ABB S201M-C16 Miniature Circuit Breaker - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 ABB S201M-C16 Miniature Circuit Breaker - Contator,disjuntor,sensor,Codificador,CLP,Conversor

disjuntor/

ABB S201M-C16 Miniature Circuit Breaker

Ordering code:2CDS271001R0164 / Domestic material number:10111809 Série: S200M (10kA high breaking capacity type), Montagem em trilho DIN, viagem termomagnética, AC/DC compatible ✅ Model Interpretation S200: S200 series miniature circuit breaker 1: 1 pólo (1P) M: Breaking capacity class M, Icn=10kA @230V AC C: C-curve trip (5~10In instantaneous trip, adequado para iluminação, general sockets and small inductive ...

  • Detalhes do produto

Ordering code:2CDS271001R0164 / Domestic material number:10111809

Série: S200M (10kA high breaking capacity type), Montagem em trilho DIN, viagem termomagnética, Compatível com CA/CC

✅ Model Interpretation

S200: S200 series disjuntor miniatura

1: 1 pólo (1P)

M: Breaking capacity class M, Icn=10kA @230V AC

C: C-curve trip (5~10In instantaneous trip, adequado para iluminação, general sockets and small inductive loads)

16: Rated current In=16A

📋 Core Electrical Specifications

Corrente nominal In: 16 UM

Curva de viagem: Curva C

Tensão nominal: CA 230/400 V; Máx.. DC 72V

Rated short-circuit breaking capacity Icn: 10 o (230V e)

Capacidade final de interrupção de curto-circuito Icu: 15 kA @230V AC

Service short-circuit breaking capacity Ics: 7.5 kA @230V AC

Tensão nominal suportável de impulso Uimp: 4 kV (6.2kV at sea level)

Dissipação de energia: 2.5 W per pole

Freqüência: 50/60Hz

Energy limitation class: Aula 3

Padrões: IEC/EN 60898-1, IEC/EN 60947-2

📐 Construction & Instalação

Dimensões: 17.5 milímetros (C) ×88 mm (H) ×69 mm (D), 1 largura do módulo

terminal: Terminal de parafuso; Máx.. solid conductor 25mm², Máx.. flexible conductor 16mm²

Entrada de cabo: Top or bottom feeding, sem exigência de polaridade

Indicador de status: Red = ON, Green = OFF

Grau de proteção: IP20 for bare unit; IP40 with front cover

Endurance: Electrical operation 20,000 ciclos, Operação mecânica 20,000 ciclos

Temperatura operacional: -25℃ ~ +55℃

🛠️ Aplicações típicas

Commercial power distribution, branch circuits inside industrial control cabinets

Circuitos de iluminação, circuitos de tomadas gerais, fãs, solenoid valves and other inductive loads with low starting current

Not suitable for direct-on-line motor starting (alta corrente de partida; D-curve or contator configuration is preferred)

Compatível com ABB auxiliary contact S2C-H, liberação de derivação / undervoltage release accessories

🆚 In-series Comparison & Referência Alternativa

  1. S201-C16: Versão padrão, Icn=6kA, menor capacidade de interrupção
  2. S201M-C16: 10o, widely used inside industrial cabinets (este modelo)
  3. S201P-C16: 25kA higher breaking capacity
  4. SH201-C16: Economical residential type, 6o, for building wiring

Domestic equivalent alternatives: Schneider iC65N-C16 (6o), iC65H-C16 (10o); Chint NM6, Delixi CDB6H 1P C16 10kA

⚠️ Notas importantes

C-curve instantaneous trip at 5~10In; nuisance tripping may occur for heavy inrush loads, switch to D-curve for such cases

DC breaking capacity is derated when used on DC circuits; verify DC breaking rating before selection

Can be assembled with residual current block to form RCBO: S201M + DS201 module solution

Posicionamento central: 1P, Curva C, 10kA alta capacidade de interrupção, suitable for civil, commercial and OEM control cabinet branch circuits; C-curve matches general lighting, sockets and small inductive loads

🏭 Industrial Automation (Mais Comum)

