Entry-level economical three-phase VFD, version without built-in EMC filter
Model Code Explanation
ATV310: Altivar Easy 310 series (simple general-purpose vector type)
H: Frame size code
U75: Heavy-duty rating 7.5 kW
N4: Three-phase 380~460 V
E: Without built-in EMC filter (Contrast: ATV310HU75N4A with built-in EMC filter)
⚡ Rated Power & Current
Heavy Duty (HD): 7.5 kW / 10 HP, continuous output 17 A; 60 s overload 170~200% (25.5 A)
Normal Duty (ND): 11 kW / 15 HP, continuous output 22.8 A; 60 s overload 110% (25.1 A)
Input: Three-phase 380–460 V, 50/60 Hz
Net weight: 3.7 kg; fan cooling standard, noise 50 dB(A)
🧠 Control Modes
V/F control (linear, quadratic energy-saving curve)
Sensorless vector control (SVC, open-loop vector)
Output frequency: 0.5 ~ 400 Hz
Switching frequency: 2 ~ 12 kHz adjustable, factory default 4 kHz
Speed regulation range: 1:20 for asynchronous motors
Braking: Approx. 70% braking torque without braking resistor; up to 150% braking torque with external braking resistor
Slip compensation adjustable
📶 Communication & I/O
Standard Modbus RTU, 2-wire RS485, front RJ45 port
Baud rate: 4800/9600/19200/38400 bps, address 1–247
Terminals: 4 digital inputs LI, 1 analog input AI, relay output; supports potentiometer, terminal start/stop, multi-speed, PID (fan & pump)
🌡️ Ambient & Certifications
Heavy duty: -10 ~ 55 °C without derating; short-time max 60 °C
Coating: 3C3/3S2, suitable for standard control cabinets and light dust environments
Certifications: CE, EAC, RoHS, WEEE
Protection: IP20 (for cabinet mounting only)
📌 Typical Applications
Conveyors, fans, pumps, general machine tools, material handling, speed regulation for ordinary asynchronous motors, suitable for simple speed control and constant pressure water supply.
Schneider ATV310 VFD Fault Code List (Compatible with ATV310HU75N4E)
Note: Codes starting with F = fault, locked trip; codes starting with -= status prompt, NOT faults. Fault reset: power cycle / keypad reset / communication reset
| Fault Code | Fault Description | Common Causes | Remedial Actions |
| F001 | Pre-charge fault | Failed DC bus pre-charge on power-up, faulty charging circuit or bus capacitor | Check input power, rectifier bridge, charging resistor; internal hardware fault requires repair |
| F002 | Power board identification error | Mismatched control board & power board, incompatible firmware | Verify model, reload firmware, replace matching boards |
| F003 | Power board incompatibility | Wrong power board model, mixed spare parts | Replace with original matching power board |
| F004 | Internal serial communication fault | Communication loss between control board and power board, loose ribbon cable | Re-seat ribbon cable; replace board if damaged |
| F005 | Region code error | Mismatched firmware regional version | Flash correct regional firmware |
| F006 | Current sensing circuit fault | Sampling circuit failure, damaged Hall sensor | Internal hardware fault, send for repair |
| F007 | Internal temperature sensor fault | Broken or faulty IGBT temperature sensor | If alarm occurs immediately on cold power-up, sensor is almost certainly damaged |
| F008 | CPU fault | Main controller anomaly, program runaway | Power cycle; if ineffective, replace control board |
| F009 | Over-braking (braking overspeed) | Too short deceleration time, high load inertia, faulty braking circuit | Extend deceleration time; install braking resistor / braking unit; check bus voltage |
| F010 | Overcurrent | Motor jam, motor short circuit, incorrect auto-tune, load surge | Check mechanical jamming; test motor insulation with megger; reduce switching frequency; re-run motor auto-tune |
| F011 | VFD overheat | Blocked air duct, faulty fan, high ambient temperature, continuous heavy load | Clean cooling air path; inspect fan; reduce ambient temperature; derate operation |
| F012 | Process overload | PID / process protection threshold triggered, sustained overload | Verify process overload parameters, check load condition |
| F013 | Motor overload | Long-term motor overcurrent, thermal protection threshold set too low | Check motor for stall; verify motor nameplate data; extend thermal protection time |
| F014 | Output single phase loss | Broken motor cable, burnt output contactor contact, loose terminal | Check U/V/W output wiring, terminals and output contactor |
| F015 | All output phases lost | Motor disconnected, all output contactors open, no-load detection alarm for small motors | Check motor wiring; disable phase loss detection for no-load test (parameter 605=00) |
| F016 | DC bus overvoltage | High grid voltage, regenerative energy during deceleration, failed braking circuit | Check input voltage; extend deceleration time; fit braking resistor |
| F017 | Input phase loss | Missing one incoming phase, poor contact of circuit breaker, blown fuse | Check upstream power supply, circuit breaker and incoming terminals |
| F018 | Motor short circuit | Inter-phase short circuit on motor winding or power cable | Disconnect motor and test VFD separately; megger motor insulation |
| F019 | Earth fault | Output cable earth fault, motor insulation breakdown, large leakage with multiple parallel motors | Megger motor and cable insulation; install output reactor |
| F020 | IGBT short circuit | Power module breakdown | Do NOT repeatedly power on; send for repair and replace power module directly |
| F021 | Output short circuit | Direct short circuit on VFD output side | Power off and inspect power cable to eliminate short point |
| F027 | IGBT over-temperature | Excessive IGBT junction temperature, poor heat dissipation | Prioritize cooling fan and air duct inspection, reduce load |
| F030 | DC bus undervoltage | Grid voltage dip, momentary power loss, insufficient incoming capacity | Check incoming voltage; inspect circuit breaker and terminal connections; confirm grid capacity |
Status Prompt Codes (Not Faults, Status Indication Only)
| Code | Meaning |
| 1 | Fast stop activated |
| 6 | Freewheel stop (coast stop) activated |
| 0 | Freewheel stop complete, standby |
Supplementary Practical Information
- Fault history: Parameters 910~921 to view historical faults and current/voltage readings at fault occurrence
- Phase loss detection parameter: 605 output phase loss detection (00=disabled, 01=enabled). Disable temporarily for no-load commissioning, keep enabled for formal operation
- Motor auto-tune: Parameter 318. Auto-tune is recommended after motor replacement to reduce F010 and F013 alarms
- Reset methods: Keypad reset, digital terminal assigned fault reset, Modbus communication reset, power cycle reset
Complete Model List for Schneider Altivar Easy ATV310 VFD
Note: Altivar Easy main product is ATV310. Voltage: three-phase 380–460 V. Suffix E = without built-in EMC filter, A = with built-in EMC filter. HD = heavy-duty power rating, ND = normal-duty power rating
Model Coding Explanation
ATV310: Altivar Easy 310 economical general-purpose vector VFD
H: Frame code
Power codes: 037=0.37 kW, 075=0.75 kW, U15=1.5 kW, U22=2.2 kW, U30=3 kW, U40=4 kW, U55=5.5 kW, U75=7.5 kW, D11=11 kW, D15=15 kW, D18=18.5 kW, D22=22 kW
N4: Three-phase 380~460 V
E: Without built-in EMC filter|A: With built-in EMC filter
E-version List (No Built-in EMC Filter, your ATV310HU75N4E is in this list)
| Model | HD Heavy Duty | ND Normal Duty |
| ATV310H037N4E | 0.37 kW / 0.5 HP | 0.55 kW / 0.75 HP |
| ATV310H075N4E | 0.75 kW / 1 HP | 1.1 kW / 1.5 HP |
| ATV310HU15N4E | 1.5 kW / 2 HP | 2.2 kW / 3 HP |
| ATV310HU22N4E | 2.2 kW / 3 HP | 3 kW / 4 HP |
| ATV310HU30N4E | 3 kW / 4 HP | 4 kW / 5 HP |
| ATV310HU40N4E | 4 kW / 5 HP | 5.5 kW / 7.5 HP |
| ATV310HU55N4E | 5.5 kW / 7.5 HP | 7.5 kW / 10 HP |
| ATV310HU75N4E | 7.5 kW / 10 HP | 11 kW / 15 HP |
| ATV310HD11N4E | 11 kW / 15 HP | 15 kW / 20 HP |
| ATV310HD15N4E | 15 kW / 20 HP | 18.5 kW / 25 HP |
| ATV310HD18N4E | 18.5 kW / 25 HP | 22 kW / 30 HP |
| ATV310HD22N4E | 22 kW / 30 HP | 30 kW / 40 HP |
A-version List (Same Power, Built-in EMC Filter, widely used in domestic projects)
Change suffix E → A, e.g.
