Mitsubishi FR-A840-18.5K High-Performance Inverter - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Mitsubishi FR-A840-18.5K High-Performance Inverter - Contator,disjuntor,sensor,Codificador,CLP,Conversor

inversor solar/

Mitsubishi FR-A840-18.5K High-Performance Inverter

França:Inverter A:A800 high-performance series 8:8ª geração 4:3-phase 400V class (380~500V) 0:Standard open type, IP20 18.5K:ND rated applicable motor power 18.5kW -1:Japanese domestic specification (corresponding China domestic model: FR-A840-00470-2-60) Core Electrical Specifications Input: 3-phase AC380~500V, 50/60Hz ND (Serviço normal, padrão de fábrica): For 18.5kW motor, rated output current 38A, 150% overload for 60s LD (Serviço leve): Unidades ...

  • Detalhes do produto

França:Inversor

UM:A800 high-performance series

8:8ª geração

4:3-phase 400V class (380~500V)

0:Standard open type, IP20

18.5K:ND rated applicable motor power 18.5kW

-1:Japanese domestic specification (corresponding China domestic model: FR-A840-00470-2-60)

Especificações elétricas principais

Entrada: 3-phase AC380~500V, 50/60Hz

DE (Serviço normal, padrão de fábrica): For 18.5kW motor, rated output current 38A, 150% overload for 60s

LD (Serviço leve): Drives up to 22kW, corrente nominal 43A; SLD super light duty max 47A

HD Heavy duty mode: For 15kW motor, 31UM, 180% overload for 60s (selected for cranes, extruders and other high-shock loads)

Frequência de saída: 0.2~590Hz; max 400Hz under vector control

Built-in braking transistor (18.5kW model includes built-in braking transistor, external braking resistor connectable)

Classe de proteção: IP20 (montagem em gabinete)

Desempenho de controle

  1. Controle vetorial sem sensor: High low-speed torque, 200% saída de torque a 0,5 Hz; supports asynchronous motor + PM permanent magnet synchronous motor drive, motor auto-tuning
  2. Controle V/F, advanced magnetic flux vector; closed-loop vector available with encoder option card FR-A8AP
  3. Built-in simple PLC (sequence operation function), capable of simple logic programming to reduce external PLC I/O points
  4. Speed response up to 50Hz, suitable for high-precision tension, fuso, winding and positioning applications

Comunicação & Expansão

Standard RS485 (Modbus RTU)

Cartões de comunicação opcionais: Link CC, CC-Link IE Field, Profinet, Profibus-DP, DeviceNet, etc..

Terminais: Entradas digitais, saídas de relé, open-collector outputs, AM analog voltage monitor, CA analog current monitor

Opções: Operation panel, braking resistor FR-ABR, Filtro EMC, Reator CC, encoder interface card

Cenários típicos de aplicação (High Search Keywords)

Spindle drive, guindaste, winch, extrusora, centrifuge, fã & bomba de água, belt conveyor, controle de tensão, máquinas de embalagem, compressor de ar. The A800 series is positioned as a high-performance heavy-duty general inverter, superior to F800 for loads requiring fast dynamic response.

Especificações Ambientais

Temperatura operacional: -10℃~+50℃ (sem glacê); SLD mode upper limit +40℃

Temperatura de armazenamento: -20℃~+65℃

Umidade: Max 95%RH, sem condensação; altitude ≤1000m (derating required above 1000m)

Substituição & Notas de migração

  1. Substituição de modelo legado: FR-A740-18.5K upgraded to this model; mounting dimensions and terminal definitions differ, parameters cannot be copied directly and motor auto-tuning must be re-performed
  2. Japanese `-1` vs domestic `-2-60`: Same hardware core, different firmware/standards, nameplate and factory preset parameters. Cannot be interchanged for procurement; region code must be distinguished during ordering
  3. Referência alternativa nacional: Inovação MD880, Infineon platform high-performance inverters

Quick Reference for Common Faults

E.OC1: Sobrecorrente durante a aceleração; E.OC2: Overcurrent at constant speed; E.OC3: Overcurrent during deceleration

