Kraus & Naimer Switch CG4-A251-600-FS2 - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Kraus & Naimer Switch CG4-A251-600-FS2 - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

Kraus & Naimer Switch CG4-A251-600-FS2

CG4-A251-600-FS2 | Kraus & Naimer Blue Line Cam Switch 2-pole 4-position non-zero selector switch, rated 10A/440V AC/DC, central locking mounting, ideal for industrial control circuit switching Model Code Definition Code Segment Description CG4 Product Series: CG compact cam switch, Size S00 A251 Contact Configuration: 2-pole 4-position without zero position, 60° switching step, rigid silver contact ...

  • Detalhes do produto

CG4-A251-600-FS2 | Kraus & Naimer Blue Line Cam Switch

2-pole 4-position non-zero selector switch, rated 10A/440V AC/DC, central locking mounting, ideal for industrial control circuit switching

  1. Definição de código de modelo
Segmento de códigoDescrição
CG4Série de produtos: CG compact cam switch, Size S00
A251Configuração de contato: 2-pole 4-position without zero position, 60° switching step, rigid silver contact bridge
600Operating Angle: 3×60° (total 180°), 4 positions (1-4)
FS2Tipo de montagem: Central locking, panel cutout 16/22mm, front protection grade IP66/IP67/IP69k
  1. Main Technical Specifications
ItemEspecificação
MarcaKraus & Naimer (Austria Blue Line)
TipoOff-load tap switch / Uniselector
Pólo & Posição2 postes, 4 positions (no zero position)
Rated Insulation Voltage Ui440V CA/CC (CEI), 300V e (UL)
Rated Continuous Current Iu/Ith10UM (ambient 55°C, peak 60°C)
Rated Operational Current IeAC-15: 2.5UM (220-240V), 1.5UM (380-440V)
Potência nominalAC-3: 0.75kW (380-440V, 2P), 2.2kW (380-440V, 3P)
Switching Angle60° per step, total 180°
Método de montagemCentral locking (FS2), panel hole 16/22mm
Tipo de terminalTerminal de parafuso, tightening torque 0.4Nm (3.5lb-in)
Cable SizeSolid wire: 0.5-1.5mm²; Stranded wire: 0.75-1.5mm² (max 2.5mm² with cable lug)
Grau de ProteçãoFrente: IP66/IP67/IP69k, Traseira: IP20
CertificaçõesCEI 60947-3, EM 60947-3, VDE 0660 Papel 107, UL 60947-4-1, UL 508
CorGrey / Preto
Número do pedido.703584 (Conrad), 9004257056231 (EAN/GTIN)
  1. Full CG4 A2xx-600-FS2 Series List
ModeloPolonesesPositionsZero PositionPrincipais recursos
CG4-A201-600-FS222SimTipo básico, 2-position with zero
CG4-A220-600-FS213Não1-pole 3-position non-zero
CG4-A221-600-FS223Não2-pole 3-position non-zero
CG4-A231-600-FS214Não1-pole 4-position non-zero
CG4-A251-600-FS224Não2-pole 4-position non-zero (current model)
CG4-A250-600-FS224NãoSimilar to A251, slight contact difference
CG4-A213-600-FS223Sim2-pole 3-position with zero, G251 handle
  1. Equivalente & Modelos de substituição
Tipo de substituiçãoModeloMarcaObservações
Same Series ReplacementCG4-A250-600-FS2Kraus & NaimerDifferent contact bridge design, fully function compatible
Same Brand UpgradeCG4-A251-600-FT2Kraus & NaimerFlange locking mounting, mesmo desempenho
Competitor Alternative2002/2P4WABB2P4-position selector switch, compatible mounting dimension
Competitor Alternative3LD2102Siemens2-pole selector switch, 10Uma corrente nominal, IP65
  1. Escopo de aplicação & Industry Usage

Aplicativos recomendados

  1. Automação Industrial: PLC control circuit switching, equipment mode selection (Manual/Auto/Remote)
  2. Sistema de energia: Tensão & current measuring circuit switching, standby power selection
  3. Equipamento Mecânico: Machine tool speed shift control, conveyor direction control
  4. Elétrica predial: Lighting zone control, air conditioner mode selection
  5. Marinho & No mar: Control circuit switching under harsh environment (IP69K protection)

