |

| —| —| —| —|

| Position Loop Gain | CTRL_Kp_pos | 3~8 | Higher for stiff mechanics; reduce if oscillation occurs |

| Speed Loop Gain | CTRL_Kp_vel | 80~150 | Base response, reduce for mechanical resonance |

| Speed Loop Integral Time | CTRL_Ti_vel | 8~20ms | Smaller value improves steady-state error, prone to oscillation |

| Velocity Feedforward | CTRL_Kff_vel | 0.6~0.9 | Reduce position following error |

| Acceleration Feedforward | CTRL_Kff_acc | 0~0.3 | For high-speed start-stop; large value causes impact |

| Low-pass Filter | CTRL_FiltVel | 500~1000Hz | Suppress resonance; lower filter frequency at resonance point |

  1. CANopen Fieldbus Parameters (Key for LXM32M)
매개변수 이름Parameter IDRecommended Setting설명
CAN Node IDCAN_NodeID1~127No duplicate for multi-axis, consistent with PLC
CAN Baud RateCAN_Baud500kbpsCommon setting; use 250kbps for long distance, terminal resistor ON at both bus ends
PDO MappingPDO ConfigurationStandard positioning PDOTarget position, status word, actual position, fault code
Fieldbus Control ModeProfile ModeProfile Position위치 제어; select Profile Velocity for speed axis
Profile Acc/DecPRO_ACC / PRO_DECMechanical dependent단위: user unit/s
Quick Stop RampPRO_QSDecIndependent E-stop decelerationDeceleration upon bus failure
  1. Homing Parameters
매개변수 이름Parameter ID설명
Homing ModeHOM_mode0~35 optional; 흔한: limit homing, index homing, direct origin setting for absolute encoder
Homing VelocityHOM_VelLow speed, 50~200 user unit/s
Homing Search VelocityHOM_Vel_SearchSlightly higher than homing speed
Homing OffsetHOM_OffsetMechanical origin offset
  1. 모니터링 & Fault Log

Fault Buffer: Stores latest 16 alarms for troubleshooting of OV/OC/OH/ENC faults

오실로스코프: Sample target position, actual position, following error, bus voltage, motor current for resonance and tuning analysis

구하다: Device → User Functions → Save parameters to EEPROM; back up local project as .cxm file

Complete Power-on Commissioning Procedure (Matching Parameter Template)

  1. Connect PC to drive RJ45 debug port via SoMove, establish communication and read factory parameters
  2. Run Simply Start wizard, select motor model and confirm encoder type
  3. Configure limit, brake and I/O terminal definition
  4. Set position scaling and mechanical transmission ratio
  5. Set CANopen Node ID, baud rate and configure PDO
  6. 무부하 테스트: 할 수 있게 하다, 가벼운 흔들림, verify rotation direction, limit and brake logic
  7. On-load test: Run Auto-tune inertia identification to generate base gains
  8. Observe following error and oscillation via oscilloscope, fine-tune 3-loop gains and filter
  9. Homing test, point positioning test, acceleration/deceleration test
  10. Save parameters to EEPROM and export .cxm backup file

Commissioning Precautions

  1. Expert mode password 696969, enter expert mode to modify advanced parameters
  2. Auto-tune must be performed with actual load; parameters tuned under no-load easily oscillate under load
  3. Incorrect brake timing will directly cause axis falling; test brake function without load during first commissioning
  4. CANopen bus: Enable terminal resistor only at the first and last device on bus, disable for intermediate nodes
  5. For high-power LXM32MD72N4, check wiring of line reactor and braking resistor before first power-up

Optional Extended Parameters

제동 저항기: BRK_R, BRK_P for external braking resistor resistance/power rating, bus overvoltage protection

아날로그 입력: AI scaling for analog speed mode (not commonly used for CANopen projects)

Schneider Lexium32 (LXM32) Full Series Drive Model List

3 main branches: LXM32C (Basic Analog) / LXM32A (맥박 + 모드버스) / LXM32M (CANopen bus type, LXM32MD72N4 belongs to this branch)

Suffix explanation:

M2: Single-phase 200~240VAC; N4: 3-phase 208~480VAC

Dxx: Number after D = peak current (에이), continuous current = 1/3 of peak current

상태: Full series discontinued, only available on spare parts market

  1. LXM32M (CANopen Bus Type, High Priority, includes LXM32MD72N4)

Single-phase 200~240V (Suffix M2)

모델피크 전류Continuous Current230V Rated Power
LXM32MD12M212에이4에이0.75kW
LXM32MD18M218에이6에이1.0kW
LXM32MD30M230에이10에이1.6kW
LXM32MD42M242에이14에이2.5kW
LXM32MD57M257에이19에이3.5kW

3-phase 208~480V (Suffix N4, your series)

모델피크 전류Continuous Current400V Rated Power
LXM32MD12N412에이4에이0.9kW
LXM32MD18N418에이6에이1.8kW
LXM32MD30N430에이10에이3kW
LXM32MD42N442에이14에이4.5kW
LXM32MD57N457에이19에이5.5kW
LXM32MD72N472에이24에이7kW
LXM32MD85N485에이32에이9kW
  1. LXM32A (Pulse/Direction + 모드버스, no CANopen, same power rating)

Single-phase M2

LXM32AD12M2, LXM32AD18M2, LXM32AD30M2, LXM32AD42M2, LXM32AD57M2

3-phase N4

LXM32AD12N4, LXM32AD18N4, LXM32AD30N4, LXM32AD42N4, LXM32AD57N4, LXM32AD72N4, LXM32AD85N4

  1. LXM32C (±10V analog basic model, speed/current control only, no positioning)

Single-phase M2

LXM32CD12M2, LXM32CD18M2, LXM32CD30M2, LXM32CD42M2, LXM32CD57M2

3-phase N4

LXM32CD12N4, LXM32CD18N4, LXM32CD30N4, LXM32CD42N4, LXM32CD57N4, LXM32CD72N4, LXM32CD85N4

  1. Matching Motor Series (BSH / BMH for Lexium32)
  2. BSH Motors: SinCos encoder, single-turn/multi-turn, IP50; flange sizes 55/70/100/140mm
  3. BMH Motors: EnDat absolute encoder, 다회전, IP65; flange sizes 55/70/100/140/190mm
  4. 액세서리 목록 (General for LXM32)

VW3M8101: 제동 저항기

VW3M8D10: Encoder battery box (for EnDat multi-turn BMH motors)

VW3M8102: Line reactor

VW3M8200: Pre-made I/O terminal cable

VW3M8300: CANopen bus cable

VW3M8400: Motor power cable

VW3M8500: Encoder cable

Branch Comparison Overview

모델 시리즈제어 인터페이스포지셔닝 기능필드버스일반적인 응용
LXM32C±10V Analog❌ No positioning모드버스Pure speed control
LXM32APulse+Direction✅ Point positioning모드버스Pulse PLC control
LXM32MCANopen✅ Electronic gear / 가리키다 / HomingCANopenMulti-axis bus synchronization (LXM32MD72N4)

선택 팁:

  1. Same Dxx model: LXM32A and LXM32M have identical hardware power rating, differ only in firmware communication functions
  2. LXM32MD85N4 is the largest model in this series, 9kW
  3. New project replacement: Lexium28 series; only stock/second-hand units available for spare part projects.

이전:

다음:

답장을 남겨주세요

메시지를 남겨주세요