Full Model: NBB20-L2-A2-V1 Product Category: Square Inductive Proximity Sensor (VariKont L Series) Core Specifications Item Parameter Order No. 187548 Rated Sensing Distance Sn 20 mm, Flush Mountable Output Type 4-wire DC, PNP Complementary Output (NO+NC) Supply Voltage 10 … 30 V DC Connection M12 4-pin Male Connector Switching Frequency 440 Hz Ingress Protection IP68 / ...

  • Product Details

Full Model: NBB20-L2-A2-V1

Product Category: Square Inductive Proximity Sensor (VariKont L Series)

Core Specifications

ItemParameter
Order No.187548
Rated Sensing Distance Sn20 mm, Flush Mountable
Output Type4-wire DC, PNP Complementary Output (NO+NC)
Supply Voltage10 … 30 V DC
ConnectionM12 4-pin Male Connector
Switching Frequency440 Hz
Ingress ProtectionIP68 / IP69K
Housing MaterialPA (Polyamide / Nylon)
Overall Dimension40 × 40 × 67 mm
Operating Temperature-25 ℃ ~ +85 ℃
FeaturesRotatable sensing head; 4 LEDs for 360° status visibility; Quick-mount bracket included

Pin Assignment (M12 4-pin)

  1. BN Brown: +Vcc
  2. WH White: NC Normally Closed
  3. BU Blue: 0V/GND
  4. BK Black: NO Normally Open

Features & Applications

Square housing with long sensing distance, flush mount design for metal target detection

Built-in reverse polarity protection and short-circuit protection; suitable for machine tools, conveyor lines, workpiece counting and position detection

Sensing distance derating for non-ferrous metals: Aluminium 0.33, Copper 0.31

Replacement Reference

Compare with same series: NBB20-L2-E2-V1 (NPN version); Cable version: NBB20-L2-A2

Product Type: Square Inductive Proximity Sensor, Order No. 187548

  1. Product Overview

Model: NBB20-L2-A2-V1, Order No.: 187548

Sensing Distance: Sn=20 mm, Flush Mountable

Output: 4-wire DC, PNP complementary (NO + NC)

Sensing Head: Rotatable, 4 LEDs for 360° visual status indication

Included Accessories: Quick-mount bracket

Protection Rating: IP68 / IP69K, PA nylon housing

  1. Installation Requirements【Important】
  2. Flush Mount Definition: The sensing face must be level with the metal mounting surface; surrounding metal must not protrude above the sensing face. This model is designed for flush mounting only, do not install as non-flush.
  3. Minimum Spacing Between Sensors

Side-by-side installation of identical sensors: Centre distance ≥ 40 mm

Face-to-face installation: Distance ≥ 60 mm to prevent mutual interference

  1. Metal Clearance Requirements

Rear metal backplate: Thickness ≥1 mm, extending at least 10 mm beyond the sensor outline

Side metal adjacent to sensing face: Minimum clearance ≥10 mm; nearby metal will reduce sensing range and cause false triggering

  1. Target Specs: Standard test target: 40×40×1 mm mild steel. Effective sensing distance for aluminium, copper and 304 stainless steel needs to be multiplied by derating factor

Aluminium Al: 0.33

Copper Cu: 0.31

304 Stainless Steel: 0.74

  1. Mounting Bracket: Use original quick-mount bracket. Recommended tightening torque for mounting screws: 0.8 ~ 1.2 N·m. Do not over-tighten to avoid cracking PA housing.
  2. Sensing Head Adjustment: Loosen the head fixing screw to rotate the sensing face, retighten after alignment; do not force rotation.
  3. Dimension (40×40 Square Housing)

Overall size: 40 mm (W) × 40 mm (H) × 67 mm (L)

Sensing face: 40×40 mm square

Connector: M12×1 4-pin male

Weight: Approx. 155 g

  1. Wiring Definition (EN60947-5-2)
Pin No.ColourDefinition
1BN BrownDC + 10~30V
2WH WhiteNC Normally Closed (PNP)
3BU Blue0V / GND
4BK BlackNO Normally Open (PNP)

Note: PNP output; load is connected between signal wire and 0V. Built-in reverse polarity protection and pulsed short-circuit protection. Max output current per channel: 200 mA.