Non-recommended Scenarios

  1. On-load switching: Not applicable for direct inductive load switching (por exemplo. motores), use with contactors
  2. High frequent operation: Electrical service life approx. 50,000 ciclos, not for high-speed frequent switching
  3. High voltage system: Max rated insulation voltage 440V, not for 690V and above systems
  4. Solução de problemas & Soluções
Fenômeno de falhaPossíveis causasSoluções
Switch cannot rotate1. Lock mechanism not released1. Unlock FS2 locking device completely
2. Internal mechanical jam2. Power off then inspect internal springs & contatos
3. Over-tight wiring3. Rewire and control torque ≤0.4Nm
Poor contact performance1. Oxidação de contato1. Polish silver contacts gently with fine sandpaper
2. Contact wear2. Replace contact module or whole switch
3. Fiação solta3. Retighten all terminals
Failed protection performance1. Aging sealing gasket1. Replace original sealing gasket
2. Improper installation2. Ensure close fitting between switch and panel
3. Oversized panel cutout3. Adjust panel hole within 16-22mm
Decreased rated current1. Excess ambient temperature1. Lower ambient temperature or enhance heat dissipation
2. Contaminated contacts2. Clean contacts and terminals
3. Undersized cables3. Use qualified cables (stranded ≥0.75mm²)
  1. Daily Maintenance Guidelines
  2. Periodic Inspection: Check locking structure and contact condition every 6 meses
  3. Limpeza: Remove dust by compressed air, avoid chemical detergent
  4. Torque Management: Strictly follow 0.4Nm tightening torque during wiring
  5. Ambient Control: Avoid long-term operation above 55°C
  6. Prevenção de operação incorreta: Keep locking mechanism functional to avoid accidental switching
  7. Air Freight Compliance & Certificação

Air Shipment Allowed: No built-in lithium battery / super capacitor, classified as general electrical component

Main Certificates: CE (compatível com IEC 60947-3), UL 508, VDE 0660

HS Code: 85365080 (Electrical control switches & disjuntores)

Complete Model List of Kraus & Naimer Blue Line Cam Switches

  1. Visão geral da classificação geral

Kraus & Naimer Blue Line switches are divided into 4 categories by rated current and usage, covering full range 10A~2400A.

  1. Control Switch Series (10A~25A) | Catalog 120

2.1 CG Series Compact Control Switch (10A/20A, IP20)

Modelo BásicoCorrente nominalTamanhoCaracterísticasModelos Típicos
CG4/CG4-110UMS001μ/35μ gold-plated contact, double-break silver alloy bridgeCG4-A201-600-FS2, CG4-A251-600-FS2
CG610UMS0Standard control switch, finger-safe terminalsCG6-A201-600-FT2
CG710UMS0Função especial, illuminated handle optionalCG7-A214-600-FT2
CG810UMS0Universal type, multi-mounting availableCG8-A220-600-FT4
CG910UMS0With lock mechanism, anti-misoperationCG9-A213-600-FS2
CG10/CG11/CG1210UMS0Multi-pole, máx. 4 postesCG12-A251-600-FS2
CG1620UMS1Corrente mais alta, heavy-duty controlCG16-A201-600-FT2

2.2 CH/CHR Series (10A~25A, Lockable Terminal)

Modelo BásicoCorrente nominalTamanhoCaracterísticasModelos Típicos
CH10/CHR1010UMS0CHR anti-loose terminal anti-vibrationCH10-A201-600-FT2
CH11/CHR1110UMS0Multi-pole, double-break designCHR11-A251-600-FS2
CH12/CHR1210UMS0Special cam for complex controlCH12-A213-600-FS2
CH16B/CHR16B16UMS1Corrente mais alta, finger protectionCH16B-A221-600E
CH20/CHR2020UMS1Heavy-duty for motor circuitsCH20-A251-600-FS2

2.3 CGD Series Mini Control Switch (5A Low Current)

Modelo BásicoCorrente nominalTamanhoCaracterísticasModelos Típicos
CGD4-15UMS00Ultracompacto, 35渭 gold-plated contactCGD4-1-A201-600-FT2
  1. Controlar & Load Switch Series (10A~315A) | Catalog 100

