Contator CA CHINT NXC-65A - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Contator CA CHINT NXC-65A - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

contator/

Contator CA CHINT NXC-65A

  Model Segment Description NXC Product series code: Contator CA série CHINT KunLun, upgraded replacement for traditional CJX2 series 65 Corrente operacional nominal: 65UM (under AC-3, 400V) A Configuration code: Tipo padrão (no suffix = standard; suffix /N = reversing type) Common Suffix Coil voltage code: 220V / 380V / 110V / 24V, por exemplo. NXC-65 ...

  • Detalhes do produto

 

Segmento de modeloDescrição
NXCProduct series code: Contator CA série CHINT KunLun, upgraded replacement for traditional CJX2 series
65Corrente operacional nominal: 65UM (under AC-3, 400V)
UMConfiguration code: Tipo padrão (no suffix = standard; suffix /N = reversing type)
Common SuffixCoil voltage code: 220V / 380V / 110V / 24V, por exemplo. NXC-65 220V

Full Model Example:

NXC-65 220V 50Hz = CHINT KunLun 65A AC contactor, tensão da bobina 220V, 50Hz, configuração padrão

Typical Order No.: 710010100000281 (NXC-65 220V 50Hz, 1NÃO+1NC)

  1. Main Technical Data
CategoriaEspecificaçõesObservações
Informações Básicas
Marca / SérieCHINT Electric / KunLun NXC SeriesCompact structure, direct replacement for CJX2-65
Tipo de produto3-phase AC ContactorFor frequent motor starting & remote circuit switching
Padrões de ConformidadeGB/T 14048.1 / CEI 60947-1, GB/T 14048.4 / CEI 60947-4-1International certified, seguro e confiável
Electrical Data
Corrente operacional nominal (Ou seja)65UM (AC-3, 400V)Main contact rated current
Tensão operacional nominal (Ué)380V / 400V (50Hz)Standard industrial grid voltage
Tensão nominal de isolamento (interface do usuário)690VMax withstand voltage of insulation system
Tensão nominal suportável ao impulso (Um)8kVOvervoltage protection capability
Tensão da bobina de controleOptional AC 24V / 36V / 110V / 220V / 380VSelected according to control system
Coil Frequency50 / 60HzGlobal grid compatibility
Frequência operacional nominal1200 cycles/h (AC-3)High frequent operation capability
Quebrando Capacidade10× corrente nominalShort-circuit withstand capability
Configuração de contato
Principais Contatos3NÃO (3-poste normalmente aberto)Standard for main power circuit
Contatos Auxiliares1NÃO + 1NCExpandable on request
Auxiliary Contact Rating5UM / 220V eFor control signal circuits
Características Físicas
Dimensões (L×A×P)90mm × 150mm × 105mmCompactar, economia de espaço
PesoAprox.. 0.8kgLightweight for easy installation
MontagemTrilho DIN padrão de 35 mm / montagem com parafusoSnap-on design, fast assembly
Classe de ProteçãoIP20Suitable for cabinet installation
Temperatura operacional-30℃ ~ +60℃Wide temperature range for harsh environments
Temperatura de armazenamento-25℃ ~ +40 ℃Suitable for transportation & warehouse storage
Electromagnetic Performance
Coil PowerAprox.. 180VA (pick-up) / 25VA (contenção)Baixo consumo de energia, economia de energia
Drop-out Voltage30% ~ 70% de tensão nominalReliable disconnection
Sistema EletromagnéticoOptimized silicon steel lamination (32-piece core)Smooth closure, baixo ruído & loss
Recursos de segurança
CertificaçõesCE, CCCDoméstico & international compliance
Arc ExtinctionMulti-channel magnetic blow-out arc suppressionHigh breaking performance
Funções de proteçãoSobrecorrente, superaquecimento, undervoltage protectionComprehensive equipment & circuit protection
  1. Accessory List
AcessórioModeloFunçãoPosição de montagem
Auxiliary Contact BlockAX-3M/20 (2NÃO), AX-3M/02 (2NC), AX-3M/11 (1NÃO+1NC)Expand auxiliary contacts for complex logicTop front
Time Delay ModuleF5-08 (0.1~30s), F5-11 (0.1~180s)On-delay / off-delay controlTop
Supressor de surtoSR2-220, SR2-380Suppress coil surge voltageBottom
Intertravamento MecânicoNXC-ILPrevent phase short circuit for reversing contactor (NXC-65/N)Side
Mounting Rail35mm standard DIN railFixed installationInside control cabinet
Terminal Protection CoverStandard equippedAnti-touch protectionMain & auxiliary terminals
Mounting ScrewsM4×12mmScrew fixingBase mounting holes
Operation ManualEletrônico / hard copyInstalação, commissioning & maintenance guide
Coil ConnectorOpcionalFast coil wiring & replacementCoil terminal side
  1. Cross-Brand Equivalent & Substituição
MarcaSérieModeloCorrente nominalDiferençasCompatibilidade de substituição
CHINTCJX2CJX2-651165UMOld generation; NXC is fully upgraded versionDirect full replacement (same mounting size)
SchneiderTeSys DLC1D65M7C65UMImport brand, custo mais alto, funções semelhantesAlto (verify mounting & contatos auxiliares)
Siemens3TR3RT2026-1BB4065UMProjeto modular, hot-swap supportMédio (different dimension & fiação)
ABBDEAF65-30-1165UMWide-voltage coil, global applicationMédio (needs position adjustment)
MitsubishiS-NS-N6565UMCompact Japanese design, moderate priceMédio (different terminal layout)
ChangshuCK3CK3-6565UMDomestic equivalent, same performanceAlto (fully compatible size & mounting)
  1. Principais Funções & Aplicativos

