Inversor de controle vetorial Delta VFD055C43A-21-5.5kW

MarcaModeloSérie
Siemens6SL3210-1KE21-3UF1 (G120C PN)SINAMICS G120C
MitsubishiFR-A840-00720-2-60FREQROL A840
YaskawaCIMR-AB4A0018FBAA1000
SchneiderATV320U75N4Altivar 320
ABBACS550-01-012A-4ACS550

  • Detalhes do produto

 

Model PartSignificadoDetailed Explanation
VFDDelta Inverter IdentifierAbbreviation for Variable Frequency Drive, the universal prefix for Delta’s industrial automation inverters.
55Potência do motor aplicávelFor 5.5kW (7.5HP) motores; this is the rated output power of the drive.
CCódigo da sérieC2000/C2000+ Series – Delta high-performance general-purpose vector inverter, supporting induction motors and permanent magnet synchronous motors.
43Classe de tensão & Fase4 = 3-phase 400V class (380~480V); 3 = 3-phase input (vs. 1 for single-phase).
UMModo de controle & CaracterísticasSupports Vector Control (FOC), Controle de Torque (TRQ), high-performance algorithm, 200% starting torque at 0.5Hz.
-21Version & ConfiguraçãoStandard version: built-in braking unit (selected power ratings), no built-in EMC filter (external available), compliant with international standards.
  1. Especificações Técnicas Principais (Official 2026 Data)
CategoriaItemValorNotas
Basic SpecsPotência nominal5.5kW (7.5HP)For 5.5kW 3-phase induction motors
Tensão de entrada3-fase 380~480V (+10%/-20%)47~63 Hz, ampla faixa de tensão
Rated Output Current12UM (serviço pesado) / 10.8UM (light duty)Continuous operation in heavy-duty mode
Output Frequency Range0.1~600HzFor both low‑ and high‑speed applications
Desempenho de controleModo de controleSensorless Vector, Closed-loop Vector, Controle V/FSwitchable closed/open loop
Torque inicial200% torque nominal a 0,5 HzIdeal for heavy starting loads
Capacidade de sobrecarga150% for 60s; 200% for 3sFor shock loads
Precisão de velocidade±0,5% (open-loop) / ±0.02% (closed-loop)High precision speed control
Torque Response Time≤10msFast dynamic response
HardwareGrau de ProteçãoIP20 (cabinet mount)Finger‑safe; clean environment recommended
ResfriamentoForced air (removable fan)Fácil manutenção, longa vida útil
Built-in FunctionsBraking unit (≤7.5kW), CLP (5,000 steps)High integration, fewer external parts
ComunicaçãoRS-485 (Modbus RTU) padrãoPROFINET/EtherNet/IP/CANopen optional
AmbienteOperating Temp-10~40°C (derate 40~50°C)Derate 1% per °C above 40°C
Storage Temp-20~60°CAvoid moisture & corrosive gas
Umidade5~95% (non‑condensing)Suitable for industrial environments

III. Core Features & Vantagens

3.1 High‑Performance Control

Vector control: Precise independent torque & speed control for complex loads.

Built-in PLC: 5,000-step logic programming for simple automation, reducing external PLC dependency.

Auto energy saving: Dynamically adjusts output voltage; saves 20~50% at light load.

Motor auto-tuning: Completes matching in <10é, simplifies commissioning.

3.2 High Reliability Design

Modular structure: Hot-swappable keypad, expandable I/O and communication cards for easy maintenance.

Full protection: Sobrecorrente, sobretensão, subtensão, overheat, sobrecarga, perda de fase, falha de terra, etc..

Safe stop: Supports STO (Torque seguro desativado), SIL 2 certified.

Wide grid tolerance: Withstands ±15% voltage fluctuation for harsh grids.

3.3 Flexible Communication & Expansion

Standard RS-485 Modbus RTU for multi-drive network control.

Optional modules: PROFINET, Ethernet/IP, PROFIBUS DP, CANopen.

Compatible with Siemens, Mitsubishi, Rockwell PLCs via standard telegrams and process objects.

Remote monitoring & diagnostics via Delta DIAStudio or TIA Portal.

  1. Aplicativos & Selection Tips

4.1 Recommended Applications

IndústriaAplicações TípicasCaracterísticas
General MachineryPumps, fãs, compressores, misturadoresEnergy saving, stable operation, longer equipment life
Material HandlingConveyors, guindastes, guinchos, packaging machinesHigh precision speed control, heavy start, quick stop
Metal ProcessingLathes, milling, grinding, punching machinesHigh response, precise positioning, controle de torque
Textile & DyeingTextile machines, dyeing machines, stenter framesConstant tension, synchronous operation, wide speed range
Plastic & RubberInjection molding, extrusion, blow moldingSignificant energy saving (20~60%), stable pressure control

4.2 Pontos-chave da seleção

  1. Correspondência de poder: Use VFD055C43A-21 for 5.5kW motors; avoid undersizing.
  2. Load type:

Constant torque (transportadores, misturadores): use heavy-duty mode (12UM).

Variable torque (fãs, bombas): light-duty mode (10.8UM) for better efficiency.

  1. Requisitos de controle:

High-precision positioning: use encoder (PG card) closed-loop vector.

Network control: add communication module (por exemplo, PROFINET).

  1. Ambiente:

Alta temperatura: extra cooling or derating required.

Ambiente empoeirado: dust cover + regular fan cleaning.

