Carlo Gavazzi WM12-96.AV5.3.3.X Multi-functional Power Meter - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Carlo Gavazzi WM12-96.AV5.3.3.X Multi-functional Power Meter - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

medidor de eletricidade/elétrica/

Carlo Gavazzi WM12-96.AV5.3.3.X Multi-functional Power Meter

Carlo Gavazzi WM12-96.AV5.3.3.X is a 96×96mm panel-mounted three-phase multi-functional power meter. It adopts TRMS True RMS measurement technology, designed for 400V three-phase four-wire systems, with 230V AC power supply and no RS485 communication function. Its core advantages include high-precision measurement (Voltage/Current ±0.5% FS), multi-parameter display (12 measuring pages), wide measuring range (0.03-6Uma corrente) e alto ...

  • Detalhes do produto

Carlo Gavazzi WM12-96.AV5.3.3.X is a 96×96mm panel-mounted three-phase multi-functional power meter. It adopts TRMS True RMS measurement technology, designed for 400V three-phase four-wire systems, with 230V AC power supply and no RS485 communication function. Its core advantages include high-precision measurement (Voltage/Current ±0.5% FS), multi-parameter display (12 measuring pages), wide measuring range (0.03-6Uma corrente) and high protection degree (IP65 front panel). It is ideally applied in industrial automation, edifícios comerciais, data centers and OEM equipment. It can monitor power parameters in real time, help users optimize energy consumption and reduce operating costs.

  1. Definição de código de modelo
SeçãoCódigoDescrição
Código da sérieWM12-96Carlo Gavazzi WM12 series 96×96mm panel-mounted multi-functional power meter
Range CodeAV5380/660V line-line, 5(6)A AC current input, suitable for 400V power system
Tipo de sistema3Sistema trifásico de quatro fios (configurable as three-phase three-wire, ARON, two-phase or single-phase)
Tipo de fonte de alimentação3230V AC ±15% +10%, 50-60Hz (Code A=24VAC, B=48VAC, C=115VAC, D=18-60VDC)
Function OptionXWithout RS485 output (S=With RS485 MODBUS/JBUS output)

Número do pedido: WM12-96AV533X (Standard single package)

  1. Main Technical Specifications
CategoriaItemValorRemark
Basic InfoTipo de produtoThree-phase multi-functional power meterBuilt-in programming keypad, TRMS true RMS measurement
Mostrar14mm LED, 3×3 digitsRefresh rate: 700EM, 12 measuring pages
Tipo de montagemPanel mountingDimensão:96×96×63mm, Cut-out size:61.4×61.4mm
Classe de ProteçãoFrente IP65, Terminal IP20Comply with NEMA4x/12 standard
Electrical SpecsFaixa de tensão380/660V L-L, 185-460V L-NAV5 range, Precisão: ±0.5% FS +1 digit
Faixa Atual5(6)A AC, Phase current:0.03-6UM, Neutral current:0.09-6UMPrecisão: ±(0.5% FS +1 digit) within 0.25-6A
Tensão de alimentação230V AC ±15% +10%, 50-60HzConsumo de energia:4.5VA
Measured ParametersTensão, Atual, Poder, Fator de potência, Freqüência, Demanda, Maximum valueSystem-wide & phase-separated measurement supported
PrecisãoActive/Apparent Power±(1% FS +1 digit) (0.25-6UM)±(1% FS +5 dígitos) at 0.03-0.25A
Reactive Power±(2% FS +1 digit) (0.25-6UM)±(2% FS +5 dígitos) at 0.03-0.25A
Freqüência±0.1% Hz (48-62Hz)Sampling:1400 samples/s@50Hz, 1700 samples/s@60Hz
Neutral Current±(1.5% FS +1 digit) (0.25-6UM)±7 digits at 0.09-0.25A
ComunicaçãoInterfaceNenhum (X version)S version: RS485, MODBUS/JBUS, 9600 taxa de transmissão
Distância de comunicaçãoMax 1200m for S version, 2/4-wire connection
Ambient SpecsTemperatura operacional-5℃ ~ +50℃RH<90% non-condensing @40℃
Temperatura de armazenamento-30℃ ~ +60 ℃RH<90% non-condensing @40℃
Classe de isolamentoOvervoltage Category III (CEI 60664)Withstand 4000VAC between input and power supply for 1 minuto
Physical SpecsMaterial da HabitaçãoSelf-extinguishing ABS (UL 94 V-0)Peso: approx.400g (with package)
TerminaisTipo de parafusoMax cable cross-section:2.5mm², 5(6)A current input
CertificaçãoCESimComply with EN50084-1 Class A, EN61000-6-2 Class A
ULSimcULus certified, meet North American safety standards
EMC StandardComply with EN61000-4-51.2/50μs surge immunity
  1. Full Model List of WM12-96 Series
Range CodeTipo de sistemaFonte de energiaFunçãoModeloNúmero do pedido.
AV53(3-fase 4 fios)UM(24VAC)X(No RS485)WM12-96.AV5.3.A.XWM12-96AV53AX
S(RS485)WM12-96.AV5.3.A.SWM12-96AV53AS
B(48VAC)XWM12-96.AV5.3.B.XWM12-96AV53BX
SWM12-96.AV5.3.B.SWM12-96AV53BS
C(115VAC)XWM12-96.AV5.3.C.XWM12-96AV53CX
SWM12-96.AV5.3.C.SWM12-96AV53CS
3(230VAC)XWM12-96.AV5.3.3.XWM12-96AV533X
SWM12-96.AV5.3.3.SWM12-96AV533S
D(18-60CCV)XWM12-96.AV5.3.D.XWM12-96AV53DX
SWM12-96.AV5.3.D.SWM12-96AV53DS
AV63(3-fase 4 fios)3(230VAC)XWM12-96.AV6.3.3.XWM12-96AV633X
SWM12-96.AV6.3.3.SWM12-96AV633S

Modelos Especiais: WM12-DIN (DIN rail type), WM14-96 (with 15th harmonic analysis)

  1. Substituição & Modelos Equivalentes

4.1 Internal Carlo Gavazzi Replacement

Modelo AntigoNovo modeloReplacement Description
WM1-96WM12-96Upgraded true RMS measurement, maior precisão, added demand & max value display
WM12-96.AV5.3.D.SWM12-96.AV5.3.D.STotalmente compatível, optimized firmware, support latest MODBUS protocol

4.2 Cross-brand Equivalent

MarcaModelo EquivalenteVantagens
SchneiderPM2000More cost-effective, higher front IP65 protection
Siemens7KM2112Support more system types including ARON & two-phase, flexible programming
ABBE20012 display pages for clearer reading, standard 96×96mm mounting size
  1. Campos de aplicação & Cases

5.1 Aplicativos recomendados

AplicativoTypical Working ConditionVantagens
Automação IndustrialMotor control center, distribution cabinet, PLC systemTRMS measurement, perfect for non-linear loads with high precision
Edifícios ComerciaisCentral air conditioning, lighting system, elevator control3-phase 4-wire measurement, monitor unbalanced load, IP65 suit for machine room
Energia RenovávelPV inverter, wind power systemDemanda & peak value monitoring, support single/three-phase systems
Centro de dadosUPS system, server cabinet power distributionAlta precisão, low power consumption 4.5VA, stable 24h operation
OEM EquipmentIndustrial machinery, equipamento médico, testing instrumentStandard 96×96mm easy integration, optional RS485 communication

5.2 Not Recommended Applications

High voltage system (over 660V L-L, voltage transformer required)

High current system (over 6A, current transformer required)

Explosion hazardous area (non-explosion-proof design)

Underwater or long-term humid environment (only IP20 for terminals)

5.3 Casos de aplicação

Caso 1: Motor Control Center Renovation for Automobile Factory

Original equipment: Analog pointer meters with inaccurate reading and no data recording

Solução: WM12-96.AV5.3.3.S with RS485 + SCADA system

Effect: Real-time monitor three-phase current, tensão e potência, detect unbalanced load, save 15% energia, annual electricity saving about 80,000 RMB

Caso 2: Energy Management System for Commercial Complex

Demanda: Monitor power parameters of distribution cabinets on 12 floors, remote meter reading

Solução: 12 sets WM12-96.AV5.3.3.S connected to central controller via MODBUS bus

Effect: Auto generate energy consumption report, identify high-energy areas, optimize power distribution, save 20% energy yearly

  1. Air Shipment Compliance & Certificação

6.1 Shipping Confirmation

ItemStatusExplicação
Built-in Lithium BatteryNãoExternal power supply only
Dangerous Goods ClassificationNon-dangerous goodsComply with IATA DGR rules, no special shipping limit
Transport RestrictionNenhumShipped as general electronic goods
EmbalagemStandard anti-static packagePrevent static damage during transit

6.2 Documentos de Certificação

CE Certificate: Available on official Carlo Gavazzi website (Doc ID:WM12 96 DS ENG 100317)

UL Certificate: Apply via global Carlo Gavazzi support center

Manufacturer Declaration: Include EMC, safety and RoHS compliance statement

  1. Diretrizes de seleção
  2. Range Selection: AV5 for 400V system (380/660V L-L), AV6 for 100V system (120/208V L-L)
  3. Combinação de poder: Select A/B/C/3/D code according to on-site power supply to avoid damage
  4. Comunicação: Choose S version for remote monitoring, X version for local display only
  5. Montagem: Panel cut-out size 61.4×61.4mm; current signal must connect via CT, direct connection forbidden
  6. System Setting: Reset via keypad to three-phase three-wire, ARON, two-phase or single-phase as required
  7. Acessórios correspondentes
AcessórioModeloFunção
Transformador atualCT-500/5500A/5A for large current measurement
Voltage TransformerVT-400/100400V/100V for high voltage measurement
Módulo de ComunicaçãoRS485-USBConnect meter to PC for parameter setting & data reading
Kit de montagemWM12-MOUNTFixing screws and gaskets for panel installation
Software de configuraçãoGavazzi Config ToolRemote parameter setting and file generation

Full Model List of Carlo Gavazzi Multi-functional Power Meters

  1. General Coding Rule
SeçãoCódigoSignificado
SérieWM12-9696×96mm panel type
WM12-DINDIN rail type (4 módulos)
FaixaAV5380/660V L-L, 400V system
AV6120/208V L-L, 100V system
Sistema1Monofásico
2Three-phase three-wire
3Three-phase four-wire
PoderA=24VAC, B=48VAC, C=115VAC, 3=230VAC, D=18-60VDC
FunçãoX=No RS485, S=With RS485 MODBUS
  1. Complete WM12-96 & WM12-DIN Model List

WM12-96 Panel Mount

AV5 Series (400V System)

All single-phase / trifásico de três fios / three-phase four-wire models with all power supply & communication options are fully listed as above.

AV6 Series (100V System)

Full range models are available in single-phase, three-phase three-wire and three-phase four-wire types.

WM12-DIN Rail Mount

Mainly three-phase four-wire AV5 & AV6 versions with all power supply and communication options.

  1. Extended High-end Models
ModeloRecursoNúmero do pedido.
WM14-96.AV5.3.3.S15th harmonic analysisWM14-96AV533S
WM30-96.AV5.3.3.S0.2 alta precisão, 32nd harmonic FFT analysisWM30-96AV533S