Funções principais

  1. High-efficiency Electromagnetic System: Optimized core structure for stable closure, low noise and low energy consumption.
  2. Highly Reliable Arc Suppression: Magnetic blow-out technology with 10× rated breaking capacity for higher safety.
  3. Flexible Expansion: Suporta contatos auxiliares, timer modules and surge suppressors for customized control.
  4. Fácil instalação: Snap-on DIN rail mounting for fast assembly and maintenance.
  5. Wide Temperature Adaptation: Stable operation from -30℃ to +60℃ for various industrial environments.

Aplicações Típicas

  1. Controle Motor: Frequent start/stop/reverse of 3-phase asynchronous motors (aprox.. 30kW @ 400V).
  2. Automação Industrial: Production lines, transportadores, fãs, water pumps and general machinery.
  3. Building Electrical: Sistemas HVAC, fire water pumps, elevator auxiliary circuits.
  4. Machine Tools: Spindle control for milling machines, drilling machines and small machining centers.
  5. Distribuição de energia: Combined with thermal overload relays (NR2 series) for complete motor protection starters.
  6. Supplementary Notes
  7. Product Upgrade: The NXC KunLun series fully replaces the traditional CJX2 series with improved mechanical structure, electromagnetic performance and expandability.
  8. Diretrizes de seleção:

Select current rating according to motor power (65A matches approx. 30motor kW).

Confirm coil voltage (220V / 380V most common).

Expand auxiliary contacts via AX series modules if signal points are insufficient.

  1. Dicas de manutenção:

Regularly check contact wear; replace contacts when excessive contact resistance occurs.

Keep the contactor clean from dust and moisture.

Apply periodic energization (1–2 times monthly) for long-term idle equipment to prevent coil dampness.

CHINT Contactor Full Series List

  1. Product Series Overview
SériePosicionamentoFaixa AtualCaracterísticasReplacement Relation
NXCKunLun Main Series6A ~ 630ACompactar, modular, alto custo-desempenhoFull replacement for CJX2
NC5High-performance Intelligent Series9A ~ 630ASmart control, economia de energia, alta estabilidadeHigh-end alternative to NXC
CJX2Classic Traditional Series9A ~ 95AMature model, econômicoGradually phased out by NXC
NXCFSlim Compact Series9A ~ 32AUltra-thin, economia de espaçoSmall cabinet & instalação compacta
NC8Heavy-duty Industrial Series9A ~ 500AHigh mechanical life, strong arc resistanceFrequent start-stop working conditions
NXCCCapacitor Switching Contactor16A ~ 100AInrush current suppression, reactive power compensation dedicatedCapacitor bank control
NCH8Household & Building Series16A ~ 63ATamanho miniatura, building automationIluminação, AVAC & residential control
CJ40 / CJ20High-power Heavy Series100A ~ 630AHeavy-load design for large motorsHeavy industrial equipment
  1. NXC KunLun Series Main Model List (AC-3 400V)
Corrente nominalStandard ModelReversing ModelStandard Aux. ContatoMatched Motor PowerNúmero do pedido.
6UMNXC-06M1NÃO+1NC0.75kW710010100000276
9UMNXC-09NXC-09/N1NÃO+1NC1.5kW710010100000277
12UMNXC-12NXC-12/N1NÃO+1NC2.2kW710010100000278
18UMNXC-18NXC-18/N1NÃO+1NC3kW710010100000279
25UMNXC-25NXC-25/N1NÃO+1NC5.5kW710010100000280
32UMNXC-32NXC-32/N1NÃO+1NC7.5kW710010100000281
40UMNXC-40NXC-40/N1NÃO+1NC11kW710010100000282
50UMNXC-50NXC-50/N1NÃO+1NC15kW710010100000283
65UMNXC-65NXC-65/N1NÃO+1NC30kW710010100000284
80UMNXC-80NXC-80/N1NÃO+1NC37kW710010100000285
95UMNXC-95NXC-95/N1NÃO+1NC45kW710010100000286
100UMNXC-100NXC-100/N2NÃO+2NC55kW710010100000287
120UMNXC-120NXC-120/N2NÃO+2NC75kW710010100000288
160UMNXC-160NXC-160/N2NÃO+2NC90kW710010100000289
200UMNXC-200NXC-200/N2NÃO+2NC110kW710010100000290
250UMNXC-250NXC-250/N2NÃO+2NC132kW710010100000291
315UMNXC-315NXC-315/N2NÃO+2NC160kW710010100000292
400UMNXC-400NXC-400/N2NÃO+2NC200kW710010100000293
500UMNXC-500NXC-500/N2NÃO+2NC250kW710010100000294
630UMNXC-630ANXC-630A/N2NÃO+2NC315kW710010100000295
  1. NC5 High-performance Series

Model Rule

NC5-[Atual][Tipo][Tensão da bobina]

– Tipo: Padrão / E=Economy / NE=Intelligent / F=Reversing

Faixa AtualPadrãoInteligenteReversingPara. ContatoTensão de Isolamento
9A~38ANC5-09~38NC5NE-09~38NC5F-09~381NÃO+1NC690V
40A~100ANC5-40~100NC5NE-40~100NC5F-40~1001NÃO+1NC690V
115A~250ANC5-115~250NC5NE-115~250NC5F-115~2502NÃO+2NC1000V
315A~630ANC5-315~630NC5NE-315~630NC5F-315~6302NÃO+2NC1000V
  1. Classic CJX2 Series
AtualModeloPara. ContatoMatched Motor
9UMCJX2-0910 / 0901 / 09111NÃO / 1NC / 1NÃO+1NC1.5kW
12UMCJX2-1210 / 1201 / 12111NÃO / 1NC / 1NÃO+1NC2.2kW
18UMCJX2-1810 / 1801 / 18111NÃO / 1NC / 1NÃO+1NC3kW
25UMCJX2-2510 / 2501 / 25111NÃO / 1NC / 1NÃO+1NC5.5kW
32UMCJX2-3210 / 3201 / 32111NÃO / 1NC / 1NÃO+1NC7.5kW
40UMCJX2-4010 / 4001 / 40111NÃO / 1NC / 1NÃO+1NC11kW
50UMCJX2-5010 / 5001 / 50111NÃO / 1NC / 1NÃO+1NC15kW
65UMCJX2-6510 / 6501 / 65111NÃO / 1NC / 1NÃO+1NC30kW
80UMCJX2-8010 / 8001 / 80111NÃO / 1NC / 1NÃO+1NC37kW
95UMCJX2-9510 / 9501 / 95111NÃO / 1NC / 1NÃO+1NC45kW
  1. Other Special Series

NXCF Slim Series

AtualModeloLarguraPara. Contato
9UMNXCF-0922.5milímetros1NÃO+1NC
12UMNXCF-1222.5milímetros1NÃO+1NC
16UMNXCF-1622.5milímetros1NÃO+1NC
25UMNXCF-2536milímetros1NÃO+1NC
32UMNXCF-3236milímetros1NÃO+1NC

NC8 Heavy-duty Series

AtualModeloPolonesesVida Mecânica
9A~38ANC8-09~383P10 milhões de ciclos
40A~100ANC8-40~1003P10 milhões de ciclos
115A~500ANC8-115~5003P/4P8 milhões de ciclos

NXCC Capacitor Contactor

AtualModeloSuppression TypeCapacitor Rating
16UMNXCC-16Series resistor10kvar
25UMNXCC-25Series resistor15kvar
32UMNXCC-32Series resistor20kvar
40UMNXCC-40Series resistor25kvar
50UMNXCC-50Series resistor30kvar
63UMNXCC-63Series resistor40kvar
80UMNXCC-80Series resistor50kvar
100UMNXCC-100Series resistor60kvar

NCH8 Building / Household Contactor

ModeloPolonesesAtualAplicativo
NCH8-16M2P16UMSmart home control
NCH8-25M2P25UMAir conditioning control
NCH8-32M2P32UMSmall water pump
NCH8-40M2P40UMFloor heating system
NCH8-63M2P63UMBuilding lighting
  1. Universal Accessories
AcessórioModeloApplicable Series
Auxiliary Contact BlockAX-3M SeriesNXC / NC5 / CJX2
Time Delay ModuleF5 SeriesFull series
Coil Surge SuppressorSR2 SeriesFull series
Intertravamento MecânicoNXC-IL / NC5-ILReversing contactor
Relé de sobrecarga térmicaNR2 / NR5 SeriesMotor protection combination
35Trilho DIN mmTipo padrãoFull cabinet-mounted contactors
  1. Seleção & Replacement Guide
  2. Series Selection

Novo projeto: Adopt NXC KunLun series as priority.

Intelligent control: Choose NC5NE intelligent contactor.

Compact cabinet: Use ultra-thin NXCF.

Reactive power compensation: Special NXCC capacitor contactor.

  1. Current Selection

Rated current ≥ motor rated current × 1.1 (dever normal).

Frequent operation ≥ motor current × 1.25.

  1. Tensão da bobina

Match control circuit voltage: AC220V / AC380V most common; safety low-voltage 24V/36V optional.

  1. Contatos Auxiliares

Expandable via external auxiliary blocks when signal points are insufficient.

Reversing circuit must adopt mechanical interlock type.