Full Model: NBB20-L2-A2-V1
Product Category: Square Inductive Proximity Sensor (VariKont L Series)
Core Specifications
| Item | Parameter |
| Order No. | 187548 |
| Rated Sensing Distance Sn | 20 mm, Flush Mountable |
| Output Type | 4-wire DC, PNP Complementary Output (NO+NC) |
| Supply Voltage | 10 … 30 V DC |
| Connection | M12 4-pin Male Connector |
| Switching Frequency | 440 Hz |
| Ingress Protection | IP68 / IP69K |
| Housing Material | PA (Polyamide / Nylon) |
| Overall Dimension | 40 × 40 × 67 mm |
| Operating Temperature | -25 ℃ ~ +85 ℃ |
| Features | Rotatable sensing head; 4 LEDs for 360° status visibility; Quick-mount bracket included |
Pin Assignment (M12 4-pin)
- BN Brown: +Vcc
- WH White: NC Normally Closed
- BU Blue: 0V/GND
- BK Black: NO Normally Open
Features & Applications
Square housing with long sensing distance, flush mount design for metal target detection
Built-in reverse polarity protection and short-circuit protection; suitable for machine tools, conveyor lines, workpiece counting and position detection
Sensing distance derating for non-ferrous metals: Aluminium 0.33, Copper 0.31
Replacement Reference
Compare with same series: NBB20-L2-E2-V1 (NPN version); Cable version: NBB20-L2-A2
Product Type: Square Inductive Proximity Sensor, Order No. 187548
- Product Overview
Model: NBB20-L2-A2-V1, Order No.: 187548
Sensing Distance: Sn=20 mm, Flush Mountable
Output: 4-wire DC, PNP complementary (NO + NC)
Sensing Head: Rotatable, 4 LEDs for 360° visual status indication
Included Accessories: Quick-mount bracket
Protection Rating: IP68 / IP69K, PA nylon housing
- Installation Requirements【Important】
- Flush Mount Definition: The sensing face must be level with the metal mounting surface; surrounding metal must not protrude above the sensing face. This model is designed for flush mounting only, do not install as non-flush.
- Minimum Spacing Between Sensors
Side-by-side installation of identical sensors: Centre distance ≥ 40 mm
Face-to-face installation: Distance ≥ 60 mm to prevent mutual interference
- Metal Clearance Requirements
Rear metal backplate: Thickness ≥1 mm, extending at least 10 mm beyond the sensor outline
Side metal adjacent to sensing face: Minimum clearance ≥10 mm; nearby metal will reduce sensing range and cause false triggering
- Target Specs: Standard test target: 40×40×1 mm mild steel. Effective sensing distance for aluminium, copper and 304 stainless steel needs to be multiplied by derating factor
Aluminium Al: 0.33
Copper Cu: 0.31
304 Stainless Steel: 0.74
- Mounting Bracket: Use original quick-mount bracket. Recommended tightening torque for mounting screws: 0.8 ~ 1.2 N·m. Do not over-tighten to avoid cracking PA housing.
- Sensing Head Adjustment: Loosen the head fixing screw to rotate the sensing face, retighten after alignment; do not force rotation.
- Dimension (40×40 Square Housing)
Overall size: 40 mm (W) × 40 mm (H) × 67 mm (L)
Sensing face: 40×40 mm square
Connector: M12×1 4-pin male
Weight: Approx. 155 g
- Wiring Definition (EN60947-5-2)
| Pin No. | Colour | Definition |
| 1 | BN Brown | DC + 10~30V |
| 2 | WH White | NC Normally Closed (PNP) |
| 3 | BU Blue | 0V / GND |
| 4 | BK Black | NO Normally Open (PNP) |
Note: PNP output; load is connected between signal wire and 0V. Built-in reverse polarity protection and pulsed short-circuit protection. Max output current per channel: 200 mA.
- LED Indication
Power LED: Steady ON = Power supply OK; OFF = No power / Reverse polarity
Switch LED: Metal target enters reliable sensing range (0~16.2 mm) → output state toggles, corresponding LED illuminates
4-side LED design, status visible from any angle
Usable operating range Sa: 0 ~ 16.2 mm (guaranteed stable switching range); Sr typical switching range 18~22 mm
- Electrical Installation Guidelines
- Power Supply: DC 10 ~ 30 V, regulated DC supply recommended, ripple <10%
- Cables: Shielded or unshielded cables for M12 connection; use shielded cable for cable length >10 m, single-end grounding for shield
- Cable Routing: Separate from power cables (inverter, motor cables) to avoid strong electromagnetic interference
- Switching Frequency: 440 Hz, do not exceed this limit for high-speed counting applications
- Hysteresis: Typically ~5% of rated sensing distance, prevents chattering caused by minor target vibration
- Mechanical & Environmental Specifications
Operating Temperature: -25 ℃ ~ +85 ℃
Storage Temperature: -40 ℃ ~ +85 ℃
IP68/IP69K: High-pressure washdown compatible; ensure connector fully locked and seal intact
Prohibited: Impact on sensing face, welding near sensor, long-term use in strong acid/alkali environments
- Commissioning Procedure
- Secure sensor with mounting bracket and adjust sensing face orientation
- Mate M12 connector, verify wiring sequence and power on
- Slowly move standard metal target towards the sensing face
- Confirm reliable output switching and LED activation within 0~16.2 mm
- Lock target trigger position and repeat multiple tests; no chattering = acceptable
- Troubleshooting
| Symptom | Check Items |
| No LED after power on | Supply voltage, polarity, loose pins in M12 connector |
| No detection signal | Metal target derating factor, adjacent metal interference, out of Sa reliable range |
| Signal flickering | EMI from power cables, loose mounting, thin target, high supply ripple |
| Output cannot reset | Short circuit, leakage load, signal wire shorted to 24V |
- Safety Notes
This sensor is NOT a safety-rated sensor, must not be used in safety circuits (E-stop, safety gate)
Isolate power before maintenance; avoid frequent hot-plugging of M12 connector (hot swapping may damage contacts)
UL approval: Class 2 circuit supply, max 60VDC, 200mA load
Pepperl+Fuchs Square Inductive Proximity Sensor List (VariKont L2 / U / F Series)
Note: Series includes VariKont L2 (40×40, the series of 187548), VariKont U and compact F series. Sn = Rated sensing distance. F=Flush, NF=Non-flush. E2=PNP NO, E0=NPN NO, A2=PNP complementary NO+NC, A0=NPN complementary NO+NC. V1=M12 connector; no V suffix = fixed cable.
- VariKont L2 40×40 (Mainstream, Rotatable Sensing Head, IP68/IP69K)
| Model | Order No. | Sn | Mount | Output | Connection |
| NBB20-L2-A2-V1 | 187548 | 20 mm | Flush F | PNP 4-wire Complementary NO+NC | M12 4-pin Male |
| NBB20-L2-E2-V1 | 187549 | 20 mm | Flush F | PNP 3-wire NO | M12 3-pin Male |
| NBB20-L2-A0-V1 | 187550 | 20 mm | Flush F | NPN 4-wire Complementary NO+NC | M12 4-pin Male |
| NBB20-L2-E0-V1 | 187551 | 20 mm | Flush F | NPN 3-wire NO | M12 3-pin Male |
| NBN40-L2-A2-V1 | 187552 | 40 mm | Non-flush NF | PNP 4-wire Complementary NO+NC | M12 4-pin Male |
| NBN40-L2-E2-V1 | 187553 | 40 mm | Non-flush NF | PNP 3-wire NO | M12 3-pin Male |
| NBN40-L2-A0-V1 | 187554 | 40 mm | Non-flush NF | NPN 4-wire Complementary NO+NC | M12 4-pin Male |
| NBN40-L2-E0-V1 | 187555 | 40 mm | Non-flush NF | NPN 3-wire NO | M12 3-pin Male |
| NBN40-L2M-E2-V1 | 132360 | 40 mm | Non-flush NF | PNP 3-wire NO | M12 3-pin Male |
- VariKont U 40×40 (Older Version, Terminal / Cable Type)
| Model | Order No. | Sn | Mount | Output | Connection |
| NBB20-U1-A2 | 87231 | 20 mm | Flush F | PNP 4-wire Complementary | 2m Fixed Cable |
| NBB20-U1-E2 | 87232 | 20 mm | Flush F | PNP 3-wire NO | 2m Fixed Cable |
| NBB20-U2-A2 | 87233 | 20 mm | Flush F | PNP 4-wire Complementary | Terminal Block |
| NBB20-U4-UU | 248043 | 20 mm | Flush F | AC/DC 2-wire | 陆NPT |
| NBN40-U1-E2 | 87234 | 40 mm | Non-flush NF | PNP 3-wire NO | 2m Fixed Cable |
| NBN40-U4K-N0-V1 | 103753 | 40 mm | Non-flush NF | NAMUR | M12 Connector |
| NBB15-U1-A2 | 124008 | 15 mm | Flush F | PNP 4-wire Complementary | Cable |
- Compact F Series (F1/F10/F11/F33/F41/F79)