  1. 220V branch supply circuits in PLC cabinets, VFD cabinets and HVAC DDC cabinets
  2. Válvulas solenóides, pequenos fãs, ventiladores de resfriamento, 220V power supplies and sensor power circuits
  3. Internal power distribution for production lines, máquinas de embalagem, test jigs and custom automation equipment
  4. Auxiliary control circuits for machine tools (not for direct motor startup; select D-curve for DOL motors)
  5. AC auxiliary circuits for photovoltaic systems (max DC 72V for standard unit; use UC variant for high DC voltage)

🏢 Commercial & Edifícios Públicos

  1. Lighting and general socket circuits in office buildings, shoppings, hotels and exhibition centers
  2. Power distribution for computer rooms, gabinetes de corrente fraca, monitoring boxes, access control and public address systems
  3. Fan coil and fresh air control circuits for central air conditioning
  4. Terminal distribution boxes in hospitals, laboratories and libraries (10kA breaking capacity for locations with high prospective short-circuit current)

🏠 Residential & High-end Buildings

  1. Sub-distribution boxes for large apartments and villas, basement power distribution (higher short-circuit withstand than standard 6kA MCBs)
  2. Auxiliary control circuits for EV chargers and home energy storage AC side (main circuit shall be calculated separately)

🚢 Infrastructure & Special Industry (With Marine Certifications)

  1. Cabin lighting and instrument control circuits on vessels and offshore platforms (CCS, DNV approvals available)
  2. Electromechanical cabinets for railway stations, tunnel electromechanical systems and pump stations
  3. 220V power protection inside telecom base stations and outdoor integrated cabinets

🧩 OEM Complete Equipment

Power distribution cabinets, EPS/UPS cabinets, unidades de tratamento de ar, purification equipment, dehumidifiers and printing machines. Popular model for ABB OEM partners. Auxiliary contact S2C-H can be fitted for status feedback; RCBO configuration available with residual current block.

✅ Suitable Load Types (C-curve 5~10In Instantaneous Trip)

✅ Incandescent lamps, Iluminação LED, general sockets

✅ Switching power supplies, small relays, válvulas solenóides

✅ Small fans, fan coil motors (low starting current)

❌ Not suitable for direct starting of large motors and high inrush loads (risk of nuisance tripping; select S201M-D16 D-curve)

  1. Regra de codificação do modelo (Take S201M-C16 as Example)

S201M-C16

  1. S200 = Series
  2. 1 = Pole: 1=1P, 2=2P, 3=3P, 4=4P, 1+NA=1P+N
  3. M = Breaking class

Sem sufixo: 6o (padrão)

M: 10o (industrial preferred, este modelo)

P: 25o (alta quebra)

  1. C = Trip curve

B: 3~5In (carga resistiva, iluminação)

C: 5~ 10 pol. (tomadas, fãs, válvulas solenóides, propósito geral)

D: 10~20In (motores, altas cargas de irrupção)

K: Motor dedicated; Z: Proteção de semicondutores

  1. 16 = Rated current: 6/10/16/20/25/32/40/50/63/80/100UM
  2. Six Main MCB Series

1)S200 Series (Industrial / Cabinet First Choice, This Model Belongs Here)

✅ Breaking capacity: 6o (padrão) / 10o (M variant) / 25o (P variant); Compatível com CA/CC, expandable with auxiliary contacts

Pole types: S201(1P), S202(2P), S203(3P), S204(4P), S201NA(1P+N)

Intervalo atual: 0.5~63A, extended 80/100A versions available

Popular models:

S201M-C16 (1P 16A 10kA, cabinet standard)

S201-C6/C10/C20/C32 (6kA standard)

S202M-C16, S203M-C16, S204-C63

DC variant: S200M-DC; CA/CC universal: S200M-UC

2)SH200 Series (residencial & Property, 6o, Economia)

Mainstream for household distribution boards, 6quebra de kA, B/C curve only

Modelos: SH201(1P), SH202(2P), SH203(3P), SH204(4P), SH201NA(1P+N)

Popular: SH201-C16, SH202-C40, SH203-C63

Derivatives: SH200-OV overvoltage protection, ARVP auto-recovery over/undervoltage

3)SN201 (1P+N Compact Single Module)