  1. LED Indication

Power LED: Steady ON = Power supply OK; OFF = No power / Reverse polarity

Switch LED: Metal target enters reliable sensing range (0~16.2 mm) → output state toggles, corresponding LED illuminates

4-side LED design, status visible from any angle

Usable operating range Sa: 0 ~ 16.2 mm (guaranteed stable switching range); Sr typical switching range 18~22 mm

  1. Electrical Installation Guidelines
  2. Power Supply: DC 10 ~ 30 V, regulated DC supply recommended, ripple <10%
  3. Cables: Shielded or unshielded cables for M12 connection; use shielded cable for cable length >10 m, single-end grounding for shield
  4. Cable Routing: Separate from power cables (inverter, motor cables) to avoid strong electromagnetic interference
  5. Switching Frequency: 440 Hz, do not exceed this limit for high-speed counting applications
  6. Hysteresis: Typically ~5% of rated sensing distance, prevents chattering caused by minor target vibration
  7. Mechanical & Environmental Specifications

Operating Temperature: -25 ℃ ~ +85 ℃

Storage Temperature: -40 ℃ ~ +85 ℃

IP68/IP69K: High-pressure washdown compatible; ensure connector fully locked and seal intact

Prohibited: Impact on sensing face, welding near sensor, long-term use in strong acid/alkali environments

  1. Commissioning Procedure
  2. Secure sensor with mounting bracket and adjust sensing face orientation
  3. Mate M12 connector, verify wiring sequence and power on
  4. Slowly move standard metal target towards the sensing face
  5. Confirm reliable output switching and LED activation within 0~16.2 mm
  6. Lock target trigger position and repeat multiple tests; no chattering = acceptable
  7. Troubleshooting
SymptomCheck Items
No LED after power onSupply voltage, polarity, loose pins in M12 connector
No detection signalMetal target derating factor, adjacent metal interference, out of Sa reliable range
Signal flickeringEMI from power cables, loose mounting, thin target, high supply ripple
Output cannot resetShort circuit, leakage load, signal wire shorted to 24V
  1. Safety Notes

This sensor is NOT a safety-rated sensor, must not be used in safety circuits (E-stop, safety gate)

Isolate power before maintenance; avoid frequent hot-plugging of M12 connector (hot swapping may damage contacts)

UL approval: Class 2 circuit supply, max 60VDC, 200mA load

Pepperl+Fuchs Square Inductive Proximity Sensor List (VariKont L2 / U / F Series)

Note: Series includes VariKont L2 (40×40, the series of 187548), VariKont U and compact F series. Sn = Rated sensing distance. F=Flush, NF=Non-flush. E2=PNP NO, E0=NPN NO, A2=PNP complementary NO+NC, A0=NPN complementary NO+NC. V1=M12 connector; no V suffix = fixed cable.

  1. VariKont L2 40×40 (Mainstream, Rotatable Sensing Head, IP68/IP69K)
ModelOrder No.SnMountOutputConnection
NBB20-L2-A2-V118754820 mmFlush FPNP 4-wire Complementary NO+NCM12 4-pin Male
NBB20-L2-E2-V118754920 mmFlush FPNP 3-wire NOM12 3-pin Male
NBB20-L2-A0-V118755020 mmFlush FNPN 4-wire Complementary NO+NCM12 4-pin Male
NBB20-L2-E0-V118755120 mmFlush FNPN 3-wire NOM12 3-pin Male
NBN40-L2-A2-V118755240 mmNon-flush NFPNP 4-wire Complementary NO+NCM12 4-pin Male
NBN40-L2-E2-V118755340 mmNon-flush NFPNP 3-wire NOM12 3-pin Male
NBN40-L2-A0-V118755440 mmNon-flush NFNPN 4-wire Complementary NO+NCM12 4-pin Male
NBN40-L2-E0-V118755540 mmNon-flush NFNPN 3-wire NOM12 3-pin Male
NBN40-L2M-E2-V113236040 mmNon-flush NFPNP 3-wire NOM12 3-pin Male
  1. VariKont U 40×40 (Older Version, Terminal / Cable Type)
ModelOrder No.SnMountOutputConnection
NBB20-U1-A28723120 mmFlush FPNP 4-wire Complementary2m Fixed Cable
NBB20-U1-E28723220 mmFlush FPNP 3-wire NO2m Fixed Cable
NBB20-U2-A28723320 mmFlush FPNP 4-wire ComplementaryTerminal Block
NBB20-U4-UU24804320 mmFlush FAC/DC 2-wire陆NPT
NBN40-U1-E28723440 mmNon-flush NFPNP 3-wire NO2m Fixed Cable
NBN40-U4K-N0-V110375340 mmNon-flush NFNAMURM12 Connector
NBB15-U1-A212400815 mmFlush FPNP 4-wire ComplementaryCable
  1. Compact F Series (F1/F10/F11/F33/F41/F79)
ModelOrder No.SnMountOutputConnection
NBN8-F1-E2840128 mmNon-flush NFPNP NO2m Cable
NBN8-F1-A2-V31840148 mmNon-flush NFPNP ComplementaryM8 Connector
NBB1,5-F41-E2840011.5 mmFlush FPNP NO2m Cable
NBB1,5-F41-E2-V3840021.5 mmFlush FPNP NOM8 Connector
NBB4-F10-E2840054 mmFlush FPNP NO2m Cable
NBB5-F11-E2840085 mmFlush FPNP NO2m Cable
NBB3-F33-E2840183 mmFlush FPNP NO2m Cable
NBB0,8-F79-E2840220.8 mmFlush FPNP NOCable
  1. FP Large Square Series (55×55, Long Sensing Range)
ModelOrder No.SnMountOutputConnection
NBB50-FP-E28724050 mmFlush FPNP NOCable / Terminal
NBN80-FP-E28724180 mmNon-flush NFPNP NOCable / Terminal

Model Naming Rule

  1. NBB: Shielded (Flush mountable); NBN: Unshielded (Non-flush only)
  2. Number: Rated sensing distance Sn (mm)
  3. L2 = New 40×40 L2 series with rotatable head; U = Older VariKont U; F = Compact F housing; FP = Large square FP housing
  4. A2: PNP 4-wire complementary (NO+NC); A0: NPN 4-wire complementary; E2: PNP 3-wire NO; E0: NPN 3-wire NO; E1: NC
  5. V1: M12 connector; V3: M8 connector; No suffix = Fixed PVC cable; UU = AC/DC 2-wire; K = NAMUR Intrinsically Safe

Additional Notes

This list covers mainstream standard stock models, excluding high-temperature, explosion-proof, custom IO-Link variants

Different suffixes correspond to unique order numbers and cannot be interchanged

Standard derating reference: Aluminium ≈0.33, Copper ≈0.31, 304 Stainless Steel ≈0.74

Working Principle of Inductive Proximity Sensor

Pepperl+Fuchs inductive proximity sensors operate on the eddy current effect. They detect metal targets only and cannot sense plastic, wood, water or glass.

Main Internal Components

  1. LC Oscillator Circuit (Coil + Capacitor): Generates high-frequency alternating magnetic field (typically hundreds of kHz)
  2. Sensing Coil: Emits alternating magnetic field from the sensing face
  3. Signal Processing Circuit: Amplitude detection, comparison and signal conditioning
  4. Output Driver Stage: PNP / NPN / NAMUR etc.

Working Sequence

  1. After power-up, the LC oscillator starts oscillating, and the coil emits high-frequency alternating magnetic field
  2. No metal nearby: Low magnetic energy loss, oscillation is maintained, output stays in original state
  3. Metal target enters magnetic field: Alternating field penetrates the metal surface and induces eddy currents inside the metal
  4. Eddy currents generate opposing magnetic field, counteracting the original field and consuming oscillation energy, resulting in reduced oscillation amplitude or oscillation halt
  5. Post-processing circuit detects amplitude change, triggers hysteresis comparison and toggles output state (NO/NC on or off)
  6. Metal moves away → eddy current disappears → oscillation recovers → output resets

Summary: Inductive sensors detect metal presence by measuring energy loss caused by eddy currents induced in metal within an alternating magnetic field.

Key Feature Explanation (Matching Pepperl+Fuchs Square Sensors)

NBB (Shielded / Flush Mountable): Shield ring around the coil concentrates magnetic field forward with minimal side emission. Can be embedded into metal mounting plate without false triggering

NBN (Unshielded / Non-flush): No shielding ring, magnetic field radiates outward in all directions. Cannot be embedded into metal, otherwise it will continuously detect the mounting metal and false trigger

Sensing Distance Derating: Eddy current strength varies with metal conductivity. Detection capability: Steel Stainless Steel Aluminium Copper, so effective range decreases for aluminium and copper

Hysteresis: Difference between switch-on distance and switch-off distance. Eliminates output chattering caused by minor target vibration

Metal-only detection: Non-metallic materials do not generate eddy current and will not trigger the sensor

Quick Comparison

Inductive: Metal-only, eddy current principle

Capacitive: Detect metal, plastic, liquid, based on electric field change

Photoelectric: Operate via light emission/reception, mostly unaffected by material (except opaque/transparent objects)