| Model | Order No. | Sn | Mount | Output | Connection |
| NBN8-F1-E2 | 84012 | 8 mm | Non-flush NF | PNP NO | 2m Cable |
| NBN8-F1-A2-V31 | 84014 | 8 mm | Non-flush NF | PNP Complementary | M8 Connector |
| NBB1,5-F41-E2 | 84001 | 1.5 mm | Flush F | PNP NO | 2m Cable |
| NBB1,5-F41-E2-V3 | 84002 | 1.5 mm | Flush F | PNP NO | M8 Connector |
| NBB4-F10-E2 | 84005 | 4 mm | Flush F | PNP NO | 2m Cable |
| NBB5-F11-E2 | 84008 | 5 mm | Flush F | PNP NO | 2m Cable |
| NBB3-F33-E2 | 84018 | 3 mm | Flush F | PNP NO | 2m Cable |
| NBB0,8-F79-E2 | 84022 | 0.8 mm | Flush F | PNP NO | Cable |
- FP Large Square Series (55×55, Long Sensing Range)
| Model | Order No. | Sn | Mount | Output | Connection |
| NBB50-FP-E2 | 87240 | 50 mm | Flush F | PNP NO | Cable / Terminal |
| NBN80-FP-E2 | 87241 | 80 mm | Non-flush NF | PNP NO | Cable / Terminal |
Model Naming Rule
- NBB: Shielded (Flush mountable); NBN: Unshielded (Non-flush only)
- Number: Rated sensing distance Sn (mm)
- L2 = New 40×40 L2 series with rotatable head; U = Older VariKont U; F = Compact F housing; FP = Large square FP housing
- A2: PNP 4-wire complementary (NO+NC); A0: NPN 4-wire complementary; E2: PNP 3-wire NO; E0: NPN 3-wire NO; E1: NC
- V1: M12 connector; V3: M8 connector; No suffix = Fixed PVC cable; UU = AC/DC 2-wire; K = NAMUR Intrinsically Safe
Additional Notes
This list covers mainstream standard stock models, excluding high-temperature, explosion-proof, custom IO-Link variants
Different suffixes correspond to unique order numbers and cannot be interchanged
Standard derating reference: Aluminium ≈0.33, Copper ≈0.31, 304 Stainless Steel ≈0.74
Working Principle of Inductive Proximity Sensor
Pepperl+Fuchs inductive proximity sensors operate on the eddy current effect. They detect metal targets only and cannot sense plastic, wood, water or glass.
Main Internal Components
- LC Oscillator Circuit (Coil + Capacitor): Generates high-frequency alternating magnetic field (typically hundreds of kHz)
- Sensing Coil: Emits alternating magnetic field from the sensing face
- Signal Processing Circuit: Amplitude detection, comparison and signal conditioning
- Output Driver Stage: PNP / NPN / NAMUR etc.
Working Sequence
- After power-up, the LC oscillator starts oscillating, and the coil emits high-frequency alternating magnetic field
- No metal nearby: Low magnetic energy loss, oscillation is maintained, output stays in original state
- Metal target enters magnetic field: Alternating field penetrates the metal surface and induces eddy currents inside the metal
- Eddy currents generate opposing magnetic field, counteracting the original field and consuming oscillation energy, resulting in reduced oscillation amplitude or oscillation halt
- Post-processing circuit detects amplitude change, triggers hysteresis comparison and toggles output state (NO/NC on or off)
- Metal moves away → eddy current disappears → oscillation recovers → output resets
Summary: Inductive sensors detect metal presence by measuring energy loss caused by eddy currents induced in metal within an alternating magnetic field.
Key Feature Explanation (Matching Pepperl+Fuchs Square Sensors)
NBB (Shielded / Flush Mountable): Shield ring around the coil concentrates magnetic field forward with minimal side emission. Can be embedded into metal mounting plate without false triggering
NBN (Unshielded / Non-flush): No shielding ring, magnetic field radiates outward in all directions. Cannot be embedded into metal, otherwise it will continuously detect the mounting metal and false trigger
Sensing Distance Derating: Eddy current strength varies with metal conductivity. Detection capability: Steel Stainless Steel Aluminium Copper, so effective range decreases for aluminium and copper
Hysteresis: Difference between switch-on distance and switch-off distance. Eliminates output chattering caused by minor target vibration
Metal-only detection: Non-metallic materials do not generate eddy current and will not trigger the sensor
Quick Comparison
Inductive: Metal-only, eddy current principle
Capacitive: Detect metal, plastic, liquid, based on electric field change
Photoelectric: Operate via light emission/reception, mostly unaffected by material (except opaque/transparent objects)
Contactor,circuit breaker,sensor,Encoder,PLC,Converter


















NH42-63-318x560.png)