Schneider TeSys D / TeSys Deca series, 3-pole with 3 main NO contacts. Designed for three-phase motors, HVAC, water pumps, fans and other load control. It comes with built-in 1NO + 1NC auxiliary contacts (NC is mirror contact for safety circuits).
✅ Core Specifications
Poles: 3P (3 NO main contacts)
Rated operational current AC-3 @ 440V: 40 A
Matched motor power @ 380/400V: 18.5 kW
Max operational voltage (Ue) for power circuit: 690 V
Conventional thermal current (Ith): 60 A
Built-in auxiliary contacts: 1NO (14) + 1NC (22)
Mounting: 35 mm DIN rail or screw fixing
Overall dimensions: W55 × H122 × D120 mm
Terminals: EverLink anti-loosening screw terminals (new version with suffix A)
Certifications: CCC, IEC 60947-4-1, UL, CSA, marine certification
✅ Model Suffix Definition (Full Model Example: LC1D40AM7C)
A: New Deca version (old version without A: LC1D40M7C, direct interchangeable)
M: 220 V AC coil (50/60 Hz)
F: 110 V AC; Q: 380 V AC; B: 24 V DC; BD: standard 24 V DC coil
7: 50/60 Hz universal; C: China domestic version
Common stock models:
LC1D40AM7C (220VAC), LC1D40AF7C (110VAC), LC1D40AQ7C (380VAC), LC1D40ABD (24VDC)
✅ Matching Accessories
Thermal overload relay: LRD3353C (adjustment range 23–32 A) for 18.5 kW motors
Auxiliary contact block: LA1DN (expand auxiliary contacts)
Mechanical interlock: LA9D40 (for star-delta & forward/reverse interlock)
Coil surge suppressor: LA4DA
Time delay attachment, busbar connectors, etc.
✅ Selection & Replacement
- Old-to-new replacement: LC1D40 → new LC1D40A, identical dimensions, mounting holes and wiring, plug-and-play.
- Adjacent frame size: smaller LC1D32; larger LC1D50.
- Economy alternative: Easypact D3N LC1N40.
- Domestic equivalent: CJX2-4011.
✅ Typical Applications
Fans, water pumps, air compressors, central air conditioning, conveyors, star-delta starters, forward/reverse control cabinets (AC-3 motor duty); also for AC-1 resistive loads (heating elements).
✅ Installation Instructions
Torque: Main circuit terminals = 5 N·m; control circuit = 1.7 N·m
Max ambient temperature: 60 °C; max operating frequency: 3600 cycles/hour
DC coil version requires polarity: A1 = positive, A2 = negative
Matched thermal relay for LC1D40 (18.5kW @ 380V): LRD3353C, setting range 23~32 A, Class 10A
- LRD3353C Overload Current Setting Table
1) Setting Rule (Mandatory)
Set the thermal relay knob to motor nameplate full-load current (FLA), NOT the 40A contactor rating.
380V 18.5kW 3-phase motor: rated current ≈ 32 A → set knob directly to 32 A (full scale).
For fan-type motors, heavy starting & frequent jogging: set to 100%~105% of FLA; never exceed 115%.
Ambient temperature >40°C or enclosed cabinet: reduce setting by 5%~10%.
2) LC1D Series Contactor + LRD Thermal Relay Matching List
| Contactor Model | AC-3 Current | Motor Power @ 380V | Matching Thermal Relay |
| LC1D40A | 40 A | 18.5 kW | LRD3353C |
| LC1D50A | 50 A | 22 kW | LRD3355C |
| LC1D65A | 65 A | 30 kW | LRD3357C |
| LC1D80A | 80 A | 37 kW | LRD3359C |
| LC1D95A | 95 A | 45 kW | LRD3361C |
| LC1D115 | 115 A | 55 kW | LRD3363C |
| LC1D150 | 150 A | 75 kW | LRD3365C |
High-current older models (being upgraded to AKUE wide-voltage coil)
LC1D170, LC1D205, LC1D245, LC1D300, LC1D410
- 4-Pole Models (LC1DT, AC-1 resistive loads: heating, 3-phase 4-wire)
4NO Main Contacts (LC1DTxxA)
LC1DT20A, LC1DT25A, LC1DT32A, LC1DT40A, LC1DT60A, LC1DT80A
2NO + 2NC Main Contacts (LC1Dxx8)
LC1D128, LC1D188, LC1D258, LC1D40008, LC1D65008
III. Coil Voltage Suffix Code
AC Coils (50/60Hz universal, suffix 7)
B7: 24 V AC
E7: 48 V AC
F7: 110 V AC
M7: 220 V AC (most common)
P7: 230 V AC
Q7: 380 V AC
DC Coils (suffix D)
BD: 24 V DC (standard DC coil)
ED: 48 V DC
GD: 125 V DC
End-of-model Letters
C = Domestic China TeSys Deca version (local stock)
A = New EverLink anti-loosening terminals; no A = old terminal version
✅ Full stock model examples:
LC1D40AM7C (220VAC), LC1D40AF7C (110VAC), LC1D40AQ7C (380VAC), LC1D40ABD (24VDC)
- Reversing Contactors (LC2D, Forward/Reverse Control)
LC2D09A, LC2D12A, LC2D18A, LC2D25A, LC2D32A, LC2D40A, LC2D50A, LC2D65A, LC2D80A, LC2D95A
Built-in mechanical + electrical interlock; no extra LA9D40 required.
- Full LRD Thermal Relay Matching List (for LC1D)
- Low current range (0.1~32 A): LRD01C ~ LRD22C
- 40A and above (23~104 A): LRD33 series
LRD3353C: 23–32 A → LC1D40A (18.5 kW)
LRD3355C: 30–40 A → LC1D50A
LRD3357C: 37–50 A → LC1D65A
- Replacement Rules
- Old LC1D40M7C → new LC1D40AM7C: fully interchangeable (same footprint, mounting & wiring).
- Older high-current LC1D115 / LC1D150 → upgrade to LC1D115AKUE / LC1D150AKUE (100–250V AC/DC wide-voltage coil).
Contactor,circuit breaker,sensor,Encoder,PLC,Converter


















NH42-63-318x560.png)