Series: HG-KN (Low-inertia compact, for MR-JE drive) | Rated Power: 400W / 0.4kW | Non-brake standard type
HG: Prefix for Mitsubishi AC servo motor
KN: HG-KN low-inertia compact series (MR-JE platform)
43: 400W specification
J: Shaft with keyway, no built-in brake
S100: 17-bit absolute encoder (131072 pulses/rev, compatible with MR-JE)
Brake-equipped variant in the same series: HG-KN43BJ-S100 (B = electromagnetic brake)
✅ Key Electrical Specifications
Rated Power: 400 W
Rated Torque: 1.3 N·m
Maximum Torque: 3.8 N·m
Rated Speed: 3000 r/min
Maximum Speed: 5000 r/min
Supply Voltage: AC200V (single/three-phase 200–240V)
Rated Current: 2.6 A
Encoder: 17-bit absolute
Flange Size: 60×60 mm
Shaft Diameter: φ19mm
Protection Class: IP65 (standard oil seal fitted)
Weight: Approx. 1.8 kg
✅ Compatible Drives (MR-JE only)
MR-JE-40A (Pulse / analog interface)
MR-JE-40B (SSCNETⅢ/H bus)
MR-JE-40C (CC-Link IE Field)
✅ Typical Applications
Conveyor lines, linear transfer modules, engraving machines, packaging machinery, small CNC, point-to-point positioning mechanisms. Suitable for applications requiring fast start-stop response with low inertia.
✅ Spare & Replacement Notes
Not compatible with MR-J4 / MR-JN drives; exclusive to MR-JE series
Domestic alternative references: Delta B3 400W, Inovance IS620 400W low-inertia models
Cables: Power cable + encoder cable, dedicated MR-JE connector, not directly interchangeable with MR-J4
MR-JE Alarm Code List (for HG-KN43J-S100)
Two categories: AL.xx Fault Alarms (machine stop) and E□.x Warnings (no stop). AL alarms require power cycle or software reset; warnings normally clear automatically once root cause is removed.
- AL Fault Alarms (Commonly Used)
| Alarm Code | Alarm Name | Root Cause & Troubleshooting |
| AL.10 | Undervoltage | Low main circuit voltage; phase loss, poor contact of contactor, insufficient power supply capacity, loose wiring |
| AL.12 | RAM Memory Error | Internal drive hardware failure; power cycle first. Repeated alarm → replace drive |
| AL.14 | Control Circuit Error | Internal CPU / control board failure; replace drive if restart ineffective |
| AL.16 | Encoder Initial Communication Error 1 | Loose CN2 encoder cable / connector, EMI interference, encoder damage |
| AL.1E | Encoder Initial Communication Error 2 | Encoder handshake failure on power-up; check cable, shield grounding, motor encoder |
| AL.1F | Encoder Initial Communication Error 3 | Mismatched encoder version / model; HG-KN is dedicated for MR-JE, do not mix other motors |
| AL.20 | Encoder Communication Error 1 | Encoder wire break, poor contact or heavy EMI during operation |
| AL.21 | Encoder Communication Error 2 | Hardware failure of encoder |
| AL.25 | Absolute Position Lost | Dead encoder battery or disconnected battery wire; homing required after reset (frequent alarm for S100 absolute encoder) |
| AL.24 | Main Circuit Fault | Short circuit on U/V/W, motor earth leakage, failed power transistor |
| AL.30 | Regeneration Fault | Fast deceleration, large load inertia; insufficient built-in regenerative resistor, broken resistor, incorrect PA02 parameter |
| AL.31 | Overspeed | Actual speed exceeds limit; excessive electronic gear ratio, abnormal pulse command, encoder fault |