3.1 CA Series Universal Control Switch (10A~25A)

Modelo BásicoCorrente nominalTamanhoCaracterísticasModelos Típicos
CA010UMS00Mini type for narrow spaceCA0-A201-600-FT2
CA210UMS0Standard double-break structureCA2-A201-600-FT2
CA410UMS0Multi-pole up to 4 postesCA4-A201-600-FT2
CA10/CA10B10UMS0Finger-safe anti-shock terminalCA10-A722-G001
CA20/CA20B20UMS1Heavy-duty controlCA20B-A221-600E
CA25/CA25B25UMS1Max current for motor controlCA25B-A251-600-FS2

3.2 CAD Series Self-cleaning Contact Switch (10A~16A)

Modelo BásicoCorrente nominalTamanhoCaracterísticasModelos Típicos
CAD510UMS0Mini self-clean cross contactCAD5-A201-600-FT2
CAD1110UMS0High contact stabilityCAD11-US5626-FT1
CAD1616UMS1Industrial heavy-duty applicationCAD16-A221-600E

3.3 C Series Load Switch / Isolator (10A~315A)

Modelo BásicoCorrente nominalTamanhoCaracterísticasModelos Típicos
C2626UMS1Basic load switchC26-A201-600-FT2
C3232UMS1Higher breaking capacityC32-A221-600E
C42/C4340UMS22P/3P optionalC43-A221-600E
Capítulo 6363UMS2Heavy load switchC63-A251-600-FS2
C80/C80-680UMS36-pole optionalC80-6-A221-600E
C125/C125-6125UMS3Medium high currentC125-A251-600-FS2
C200-4200UMS44-pole for 3-phase 4-wireC200-4-A221-600E
C315/C316315UMS4Main power isolation switchC316-A251-600-FS2

3.4 CL Series Economic Load Switch (10A~20A)

Modelo BásicoCorrente nominalTamanhoCaracterísticasModelos Típicos
CL1010UMS0Cost-effective basic controlCL10-A201-600-FT2
CL2020UMS1Economic heavy-duty controlCL20-A221-600E
  1. High Current Isolator Series (350A~2400A) | Catalog 100

4.1 L Series High Current Isolator

Modelo BásicoCorrente nominalTamanhoCaracterísticasModelos Típicos
L350350UMS5Standard high current isolatorL350-A221-600E
L500500UMS5Medium large currentL500-A251-600-FS2
L630630UMS6Industrial main power supplyL630-A201-600-FT2
L800800UMS6Forte desempenho de quebraL800-A251-600-FS2
L1000/L11001000A/1100AS7Large industrial equipmentL1100-A221-600E
L14501450UMS7Ultra-large currentL1450-A251-600-FS2
L19001900UMS8Factory main power switchL1900-A221-600E
L24002400UMS8Max current for heavy industryL2400-A251-600-FS2
  1. Load Break Switch Series (16A~1250A) | Catalog 100

5.1 KF/KH/KG Series Load Break Switch

Modelo BásicoCorrente nominalTamanhoCaracterísticasModelos Típicos
KF16/KF2016A/20AS0/S1Basic load break switchKF20-T203/SGZ006E
KH32/KH4132A/41AS1/S2Maior capacidade de interrupçãoKH32-T203/SGZ006E
KG64/KG8064A/80AS2/S3Heavy load breakingKG80-T203/SGZ006E
KG100/KG125100A/125AS3/S4Medium high current breakingKG125-T203/SGZ006E
KG200/KG250200A/250AS4/S5Large equipment power controlKG250-T203/SGZ006E
KG400/KG630400A/630AS5/S6Factory branch power distributionKG630-T203/SGZ006E
KG800/KG1250800A/1250AS6/S7Large factory main circuit controlKG1250-T203/SGZ006E
  1. Regra de nomenclatura de modelo
Seção de códigoDefiniçãoExemplo
Código da sérieCG=Compact Control, CA=General Control, CAD=Self-cleaning Contact, CH=Lock Terminal, C=Load Switch, L=High Current IsolatorCG4, CA10, Capítulo 63, L630
Contact CodeA=No zero position, B=With zero position; 2nd digit=pole number, last two digits=position numberA251=2P4P non-zero
Operating Angle600=3×60° total 180°, 620=Mixed angle600=4 positions
Mounting CodeFS2=Central locking, FT2=Flange locking, FS1=Front lockingFS2=Central lock mount
Handle CodeE=Standard handle, EAO=EAO compatible handle, G521=Rotary handleE=Standard handle

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado