Phoenix Contact MINI MCR-SL-UI-2I Analog Signal Duplicator - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

Phoenix Contact MINI MCR-SL-UI-2I Analog Signal Duplicator - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

PLC/

Phoenix Contact MINI MCR-SL-UI-2I Analog Signal Duplicator

Order No.: 2864794, Replacement Model: 2905025 MINI MCR-2-UNI-UI-2UI-C Type: 4-way isolated analog signal duplicator / isolation amplifier (screw connection, custom configuration version) Core Function It accepts 1 channel of standard analog input signal and replicates it into 2 mutually independent current outputs after galvanic isolation. It realizes signal isolation, conversion, amplification, filtering and 1-in-2-out signal ...

  • Product Details

Order No.: 2864794, Replacement Model: 2905025 MINI MCR-2-UNI-UI-2UI-C

Type: 4-way isolated analog signal duplicator / isolation amplifier (screw connection, custom configuration version)

Core Function

It accepts 1 channel of standard analog input signal and replicates it into 2 mutually independent current outputs after galvanic isolation. It realizes signal isolation, conversion, amplification, filtering and 1-in-2-out signal duplication. The measuring range is configured via DIP switches, with 4-way isolation (input / output 1 / output 2 / power supply isolated from each other).

Suitable for splitting transmitter signals to PLC + paperless recorder, anti-interference isolation and instrument loop distribution.

📌 Key Electrical Specifications

Power supply: 19.2–30 VDC, nominal 24VDC; power consumption <600mW, current <30mA @24V (including load)

Input (selectable via DIP switch): 0…20mA / 4…20mA / 0…10V / 1…5V

Input impedance for voltage signal ≈100kΩ; input impedance for current signal ≈50Ω

Output: 2 independent current outputs, 0…20mA /4…20mA; max. output ≈22mA; load ≤250Ω@20mA

Accuracy: Max. transmission error ≤0.2%FS, typical <0.1%FS; temperature drift <0.01%/K

Bandwidth (-3dB): ≈35Hz; step response (0–99%) ≈10ms

Isolation test voltage: 1.5kV AC 60s between input, output and power supply, basic insulation per EN61010

Protection class: IP20; operating temperature -20 ~ +60℃, storage temperature -40~85℃, non-condensing

📐 Mechanical Data

Mounting: 35mm DIN rail (EN60715), any mounting orientation

Width: 6.2 mm (ultra-slim design for dense installation); 93.1(H) ×102.5(D) mm

Connection: M3 screw terminals, conductor 0.2–2.5mm² (AWG26–12), stripping length 12mm

Housing: PBT, RAL6021 green; net weight 73.3g, gross weight 89.7g

📋 Certifications

CE, UL508, Class I Div.2, GL marine approval, II 3G Ex nA IIC T4 Gc X (explosion protection)

🧩 Series Identification & Spare Parts

2864794: MINI MCR-SL-UI-2I made-to-order configuration, non-returnable

2864176: MINI MCR-SL-UI-2I-NC standard pre-configured version

2864804: MINI MCR-SL-UI-2I-SP special version

Matching bus base: 2869728 ME 6,2 TBUS-2 (DIN rail power bus connector)

Matching power terminal: 2864134 MINI MCR-SL-PTB

The original part number 2864794 is no longer available for regular supply. For new projects, use the replacement 2905025 MINI MCR-2-UNI-UI-2UI-C (new-generation MINI MCR-2 series, fully compatible with upgraded performance).

Application Scenarios for 2864794 (MINI MCR-SL-UI-2I)

Core positioning: 1 analog input, galvanically isolated duplication into 2 independent 4/0–20mA current signals, 4-way isolation (Input / Out1 / Out2 / Power), signal conversion + noise immunity. Ultra-slim 6.2mm width for dense cabinet layout, certified for installation in Zone 2 hazardous areas.

  1. Split One Sensor Signal into Two Outputs (Most Common Use Case)
  2. PLC + Paperless Recorder / Data Logger

Pressure, temperature, level and flow transmitters with only one 4–20mA output can feed the PLC for control meanwhile send a copy to the recorder for data archiving and traceability. The two outputs are galvanically isolated; a fault on the recorder side will not drag down the transmitter loop or affect control.

  1. DCS Main System + Independent SIS Safety Interlock

One process measurement point sends one signal to DCS for monitoring and the isolated second signal to the independent SIS safety loop. Physical signal separation meets the independence requirement for functional safety.

  1. Dual PLC / Dual Controller Redundant Acquisition

Primary and backup controllers acquire the same field instrument signal at the same time. Isolated dual outputs prevent cross-interference caused by ground potential difference between controllers.

  1. SCADA Host Collection + Local HMI / Secondary Indicator

One channel feeds the PLC for SCADA upload, the other goes to local digital indicator or analog pointer meter for on-site display.

Input compatibility: 0/4–20mA, 0–10V, 1–5V; both outputs are current-only (0/4–20mA). Measuring ranges are freely combined via DIP switches.

  1. Ground Loop Elimination & Noise Isolation

When transmitters are installed near high-power motors, frequency converters or medium-frequency furnaces, long cable runs introduce ground potential difference and common-mode interference, resulting in signal jumping and drift. This module breaks ground loops and stabilizes analog signals.

Cross-cabinet signal transmission between cabinets with different potential (LV cabinet, VFD cabinet, DCS cabinet). It isolates potential offset and protects PLC analog channels from common-mode overvoltage damage.

  1. Signal Type Conversion

Field transmitters output voltage signals (0–10V/1–5V), while the two downstream receiving devices only accept 4–20mA current input. This unit converts the voltage input into two isolated current outputs.

  1. Industry-Specific Applications

Chemical, Water Treatment & Municipal Wastewater: Level, pH, turbidity, flow and pressure. Many projects require simultaneous control and data logging; suitable for Zone 2 cabinet installation (Zone 2 only, NOT intrinsic safety barrier).

Power & New Energy (PV / Energy Storage / Power Distribution): Bus voltage, transducer signals, cooling water temperature, split to PLC and waveform recording device.

HVAC, Building Automation & Cleanrooms: Temperature, humidity and differential pressure transmitters, split for BA controller and independent monitoring system.

Marine & Railway (GL Marine Certificate): Cabin pressure and temperature monitoring. Ultra-slim footprint saves cabinet space for marine control cabinets.

Packaging, Rubber & Plastics, Machine Tools & Custom Automation: Tension, pressure and displacement sensors. One output for motion control PLC, the other for quality inspection recording system.

  1. Selection Limitations & Notes
  2. Both outputs are current only, voltage output is not supported. Do not select this model if one current + one voltage split is required.
  3. It is an isolated duplication amplifier, not an intrinsically safe barrier. It cannot directly connect to IS instruments in Zone 0 / Zone 1; it may only be fitted inside Zone 2 hazardous-area cabinets.
  4. Excellent for slim cabinets and high-density I/O layouts. TBUS bus bases support daisy-chain rail power supply to reduce wiring work.

Phoenix Contact Analog Signal Duplicator (1-in-2-out Signal Repeater) Order List

Two major series: Legacy MINI MCR-SL (6.2mm ultra-slim, including 2864794, phasing out) and New MINI MCR-2 / MINI Analog Pro (replacement series, freely configurable current/voltage output, NFC configuration supported)

Definition: Signal Duplicator (1-in-2-out isolated repeater). Pure 1-in-1-out isolators are excluded from this table.

  1. Legacy MINI MCR-SL Series | UI-2I (UI Input, Dual Current Output 4/0–20mA)
Order No.Full ModelDescriptionStatus
2864794MINI MCR-SL-UI-2ICustom configuration, non-returnableObsolete, recommend 2905025
2864176MINI MCR-SL-UI-2I-NCStandard pre-configured, regular stockObsolete
2864804MINI MCR-SL-UI-2I-SPCustom configuration, non-returnableObsolete, recommend 2905027
2864189MINI MCR-SL-UI-2I-SP-NCStandard pre-configuredObsolete

Common limitation for legacy models: dual outputs are current only, voltage output unavailable; 4-way isolation (Input / Out1 / Out2 / Power isolated).

  1. New MINI MCR-2 Universal Duplicator UNI-UI-2UI (UI Universal Input, Two Outputs Independently Configurable for Voltage or Current)
Order No.Full ModelConnection TypeDescription
2905026MINI MCR-2-UNI-UI-2UIScrewStandard pre-configured NC
2905025MINI MCR-2-UNI-UI-2UI-CScrewCustom configuration C (replaces legacy 2864794)
2905028MINI MCR-2-UNI-UI-2UI-PTPush-inStandard pre-configured NC
2905027MINI MCR-2-UNI-UI-2UI-PT-CPush-inCustom configuration C (replaces legacy 2864804)

Upgrade highlights for new series: each output independently configurable as current or voltage, DIP + NFC + software configuration, fault diagnostics, improved accuracy.

  1. Additional 1-in-2-out Duplicators in Family (Loop-Powered Version)
Order No.Full ModelDescription
2905628MINI MCR-2-RPSS-I-2ILoop-powered, 1 current input, 2 current outputs, screw connection
2905629MINI MCR-2-RPSS-I-2I-PTLoop-powered, 1 current input, 2 current outputs, Push-in
  1. Matching Accessories (Bus Power Base for Duplicators)
Order No.NamePurpose
2869728ME 6,2 TBUS-2 1,5/5-ST-3,81 GNTBUS rail bus connector for parallel power supply, compatible with slim MINI MCR-SL
2864134MINI MCR-SL-PTBPower terminal block

Quick Cross Reference for Replacement

2864794 (screw, custom) → 2905025

2864176 (screw, standard) → 2905026

2864804 (spring-cage, custom) → 2905027

2864189 (spring-cage, standard) → 2905028

MINI MCR-SL-UI-UI-NC (2864150): 1-in-1-out isolator, NOT a duplicator, excluded

MACX series are mostly high-withstand, SIL functional safety or explosion-proof isolators, not general signal duplicators.

Phoenix MINI MCR-2 / MINI Analog Pro Analog Signal Duplicator (1-in-2-out Isolated Repeater) Order List

Notes: MINI MCR-2 belongs to the MINI Analog Pro platform; supports NFC / software / DIP configuration, fault diagnosis, 4-way isolation. Split into universal UI input duplicator and loop-powered HART RPSS-I-2I. PT = Push-in quick connection; no PT suffix = screw connection; suffix -C = made-to-order custom configuration (non-returnable).

  1. Universal Multi-Range Type: MINI MCR-2-UNI-UI-2UI (Universal UI Input, Two Outputs Independently Selectable for Current / Voltage)
Order No.Full ModelDescriptionLegacy Replacement
2905026MINI MCR-2-UNI-UI-2UIStandard pre-configured NC, regular stock2864176
2905025MINI MCR-2-UNI-UI-2UI-CCustom configuration C, parameters specified on order, non-returnable2864794 (your original part)
2905028MINI MCR-2-UNI-UI-2UI-PTStandard pre-configured NC2864189
2905027MINI MCR-2-UNI-UI-2UI-PT-CCustom configuration C, non-returnable2864804

Features: Input accepts 0/4–20mA, 0–10V, 1–5V; OUT1 and OUT2 can be independently set to current or voltage, mixed output allowed. Supports HART pass-through, NFC mobile configuration, fault alarm, Zone 2 Ex certification.

  1. Loop-Powered Type: MINI MCR-2-RPSS-I-2I (4–20mA Loop Powered, HART Transparent, 1-in-2-out Current)
Order No.Full ModelConnection TypeDescription
2905628MINI MCR-2-RPSS-I-2IScrewLoop-powered, HART transparent, dual current output
2905629MINI MCR-2-RPSS-I-2I-PTPush-inLoop-powered, HART transparent, dual current output

Features: Powered directly from transmitter loop, independent 24V supply not required. Two passive 4–20mA outputs. Ideal for 2-wire HART transmitters, shared measurement points for DCS/SIS. Max. load per channel up to 500Ω.

  1. Matching Accessories (General for MINI Analog Pro Platform)
Order No.NamePurpose
2902066MINI MCR-2-PTBScrew-type power terminal for rail bus daisy-chain power supply
2902067MINI MCR-2-PTB-PTPush-in power terminal
2904504MINI MCR-2-FM-RCScrew fault collective alarm module
2904508MINI MCR-2-FM-RC-PTPush-in fault collective alarm module
2905634MINI MCR-2-V8-MOD-RTUModbus-RTU communication adapter, supports up to 8 modules in network
2905635MINI MCR-2-V8-MOD-TCPModbus-TCP communication adapter, supports up to 8 modules in network
  1. Selection Guidance & Pitfall Avoidance
  2. UNI-UI-2UI: Requires separate 24VDC supply, universal voltage/current input, two outputs can mix voltage + current. Direct upgrade replacement for legacy MINI MCR-SL-UI-2I.
  3. RPSS-I-2I: Loop-powered, current input only, dual current output only. Preferred for HART projects; cannot be used for voltage signal splitting.
  4. 1-in-1-out isolators of the same series (e.g. MINI MCR-2-UI-UI) are not duplicators and excluded from this list.
  5. HS Code: 85437090, Country of origin: Germany (DE)

Prev:

Leave a Reply

Leave a message