  1. Modelos de substituição & Upgrade Path

5.3 Sugestões de atualização

  1. Basic upgrade: VFD‑M/GD10 → C2000+ for better precision & funções.
  2. Communication upgrade: Add PROFINET card for Industry 4.0 connectivity.
  3. System upgrade: Combine with Delta PLC (DVP series) & HMI for full automation solution.

Buying Notes

  1. Confirm suffix -21 (standard version), avoid old versions (por exemplo, -00).
  2. Verify power & atual: 5.5kW → 12A rated.
  3. Buy from authorized Delta channels for genuine product & service.
  4. Order accessories as needed: communication card, keypad, braking resistor.

VII. Instalação & Manutenção

7.1 Installation Rules

  1. Montagem: Wall/cabinet mount, instalação vertical; ≥150mm clearance top & bottom for ventilation.
  2. Fiação:

Separate power & control cables to avoid interference.

Shielded cable for signals, single‑end grounding.

Braking resistor matched to power (≤7.5kW internal; external ≈100Ω/500W).

  1. Aterramento: Ground resistance ≤4Ω for safety & noise immunity.

Delta VFD055C43A-21 is a high‑performance 5.5kW vector inverter from the C2000+ series, featuring high precision, confiabilidade, and expandability for diverse industrial applications. With built-in PLC, wide voltage tolerance, and complete protection, it is an excellent choice for general industrial drive solutions. Select based on motor power, tipo de carga, control requirements, and environment for optimal performance and cost-effectiveness.

Complete Replacement Guide for Delta VFD055C43A-21

  1. Delta Internal Replacements (C2000+ Series, Seamless Compatibility)

1.1 Direct Same‑Series Replacements

Fault CodeCausaSolução
OCSobrecorrenteCheck motor short, sobrecarga, acceleration time
OVSobretensãoCheck mains voltage, deceleration time, braking resistor
UVSubtensãoCheck input phase, tensão, cable size
OHOverheatCheck fan, ventilação, temperatura ambiente
PHPhase lossCheck input/output wiring, motor winding

1.2 Near‑Power Replacements

ModeloPoderCorrente nominalPrincipais recursosAplicativo
VFD055C43A-21 (Original)5.5kW12UM / 10.8UMC2000+, vector, built-in brake, RS-485General industry
VFD055C43A-21 (Upgraded)5.5kW12UMBetter cooling, 10,000-step PLC, more protocolsNovos projetos
VFD055CH43A-215.5kW12UMCH2000, fan/pump specializedFãs, bombas
VFD055CP43B-215.5kW12UMCP2000, hoist/crane dedicatedCranes, guinchos
  1. Global Brand Replacements (5.5kW / 400V Vector)

2.1 Premium Brands

MarcaModeloSérieControlarAdvantage
Siemens6SL3210-1KE21-3UF1 (G120C PN)SINAMICS G120CVector/V/FPROFINET, Filtro EMC
MitsubishiFR-A840-00720-2-60FREQROL A840VectorHigh response, built-in PLC
YaskawaCIMR-AB4A0018FBAA1000VectorLow noise, estável
SchneiderATV320U75N4Altivar 320Vector/V/FCompactar, multi-protocol
ABBACS550-01-012A-4ACS550CDTHigh torque accuracy

2.2 Cost‑Effective Brands

MarcaModeloSérieControlarAdvantage
InovaçãoMD280NT5.5GBMD280VectorPROFINET supported
VeichiAC70-T3-055GAC70VectorFull-featured, baixo custo
INVTCHF100A-5R5G/7R5P-4CHF 100AVectorBuilt-in brake un

III. Critical Replacement Rules (Must Follow)

  1. Poder & atual: Rated power ≥5.5kW, current ≥12A (serviço pesado).
  2. Tensão: 400Classe V (380~480V) only; do NOT use 200V directly.
  3. Controlar: Prefer vector control for matching dynamics.
  4. Sobrecarga: At least 150% for 60s.
  5. Comunicação: RS-485 standard; PROFINET/EtherNet/IP optional.

Compatibilidade Mecânica

Dimensões: ~90×180×150mm – use same or smaller size.

Resfriamento: Forced air – keep airflow direction.

Brake unit: Internal for ≤7.5kW; match external if needed.

Keypad: Use Delta standard keypad or compatible.

Best Replacement by Application

General machinery: VFD055C43A-21 upgraded or Siemens G120C PN.

Fãs & bombas: VFD055CH43A-21 or Schneider ATV320U75N4.

Cranes/hoists: VFD055CP43B-21 or Mitsubishi FR-A840.

Budget projects: Inovance MD280NT5.5GB or Veichi AC70-T3-055G.

  1. Upgrade Paths

4.1 Delta Internal Upgrade

  1. C2000 → C2000+ (performance & function improvement).
  2. Add PROFINET module (VFD-CM-PN01) for industrial networking.
  3. Pair with Delta PLC + HMI for full automation system.

4.2 Cross‑Brand Upgrade

  1. Comunicação: RS-485 → PROFINET / Ethernet/IP.
  2. Controlar: Open-loop vector → closed-loop vector with encoder.
  3. Segurança: Choose models with STO (SIL 2).

The Delta VFD055C43A-21 has a wide range of replacements.

Same‑brand (C2000+ upgraded) offers seamless compatibility.

Cross‑brand (Siemens G120C PN, Mitsubishi FR-A840) provides higher performance.

Always follow core parameter matching to ensure stable, reliable replacement without performance loss or equipment damage.

Anterior: