Schneider SSM1A120BD Single-Phase Solid State Relay - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

Wechat: +86-13184948252  WhatsaApp: 0086-13811255435  E-mail:  kent@bestcontactor.com

About    Contact    |    

Schneider SSM1A120BD Single-Phase Solid State Relay - Contactor,circuit breaker,sensor,Encoder,PLC,Converter

PLC/electrical/

Schneider SSM1A120BD Single-Phase Solid State Relay

Series: Zelio / Harmony SSM1 Single-phase Solid State Relay|Status: Discontinued Model Code Explanation SSM1: DIN rail-mounted solid state relay of SSM1 series A: AC output 1: Single phase 20: Rated load current 20A BD: DC control (4-32VDC), Zero Voltage Switching (ZVS) -📌 Core Specifications Item Parameter Control Input DC 4~32 V, Turn-on ≥4V, Turn-off ≤1V; ...

  • Product Details

Series: Zelio / Harmony SSM1 Single-phase Solid State Relay|Status: Discontinued

Model Code Explanation

SSM1: DIN rail-mounted solid state relay of SSM1 series

A: AC output

1: Single phase

20: Rated load current 20A

BD: DC control (4-32VDC), Zero Voltage Switching (ZVS)

-📌 Core Specifications

ItemParameter
Control InputDC 4~32 V, Turn-on ≥4V, Turn-off ≤1V; Input current 8~12mA
Load OutputAC 24~280 V, single phase, 1NO, SCR output, zero voltage switching
Rated Load Current20A (Derating required at elevated ambient temperature)
MountingSymmetrical DIN rail mounting
Overall Dimensions22.5 × 98.8 × 97.7 mm|Weight: 0.28 kg
TerminalsScrew terminals, wire gauge 0.2~5.3 mm² (AWG24~AWG10)
TorqueInput: 0.6–0.7 N·m; Output: 1.36–1.7 N·m
Status IndicatorGreen LED, lights up when input is energized
On-state Voltage Drop≤1.6V
Off-state Leakage Current≤10mA
Surge Current≤250A / 16.6ms
Operating Temperature-40℃ ~ +80℃; Storage: -40~125℃
Dielectric Withstand Voltage (Input to Output)4kV AC
Protection ClassIP20
CertificationsCE, UL, CSA, EAC, RoHS compliant

📎 Features & Applications

Zero voltage switching: Turns on at AC zero crossing to suppress EMI, ideal for resistive loads (heating elements, incandescent lamps)

No mechanical contacts, no arcing, long service life, suitable for high-frequency switching and vibration-prone environments

Not recommended for heavy inductive loads or transformers (snubber circuit required)

|Typical Applications|Temperature-controlled heating, lighting control, ovens, HVAC heating circuits|

Replacement Notes

There is no direct pin-to-pin replacement model from the original manufacturer. Cross-reference within the same series:

SSM1A120BDR: Same electrical rating, random switching (non-zero-crossing). Pay attention to the switching mode difference.

Alternatives: New SSR models in SSM1 series or other brands of 20A zero-crossing SSR (e.g. Omron, Crydom)

Key selection checklist: Control voltage, output voltage, switching mode, thermal derating curve

  1. Input side: + / connect to PLC or digital DC signal (4-32VDC)
  2. Output side: Series-connected in AC load circuit, phase-insensitive for AC
  3. Heat dissipation must be guaranteed; leave gaps when densely mounted, derate current at high temperature, fit a suitable fast fuse at upstream

Schneider SSM1A120BD Full Original Datasheet (Zelio / Harmony SSM1 Single-phase Solid State Relay)

1. Model Coding Explanation

SSM1 A 1 20 BD

SSM1: Modular DIN rail solid state relay of SSM1 series

A: AC output type

1: Single phase

20: Rated current 20A

BD: DC control 4-32V DC, Zero Voltage Switching

2. Main Specification Table

Parameter ItemValue
Product TypeSingle-phase solid state relay, SCR output, 1NO normally open
Control Input Voltage Uc4~32 V DC; Turn-on ≥4VDC, Turn-off ≤1VDC
Input Current8~12 mA
Load Output Voltage24~280 V AC
Rated Load Current In20 A (Derating required at elevated ambient temperature)
Minimum Load Current0.15 A
Switching ModeZero voltage switching (ZVS)
On-state Voltage Drop≤1.6 V
Off-state Leakage Current≤10 mA
Off-state dV/dt500 V/μs
Transient Withstand Voltage600 V
Surge Current≤250 A @16.6 ms
I²t (for fuse selection)260 A²·s @8.3 ms
Response TimeTurn-on: 0.5 power frequency cycle; Turn-off: 0.5 power frequency cycle
Status IndicatorGreen LED, lights up when input is powered

3. Terminal & Mechanical Specifications

ItemParameter
MountingSymmetrical DIN rail snap mounting
Dimensions (W×H×D)22.5 × 98.8 × 97.7 mm
Net Weight0.28 kg
Terminal TypeScrew terminals
Suitable Wire Gauge0.2~5.3 mm² (AWG24~AWG10) for both input and output
Tightening TorqueInput terminal: 0.6~0.7 N·mOutput terminal: 1.36~1.7 N·m
Parasitic Capacitance between Input & Output≤8 pF

4. Insulation, Protection & Environmental Ratings

ItemParameter
Input ↔ Output Dielectric Withstand Voltage4 kV AC
Input/Output ↔ Housing Withstand Voltage4 kV AC
Insulation Resistance≥1000 MΩ @500 V DC
Protection ClassIP20 (for cabinet internal use)
Operating Ambient Temperature-40 ℃ ~ +80 ℃
Storage Temperature-40 ℃ ~ +125 ℃
Pollution Degree2
Overvoltage CategoryIII
CertificationsCE, UL, CSA, EAC, RoHS, Green Premium
Applicable StandardsUL508, CSA C22.2 No.14, IEC60950-1

5. Derating Curve Guidance (Critical)

25℃ ambient: Full rating 20A

Linear current derating when ambient temperature>40℃; allowable current drops significantly at 80℃

Additional derating is required for densely side-by-side installation due to mutual thermal interference

✅ Recommended: For resistive heating loads, select at 70% of rated current; avoid continuous full-load operation

6. Terminal Definition

  1. Control Input: DC+, DCconnect to PLC / temperature controller transistor output (4-32VDC, polarity-sensitive)
  2. Load Output: Series-connected in 220VAC circuit, phase independent; one end to live line L, one end to load
  3. Fast fuse is recommended in series with load side; RC snubber or varistor is mandatory for inductive loads (transformers, solenoid valves)

7. ey Variant Comparison by Suffix

SSM1A120BD: Zero-cross switching ZVS, for heating and incandescent lamps, low EMI

SSM1A120BDR: Random switching, for instant turn-on or phase control applications. Not directly interchangeable

8. Application Limitations

✅ Suitable for: Resistive heating elements, infrared lamps, constant-temperature ovens, HVAC heating, low-interference lighting control

❌ Not recommended for: Heavy inductive loads, direct motor start-stop; snubber circuit is required

Application Cases of SSM1A120BD (Zero-cross SSR, 4-32VDC control, 20A, 24-280VAC for resistive loads preferred)

Core advantages: Zero-cross turn-on, low EMI, contactless, vibration resistant, compact DIN rail mounting, direct driving by PLC DC points. For resistive loads; snubber circuit required for inductive loads

Case 1: Barrel Heating Control for Injection Molding Machines (Most Common)

Load: Single-section 220V heating band (resistive, ≤4kW, 20A class)

Control architecture: PLC (4-24VDC output) → SSM1A120BD → heating band; PID output from temperature controller drives SSR

Selection logic: Zero-cross switching reduces grid harmonic distortion and inrush current of heating bands; contactless design avoids burning contacts under frequent switching

Auxiliary components: Fast fuse for each circuit; reserve heat dissipation gap for multi-section heating installed side by side and derate current at high temperature; thermocouple closed-loop temperature control

Risk note: Fuse provides protection against leakage and short circuit of heating bands; do not drive barrel cooling fans (inductive) directly

Case 2: HVAC / Air Duct Electric Heater & Fresh Air Preheating Module

Load: Single-phase duct heating tubes, PTC heating (resistive)

Control: DDC / PLC digital output for constant temperature start-stop and anti-freeze heating in winter

Highlights: Silent and spark-free, suitable for dense installation in BMS control cabinets; wide temperature range -40~80℃, available for cabinet installation in machine rooms or outdoor environments

Caution: Air duct heater must interlock with air differential pressure switch to cut off SSR and prevent dry heating when airflow is lost

Case 3: Textile Machinery — Stenter, Oven & Infrared Lamp Heating

Load: Infrared heating lamps, heating tubes in setting zone

Working conditions: Long-period cyclic switching, heavy equipment vibration, lint and dust environment

Advantages: No mechanical contacts, vibration resistance, far longer service life than AC contactors; zero-cross triggering reduces lamp inrush and extends lamp lifespan

Cabinet requirement: Dustproof control cabinet; avoid dust accumulation blocking SSR heat sink fins

Case 4: Heat Sealing, Hot Knife & Hot Stamping Heating for Packaging Machinery

Load: Heat sealing strip, hot stamping heating plate (resistive)

Working conditions: High-frequency short-cycle switching; conventional relays tend to stick under fast cycles

Solution: PLC output directly drives SSM1A120BD with temperature controller for stable sealing temperature

Comparison: Electromagnetic relays wear out after thousands of operations; SSR supports millions of switching cycles

Case 5: Food Drying, Constant Temperature Ovens & Laboratory Incubators

Load: Stainless steel heating tubes, 220V single-phase resistive load

Control: Temperature controller + SSR for ON/OFF or PID cycle power regulation (not phase angle regulation; zero-cross SSR is suitable for burst firing)

Scenarios: Food, herbal and material drying, low interference requirement to protect temperature sensors and weighing instruments

Case 6: Lighting Load (Halogen Lamps, Incandescent Lamps; NOT for LED Drivers)

Load: Halogen tubes, traditional incandescent lamps (resistive)

Description: Zero-cross turn-on suppresses inrush surge and extends lamp life; not suitable for LED power supplies or electronic ballasts-(internal capacitance causes large surge and may damage SSR)

Restriction: Special dimming modules are recommended for LED lamps instead of direct SSR switching

⚠️ Scenarios Not Recommended for Direct Use (Common On-site Failures)

  1. Single-phase motors, water pumps, solenoid valves (inductive loads): RC snubber + varistor must be fitted, otherwise false triggering or breakdown may occur
  2. Direct primary switching of transformers: High magnetizing inrush current easily damages this 20A SSR
  3. High-frequency voltage regulation and phase chopping: This model is ZVS zero-cross type, not random type (SSM1A120BDR for random triggering); cannot perform phase angle dimming

📌 General On-site Wiring Framework (Applicable to All Cases)

Input: DC+, DCconnect to PLC / temperature controller transistor output (4-32VDC, polarity-sensitive)

Output: Series-connected between 220VAC live wire and load, AC phase independent

Protection: Fast fuse (gG/aM) in series on output side; derate current when cabinet temperature>40℃

Diagnosis: Green LED lights up when input is energized for easy commissioning and troubleshooting

Complete List of Schneider Harmony SSM1 Single-phase Solid State Relays (DIN Rail Type)

Coding Rule:

SSM1 + Output type(A=AC / D=DC) + Output voltage code + 1(Single phase) + Current + Control code + R (R=Random switching; No suffix = Zero voltage switching)

Control Code: BD=4-32VDC; B7=18-36VAC; F7=90-140VAC; P7=200-265VAC; M7=90-280VAC

Remark: The whole SSM1 series is discontinued by original manufacturer

1. AC Output · 24~280VAC (Code 1, Most Common; SSM1A120BD belongs to this group)

ModelRated CurrentControl InputSwitching Mode
SSM1A16BD6A4–32VDCZero-cross
SSM1A16BDR6A4–32VDCRandom
SSM1A16B76A18–36VACZero-cross
SSM1A16B7R6A18–36VACRandom
SSM1A16F76A90–140VACZero-cross
SSM1A16F7R6A90–140VACRandom
SSM1A16P76A200–265VACZero-cross
SSM1A112BD12A4–32VDCZero-cross
SSM1A112BDR12A4–32VDCRandom
SSM1A112B712A18–36VACZero-cross
SSM1A112B7R12A18–36VACRandom
SSM1A112F712A90–140VACZero-cross
SSM1A112F7R12A90–140VACRandom
SSM1A112P712A200–265VACZero-cross
SSM1A120BD20A4–32VDCZero-cross
SSM1A120BDR20A4–32VDCRandom
SSM1A120M720A90–280VACZero-cross
SSM1A130BD30A4–32VDCZero-cross
SSM1A130BDR30A4–32VDCRandom
SSM1A130M730A90–280VACZero-cross
SSM1A145BD45A3–32VDCZero-cross

2. AC Output · 48~600/660VAC (Code 3/4, High Voltage Version)

ModelRated CurrentControl InputSwitching Mode
SSM1A36BD6A4–32VDCZero-cross
SSM1A36BDR6A4–32VDCRandom
SSM1A36B76A18–36VACZero-cross
SSM1A312BD12A4–32VDCZero-cross
SSM1A312BDR12A4–32VDCRandom
SSM1A312B712A18–36VACZero-cross
SSM1A312F712A90–140VACZero-cross
SSM1A430BD30A4–32VDCZero-cross
SSM1A430M730A90–280VACZero-cross
SSM1A445BD45A3–32VDCZero-cross
SSM1A445F745A90–140VACZero-cross
SSM1A455BD55A3–32VDCZero-cross
SSM1A455F755A90–140VACZero-cross

3. DC Output SSM1D (MOSFET DC Switch for DC Loads)

ModelRated CurrentControl InputOutput Voltage
SSM1D212BD12A4–32VDC1–60VDC
SSM1D36BD6A4–32VDC1–100VDC
SSM1D312BD12A4–32VDC1–100VDC

4. Additional Selection Notes (Avoid Pitfalls)

  1. Suffix R = Random switching: Suitable for phase angle regulation and inductive loads; No suffix = ZVS zero-cross, preferred for heating and resistive loads (SSM1A120BD)
  2. Width: 6A/12A →12/18mm; 20A/30A →22.5mm; 45A/55A →45mm
  3. All variants are single-channel single-phase 1NO normally open. SSM2 series is dual-channel single-phase and excluded from this single-phase SSR list
  4. Replacement strategy for discontinued parts: Prioritize verification of four parameters: control voltage, output voltage, switching mode, current rating. Alternatives include domestic SSR, Crydom and Omron equivalents

Prev:

Next:

Leave a Reply

Leave a message