| AL.32 | Overcurrent | U/V/W short circuit, motor insulation breakdown, damaged drive IGBT |
| AL.33 | Overvoltage | DC bus voltage>400V; voltage rise by regenerative energy during deceleration, excessive input voltage |
| AL.35 | Command Pulse Frequency Error | Pulse frequency out of drive limit, wrong pulse wiring mode (differential / open collector) |
| AL.36 | SSCNET Communication Error (JE-B) | Loose / sharply bent fiber optic cable, duplicated station number, bus interference |
| AL.37 | Parameter Error | Parameter out of range or conflicting parameter combination; restore factory settings for test |
| AL.39 | Sequence Program Error (Position Table) | Wrong position table instruction or conflicting parameters |
| AL.45 | Main Circuit Overheat | Poor drive heat dissipation, high ambient temperature, blocked cooling fan |
| AL.46 | Motor Overheat | Overload, continuous stall, brake not released, poor heat dissipation |
| AL.47 | Cooling Fan Fault | Fan stuck or damaged |
| AL.50 | Position Excessive Deviation | Large gap between command and actual position; mechanical jam, insufficient torque, low gain |
| AL.51 | Vibration Detected | Servo vibration / abnormal noise; excessive gain, mechanical resonance |
| AL.61 | Forced Stop Alarm | Emergency stop EMG circuit open (hardware E-stop, immediate shutdown) |
| AL.86 | Network Communication Error (JE-C CC-Link IE) | Faulty Ethernet cable, wrong IP, switch fault, bus disconnection |
- E Warnings (No Shutdown, Display E□.x)
| Warning Code | Warning Name | Description |
| E6.1 | Forced Stop Warning | EMG terminal open warning (not a hard fault; often masked in projects – short EMG on CN1/CN3 or mask by parameter) |
| E8.1 | Homing Incomplete | Absolute encoder without homing after power-up; operation allowed but origin reference lost |
| E9.1 | Battery Warning | Low encoder battery voltage. Replace battery promptly to avoid AL.25 |
| E0.1 | Software Positive Limit | LSP software limit triggered |
| E0.2 | Software Negative Limit | LSN software limit triggered |
- Reset Rules
- AL faults: Remove fault condition then power off & on to reset; some alarms can be cleared via MR Configurator2 software
- E warnings: Clear automatically after condition recovered, power cycle usually unnecessary
- AL.25: Home return must be executed after alarm clearing
- High-Failure Reminders for HG-KN43J-S100
AL.25, E9.1: Absolute encoder battery related – most frequent faults
AL.16/1E/1F/20/21: CN2 encoder cable. Separate power cable and encoder cable routing; single-end shield grounding
AL.46: 400W motor is prone to overheat under heavy load or continuous low-speed operation
Mitsubishi MELSERVO Servo List (Motor + Drive Matching, 200V Mainstream, including HG-KN / MR-JE)
General Suffix Definition
B: Electromagnetic brake; J: Shaft with keyway; S100: 17-bit absolute encoder; S000: Incremental encoder
Drive suffix: A = Pulse / analog; B = SSCNETⅢ/H fiber; C = CC-Link IE Field; G = CC-Link IE TSN (MR-J5)
⚠️ Series incompatibility: MR-JE motor cannot run on MR-J4/J5; MR-J4 motor cannot directly run on MR-J5
- MR-JE Economy Series (matches your HG-KN43J-S100, widely used cost-effective model)
Matched Motors: HG-KN (Low Inertia), HG-SN (Medium Inertia)
MR-JE Drives
MR-JE-10A / 10B / 10C —— 0.1kW
MR-JE-20A / 20B / 20C —— 0.2kW
MR-JE-40A / 40B / 40C —— 0.4kW (for your motor)
MR-JE-60A / 60B / 60C —— 0.6kW
MR-JE-70A / 70B / 70C —— 0.75kW
MR-JE-100A / 100B / 100C —— 1.0kW
MR-JE-200A / 200B / 200C —— 2.0kW
MR-JE-300A / 300B / 300C —— 3.0kW
HG-KN Motors (Low Inertia, 3000rpm)
HG-KN13J-S100 (0.1kW), HG-KN23J-S100 (0.2kW), HG-KN43J-S100 (0.4kW), HG-KN63J-S100 (0.6kW), HG-KN73J-S100 (0.75kW), HG-KN102J-S100 (1.0kW), HG-KN202J-S100 (2.0kW), HG-KN302J-S100 (3.0kW)
Brake version: HG-KN□□BJ-S100
HG-SN Motors (Medium Inertia, for fluctuating loads)
HG-SN102J-S100 (1.0kW), HG-SN202J-S100 (2.0kW), HG-SN302J-S100 (3.0kW)
Brake version: HG-SN□□BJ-S100
- MR-J4 High-Performance Series (Large installed base for legacy machines)
Matched Motors: HG-KR, HG-MR, HG-SR, HG-RR, HG-JR
MR-J4 Drives
MR-J4-10A/B/GF — 0.1kW
MR-J4-20A/B/GF — 0.2kW
MR-J4-40A/B/GF — 0.4kW
MR-J4-60A/B/GF — 0.6kW
MR-J4-70A/B/GF — 0.75kW
MR-J4-100A/B/GF — 1.0kW
MR-J4-200A/B/GF — 2.0kW
MR-J4-350A/B/GF — 3.5kW
MR-J4-500A/B/GF — 5.0kW
MR-J4-700A/B/GF — 7.0kW
Multi-axis drives: MR-J4W2-22B, MR-J4W2-44B (2-axis); MR-J4W3-222B (3-axis)
MR-J4 Motor Lineup
- HG-KR: Small low-inertia 50W~750W (HG-KR053, HG-KR13, HG-KR23, HG-KR43, HG-KR73)
- HG-MR: Ultra-low inertia for frequent start-stop 50W~750W (HG-MR053,13,23,43,73)
- HG-SR: Medium inertia 0.5~7kW (HG-SR52,102,152,202,352,502,702)
- HG-RR: Medium capacity ultra-low inertia 1~5kW (HG-RR103,153,203,353,503)
- HG-JR: Large low-inertia 0.5~55kW (Mainly for machine tools, printing, injection molding)
- MR-J5 New Flagship Series (CC-Link IE TSN, new project replacement for MR-J4)
Matched Motors: HK-KT (Low inertia, replace HG-KR/KN), HK-RT (Medium inertia, replace HG-SR)
MR-J5 Drives
MR-J5-10A/B/G — 0.1kW
MR-J5-20A/B/G — 0.2kW
MR-J5-40A/B/G — 0.4kW
MR-J5-60A/B/G — 0.6kW
MR-J5-70A/B/G — 0.75kW
MR-J5-100A/B/G — 1.0kW
MR-J5-200A/B/G — 2.0kW
MR-J5-350A/B/G — 3.5kW
MR-J5-500A/B/G — 5.0kW
MR-J5-700A/B/G — 7.0kW
Multi-axis drives: MR-J5W2-G, MR-J5W3-G (2-axis / 3-axis, wiring saving)
MR-J5 Motors
HK-KT Low Inertia: HK-KT053W,13W,23W,43W,73W
HK-RT Medium Inertia: HK-RT103W,153W,203W,353W,503W,703W
- Discontinued Legacy Series (Spare parts & maintenance only, not recommended for new projects)
- MR-J3 + HF-KP / HF-SP (Largest legacy stock, phasing out)
- MR-E / MR-ES + HF-KN / HF-SN (Earlier economy type, incompatible with HG-KN)
- MR-J2S (Very old generation)
- Quick Selection Summary Table
| Drive Series | Positioning | Matched Motor | Bus Interface |
| MR-JE | Economy, cost-effective | HG-KN / HG-SN | Pulse / SSCNETⅢ/H / CC-Link IE Field |
| MR-J4 | General high-performance (legacy stock) | HG-KR/MR/SR/RR/JR | Pulse / SSCNETⅢ/H / CC-Link IE Field |
| MR-J5 | New flagship for new projects | HK-KT / HK-RT | Pulse / SSCNETⅢ/H / CC-Link IE TSN |
- Supplementary Notes
- 400V high-voltage versions: MR-J4(-4), MR-J5(-4), with corresponding high-voltage motors, generally used above 7kW
- Special types: LM linear motors, TM-RG/TM-RU torque direct-drive motors, selected separately
- Cable incompatibility: MR-JE, MR-J4, MR-J5 encoder connectors & pin assignments differ and cannot be swapped directly
Contactor,circuit breaker,sensor,Encoder,PLC,Converter






















NH42-63-318x560.png)