ABB ESB20-20N-06 contator - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

ABB ESB20-20N-06 contator - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

contator/

ABB ESB20-20N-06 contator

ABB ESB20-20N-06 Technical Analysis Report This is a 2-pole, 20UM, 2NÃO, 230V AC/DC universal coil modular installation contactor, suitable for single-phase load control in residential and industrial environments. It features silent operation, baixo consumo de energia, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620. Modelo ...

  • Detalhes do produto

ABB ESB20-20N-06 Technical Analysis Report

This is a 2-pole, 20UM, 2NÃO, 230V AC/DC universal coil modular installation contator, suitable for single-phase load control in residential and industrial environments. It features silent operation, baixo consumo de energia, and integrated overvoltage protection, with a width of only 18mm and standard 35mm DIN rail mounting. Order code: 1SBE121111R0620.

  1. Análise do modelo
Segmento de modeloDescrição
ESBProduct family: ABB ESB series building / installation contactors
20Corrente nominal: 20UM (AC-1 duty)
20Configuração de contato principal: 2 NÃO, 0 NC
NFamily identifier: Standard ESB..N installation contactor (contra. EN..N with manual switch)
6Código de tensão da bobina: 230V AC/DC universal
  1. Especificações principais

Dados elétricos

ItemValorNotas
Corrente operacional nominal (AC-1)20UMCarga resistiva
Rated operational power (AC-7a, 230V)4.6kWSingle-phase motor load
Corrente operacional nominal (AC-3, 230V)9UMSingle-phase motor load
Tensão nominal de isolamento (interface do usuário)400VCompatível com IEC
Tensão nominal suportável de impulso (Um)6kVCompatível com IEC
Tensão da bobina230V CA/CCUniversal, no polarity required
Coil powerInrush: ~12VA/10WLow-power, energy-saving design
Selado: ~2VA/2W
Control circuit frequency50/60HzUniversal range

Mecânico & Dados Ambientais

ItemValorNotas
Número de pólos22 circuitos principais
Configuração de contato2NÃO + 0NCSem contatos auxiliares
Durabilidade mecânica1,000,000 operaçõesHigh endurance
Durabilidade elétrica (AC-7a/7b)150,000 operaçõesCEI 60947-4-1 compliant
Largura18milímetrosModular, economia de espaço
Montagem35mm trilho DINStandard mounting
Temperatura operacional-25°C ~ +55°CWide temperature range
Temperatura de armazenamento-40°C ~ +85°CHigh-reliability design
Grau de proteçãoIP20Seguro para os dedos, suitable for distribution boards
  1. Descrição da função
  2. Universal coil technology: AC/DC universal coil, no AC/DC distinction, flexible installation, completely silent and vibration-free operation.
  3. Integrated overvoltage protection: Built-in overvoltage suppression in control circuit, improves system reliability and service life.
  4. Projeto modular: Only 18mm wide, fully compatible with other modular DIN rail components, economiza espaço no armário.
  5. Compatibilidade de acessórios: Supports standard accessories (contatos auxiliares, intertravamentos mecânicos, etc.), tool-free plug-and-play installation.
  6. Safety design: Complies with EN/IEC/UL standards, provides reliable electrical isolation for personnel and equipment safety.
  7. Ampla aplicação: Suitable for controlling electric heaters, hot water systems, pump/fan motors, lighting and other single-phase loads.
  8. Recomendações de seleção

Aplicações adequadas

Iluminação, aquecimento, ventilation control in residential and commercial buildings

Single-phase motor control (bombas, fãs) for small industrial equipment

Noise-sensitive environments (hospitais, escritórios, homes)

Space-limited distribution boards / armários de controle

Selection Criteria

  1. Load type matching:

Carga resistiva (AC-1): Use 20A rated current directly

Motor load (AC-7a/7b): Recommended ≤9A (4.6kW) at 230V single-phase

Inductive load: Derating or surge suppressor recommended

  1. Coil voltage selection:

Match control system supply (230V CA/CC)

Other voltages available: ESB20-20N-01 (24V), ESB20-20N-04 (110V)

  1. Configuração de contato:

This model: 2NÃO, suitable for two independent circuits

For NC contacts: ESB20-02N series (2NC)

For auxiliary contacts: Add auxiliary contact modules

  1. Condições ambientais:

Derate above +40°C ambient temperature

Extra protection required in humid or corrosive environments

  1. Notas de instalação

Pre-Installation

Verify model matches order, inspect for physical damage

Confirm coil voltage matches control supply

Prepare standard 35mm DIN rail and suitable terminals

Procedimento de instalação

Clip contactor firmly onto 35mm DIN rail

Wire main and control circuits per diagram; coil is non-polarized

Torque terminal: 2.5N·m (conductor: 0.5–2.5mm²)

Accessories clip directly onto top/side without tools

Segurança

Isolate and verify voltage-free before installation

Separate main and control wiring to avoid interference

Ensure adequate ventilation to prevent overheating

Maintain ≥5mm clearance around contactor for heat dissipation

Comissionamento & Manutenção

Check wiring before first energization

Test contactor operation for correct switching and no abnormal noise

Inspect contacts and terminal tightness regularly (at least annually)

  1. Modelos Alternativos

Same-Series Alternatives

ModeloDiferençaAplicativo
ESB20-20N-0124V AC/DC coilLow-voltage control systems
ESB20-20N-04110V AC/DC coil110V control systems
ESB20-02N-062NC configurationApplications requiring normally closed contacts
EN20-20N-06With manual operatorEmergency manual control

Upgraded Alternatives

ModeloAtualizarAplicativo
ESB25-20N-0625Uma corrente nominalHigher load requirements
ESB40-40N-064-pólo, 40UMThree-phase or higher current
ABB AF seriesIndustrial contactorsHeavy-duty industrial environments

ABB ESB20-20N-06 is a compact, high-performance installation contactor. With silent operation, universal coil, low power consumption and modular design, it is an ideal solution for single-phase load control in residential and industrial applications. Proper selection, installation and maintenance ensure long-term reliable performance and safe, efficient control for electrical systems.

ABB Contactor Standard Selection Procedure

(Industrial & Building, for sales / cotação / design)

Using ESB (building) and AF/A (industrial) as examples – 8-step precise selection ready for proposals and quotations.

  1. Define Application & Product Family

Building / residencial / Distribution board: Iluminação, aquecimento, bombas, fãs, small motors → ESB/EN series (silencioso, Trilho DIN, narrow width)

Industrial / Equipamento / Control cabinet: Fãs, bombas, compressores, motor main circuits → AF/A series (ampla tensão, longa vida, serviço pesado)

  1. Determine Load Category (Critical for Derating)

Per IEC 60947 utilization categories:

AC-1: Cargas resistivas (aquecedores, iluminação) → use rated current directly

AC-3: Squirrel-cage motor DOL (most common industrial) → motor current ≤ contactor rated current

AC-7a/7b: Building small motors, fãs, pumps → use building contactor rated values

  1. Calculate Operating Current & Capacidade nominal
  2. Determine current from power / tensão
  3. Allow 1.1–1.25x safety margin (irrupção, continuous duty)
  4. Select corresponding rated current (Ou seja) from ABB catalog

Exemplo: 230V single-phase 2kW heater ≈ 8.7A → ESB20-20N is sufficient

  1. Select Number of Poles

1P: Monofásico, single circuit

2P: Monofásico, double-pole (L+N switching, building standard)

3P: Motores trifásicos / industrial (most common)

4P: Trifásico + N or double-break

  1. Select Coil Voltage & Tipo
  2. Tensão de controle: 24V, 110V, 230V, 400V, etc..
  3. Coil type:

Building: AC/DC universal coil (ESB series, non-polar, silencioso)

Industrial: Wide-range coil (AF series, stable at 85–110% Un)

  1. Define Auxiliary Contact Requirements

Integrado: From model (20=2NO, 02=2NC)

Expandable: EH series auxiliary contacts (1NÃO+1NC, 2NÃO, etc.)

Used for: Status feedback, interlocking, sequential control

  1. Ambiental & Requisitos Especiais

Altitude >1000eu, temperatura >40°C → derate or upsize

Silent requirement (residential/office): Must use ESB silent type

Proteção: IP20 normally sufficient for panel mounting

Mechanical interlock / reversing: Use dedicated interlock accessories

  1. Final Verification: Modelo + Certificações
  2. Confirm full model: family–current–contacts–coil

Exemplo: ESB20-20N-06

  1. Verify certifications: CCC, CEI, RoHS
  2. Confirm mounting: 35mm trilho DIN / montagem com parafuso

Simplified Selection Mnemonic

  1. Choose family by application
  2. Choose duty by load type
  3. Calculate current with margin
  4. Confirm poles and coil voltage
  5. Add aux contacts for control
  6. Check environment and derate
  7. Verify model for final list

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado