The Chint NXC-75/220V AC contator is a commonly used industrial-grade control device suitable for controlling three-phase loads with a rated current of 75A and a coil voltage of 220V. Below is a detailed analysis of this contactor model:
- Basic Parameters and SpecificationsSchneider LC1DN3210 and Chint NXC32 contactors
- Rated ParametersContator DC Chint NC1-5011-36V
Significado do modelo: NXC-75 (design series)/220V (coil voltage)
Corrente nominal: 75UM (can control 37kW three-phase motors under AC-3 usage category)
Coil Voltage: 220V e (50/60Hz)
Pole Configuration: 3 postes (main contacts) + 2 normalmente aberto (NÃO) + 2 normalmente fechado (NC) contatos auxiliares
Vida Mecânica: 10 milhões de operações
Vida Elétrica: 1 milhões de operações (AC-3 category)
- Cenários de aplicaçãoFiação do contator AC Delixi
– Start, stop, and forward/reverse control of three-phase motors
– On/off control of electric heating equipment and lighting circuits
– Combined with thermal relays to form motor protection circuits
- Core Structure and Terminal DescriptionCHINT AC contactor CJX2
- Appearance and Components

(Schematic diagram; actual product may vary)
- Terminal Layout
| Tipo de terminal | Identification/Number | Function Description |
| Main Contacts | L1/T1, L2/T2, L3/T3 | Three-phase power input/output (L1-L3 for power supply, T1-T3 for load) |
| Coil Terminals | A1, A2 | 220V coil power supply (A1 to live wire, A2 to neutral wire) |
| Auxiliary Contacts | 13/14 (NÃO), 21/22 (NC) | Control circuit signal feedback (NÃO/NC) |
| Thermal Relay Interface | 95/96, 97/98 | Connect to thermal relay for overload protection |
III. Typical Application Wiring Diagrams
Cenário 1: Direct Start Control of Three-Phase Motor
Explicação:
– Disjuntor (P): Protects the circuit from overloads and short circuits
– Contator (KM): Main contacts control motor power supply; coil A1/A2 connected to 220V
– Start Button (SB1): When pressed, the coil is energized, main contacts close, and the motor starts
Cenário 2: Motor Control with Overload Protection
Explicação:
– Thermal Relay (FR): Connected to the main circuit via terminals 95/96; NC contacts 97/98 are wired in series in the control circuit
– During overload, the bimetallic strip in FR heats and bends, opening the NC contacts, de-energizing the contactor coil, and stopping the motor
- Precauções de instalação e uso
- Requisitos Ambientais
– Temperature Range: -5°C ~ +40°C
– Umidade: ≤95%RH (sem condensação)
– Altitude: ≤2000 meters
- Etapas de instalação
– Install vertically to maintain heat dissipation space
– Use M8 bolts for main circuit terminals, tightening torque 8-10N·m
– Use 0.75-2.5mm² wires for control circuits to ensure good contact
- Pontos-chave de manutenção
– Regularly clean oxide layers on contact surfaces
– Check for loose bolts (at least once a year)
– Coil temperature rise should not exceed 65K (at 40°C ambient temperature)
- Falhas e soluções comuns
| Fenômeno de falha | Possíveis causas | Soluções |
| Coil not energizing | Energia não conectada, coil burned out, mechanical jamming | Check voltage, replace coil, clean components |
| Contact overheating | Poor contact, excessive load, contact oxidation | Tighten terminals, reduce load, polish contacts |
| Not releasing after power-off | Residual magnetism in core, contact adhesion | Replace core, clean or replace contacts |
| Excessive noise | Broken core short-circuit ring, voltage fluctuations | Replace core, stabilize power supply voltage |
- Selection Alternatives
If NXC-75 is out of stock, consider the following alternative models:
Schneider LC1-D75: Same specifications, strong compatibility
Siemens 3TF52: Higher reliability, suitable for critical applications
ABB A9-40/75: Projeto modular, easy to expand
Observação: When replacing, confirm that coil voltage, contact capacity, e as dimensões de instalação são consistentes.
Resumo
The Chint NXC-75/220V AC contactor is a reliable industrial control component that can effectively manage three-phase loads through proper wiring and maintenance. Before use, verify power supply compatibility and prioritize control circuits with overload protection to extend equipment life and ensure safety.
Contator,disjuntor,inversor solar,medidor elétrico,baterias solares














NH42-63-318x560.png)