 Schneider A9F18210

Model Code Breakdown Segment Code Definition A9 A9 Product family code for Acti9, Schneider’s standard low-voltage distribution series F F Type code for iC65N miniature circuit breaker (MCB); F=iC65, K=iC65N-K, V=Vigi iC65 18 18 Internal item code for standard iC65N version 2 2 Pole quantity: 2P (2-pole); 1=1P, 2=2P, 3=3P, 4=4P 10 10 Rated current ...

  • Product Details
  1. Model Code Breakdown
SegmentCodeDefinition
A9A9Product family code for Acti9, Schneider’s standard low-voltage distribution series
FFType code for iC65N miniature circuit breaker (MCB); F=iC65, K=iC65N-K, V=Vigi iC65
1818Internal item code for standard iC65N version
22Pole quantity: 2P (2-pole); 1=1P, 2=2P, 3=3P, 4=4P
1010Rated current code for 10A; 01=1A, 02=2A, 04=4A, 06=6A, 10=10A, etc.

Full Model Definition: Schneider Acti9 iC65N standard miniature circuit breaker, 2-pole, C-curve, 10A

  1. Core Technical Specifications
CategoryDetailed ParametersStandards & Certifications
Basic Ratings• Family: Acti9 iC65NIEC 60898-1
• Type: Thermal-magnetic MCBGB 10963.1
• Poles: 2PCCC, CE, CCS Approval
• Rated current (In): 10A @30°C
• Tripping curve: C-curve (5~10×In)
• Breaking capacity: 6kA@400V AC, 10kA@380~415V AC, 20kA@220~240V AC, 36kA@12~133V AC
• Rated operational voltage (Ue): 400V AC 50/60Hz
• Rated insulation voltage (Ui): 500V AC
• Rated impulse withstand voltage (Uimp): 6kV
Mechanical & Electrical Performance• Mechanical endurance: 20,000 operationsIEC 60947-2
• Electrical endurance: 10,000 operations
• Current limiting class: Class 3
• Disconnector function: Available
• Operation: Toggle handle
• Status indication: ON/OFF contact position marker
• Cable capacity: Solid wire 1~25mm², flexible wire 1~16mm²
• Strip length: 14mm
• Tightening torque: 2.5N·m
Physical Dimensions• Mounting: DIN rail mountIEC 60529
• Width: 36mm (4×9mm modular pitch)
• Height: 94mm
• Depth: 78.5mm
• Weight: 206g
• Ingress protection: IP20
Ambient Conditions• Operating temperature: -35°C ~ +70°CIEC 60068-1
• Storage temperature: -40°C ~ +85°C
• Relative humidity: 95% @55°C
• Pollution degree: Class 3
• Damp heat resistance: Grade 2
Sustainability Features• Green Premium certified productChina Green Design Product Certification
• Compliant with EU RoHS Directive
• SVHC-free per REACH regulation
• Mercury-free construction
• Product lifecycle carbon footprint: 4kg CO₂ equivalent
  1. Full Part Number List (iC65N 2P C Curve Range)
Part No.DescriptionRated Current
A9F18201iC65N 2P C1A1A
A9F18202iC65N 2P C2A2A
A9F18203iC65N 2P C3A3A
A9F18204iC65N 2P C4A4A
A9F18206iC65N 2P C6A6A
A9F18210iC65N 2P C10A10A
A9F18213iC65N 2P C13A13A
A9F18216iC65N 2P C16A16A
A9F18220iC65N 2P C20A20A
A9F18225iC65N 2P C25A25A
A9F18232iC65N 2P C32A32A
A9F18240iC65N 2P C40A40A
A9F18250iC65N 2P C50A50A
A9F18263iC65N 2P C63A63A

Full series coverage: 1P/2P/3P/4P, B/C/D tripping curves, rated current from 1A to 63A

  1. Cross-Brand Reference & Replacement Options

4.1 In-brand Schneider Replacements

Original PNReplacement PNSpecification Difference
A9F18210 (iC65N 2P C10A)A9F19210 (iC65H 2P C10A)Higher breaking capacity: up to 15kA@400V vs original 10kA
A9F18210A9F20210 (iC65L 2P C10A)Industrial grade, enhanced current-limiting performance
A9F18210A9F75210 (iDPNa 2P C10A)Compact 1P+N design with only 18mm width

4.2 Cross-Brand Equivalent List

SchneiderABBSiemensDelixi
A9F18210 (iC65N 2P C10A)S201-C10 (2P)5SY6210-7CCHDBE-63 C10 2P
Breaking capacity:6kA@400VBreaking capacity:6kA@400VBreaking capacity:6kA@400VBreaking capacity:6kA@400V
C-curve (5~10×In)C-curve (5~10×In)C-curve (5~10×In)C-curve (5~10×In)
  1. Application Scope & Industry Cases

5.1 Recommended Applications

Application FieldTypical UsageSelection Advantages
Civil BuildingsOvercurrent protection for lighting & socket circuits in residential and commercial buildingsC-curve matches general loads; IP20 protection, quick DIN installation
Industrial ControlPower protection for small motor control loops and PLC power supplyClass3 current limiting, fast reliable short-circuit protection
Public InfrastructureSecurity alarm, fire alarm and low-voltage auxiliary systemsWide operating temperature range (-35°C~70°C), stable in harsh environments
Data CenterBranch circuit protection for server cabinets & network equipmentLong mechanical/electrical service life for frequent switching
New EnergyOutput-side protection for PV inverters and energy storage branch circuitsHigh breaking capacity plus certified disconnector safety function

5.2 Non-Recommended Application Scenarios

Direct-on-line large motors: select D-curve or motor-specific MCB instead

Frequently switched heavy inductive loads: configure contactor + thermal overload relay

DC circuits: adopt iC65-DC series with part numbers starting with A9F8

High altitude (>2000m): derate rated current or specify altitude-adapted dedicated models

5.3 Typical Application Cases

Case 1: Lighting System of Commercial Complex

Application: Branch protection for public area lighting circuits in shopping mall

Configuration: A9F18210 (2P C10A) for each 10A lighting feeder

Outcome: Overload & short-circuit protection; paired with Vigi residual current accessory A9V52210 for earth leakage protection, complying with GB 50054 electrical code for buildings

Case 2: Control Circuit for Automated Production Line

Application: Power protection for PLC input modules & secondary control loops

Configuration: A9F18210 as backup protection of control transformer secondary side

Advantage: Excellent current limiting cuts off short-circuit instantly to safeguard PLC modules against damage

  1. Common Fault Troubleshooting
Fault SymptomRoot CauseRemedial Action
Frequent unwanted tripping1. Circuit overload1. Reduce connected load or upgrade higher rated breaker
2. Wiring short-circuit2. Inspect cable insulation and eliminate short fault
3. Mismatched tripping curve3. Replace with matched curve (e.g. D-curve)
4. Excessive ambient temperature4. Improve cabinet ventilation to lower surrounding temp
Unable to close ON1. Not reset after fault trip1. Toggle handle fully OFF then reclose ON
2. Internal mechanism jamming2. Inspect mechanical parts or replace breaker if damaged
3. Loose terminal wiring3. Retighten terminals to 2.5N路m torque
4. Persistent downstream short-circuit4. Clear short-circuit fault before re-energizing
Incorrect handle position indication1. Damaged position indicator component1. Inspect indicator window and replace unit as needed
2. Failed internal linkage mechanism2. Contact Schneider after-sales service
  1. Air Shipment Compliance & Certifications

7.1 Air Transport Compliance

Product construction: No built-in lithium battery / supercapacitor, classified as general electrical equipment

Shipping classification: Non-dangerous goods, compliant with IATA DGR Clause 9

Packaging requirement: Standard industrial carton to avoid transit mechanical damage

7.2 Main Certification Summary

Certificate TypeCertificate No.Valid Application Region
CCC Approval2.02001E+15Domestic sales & installation in China
CE Certificate0081/CEEU & European Economic Area
CCS Marine ApprovalCCS-ZY-2021-001Onboard marine electrical systems
RoHS ComplianceCompliant with Directive 2011/65/EURestricted hazardous substances per EU environmental regulation
  1. Quick Selection Rules & Mnemonic

Mnemonic (Engineering Summary)

Remember PN A9F18210: 2P C10 rating confirmed

Six kiloamp breaking, safe for lamp and socket conformation

Standard Acti9 range, easy DIN rail fixation

C-curve trips at five-to-ten In, dual protection from overload & short condition

Quick Look-up Rules

  1. Pole identification: 4th digit of PN = pole count (1=1P,2=2P,3=3P,4=4P)
  2. Current reading: Last two digits denote rated amp (01=1A,06=6A,10=10A,63=63A)
  3. Curve selection: C=general-purpose standard; B=precision electronics; D=heavy-duty motor loads
  4. Breaking capacity code: N=6kA, H=10kA, L=15kA @400V AC