FC Meaning: Fluke-Conectar, Bluetooth wireless connection, supporting mobile APP data logging, trend graphing and on-site report generation.
Part of the 370-FC series industrial-grade clamp meters. Supplied standard with an 18-inch iFlex flexible current probe (optional for 375-FC).
Especificações principais
| Item | Especificações |
| Jaw AC/DC Current | 0‑1000A (True‑RMS) |
| iFlex Flexible Probe AC Current | 0‑2500A AC |
| Tensão CA/CC | 0‑1000V AC/DC |
| Freqüência | 5‑500Hz (for both meter jaw and iFlex) |
| Resistência | 0‑60kΩ with continuity test |
| Capacitância | 0‑1000μF |
| DC Millivolts | 500mV range |
| Jaw Opening | 34 milímetros |
| Classificação de segurança | CAT‑III 1000V / CAT‑IV 600V |
| Fonte de energia | 4 × AA batteries |
| Garantia | 3‑year |
Principais recursos
- VFD Low-pass Filter: Optimized for VFD output measurements, suppresses carrier-frequency interference for accurate motor-drive readings; not available on 374-FC.
- In-Rush Surge / Starting Current Mode: Filters noise to accurately capture motor inrush current, matching real-world conditions seen by protective devices.
- Fluke-Connect Bluetooth Wireless: Remote readings via mobile device, registro de dados, trend curves, on-site PDF report generation; ShareLive video call for collaborative troubleshooting, keeping users away from arc-flash hazards.
- Mínimo / Máx. / Average recording: Captures intermittent fault fluctuations.
- iFlex Flexible Coil: Enables measurements in confined spaces and on large-diameter cables without cable disconnection.
Lista de embalagem padrão
376-FC clamp meter main unit
i2500-18 iFlex flexible current probe (18-polegada)
Test leads and test probes
TPAK magnetic hanging strap
Soft carrying case
User manual and safety manual
Comparação de séries (374-FC / 375-FC / 376-FC)
| Modelo | Jaw AC/DC Current | iFlex Included | VFD Filter | DC‑mV |
| 374‑FC | 600UM | ❌ Optional | ❌ | ❌ |
| 375‑FC | 600UM | ❌ Optional | ✅ | ✅ |
| 376‑FC | 1000UM | ✅ Standard | ✅ | ✅ |
Dica de seleção: Choose 376-FC for 1000A AC/DC, frequent VFD testing, high-current work and wireless logging. Choose 375-FC for applications within 600A.
Aplicações Típicas
Motores industriais, drives de frequência variável, distribution panels, UPS, Inversores fotovoltaicos
Plant electrical maintenance, comissionamento de equipamentos, diagnóstico de falhas, motor inrush-current testing
On-site remote reading, data archiving and test-report generation
Uso & Notas de manutenção
- The iFlex flexible coil measures AC only, DC measurements must use the meter’s physical jaws.
- Enabling the VFD filter reduces bandwidth; disable it for standard power-frequency measurements.
- In-Rush mode captures transient startup events and shall not be used for steady-state readings.
- Second-hand inspection checklist: Undamaged jaws, intact iFlex coil, functional Bluetooth, sound lead insulation, valid calibration status.
Fluke 375-FC vs 376-FC Key Differences
Both support Fluke-Connect Bluetooth, VFD filter, In-Rush mode, DC-mV and True-RMS, with identical safety ratings. Differences lie in jaw current range, iFlex inclusion and crest factor.
| Item de comparação | Fluke 375‑FC | Fluke 376‑FC |
| Jaw AC/DC Current | 600A AC/DC | 1000UM (999.9UM) CA/CC |
| iFlex Flexible Probe | Opcional, max 2500A AC | Standard i2500‑18 (18‑inch), max 2500A AC |
| Faixa de tensão | 1000V CA/CC | 1000V CA/CC |
| VFD Filter | ✅ Suportado | ✅ Suportado |
| In‑Rush Motor Surge | ✅ Suportado | ✅ Suportado |
| DC‑mV 500mV | ✅ Suportado | ✅ Suportado |
| Bluetooth FC Wireless | ✅ Suportado | ✅ Suportado |
| Crest Factor (FC) | 3 @ 600A | 3 @ 500A; 2.5 @ 1000A, better distorted‑current performance at high current |
| Jaw Opening | 34 milímetros | 34 milímetros |
| Garantia | 3‑year | 3‑year |
Plain-language Explanation
- 375-FC: 600A upper limit
Suitable for most low-voltage distribution panels, motors and loads up to 400A. iFlex coil is sold separately. Cost-effective for routine plant maintenance where 600A is sufficient.
- 376-FC: 1000A jaw + factory-fitted iFlex
Designed for 800-1000A loads, barramentos, high-power UPS and high-power VFDs. Ready-to-measure up to 2500A AC out-of-box with no extra probe purchase.
⚠️ Nota: iFlex flexible coil measures AC only. High DC current must be measured by the meter’s built-in jaws.
Orientação de seleção
Most operating conditions ≤600A, rare high-AC-current work → 375-FC
Frequent 800-1000A measurements, regular large-AC-current testing, no wish to buy iFlex separately → 376-FC
Second-hand Purchase Notes
Many used 375-FC units do not include iFlex. Genuine complete 376-FC units come with the i2500-18 flexible coil.
For both models verify: VFD filter function, In-Rush mode, Bluetooth connectivity, jaw movement and lead insulation integrity.
Diferenças de aplicação: Fluke 375-FC vs 376-FC
Feature sets are nearly identical: VFD filter, In-Rush surge, Fluke-Connect Bluetooth and DC-mV are all present. Application gaps stem from two core points:
① Maximum jaw current: 600A AC/DC for 375-FC; 1000A AC/DC for 376-FC
② iFlex is factory-supplied on 376-FC but must be purchased separately for 375-FC.
🟢 375-FC Application Scope (600A jaw, iFlex optional)
For general-purpose plant maintenance with steady-state load current ≤600A and rare >600A DC measurements.
- Medium-small VFD-driven motors: 30-200 kW motors, MCC cabinets; measure operating current, startup inrush and VFD output (VFD filter enabled).
- General low-voltage distribution panels: Feeder circuits, ≤400A molded-case breaker loops; routine inspection and preventive maintenance with data logging.
- DC-side work: DC power panels, small-capacity UPS and DC busbars, for DC currents no higher than 600A.
- Edifícios comerciais, HVAC and general equipment commissioning: iFlex probe may be purchased later if occasional high-AC-current measurement is needed.
- Maintenance teams: Majority circuits sit below 600A; cost-optimized choice when iFlex is not used daily.
⚠️ 375-FC Limitations
Jaw DC measurement is capped at 600A. DC above this value cannot be measured (iFlex works for AC only).
Flexible coil is not supplied; extra procurement required for large cables or tight-fit busbar measurements.
🔴 376-FC Application Scope (1000A jaw, iFlex standard)
Targets high-current scenarios, frequent 600-1000A AC/DC measurements and regular flexible-probe usage for large cables / barramentos.
- Heavy-duty industrial motors: 200-450 kW motors with operating current at or above 600A; motor inrush testing and high-power VFD circuit diagnostics.
- High-power UPS, low-voltage busbars and incoming cabinets: Transformer secondary and 800-1000A incoming-feed circuits; direct high-DC-current readings via main jaws.
- PV and energy-storage PCS converters: Mixed AC-DC environments; capable of near-1000A DC readings which cannot be achieved by the 375-FC.
- Frequent iFlex-probe deployments: Congested cable trays, busbars and oversized cables that cannot fit within standard jaws; 2500A-AC measurement capability available immediately out-of-box.
- Integração de sistema, project commissioning & EPC sites: Mixed-spec loads covering low-ampere loops through kilo-ampere incoming feeds; one-meter coverage; remote readings for test-reporting and arc-flash hazard mitigation.
⚠️ 376-FC Caveat
iFlex remains AC-only; 1000A DC is measured exclusively through the physical meter jaws.
Referência de seleção rápida
| Condição de trabalho | Modelo preferido |
| Most circuits ≤600A, seldom encounter high‑current loads, infrequent iFlex use | 375‑FC |
| Regular >600A AC/DC loads (incoming cabinets, high‑power PCS, motores grandes) | 376‑FC |
| Frequent large‑cable / busbar work, want iFlex included as standard | 376‑FC |
| DC current routinely exceeds 600A (energy‑storage, heavy‑duty DC busbars) | 376‑FC only (iFlex cannot measure DC) |
| Budget‑constrained, iFlex can be procured later on demand | 375‑FC |
Common Field Pitfall Reminder
The iFlex flexible probe measures AC only.
👉 High DC current must always use the meter’s hard jaws regardless of model; flexible coils offer no DC capability.
Therefore for energy-storage / PCS DC-side currents above 600A, the 375-FC will overflow; 376-FC is mandatory.
Contator,disjuntor,inversor solar,medidor elétrico,sensor,Codificador,CLP



















NH42-63-318x560.png)