ATV310H037N4A, ATV310H075N4A, ATV310HU15N4A … ATV310HD22N4A
Supplement: Another Altivar Easy Family Series ATV610 (High-power Easy Range)
ATV610 also belongs to Easy series, larger power range, 380–460 V three-phase, mainly for fan & pump applications
ATV610D11N4, ATV610D15N4, ATV610D18N4, ATV610D22N4, ATV610D30N4, ATV610D37N4, ATV610D45N4, ATV610D55N4, ATV610D75N4, ATV610D90N4, ATV610C11N4, ATV610C13N4, ATV610C16N4
General Common Parameters for Full ATV310 Range
Control: V/F + Sensorless Vector SVC
Communication: Standard Modbus RTU (RJ45)
I/O: 4DI, 1AI, 1 relay output
Protection: IP20, cabinet mounting
Application: Conveyors, fans, pumps, general OEM machinery
Selection Notes
- Heavy-duty applications (hoisting, extrusion, shock load) select according to HD rating; fans & pumps with smooth light load can use ND rating
- For export CE EMC compliance, select A (built-in EMC); E version requires external EMC filter
- Upgrade alternative: ATV320 (higher performance, encoder support, more expansion cards)
Schneider ATV310 (Altivar Easy) Application Selection Guide
Precondition: ATV310 is an economical open-loop vector VFD, no encoder interface, closed-loop vector not supported. Two capacity ratings: HD (Heavy Duty) / ND (Normal Duty). Suffix A=built-in EMC filter, E=no built-in EMC filter, three-phase 380~460 V.
Selection rule: Shock load, frequent start-stop, stall risk → select HD; fans & pumps with smooth light load → ND is acceptable
- Rated Current Quick Reference Table (Base Data)
| Model | HD Power | HD Continuous Current | ND Power | ND Continuous Current |
| ATV310H037N4 | 0.37 kW | 2.1 A | 0.55 kW | 2.7 A |
| ATV310H075N4 | 0.75 kW | 3.0 A | 1.1 kW | 4.2 A |
| ATV310HU15N4 | 1.5 kW | 4.1 A | 2.2 kW | 5.5 A |
| ATV310HU22N4 | 2.2 kW | 5.5 A | 3.0 kW | 7.2 A |
| ATV310HU30N4 | 3.0 kW | 7.2 A | 4.0 kW | 9.4 A |
| ATV310HU40N4 | 4.0 kW | 9.4 A | 5.5 kW | 11.7 A |
| ATV310HU55N4 | 5.5 kW | 11.7 A | 7.5 kW | 16.5 A |
| ATV310HU75N4 | 7.5 kW | 17.0 A | 11 kW | 22.8 A |
| ATV310HD11N4 | 11 kW | 24.0 A | 15 kW | 30.0 A |
| ATV310HD15N4 | 15 kW | 30.0 A | 18.5 kW | 37.0 A |
| ATV310HD18N4 | 18.5 kW | 37.0 A | 22 kW | 43.0 A |
| ATV310HD22N4 | 22 kW | 43.0 A | 30 kW | 57.0 A |
- Application Classification + Selection Scheme + Accessories Recommendation
Category 1: Centrifugal Fans & Centrifugal Pumps (Smooth Load, Quadratic Torque, ND Preferred)
Load characteristics: Low starting torque, stable operation, no shock; suitable for PID constant pressure / constant airflow, long continuous running
Selection rule: Select by ND power rating
Recommended suffix: A for export CE projects (built-in EMC); E for standard domestic cabinets with independent EMC solution
Accessories:
Braking resistor normally not required (coast stop acceptable)
Parameters: V/F quadratic curve, PID enable
Limitation: Large inertia smoke exhaust fans, high-temperature induced draft fans, suggest one size up, select HD
Example: 11 kW centrifugal pump → ATV310HU75N4A (ND=11 kW)
Category 2: General Conveyors, Belt Lines, Roller Tables (Constant Torque, Intermittent Start-Stop, HD Preferred)
Load characteristics: Constant torque, moderate starting resistance, frequent start-stop, occasional material jam shock
Selection rule: Strictly select by HD rating, motor rated current ≤ VFD HD current
Accessories:
Long deceleration, high inertia belt: add braking resistor
Multi-speed control uses built-in DI terminals directly, no expansion card required
Limitation: High-speed positioning, high-precision synchronization not suitable for ATV310, use ATV320 instead
Example: 7.5 kW belt conveyor → ATV310HU75N4A (HD=7.5 kW)
Category 3: Mixing Tanks, Mixers (High Starting Torque, Heavy Load)
Load characteristics: High starting torque, high resistance from tank media, high stall risk, constant torque
Selection rule: HD selection, reserve 1.1~1.2 safety margin; motor rated current ≤ 90% of VFD HD current
Accessories: Braking resistor for emergency stop; motor auto-tune recommended
High viscosity mixing: select one power size up
Example: 5.5 kW mixing motor → Prefer ATV310HU75N4 (HD 7.5 kW) for margin
Category 4: Screw Pumps, Gear Pumps, Positive Displacement Pumps (Constant Torque)
Load characteristics: Medium starting torque, pressure fluctuation, dry running prohibited
Selection rule: HD for normal operation; upsizing for heavy pressure fluctuation & frequent start-stop
Accessories: PID constant pressure, add pressure feedback AI
Example: 4 kW screw pump → ATV310HU40N4 (HD 4 kW)
Category 5: Woodworking Machinery, Grinders, General Machine Tool Spindles (Continuous Constant Torque)
Load characteristics: Continuous cutting, load fluctuation, stable torque requirement
Selection rule: HD selection; upsizing for heavy cutting shock
❌ Not applicable: Spindle positioning, rigid tapping, closed-loop control → ATV310 has no encoder support, use ATV320
Category 6: Lifting, Hoist, Winch, Hydraulic Main Pump ( ATV310 NOT Recommended)
Important Warning: ATV310 is economical open-loop vector VFD, no brake logic, no torque verification, no safety functions. NOT allowed for lifting applications. Hoisting duty requires ATV320 + safety relay or dedicated hoist VFD.
Category 7: Cooling Tower Fans, Roof Fans, Exhaust Fans (Light Load Quadratic Torque)
Selection: ND rating, best cost performance
Note: Ambient temperature below -10 °C requires cabinet heater, VFD derating applies
Cabinet for outdoor installation prefers A version built-in EMC to avoid interference
Category 8: Multi-motor Parallel Drive (Synchronous drag, multiple small motors)
Selection: Sum of all motor rated currents matched against HD current; motor auto-tune must be disabled, run in V/F mode
Accessories: Fit thermal relay for each motor for individual overload protection; output reactor recommended
- Suffix A / E Selection Judgment (EMC)
- ATV310…N4A (Built-in EMC Filter)
Suitable: EU CE export, control cabinet close to sensors, instruments, PLC communication cables, high EMC requirement
- ATV310…N4E (No Built-in EMC Filter)
Suitable: Standard domestic factory, power cables separated from signal wires, project procures separate external EMC filter; lower price
Risk: Direct operation may interfere with sensors, weighing instruments, RS485 communication
- Ambient Derating Rules
Ambient temperature 45~55 °C: HD rating no derating; >55 °C derating mandatory
Altitude >1000 m: derate 4% per additional 1000 m; ATV310 not recommended above 2000 m
Dust, corrosive gas: Enclosed cabinet + air conditioning required; standard ATV310 is 3C3 coated
- When to Upgrade from ATV310 to ATV320
Select ATV320 if any condition below applies:
- Encoder closed-loop control, high precision speed / positioning / synchronization required
- Safe torque off STO safety function required
- Multiple expansion cards needed (encoder card, Profinet/EtherNet/IP Ethernet card)
- Lifting, elevator, hoist loads
- Severe dynamic shock, fast torque response required
- Quick Selection Summary Table
| Application Type | Torque Characteristic | Recommended Rating | Recommended Suffix | Braking Resistor Suggested |
| Centrifugal Fan / Pump | Quadratic Torque | ND | A (Export) / E (Domestic) | No |
| Belt Conveyor, Roller Table | Constant Torque | HD | A / E | Yes for high inertia |
| Mixing, High Viscosity Blending | Constant Torque, High Starting Torque | HD + Upsize One Step | A | Yes for emergency stop |
| Positive Displacement Pump (Screw Pump) | Constant Torque | HD | A / E | Optional |
| General Machine Tool Spindle | Constant Torque with Fluctuation | HD | A | No |
| Multi-motor Parallel V/F Drive | Combined | Total Current Match HD | A | Optional |
Contactor,circuit breaker,sensor,Encoder,PLC,Converter




















NH42-63-318x560.png)