E.OV: Sobretensão no barramento CC (high inertia loads require braking resistor)

E.THT: Inverter heatsink overheat (falha do ventilador, blocked cooling duct)

E.THM: Motor electronic thermal overload

Dicas de seleção

Cargas de choque & frequent start-stop → Use HD mode, it is recommended to select one higher capacity grade

Stable loads such as fans and pumps → Use LD/SLD for higher available motor power

High inertia shutdown → Braking resistor mandatory; 18.5kW unit has built-in braking transistor, no separate braking unit needed

Campos de aplicação de Mitsubishi FR-A840-18.5K-1 (A800 18.5kW 400V Class)

The FR-A840 is a high-performance heavy-duty vector inverter. Featuring high low-speed torque, resposta rápida, support for torque/tension control and built-in braking transistor, it is ideal for heavy impact, controle de tensão, spindle and lifting applications, and also supports energy-saving retrofit for fans and pumps.

  1. Guindaste & Equipamento de elevação (HD Heavy Duty Mode Preferred)

Gantry crane, overhead crane, small winch, Empilhador AS/RS, içar

Características: High low-speed torque, anti-sway control, load holding for heavy weights, carga de alta inércia, parada frequente; 18.5kW built-in braking transistor realizes fast braking with braking resistor

Application keywords: Guindaste, winch, stacker, elevação, anti-sway

  1. Web Tension Control Industry (Enrolamento & Descontraindo)

Fabricação de papel, filme, tecido não tecido, adhesive tape, arame & cable drawing, máquina de impressão, slitter

Supports sensorless tension control, dancer roller feedback, line speed synchronization, reduces web tension fluctuation and ensures uniform winding quality

Application keywords: Enrolamento, desenrolando, corte, revestimento, wire drawing, impressão, controle de tensão

  1. Máquina-ferramenta & Equipamento de processamento

CNC machine spindle, moedor, fresadora, stone cutting machine, engraving machine

Wide speed range, resposta rápida, supports asynchronous and PM motor drive; closed-loop vector available with FR-A8AP encoder card for high-precision spindle speed regulation

Application keywords: Machine spindle, grinding machine, high-speed cutting

  1. Extrusion & Rubber/Plastics Machinery

Plastic extruder, rubber extruder, pelletizer, internal mixer

Large load fluctuation, high starting torque requirement, stable screw speed control to stabilize extrusion pressure and improve product consistency

  1. Transporte & Automação Logística

Transportador de correia, roller conveyor, automated warehouse, sorting line, heavy-duty pallet conveyor

Multi-drive synchronous control, soft start to reduce mechanical shock; supports PM permanent magnet motor energy-saving solution

Application keywords: Heavy-duty conveyor, linha de rolo, triagem logística

  1. General Fluid Equipment (Energy-saving Retrofit, LD/SLD Light Duty Mode)

Ventilador grande, process water pump, compressor de ar, central air conditioning circulating pump

PID constant pressure/flow control, optimized excitation for energy saving; suitable for energy-saving retrofit of constant torque / cargas de torque variável

Observação: F800 series is preferred for fans and pumps; A800 advantage is versatile capability for heavy-duty applications

  1. Other Heavy Industry Applications

Press machine, auxiliary drive for shield machine, misturador, centrifuge, marine deck auxiliary machinery (with filter to meet class society certification)

Heavy-duty host for food packaging, large mixing equipment

Seleção & Application Key Points

  1. Cargas de choque, elevação, extrusão, enrolamento: HD heavy duty mode, 180% overload for 60s
  2. Stable fan/pump loads: LD/SLD light duty mode for energy saving priority
  3. High inertia shutdown (winch, enrolamento): External braking resistor required, braking transistor built-in
  4. Japanese FR-A840-18.5K-1 shares identical hardware with China domestic model but differs in factory preset parameters and standards; distinguish region version for project selection.
  5. FR-A840 (3-fase 400V, Japanese domestic suffix -1, FR-A840-18.5K-1 listed here)

Power Model List (ND rated motor power)

  1. FR-A840-0.4K-1
  2. FR-A840-0.75K-1
  3. FR-A840-1.5K-1
  4. FR-A840-2.2K-1
  5. FR-A840-3.7K-1
  6. FR-A840-5.5K-1
  7. FR-A840-7.5K-1
  8. FR-A840-11K-1
  9. FR-A840-15K-1
  10. FR-A840-18.5K-1 (Seu modelo)
  11. FR-A840-22K-1
  12. FR-A840-30K-1
  13. FR-A840-37K-1
  14. FR-A840-45K-1
  15. FR-A840-55K-1
  16. FR-A840-75K-1
  17. FR-A840-90K-1
  18. FR-A840-110K-1
  19. FR-A840-132K-1
  20. FR-A840-160K-1
  21. FR-A840-185K-1
  22. FR-A840-220K-1
  23. FR-A840-250K-1
  24. FR-A840-280K-1

Corresponding China Domestic Models (Sufixo -2-60, current code type)

PoderModelo DomésticoCódigo Atual
0.4KFR-A840-00023-2-6023
0.75KFR-A840-00038-2-6038
1.5KFR-A840-00052-2-6052
2.2KFR-A840-00083-2-6083
3.7KFR-A840-00126-2-60126
5.5KFR-A840-00170-2-60170
7.5KFR-A840-00250-2-60250
11KFR-A840-00310-2-60310
15KFR-A840-00380-2-60380
18.5KFR-A840-00470-2-60470
22KFR-A840-00620-2-60620
30KFR-A840-00770-2-60770
37KFR-A840-00930-2-60930
45KFR-A840-01160-2-601160
55KFR-A840-01800-2-601800
75KFR-A840-02160-2-602160
90KFR-A840-02600-2-602600
110KFR-A840-03250-2-603250
132KFR-A840-03610-2-603610
160KFR-A840-04320-2-604320
185KFR-A840-04810-2-604810
220KFR-A840-05470-2-605470
250KFR-A840-06100-2-606100
280KFR-A840-06830-2-606830
  1. Other A800 Series Models (Full Product Line)
  2. FR-A820 (3-phase 200V class): 0.4K~90K, sufixo -1 (japonês) / -2-60 (China)
  3. FR-A840 (3-fase 400V, main model as listed above): 0.4K~280K
  4. FR-A842 (High power split type, 400V): 315K~500K (separate rectifier + inverter unit)
  5. FR-A846 (Dust-proof 400V): 0.4K~132K, enhanced cabinet dust resistance
  6. FR-A840M (Module type 400V): 160K, 200K, common DC bus dedicated
  7. Derivative suffixes:

E: Global general version

GF: Built-in CC-Link IE Field

GN: Built-in CC-Link

CRN: Class certified marine model

III. Notas principais

  1. Explicação do sufixo: -1 = Japanese domestic unit; -2-60 = China mainland unit. Hardware identical, factory parameters and safety standards differ; cannot be directly interchanged for purchase.
  2. Models 18.5kW and below have built-in braking transistor; 22kW and above high power models require separate braking unit.
  3. HD mode for heavy-duty applications; LD/SLD light duty for fans & pumps with derating operation.

Mitsubishi FR-A840-18.5K-1 Installation & Commissioning Full Tutorial

Descrição do modelo: FR-A840-18.5K-1, 3-fase 400V, 18.5kW, built-in braking transistor (P/+, PR terminals for braking resistor); Japanese version, hardware identical to China FR-A840-00470-2-60, different factory default parameters.

⚠️ Safety Precaution: All wiring work must be performed with power off; capacitors retain high voltage after main power cut-off. Espere pelo menos 10 minutes and confirm charge lamp is OFF before opening cover.

  1. Instalação Mecânica (Cabinet Mounting IP20)
  2. Requisitos ambientais de instalação

Orientação de montagem: Vertical wall mount, montagem horizontal ou invertida proibida; fixed on non-combustible rigid steel plate

Temperatura ambiente: Operation -10℃~+50℃ (sem glacê); SLD light duty ≤40℃; cabinet ventilation required

Ambiente: Mantenha-se longe da poeira, névoa de óleo, gás corrosivo, luz solar direta; humidity ≤95%RH non-condensing; altitude ≤1000m, derating required above 1000m

Cabinet clearance: ≥100mm free space top & parte inferior para dissipação de calor; multiple units can be mounted side-by-side at ambient temperature, ≥50mm gap recommended for high-temperature environments

  1. Etapas de instalação
  2. Unpacking inspection: Check housing integrity, fan intact, operation panel and terminal cover complete; verify nameplate model FR-A840-18.5K-1
  3. Position and drill holes, fasten with M6/M8 screws, tighten torque per manual to prevent vibration loosening
  4. Remove front cover for main circuit and control circuit wiring; reinstall cover after wiring completion
  5. Install optional parts (se necessário): resistor de frenagem, Filtro EMC, Reator CC, FR-A8AP encoder card (for closed-loop vector)
  6. Fiação Elétrica (Key Terminals)

Terminais do Circuito Principal

R/L1, S/L2, T/L3: 3-phase 380~500V power input

Você, V, C: Conecte ao motor assíncrono trifásico; Do NOT install capacitor or surge absorber on inverter output side; this will damage inverter

P/+, PR: Terminais do resistor de frenagem (built-in braking transistor); remove PR-PX jumper before connecting braking resistor; braking resistor mandatory for winch, winding and high inertia loads

Terminal terrestre: Reliable earth connection required, earth resistance ≤10Ω; separate grounding for inverter and motor to reduce interference

Terminais do Circuito de Controle (Comumente usado)

STF: Forward run; STR: Reverse run; SD: Digital input common terminal (sink type default)

RH/RM/RL: Multi-speed terminals

AU: Current input selection; terminal 4: 4~20mA; terminal 2: 0~10V voltage reference

SOU: Analog voltage monitor; CA: Analog current monitor

ABC: Fault relay output (B-C closed, A-C open during fault)

Especificação de fiação: Main power cable recommended 10mm²; shielded motor cable preferred; separate routing for power cable and control cable; shielded control cable with single-end grounding.

III. Inspeção pré-ligação (Mandatory to Prevent Damage)

  1. Use multimeter in power-off state: No short circuit between R/S/T, U/V/W; no short circuit between P/+ and PR; no short circuit to ground
  2. Confirm motor wiring correct, mechanical load decoupled (Decouple mechanical load for first trial run, test motor without load)
  3. Verify braking resistor wiring without short circuit; all terminal screws tightened
  4. Confirm input power AC380~480V, no overvoltage
  5. Ligar & Basic Parameter Setting (PU Panel Commissioning)

Panel keys: MODO, SET confirm, ESC exit, PU/EXT toggle, ajuste do botão; PU = panel control; EXT = external terminal control

Etapa 1: Ligar, parameter reset (optional for new unit; recommended for used unit or motor replacement)

Enter parameter, set Pr.ALLC=1 for all parameter clear; power cycle to restore factory settings

Etapa 2: Basic motor nameplate parameters (Core for vector control, must be filled)

Parâmetro Não.Nome do parâmetroValor (from motor nameplate)
Pr.80Potência nominal do motor18.5 (kW)
Pr.81Tensão nominal do motor380/400V
Pr.82Corrente nominal do motorMotor nameplate rated current
Pr.83Frequência nominal do motor50Hz
Pr.84Velocidade nominal do motorNameplate speed
Pr.9Electronic thermal overload protection currentCorrente nominal do motor

Etapa 3: Operation Mode Pr.79 (Mais comum)

Pr.79=0: PU/EXT switchable (padrão de fábrica)

Pr.79=1: PU panel mode, start/stop and frequency set via panel, for commissioning

Pr.79=2: External terminal mode, STF/STR start-stop, potentiometer /4-20mA frequency reference, normal field operation

Pr.79=3: Terminal start, panel knob frequency setting (combined mode)

Etapa 4: Control Mode Selection (A800 core)

Pr.800=0: Controle V/F (fãs, bombas, simple conveyor)

Pr.800=20: Controle vetorial sem sensor (asynchronous motor), recommended for crane, extrusora, enrolamento, high low-speed torque

Pr.800=30: Vetor de circuito fechado (FR-A8AP encoder card required for motor with encoder)

Step5: Acceleration / Deceleration, Frequency Limit

Pr..0: Torque boost; normally not increased under vector control

Pr.1: Upper frequency limit; Pr.2: Lower frequency limit

Pr.7: Tempo de aceleração; Pr.8: Tempo de desaceleração; extend deceleration time for high inertia loads and use braking resistor

  1. Motor Auto-Tuning (Mandatory for Vector Control, Critical Step)

Two auto-tuning types: Static auto-tuning (motor estacionário) and Rotational auto-tuning (motor rotating, maior precisão)

✅ Recomendado: Perform Rotational auto-tuning with load decoupled

  1. Set Pr.96=11 (Rotational auto-tuning for asynchronous motor), press SET
  2. Panel shows “READY”, press FWD start, inverter excites motor automatically, motor runs at low speed
  3. Process lasts dozens of seconds, panel displays END after completion → auto-tuning successful
  4. If ERR displayed: Check motor wiring, nameplate parameters, motor jamming, re-run auto-tuning

Static auto-tuning (when load cannot be decoupled): Pr.96=10; accuracy lower than rotational tuning

  1. No-load Trial Run (PU Mode)
  2. Pr.79=1, PU mode, confirm mechanical no-load, personnel keep clear of transmission mechanism
  3. Set target frequency (e.g.10Hz), press FWD forward run
  4. Monitor: Motor rotation direction, atual, vibração, barulho; check output frequency & current on panel
  5. Reverse test: REV.; stop by STOP
  6. Wrong rotation direction: Power off and swap U & V motor leads; Do NOT swap input R/S/T

Normal no-load current is 30%~60% of motor rated current; stop immediately if abnormal current occurs

VII. Comissionamento carregado (Switch to External Mode)

  1. Wire external terminals: STF-SD (forward switch), potentiometer to Terminal2 & 5 for 0~10V frequency reference
  2. Pr.79=2, switch to EXT external mode
  3. Low frequency trial run (5~10Hz) under load, monitor torque, current and alarms
  4. Gradually increase frequency and observe:

Heavy-duty applications (winch, extrusora): Enable HD heavy duty mode, 180% overload 60s

Fãs & bombas: LD/SLD light duty mode

  1. Tune acceleration/deceleration time and braking duty ratio; fine-tune tension parameters for tension control applications

VIII. Communication Commissioning (RS485/CC-Link/Profinet, Opcional)

  1. RS485 integrado: Modbus RTU, set station address, taxa de transmissão, parity bit
  2. Communication option cards (FR-A8NP Profinet, FR-A8NC CC-Link): Install when power off, configure parameters, communication address and parameter mapping
  3. Common Commissioning Alarm Troubleshooting

E.OC1: Sobrecorrente durante a aceleração; motor short circuit, atolamento mecânico, tempo de aceleração muito curto

E.OV: Sobretensão no barramento CC; high inertia shutdown, increase braking resistor capacity or extend deceleration time

E.THT: Inverter overheat; dano ao ventilador, duto de ar de resfriamento bloqueado

E.UVT: Subtensão; perda de fase de entrada, large voltage drop

E.ALM: Sobrecarga do motor; incorrect Pr.9 thermal setting, mechanical binding

  1. Handover & Documentação
  2. Upload parameters to operation panel for backup (parameter copy), save parameter document
  3. Record auto-tuning result, motor parameters and alarm history
  4. Reaperte todos os terminais, reinstall cover, clean cabinet debris

Notas importantes

  1. Japanese FR-A840-18.5K-1 has different safety specs and factory preset settings vs China -2-60 modelo. Do not directly download Chinese project parameter files; re-run motor auto-tuning.
  2. 18.5kW unit has built-in braking transistor, but braking resistor needs separate selection, não pode ser omitido.
  3. Motor auto-tuning is mandatory for vector control, otherwise low-speed torque is insufficient and trip may occur.

Anterior:

Deixe uma resposta

Deixe um recado