M1M: ABB M1M Series Motor Protection and Management Unit (Motor Protection Controller)
2TAZ664052R0007: Corresponding ABB original order number / material code
- Tipo de produto
Low-voltage three-phase motor integrated protection relay, used for motor protection, monitoring and basic control.
- Funções principais
Sobrecarga, locked-rotor, and underload protection
Phase sequence, perda de fase, and phase imbalance protection
Earth fault / earth leakage protection
Motor operating status monitoring and fault output
- Same Series & Modelos Alternativos
Same series: Full ABB M1M series (M1M 01/02/03 and other current ratings)
Upgraded alternatives: ABB M102 / M2M series (functionally compatible with enhanced performance)
Cross-brand alternatives: Siemens 3RB series, Schneider EOCR series motor protection relays
- Aplicações Típicas
Protection for three-phase asynchronous motors such as industrial fans, bombas de água, transportadores, e compressores, as well as automated production lines and factory low-voltage power distribution systems.
ABB M1M Series Digital Multifunction Power Meters
- Significado do modelo & Posicionamento do produto
Análise do modelo
M1M: ABB System pro M Series Digital Multifunction Power Meters (not motor protectors; please distinguish carefully)
Suffix numbers: Product function level (10/12/15/20/30); higher numbers indicate richer functions
Complete model example: M1M-2TAZ664052R0007 (2TAZ664052R0007 is the ABB original order number / material code)
Posicionamento do produto
ABB’s new-generation modular DIN-rail mounted multifunction power monitoring meters, used for energy metering, análise de qualidade de energia, and electrical parameter monitoring in mediumand low-voltage primary and secondary distribution systems. Supports Modbus communication and is suitable for industrial and building applications.
- Full Series Comparison
| Modelo | Funções principais | Interface de comunicação | I/O | Tensão de alimentação | Sample Order No. |
| M1M 10 | Basic energy measurement, no display | None | None | No auxiliary power required | 2TAZ661010R2000 |
| M1M 12 | Basic energy measurement, LED indication | None | None | No auxiliary power required | 2TAZ661210R2000 |
| M1M 15 | Multifunction measurement, LCD display | Optional Modbus | None | 100–230V AC/DC | 2TAZ661510R2000 |
| M1M 20 | Multifunction measurement, LCD display | Optional Modbus | None | 100–230V AC/DC | 2TAZ662010R2000 |
| M1M 30 | Advanced measurement, análise de qualidade de energia | Optional Modbus/Ethernet | Optional 2DI/2DO | 100–230V AC/DC | 2TAZ663010R2000 |
| M1M 30 I/O | Advanced measurement + I/O control | Modbus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ663012R2001 |
| M1M 30 Ethernet | Advanced measurement + Ethernet | Modbus TCP/IP | None | 100–230V AC/DC | 2TAZ663011R2001 |
- Especificações técnicas (M1M 30 Série)
Measurement accuracy: Current/voltage class 0.2, active energy class 0.5S (compatível com IEC 62053-22), reactive energy class 2
Measured parameters: Three-phase voltage/current, active/reactive/apparent power, power factor, freqüência, energy metering (forward/reverse), harmonic analysis (selected models)
CT input: Standard 1A/5A, supports star (3E) or delta (2E) connection
Ingress protection: IP51 (front panel), IP20 (terminais)
Montagem: 35mm trilho DIN, 18mm width (1 módulo)
- Cenários de aplicativos principais
- Sub-metering in commercial buildings (iluminação, AVAC, power circuits)
- Power distribution system monitoring and energy efficiency analysis in industrial plants
- Power quality monitoring in data centers
- Real-time electrical parameter monitoring in low-voltage distribution cabinets
- Power generation metering for renewable energy systems (VP / energia eólica)
- Modelos Alternativos & Brand Comparison
Upgraded Alternatives (Same Brand)
Function expansion: ABB M2M series (higher accuracy, more communication protocols)
Basic version: ABB M1M 10/12 (basic energy metering, menor custo)
Cross-Brand Alternatives
| Marca | Recommended Replacement | Notas de compatibilidade |
| Schneider | PowerLogic PM5000 series | Similar functions, compatible communication protocols |
| Siemens | SENTRON PAC series | Comparable measurement accuracy, supports Modbus |
| Domestic alternatives | Acrel PZ series, Chint DTSU series | Cost advantage, compatible basic functions |
- Selection Guidelines
- Measurement needs: Basic energy metering → M1M 10/12; real-time monitoring → M1M 15/20; power quality analysis → M1M 30
- Communication needs: Remote monitoring → models with Modbus (M1M 15/20/30)
- Control needs: Digital input/output required → M1M 30 I/O
- Installation environment: Ensure operating temperature range (-25°C to +55°C) and protection class requirements
Complete List of ABB Multifunction Power Meters
This list covers ABB’s mainstream multifunction power meter series, sorted from basic metering to advanced power quality analysis by product positioning. Includes model numbers, core functions, parâmetros técnicos, order numbers, and application scenarios for easy selection and procurement reference.
- M1M Series (System pro M, Modular DIN-Rail Mounted)
ABB’s new-generation compact multifunction power meters for mediumand low-voltage primary and secondary distribution systems. Only 18mm wide (1 módulo) and supports hot-swap.
I.1 Basic Metering Type (No Display / LED Indication)
| Modelo | Funções principais | Classe de Precisão | Comunicação | I/O | Fonte de energia | Sample Order No. | Aplicativo |
| M1M 10 | Three‑phase energy measurement (no display) | Active 0.5S, Reactive 2 | None | None | No auxiliary power | 2TAZ661010R2000 | Basic energy statistics, low‑cost applications |
| M1M 12 | Three‑phase energy measurement (LED status indication) | Active 0.5S, Reactive 2 | None | None | No auxiliary power | 2TAZ661210R2000 | Simple circuit monitoring, fault indication |
I.2 Multifunction Display Type (LCD Display)
| Modelo | Funções principais | Classe de Precisão | Comunicação | I/O | Fonte de energia | Sample Order No. | Aplicativo |
| M1M 15 | Three‑phase full‑electrical measurement, LCD display | Active 0.5S, Reactive 2 | Optional Modbus RTU | None | 100–230V AC/DC | 2TAZ661512R2000 | Sub‑metering in commercial buildings, industrial monitoring |
| 10239994 | |||||||
| M1M 15 I/O | Full‑electrical measurement + 2DI/2DO | Active 0.5S, Reactive 2 | Modbus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ661512R2001 | Local alarm/control, equipment interlock |
| M1M 20 | Full‑electrical + THD measurement, LCD display | Active 0.2S, Reactive 2 | Optional Modbus RTU | None | 100–230V AC/DC | 2TAZ662012R2000 | Industrial energy efficiency analysis, power quality monitoring |
| 10239996 | |||||||
| M1M 20 I/O | Full‑electrical + THD + 2DI/2DO | Active 0.2S, Reactive 2 | Modbus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ662012R2001 | Local control, alarm output |
| M1M 20 Ethernet | Full‑electrical + THD + Ethernet | Active 0.2S, Reactive 2 | Modbus TCP/IP | None | 100–230V AC/DC | 2TAZ662014R2000 | Network integration, monitoramento remoto |
I.3 Advanced Power Quality Type
| Modelo | Funções principais | Classe de Precisão | Comunicação | I/O | Fonte de energia | Sample Order No. | Aplicativo |
| M1M 30 | Full‑electrical + harmonic analysis (up to 40th), data logging | Active 0.2S, Reactive 2 | Optional Modbus RTU | None | 100–230V AC/DC | 2TAZ663012R2000 | Power quality analysis, energy optimization |
| 10239997 | |||||||
| M1M 30 I/O | Funções completas + 2DI/2DO | Active 0.2S, Reactive 2 | Modbus RTU | 2DI/2DO | 100–230V AC/DC | 2TAZ663012R2001 | Local control + alarm, equipment interlock |
| M1M 30 Ethernet | Funções completas + Ethernet | Active 0.2S, Reactive 2 | Modbus TCP/IP | None | 100–230V AC/DC | 2TAZ663014R2000 | Remote power quality monitoring, system integration |
| M1M 30 I/O Ethernet | Funções completas + 2DI/2DO + Ethernet | Active 0.2S, Reactive 2 | Modbus RTU/TCP | 2DI/2DO | 100–230V AC/DC | 2TAZ663014R2001 | Smart power distribution systems, energy management |
Special model: M1M-2TAZ664052R0007 (custom version of M1M series, order no. 2TAZ664052R0007), functions equivalent to M1M 30, for specific project requirements.
- M2M Series (System pro M compact, Panel Mounted)
ABB mid-range power quality analyzers, 96mm wide (4 módulos), suitable for mounting on distribution cabinet doors. Fully functional with advanced power quality analysis.
| Modelo | Funções principais | Classe de Precisão | Comunicação | I/O | Harmonic Analysis | Data Logging | Sample Order No. | Aplicativo |
| M2M 10 | Full‑electrical measurement, LCD display | Active 0.2S, Reactive 2 | Modbus RTU | 2DI/2DO | Up to 31st | Basic logging | 2CSG299883R4052 | Industrial power monitoring, energy efficiency analysis |
| M2M 20 | Power quality analysis, event recording | Active 0.1S, Reactive 2 | Modbus RTU/TCP | 4DI/4DO | Up to 40th | Advanced logging | 2CSG299884R4052 | Critical load monitoring, fault diagnosis |
| M2M 30 | Advanced power quality, PQDIF export | Active 0.05S, Reactive 2 | Modbus RTU/TCP | 8DI/8DO | Up to 63rd | Comprehensive logging | 2CSG299885R4052 | Centros de dados, critical production equipment |
| Ethernet/IP |
III. M4M Series (Network Analyzers)
ABB high-end power quality analyzers, standalone installation, for mediumand high-voltage distribution systems, providing complete power quality analysis and energy management.
| Modelo | Funções principais | Classe de Precisão | Comunicação | I/O | Harmonic Analysis | Data Logging | Aplicativo |
| M4M 100 | Full parameter measurement, análise de qualidade de energia | Active 0.02S, Reactive 1 | Modbus RTU/TCP | 16DI/16DO | Up to 63rd | Large‑capacity storage | Medium‑/high‑voltage distribution, grid monitoring |
| DNP3 | |||||||
| M4M 200 | Advanced power quality, power quality reporting | Active 0.01S, Reactive 1 | Modbus RTU/TCP | 24DI/24DO | Up to 127th | Massive storage | Grid custody metering, power trading |
| DNP3 | |||||||
| CEI 61850 |
- D1M Series (System pro M Distributed Monitoring)
ABB distributed power monitoring system supporting centralized monitoring of multiple circuits, ideal for large buildings and industrial plants, with remote management via gateways.
| Modelo | Funções principais | Monitored Circuits | Comunicação | I/O | Fonte de energia | Aplicativo |
| D1M 10 | Centralized monitoring of 4 circuits | 4×three‑phase | Modbus RTU | 8DI/4DO | 24V DC | Edifícios comerciais, multi‑story plants |
| D1M 20 | Centralized monitoring of 8 circuits | 8×three‑phase | Modbus RTU/TCP | 16DI/8DO | 24V DC | Large shopping malls, industrial parks |
- EM Series (Smart Power Meters)
ABB economical multifunction power meters for small buildings and industrial applications, cost-effective and flexible installation.
| Modelo | Funções principais | Classe de Precisão | Comunicação | I/O | Fonte de energia | Aplicativo |
| EM 20 | Single‑phase current/voltage measurement | Active 1, Reactive 2 | None | None | No auxiliary power | residencial, pequenas lojas |
| EM 100 | Single‑phase full‑electrical measurement | Active 0.5S, Reactive 2 | Optional Modbus | 2DI/2DO | 100–230V AC/DC | Small commercial, lighting circuits |
| EM 200 | Three‑phase full‑electrical measurement | Active 0.5S, Reactive 2 | Optional Modbus | 4DI/4DO | 100–230V AC/DC | Small factories, edifícios de escritórios |
| EM 400 | Three‑phase full‑electrical + saída analógica | Active 0.2S, Reactive 2 | Optional Modbus | 4DI/4DO | 100–230V AC/DC | Process control, equipment interlock |
| 2AO |
- Other Series (Special Applications)
| Série | Modelo | Funções principais | Cenários de aplicação |
| IM Series | IM302 | Smart power monitoring, event recording | Industrial automation, equipment monitoring |
| LNP3 Series | LNP301 | Energy metering, remote meter reading | Public utilities, smart grids |
| PMU Series | PMU6000 | Multifunction measurement, análise de qualidade de energia | Large‑scale industry, energy management |
VII. Guia de seleção (By Application)
- Basic energy metering: Choose M1M 10/12 or EM 20/100, baixo custo, meets basic statistical needs
- General power monitoring: Choose M1M 15/20 or M2M 10, full functions, supports Modbus communication
- Power quality analysis: Choose M1M 30 or M2M 20/30, harmonic analysis up to 40th/63rd, supports event recording
- Medium-/high-voltage distribution: Choose M4M series, high-accuracy measurement, complete power quality analysis, supports IEC 61850
- Multi-circuit centralized monitoring: Choose D1M series, distributed architecture, reduces wiring and costs-
VIII. Core Technical Parameter Comparison
| Série | Measurement Accuracy | Harmonic Analysis | Communication Protocols | I/O Capacity | Montagem | Largura |
|---|---|---|---|---|---|---|
| M1M | 0.5S ~ 0.2S | Up to 40th | Modbus RTU/TCP | 0~2DI/2DO | DIN rail | 18milímetros |
| M2M | 0.2S ~ 0.05S | Up to 63rd | Modbus RTU/TCP Ethernet/IP | 2~8DI/DO | Panel mount | 96milímetros |
| M4M | 0.02S ~ 0.01S | Up to 127th | Modbus RTU/TCP DNP3 CEI 61850 | 16~24DI/DO | Standalone / 19″ rack | 19″ |
| D1M | 0.5S | Up to 31st | Modbus RTU/TCP | 8~16DI/DO | DIN rail | 72milímetros |
| EM | 0.5S ~ Class 1 | Up to 15th | Optional Modbus | 0~4DI/DO | DIN rail | 36milímetros |
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares


















NH42-63-318x560.png)