NV = Earth Leakage Circuit Breaker (ELCB); 250 = 250AF frame size; SV = Standard breaking capacity (S-class); 3P = 3-pole; In=250A; AC-type electronic residual current circuit breaker ✅ Core Technical Parameters Frame size: 250DE, rated current 250A Poles: 3P (3-pólo, 3-fase 3 fios) Tensão operacional nominal Ue: AC100~440V (compatible with AC380/400/415V) Insulation voltage Ui: 440V; ...

  • Detalhes do produto

NV = Earth Leakage Circuit Breaker (ELCB); 250 = 250AF frame size; SV = Standard breaking capacity (S-class); 3P = 3-pole; In=250A; AC-type electronic residual current circuit breaker

✅ Core Technical Parameters

Tamanho do quadro: 250DE, rated current 250A

Poloneses: 3P (3-pólo, 3-fase 3 fios)

Tensão operacional nominal Ue: AC100~440V (compatible with AC380/400/415V)

Insulation voltage Ui: 440V; impulse withstand voltage Uimp: 6kV

Capacidade de ruptura (AC400V): Icu=Ics=36kA

Earth leakage sensitivity: 3 adjustable levels: 100/200/500mA (select Instantaneous / Time-delayed type when ordering)

Unidade de viagem: Viagem termomagnética (sobrecarga + proteção contra curto-circuito) + electronic residual current protection

Padrões: IEC60947-2, GB/T14048.2, Certificado CE

Dimensões: W105mm × H165mm × D92mm; standard front wiring

Freqüência: 50/60Hz

📌 Análise do código do modelo

NV: Earth Leakage Circuit Breaker (ELCB); NF = non-leakage standard MCCB

250: 250Um tamanho de quadro

SV: S-class Standard breaking capacity; other variants: CV (economic low breaking), Alta tensão (alta capacidade de ruptura, 50o)

3P: 3-pólo; 4P version available

Sufixo: J = Instantaneous trip; D = Time-delayed trip (for selective protection against upstream tripping)

🧩 Optional Accessories (Interchangeable within the series)

Interruptor auxiliar (MACHADO), Alarm switch (AL), Viagem de manobra (MERDA), Undervoltage trip (UVT), Alça rotativa estendida, Rear terminal blocks, Terminal safety covers

📋 Seleção de modelo & Opções de substituição

  1. Upgraded model within the same series: NV250-SEV (new WS-V generation, electronic adjustable overload trip, Certificado CCC, mainstream stock model for domestic projects)
  2. High breaking capacity same-frame variant: NV250-HV (Icu=50kA @ AC400V)
  3. Observação: NV250-SV is an older imported model; NV250-SEV is the domestic mainstream stock model. Direct replacement requires verification of leakage current range, mounting dimensions and accessory interfaces.
  4. Referência alternativa nacional: Chint NM1LE-250S, Delixi CDM1LE-250 (similar breaking capacity and leakage logic, but cabinet cutout and accessories are not interchangeable)

⚠️ Application & Dicas para solução de problemas

Cenários de aplicação: Main incoming feeders in 3-phase power cabinets, fãs, water pumps and production lines, with integrated overload, short-circuit and earth fault protection.

3P version only detects 3-phase leakage; single-phase 220V loads with neutral wire are not allowed. Select 4P if single-phase loads exist.

Common fault: Disparo imediato após fechamento. First distinguish between earth leakage trip (leakage indicator pops out) and overload/short-circuit trip. Adjust leakage setting to 500mA to avoid tripping caused by normal equipment residual current.

Maintenance test: Press the built-in leakage test button regularly to verify the residual current function.

📎 Complete Ordering Example

NV250-SV 3P 250A 100/200/500mA J (Tipo instantâneo)

Tabela de comparação: NV250-SV / NV250-SEV / NV250-HV (250Quadro AF, 3P 250A, AC-type ELCB)

All belong to WS-V series; dimensões de montagem, cabinet cutouts and accessory interfaces are fully interchangeable for direct in-situ replacement.

Core differences: unidade de disparo, breaking capacity and market positioning.

ItemNV250‑SVNV250‑SEVNV250‑HV
PosicionamentoOlder standard breaking model, viagem termomagnéticaNew domestic mainstream model, standard breaking, electronic adjustable overload tripHigh breaking model, viagem termomagnética
Icu/Ics @ AC400V36o / 36o36o / 36o50o / 50o

Full Model List of Mitsubishi WS-V Series MCCB

  1. NF (Standard MCCB without earth leakage) & NV (ELCB with earth leakage) — Small & Molduras Médias (32~250AF)

(1) 32Quadro AF

NF (MCCB): NF32-SV (only S-class available)

NV (ELCB): NV32-SV

(2) 63Quadro AF

NF: NF63-CV (econômico), NF63-SV (padrão), NF63-HV (alta quebra)

NV: NV63-CV, NV63-SV, NV63-HV

(3) 125Quadro AF (Mais amplamente utilizado)

  1. Thermal-magnetic fixed trip: NF125-CV, NF125-SV, NF125-HV
  2. Electronic adjustable trip: NF125-SEV, NF125-HEV
  3. Current-limiting type: NF125-UV, NF125-RV

NV Earth Leakage Breakers: NV125-CV, NV125-SV, NV125-HV, NV125-SEV, NV125-HEV

(4) 250Quadro AF (Your current model frame)

NF Standard MCCB (No leakage protection)

Termomagnético: NF250-CV, NF250-SV, NF250-HV

Electronic adjustable: NF250-SEV, NF250-HEV

Limitação de corrente: NF250-RV, NF250-UV

NV Earth Leakage Circuit Breakers (ELCB, including NV250-SV)

NV250-CV (economic version)

NV250-SV (standard general model, your selected type)

NV250-HV (alta capacidade de ruptura, 50o)

NV250-SEV (electronic adjustable overload)

NV250-HEV (viagem eletrônica + alta capacidade de ruptura)

Leakage current settings: 100/200/500mA 3-level adjustable; J=Instantaneous, D=Time-delayed.

  1. Large Current Frames (400~4000AF, Traditional WS Series)
  2. 400DE: NF400-CW / SW / HW; NV400-CW / SW / HW
  3. 630DE: NF630-CW / SW / HW; NV630-CW / SW / HW
  4. 800~4000AF: NF800~NF4000, NV800~NV4000 (only thermal-magnetic trip; suffix = CW/SW/HW, no SV suffix)

III. Universal Accessory Cross Reference (32/63/125/250DE)

Tamanho do quadroAuxiliary Switch AXAlarm Switch ALShunt Trip SHTUndervoltage Trip UVTLocking Cover
32DEMACHADO-05SVAL-05SVMERDA-05SVUVT-05SVLC-05SV
63DEMACHADO-05SVAL-05SVMERDA-05SVUVT-05SVLC-05SV
125DEAX-1SVAL-1SVSHT-1SVUVT-1SVLC-1SV
250DEMACHADO-05SVAL-05SVMERDA-05SVUVT-05SVLC-2SV

Conclusão: All accessories for NV250-SV are fully compatible with NF250-CV/SV/HV/SEV/HEV and can be retrofitted on site without factory modification.

  1. UL Export Models (Sufixo U)

NF125-SVU / HVU; NF250-CVU / SVU / HVU

NV125-SVU / HVU; NV250-CVU / SVU / HVU

  1. Full Ordering Format
  2. Tipo padrão: NV250-SV 3P 250A J 100/200/500mA (Viagem instantânea)
  3. Selective protection type: NV250-SV 3P 250A D (Time-delayed leakage trip)
  4. Full set with accessories: NV250-SV 3P 250A + AX+AL+SHT(AC220V)+UVT(AC380V)
  5. Old-to-New Model Replacement (WS → WS-V Series)

Old model NF250-SGW → New model NF250-SV

Old model NV250-SW → New model NV250-SV

Dimensões, cutouts and accessories are 1:1 interchangeable with no cabinet modification required