SN201L-C16, SN201-C20; space-saving for compact distribution boxes

4)SE200 Series (Mid-range for Projects, 6o)

SE201-C16, SE202-C32, SE203-D63; SE200L=4.5kA entry level

5)SF200 / SF200DC (OEM & DC Especial)

DC circuits for photovoltaic and UPS, SF200DC DC MCB

6)S800 Series (Ultra High Breaking, 15~30kA)

S802S-C63, for main incoming circuits with high short-circuit current

  1. Common Rated Current Range (Applicable to All Series)

Corrente nominal In(UM):

0.5, 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63, 80, 100

  1. Residual Current Circuit Breakers (RCBO, Compatible Platform)

DS200, GSH200, GSN201: Integrated RCBO based on S200 platform, DS201-C16/0.03 (1P 16A 30mA residual current)

  1. Guia de seleção rápida
  2. Gabinete de controle / automation equipment → S200M (10o), C-curve → S201M-C16
  3. Household lighting & socket → SH200 (6o), Curva C
  4. Direct motor start, anti-nuisance trip → D-curve S201M-D16
  5. DC circuit → S200M-DC
  6. S200 Series Overview (S201M-C16 belongs to S200M industrial variant)

1)Breaking Capacity Class

S200 (sem sufixo): 6kA general distribution; Product ID prefix: 2CDS25xxxx

S200M (Sufixo M): 10kA industrial cabinet mainstream (este modelo); Product ID prefix: 2CDS27xxxx

S200P (P suffix): 25kA high breaking for incoming main switch; Product ID prefix: 2CDS28xxxx

2)Pole Code

1=1P; 2=2P; 3=3P; 4=4P; 1NA=1P+N; 3NA=3P+N

3)Trip Curve

B: 3~5In (iluminação, carga resistiva)

C: 5~ 10 pol. (propósito geral, válvulas solenóides, fãs, tomadas)

D: 10~20In (motores, altas cargas de irrupção)

K: Motor dedicated; Z: Proteção de semicondutores

4)Current Range

0.5, 1, 2, 3, 4, 6, 10, 13, 16, 20, 25, 32, 40, 50, 63UM (max 63A)

Papel 1: S200M (10kA Industrial, Including S201M-C16)【Chave】

(1) 1P S201M (Mais amplamente utilizado)

(2) 2P S202M

ModeloNúmero do pedido.ID do produto
S202M-C16101118372CDS272001R0160
S202M-C32101118452CDS272001R0323
S202M-C63101118512CDS272001R0632

(3) 3P S203M / 4P S204M

S203M-C16: Order No.10111865; EU IA:2CDS273001R0167

S204M-C63: Order No.10113531; EU IA:2CDS274001R0639

(4) 1P+N S201M-NA、3P+N S203M-NA

S201M-C16NA;S203M-C20NA(3P+N)

Papel 2: S200 (6kA Standard Version, No M Suffix)

Product ID prefix: 2CDS25xxxx

1P S201 (Main C-curve)

ModeloNúmero do pedido.ID do produto
S201-C16101117092CDS251001R0164
S201-C10101117072CDS251001R0104
S201-C32101117152CDS251001R0325

2P S202 / 3P S203 / 4P S204

S202-C16: 10113641;2CDS252001R0160

S203-C16: 10113665;2CDS253001R0167

S204-C63: 10113695;2CDS254001R0639

Papel 3: S200P (25kA High Breaking, Incoming Main Switch)

Prefixo: 2CDS28xxxx; Modelos: S201P-C16, S202P-C32, S203P-C63

Papel 4: Special Derivatives (S200 Family)

  1. S200M-DC: DC dedicated MCB (VP, UPS)
  2. S200M-UC: CA/CC universal
  3. S200M-TUC: Railway traction dedicated
  4. S200K: K-curve for motor protection; S200Z: Z-curve for semiconductor protection

Papel 5: Acessórios compatíveis (For All S200)

Auxiliary contact S2C-H6R: Ordering code 2CDS200912R0001

Alarm contact S2C-S/H6R: 2CDS200922R0001

Residual current block: DS201 (integrated RCBO, S200 base + RCD block)

Anterior:

Deixe uma resposta

Deixe um recado