Inversor de frequência variável ABB ACS550-01-031A-4 (VFD)
This is an ABB ACS550 series three-phase VFD, avaliado em 15kW (Dever normal) / 11kW (Serviço Pesado), com corrente de saída nominal 31A. Ele é projetado para rede elétrica de 380-480V, montado na parede (IP21) recinto, controle vetorial integrado e filtro EMC. Adequado para aplicações industriais gerais, como bombas, ventiladores e transportadores.
- Model Breakdown Definition
| Segmento | Código | Descrição |
| ID da série | ACS550 | ABB standard low-voltage AC drive series for general-purpose applications |
| Tipo de Estrutura | 1 | Wall-mounted construction (IP21 protection rating), for standard industrial environments |
| Corrente nominal | 031UM | Nominal continuous output current 31A; corresponds to 15kW for normal duty / 11kW para serviço pesado |
| Classe de tensão | 4 | Suitable for three-phase 380-480V AC input power (+10/-15% voltage fluctuation tolerance) |
Product ID: 3AUA0000002418-D
Tamanho do quadro: R3
- Core Specification Parameter Table
| Categoria | Parâmetro | Avaliação | Observações |
| Basic Ratings | Corrente de saída nominal (I₂N) | 31UM | Continuous operation at 40℃ ambient |
| Normal Duty Power | 15kW | Standard 400V operating condition | |
| Heavy Duty Power | 11kW | Standard 400V operating condition | |
| Overload Capability | 1.1×I₂N (1 minute per 10 minutos) | For normal duty; 1.5×I₂hd for heavy duty | |
| Características Elétricas | Tensão de entrada | 3-phase 380-480V | Input frequency: 48-63Hz |
| Tensão de saída | 3-fase 0 ~ Input Voltage | Frequência de saída: 0-500Hz | |
| Modo de controle | Controle vetorial (Open-loop / Closed-loop) | Open-loop accuracy: 20% motor slip; Closed-loop accuracy: 0.1% of rated speed | |
| Frequência de comutação | 4kHz (Padrão) | Opcional: 1/2/4/8/12kHz | |
| Interface de E/S | Entrada Analógica | 2 canais (0-10V / 4-20mA) | Impedância de entrada: Tensão >312kΩ, Current 100Ω |
| Saída Analógica | 2 canais (4-20mA) | Max load <500Oh, Accuracy ±3% | |
| Entrada Digital | 6 canais | 24Em DC, PNP/NPN compatible | |
| Saída de relé | 3 canais | Max 250V AC / 30Em DC, Switching current 6A | |
| Interface de comunicação | Built-in RS485 (Modbus) | Support expansion of multiple fieldbuses | |
| Características Físicas | Classe de Proteção | IP21 | Configuração padrão; IP54 optional |
| Dimensões (L×A×P) | 270×600×450mm | R3 frame size | |
| Peso | Aprox.. 20.5kg | Basic configuration included | |
| Heat Dissipation | 457C | Air flow: 134m³/h | |
| Environmental Limits | Temperatura operacional | -15℃ ~ 50℃ | Derating required above 40-50℃ |
| Altitude | 0-1000eu (Full rating) | Derate 1% per 100m elevation increase | |
| Umidade | 5-95% (Non-condensing) | Compatível com IEC 721-3-3 |
- Standard Accessories & Optional Parts List
3.1 Standard Supplied Accessories
Assistant Control Panel (ACS-CP-D), with real-time clock and parameter modification record function
Built-in Class C2 EMC Filter (First Environment), meets basic EMC requirements
Mounting template for quick drilling position marking
Product manual and quick start guide
Standard I/O terminals and Modbus communication interface
3.2 Recommended Optional Parts
| Tipo | Modelo | Descrição da função | Cenário de aplicação |
| Control Panel | ACS-CP-C | Advanced control panel with parameter copy and multi-language support | Comissionamento & batch configuration for multiple VFDs |
| Braking Unit | ACS-BRK-D | Brake chopper + resistor (10.5, 7kW) | Frequent start-stop / fast deceleration applications |
| Reactor | LOCH0030-60 | Output reactor (41UM) | Suppress dv/dt when motor cable length >200eu |
| Módulo de Comunicação | Various Fieldbus | Profibus DP / DeviceNet / Ethernet/IP | Connection to PLC control system |
| Encoder Module | Opcional | Speed feedback to improve closed-loop control accuracy | High-precision speed control applications |
| Extended I/O | Opcional | Adicional 3 saídas de relé | Multi-status monitoring & control requirements |
- Cross-Brand Alternative Comparison Table
| Marca | Série | Modelo Equivalente | Key Parameter Matching | Descrição da diferença |
| Schneider | Altivar 610 | ATV610U15N4 | 15kW/31A/380-480V | Built-in PLC with higher integration |
| Siemens | SINAMICS G120C | 6SL3210-1PE21-8UL0 | 15kW/31A/380-480V | Modular design with strong expandability |
| Mitsubishi | FR-A840 | FR-A840-15K-NA | 15kW/31A/380-480V | High vector control accuracy, adequado para cargas complexas |
| Danfoss | VLT 2800 | 2840PT37T20H | 15kW/31A/380-480V | Econômico, ideal for fan & pump applications |
| ABB Alternative | ACS510 | ACS510-01-031A-4 | 15kW/31A/380-480V | Simplified version for fan/pump, without vector control |
- Diretrizes de seleção & Soluções Alternativas
5.1 Core Selection Principles
Current Priority: VFD rated current ≥ 1.1~1.3 times motor rated current, do not select only by power rating
Correspondência de carga:
Normal duty (Pump/Fan): Standard selection 15kW/31A
Serviço pesado (Compressor/Crusher): Recommend upgrade to 18.5kW (ACS550-01-038A-4) or higher frame
Adaptação Ambiental:
Temperatura >40℃: Derate 5~10% per 5℃ rise
Altitude >1000eu: Derate 1% por subida de 100 m
Dust environment: Select IP54 protection grade model
5.2 Recommended Alternative Solutions
| Cenário de aplicação | Recommended Solution | Descrição da vantagem |
| Standard General Purpose | ACS550-01-031A-4 | Built-in vector control, desempenho de alto custo |
| Fan & Pump Dedicated | ACS510-01-031A-4 | Energy-saving optimized algorithm, menor custo |
| High Precision Control | ACS550-01-031A-4 + Encoder Module | Closed-loop control, speed accuracy up to 0.1% |
| Heavy Duty Frequent Start-Stop | ACS550-01-038A-4 + ACS-BRK-D | Higher power margin + braking assembly, longer service life |
| Cost-Sensitive Project | Schneider ATV320U15N4 | Tamanho compacto, competitive price |
5.3 Instalação & Pontos-chave de manutenção
Cooling clearance reserved: 200mm top and bottom, no special requirement for left and right sides
Proteção de entrada: Recommended 35A gG fuse (UL Class T 40A)
Motor cable: Standard length ≤200m; install output reactor for longer distance
Ciclo de manutenção: Inspect cooling fan and capacitor condition after 10,000 horário de funcionamento
- ACS550 Series Full Power Model List (R3 Frame Size)
| Modelo | Corrente nominal | Normal Duty Power | Heavy Duty Power | Cenário de aplicação |
| ACS550-01-031A-4 | 31UM | 15kW | 11kW | Standard general load |
| ACS550-01-038A-4 | 38UM | 18.5kW | 15kW | Serviço pesado / Frequent start-stop |
| ACS550-01-045A-4 | 45UM | 22kW | 18.5kW | High-power general load |
The ACS550-01-031A-4 is a cost-effective general-purpose vector VFD, suitable for 15kW normal duty / 11kW heavy duty loads. With rich built-in functions and interfaces, it is widely used in general machinery requiring high control accuracy and reliability in industrial automation. Prioritize motor current matching during selection, and determine expansion modules or power upgrade according to load type and ambient conditions.
Complete Full Range Model List of ABB Variable Frequency Drives (Structured Version)
- Quick Overview of Model Naming Rules
ABB VFD adopts standard format: ACSxxx-xx-xxxX-xx, definition of each segment as below:
| Segmento | Significado | Exemplo | Descrição |
| ACSxxx | Código da série | ACS550/510/880 | Product positioning & application category |
| -xx | Structure Code | 01/04/31 | 01=Wall-mounted IP21; 04=Cabinet-type IP21; 31=Wall-mounted IP54 |
| -xxxX | Corrente nominal | 031A/125A | Numeric + letter for output current; A = Standard type |
| -xx | Classe de tensão | 2004/2/7 | 4=380-480V 3-phase; 2=200-240V 3-phase; 7=500-690V 3-phase |
- Main Series Overview (Sorted by Power Range)
| Série | Posicionamento | Faixa de potência | Aplicação Típica | Características |
| ACS150 | Economy Micro Drive | 0.37-4kW | Small pumps, fãs, rolling shutters | Single/3-phase universal, operação simples, IP20/IP21 |
| ACS355 | Compact General Drive | 0.37-15kW | Máquinas de embalagem, small conveyors | Built-in brake chopper, ampla faixa de tensão |
| ACS510 | Fan & Pump Dedicated | 0.75-160kW | Abastecimento de água com pressão constante, ventilador de resfriamento, AVAC | Energy-saving optimized algorithm, built-in PID, baixo custo |
| ACS550 | Enhanced General Drive | 0.75-355kW | Compressores, transportadores, misturadores | Controle vetorial, strong heavy-duty capability, built-in EMC |
| ACS580 | New Generation General Machinery Drive | 0.75-500kW | All kinds of industrial loads | Integrated safety functions, projeto modular, intelligent connection |
| ACS880 | Flagship High-Performance Drive | 0.75-2500kW | Controle de alta precisão, complex machinery | Full compatibility, alta confiabilidade, built-in safety functions |
| ACH550 | HVAC Dedicated | 0.75-355kW | Ar condicionado & ventilation systems | Building control protocol, comfort control algorithm |
- Detailed Model List by Series
3.1 Série ACS550 (Enhanced General Drive, IP21 Wall-mounted, 380-480V trifásico)
| Modelo | Corrente nominal | Normal Duty Power | Heavy Duty Power | Tamanho do quadro | Código do pedido |
| ACS550-01-003A-4 | 3UM | 0.75kW | 0.55kW | R1 | 3AUA0000002415-D |
| ACS550-01-004A-4 | 4UM | 1.1kW | 0.75kW | R1 | 3AUA0000002416-D |
| ACS550-01-006A-4 | 6UM | 1.5kW | 1.1kW | R1 | – |
| ACS550-01-009A-4 | 9UM | 4kW | 3kW | R1 | – |
| ACS550-01-012A-4 | 12UM | 5.5kW | 4kW | R1 | – |
| ACS550-01-015A-4 | 15UM | 7.5kW | 5.5kW | R2 | – |
| ACS550-01-019A-4 | 19UM | 11kW | 7.5kW | R2 | – |
| ACS550-01-023A-4 | 23UM | 11kW | 10kW | R2 | 3AUA0000002417-D |
| ACS550-01-031A-4 | 31UM | 15kW | 11kW | R3 | 3AUA0000002418-D |
| ACS550-01-038A-4 | 38UM | 18.5kW | 15kW | R3 | – |
| ACS550-01-045A-4 | 45UM | 22kW | 18.5kW | R3 | – |
| ACS550-01-057A-4 | 57UM | 30kW | 22kW | R4 | – |
| ACS550-01-072A-4 | 72UM | 37kW | 30kW | R4 | – |
| ACS550-01-09A4-4 | 94UM | 45kW | 37kW | R5 | – |
| ACS550-01-125A-4 | 125UM | 55kW | 45kW | R5 | 3ABD68589657 |
| ACS550-01-157A-4 | 157UM | 75kW | 55kW | R6 | – |
| ACS550-01-180A-4 | 180UM | 90kW | 75kW | R6 | – |
| ACS550-01-210A-4 | 210UM | 110kW | 90kW | R7 | – |
| ACS550-01-250A-4 | 250UM | 132kW | 110kW | R7 | – |
| ACS550-01-290A-4 | 290UM | 160kW | 132kW | R8 | – |
| ACS550-01-340A-4 | 340UM | 185kW | 160kW | R8 | – |
| ACS550-01-400A-4 | 400UM | 200kW | 185kW | R9 | – |
3.2 ACS510 Series (Fan & Pump Dedicated, IP21 Wall-mounted, 380-480V trifásico)
| Modelo | Corrente nominal | Poder | Tamanho do quadro |
| ACS510-01-003A3-4 | 3.3UM | 1.1kW | R1 |
| ACS510-01-004A1-4 | 4.1UM | 1.5kW | R1 |
| ACS510-01-005A6-4 | 5.6UM | 2.2kW | R1 |
| ACS510-01-007A2-4 | 7.2UM | 3kW | R1 |
| ACS510-01-009A4-4 | 9.4UM | 4kW | R1 |
| ACS510-01-012A5-4 | 12.5UM | 5.5kW | R1 |
| ACS510-01-015A6-4 | 15.6UM | 7.5kW | R2 |
| ACS510-01-019A0-4 | 19.0UM | 11kW | R2 |
| ACS510-01-024A1-4 | 24.1UM | 15kW | R3 |
| ACS510-01-030A8-4 | 30.8UM | 18.5kW | R3 |
| ACS510-01-038A0-4 | 38.0UM | 22kW | R3 |
| ACS510-01-045A0-4 | 45.0UM | 30kW | R4 |
| ACS510-01-057A0-4 | 57.0UM | 37kW | R4 |
| ACS510-01-072A0-4 | 72.0UM | 45kW | R5 |
| ACS510-01-09A4-4 | 94.0UM | 55kW | R5 |
3.3 Série ACS880 (Flagship High-End Drive, Partial Models)
| Modelo | Tipo de Estrutura | Corrente nominal | Poder | Classe de tensão | Características |
| ACS880-01-003A-4 | Wall-mounted IP21 | 3UM | 0.75kW | 380-480V | Compact type |
| ACS880-01-031A-4 | Wall-mounted IP21 | 31UM | 15kW | 380-480V | Controle vetorial |
| ACS880-31-145A-3 | Wall-mounted IP54 | 145UM | 75kW | 380-480V | À prova de poeira & impermeável |
| ACS880-04-271A-7 | Cabinet-type IP21 | 271UM | 160kW | 500-690V | High power density |
| ACS880-07-0450A-7 | Cabinet-type IP21 | 450UM | 315kW | 500-690V | Projeto modular |
3.4 Selected Models of Other Common Series
| Série | Modelo | Poder | Tensão | Aplicativo |
| ACS355 | ACS355-03E-04A7-4 | 1.5kW | 380-480V | Small machinery |
| ACS355-03E-12A5-4 | 5.5kW | 380-480V | Packaging equipment | |
| ACS150 | ACS150-03E-03A3-4 | 1.1kW | 380-480V | Small pumps |
| ACS150-01E-02A4-2 | 0.75kW | 200-240V | Single-phase power supply | |
| ACH550 | ACH550-01-031A-4 | 15kW | 380-480V | HVAC system |
| ACH550-01-125A-4 | 55kW | 380-480V | Large air conditioning | |
| ACS580 | ACS580-01-04A5-4 | 2.2kW | 380-480V | General machinery |
| ACS580-01-320A-4 | 160kW | 380-480V | Heavy-duty load |
- Notas de seleção de chave
- Current Priority Principle: VFD rated current ≥ 1.1~1.3 times motor rated current; do not select merely by power rating.
- Correspondência de tipo de carga:
Fan / Bombear: Escolha ACS510 / ACS380 for better energy saving
Constant torque / Serviço pesado: Choose ACS550 / ACS880 for stronger overload capability
HVAC dedicated: Choose ACH550 with built-in building control protocol
- Adaptação Ambiental:
Dust environment: Select IP54 protection grade (por exemplo. ACS880-31 series)
High temperature environment: Derating required above 40℃, derate 5~10% per 5℃ rise
Altitude >1000eu: Derate 1% per 100m elevation increase
- Model Extension Rules
Basic model can be extended with +option code for additional functions, examples:
ACS550-01-031A-4+J400: Add Profibus DP communication module
ACS550-01-031A-4+K454: Add brake chopper
ACS550-01-031A-4+L501: Add output reactor
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares





















NH42-63-318x560.png)