Relé de sobrecarga térmica Schneider LRE16N - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Relé de sobrecarga térmica Schneider LRE16N - Contator,disjuntor,sensor,Codificador,CLP,Conversor

elétrica/

Relé de sobrecarga térmica Schneider LRE16N

Observação: LRE16N is the domestic version of LRE16. The suffix N stands for China domestic model. Current setting range: 9~13 A, Class 10A differential thermal relay with phase failure protection, directly compatible with LC1E series contactors. Core Technical Parameters Setting current range: 9~13 A (suitable for approx. 5.5kW 400V three-phase motors) Classe de viagem: Classe 10A ...

  • Detalhes do produto

Observação: LRE16N is the domestic version of LRE16. The suffix N stands for China domestic model. Current setting range: 9~13 A, Class 10A differential thermal relay with phase failure protection, directly compatible with LC1E series contactors.

  1. Parâmetros técnicos principais

Configurando o intervalo atual: 9~13 A (suitable for approx. 5.5kW 400V three-phase motors)

Classe de viagem: Classe 10A (CEI 60947-4-1)

Tensão operacional nominal Ue: ≤690V CA

Insulation voltage Ui: 690V; Tensão suportável de impulso Uimp: 6kV

Freqüência: 50/60Hz

Contatos auxiliares: 1NÃO + 1NC (97-98 NÃO, 95-96 NC); conventional thermal current 5A for control circuit

Proteção contra falha de fase: Reliable tripping when two phases reach 130% Ir and the third phase has zero current

Ambient temperature compensation: -20℃~+60℃

Modo de reinicialização: Reinicialização manual (red STOP button) + automatic reset switch; with trip indicator window

Fiação: Terminais de parafuso; circuito de energia: 1.5~6mm²; circuito de controle: 1~2,5 mm²; torque de aperto: 1.7N·m

Dimensões gerais: W45mm × D70mm × H44.5mm; Peso líquido: aprox.. 124g

  1. Contatores compatíveis (Direct Plug-in Mounting)

LC1E06 / LC1E09 / LC1E12 / LC1E18 / LC1E25 / LC1E38 (EasyPact TVS E series)

Cannot be directly plugged onto LC1D or LC1N due to different base design.

  1. Explicação do código do modelo

LRE: EasyPact TVS economical thermal relay series

16: Frame size code, corresponding to 9–13A current range

N: Domestic version suffix (Overseas model is marked LRE16; electrical performance is identical)

  1. Alternative Replacements
  2. Atualização da mesma série: LRQ16 (new Easy TeSys TVQ model, direct replacement for LRE)
  3. Same current cross-series: LRD16 (TeSys D, 9–13A, fits LC1D); base cannot be directly interchanged
  4. Alternativas domésticas: Chint NR2-25 (9–13A), Delixi CDR2-25 (9–13A)
  5. Matching Fuse Protection

Circuito principal: gG 25A / aM 16A

Circuito de controle: gG 5A

  1. Aplicações Típicas

Sobrecarga & phase-failure protection for three-phase asynchronous motors such as fans, bombas de água e transportadores; used in direct-on-line or star-delta economical starter circuits.

Installation Procedures for Schneider LRE16N Relé de sobrecarga térmica

Two mounting methods: Direct plug-in below LC1E contactor (preferido) / Independent DIN rail mounting (requires accessory LAEB1N)

⚠️ Safety prerequisite: Corte a energia, lock out & tag out, verify zero voltage on main and control circuits.

Método 1: Montagem de plug-in (With LC1E Contactor, Recomendado)

  1. Pré-verificação

Confirm the contactor is LC1E series (LC1E06/09/12/18/25/38). LRE16N only fits LC1E; not compatible with LC1D / LC1N. Verify the setting range 9–13A matches the motor rated current.

  1. Contactor Preparation

Mount LC1E onto 35mm DIN rail and lock firmly; loosen the three main terminal screws T1/T2/T3 (no need to remove fully).

  1. Clip into position

Align the three conductive pins of LRE16N with T1/T2/T3 terminal holes on the contactor, engage the rear latch into the contactor slot, push upward until you hear an audible click confirming full locking. Ensure pins are fully inserted into terminals.

  1. Aperte os terminais do circuito principal

Tighten T1/T2/T3 screws sequentially with torque 1.7 N·m. Cable size: 1.5~6mm² for main circuit.

  1. Main circuit output wiring

Bottom terminals of thermal relay: 2T1、4T2、6T3 → connect to three motor phases.

  1. Fiação de contato auxiliar (95-96 / 97-98)

95-96 (NC normalmente fechado): Series-connected into contactor coil circuit; opens to stop the motor upon overload tripping.

97-98 (NÃO Normalmente aberto): Connect to fault indicator lamp or PLC signal input.

Control circuit wire: 1~2,5 mm²; tightening torque also 1.7N·m.

  1. Reset mode selection

Side dip switch: H = Manual Reset (recommended for all motor circuits); A = Automatic Reset. Default setting: H.

  1. Current setting

Rotate the front adjustment knob to align the scale with motor nameplate rated current (within 9~13A).

  1. Teste mecânico (Power OFF)

Press the red STOP button to simulate tripping: 95-96 opens and 97-98 fecha. After reset, contacts return to original state.

  1. Pre-power inspection

Check phase sequence, no loose terminals or short circuits; confirm trip indicator is in normal position.

Método 2: Independent DIN Rail Mounting (Not fitted under contactor)

  1. Install the dedicated mounting base LAEB1N first.
  2. Clip LAEB1N onto DIN rail and lock securely.
  3. Snap LRE16N into the LAEB1N base.
  4. Fiação do circuito principal: L1/L2/L3 incoming power to the top terminals of thermal relay; bottom 2T1/4T2/6T3 connect to the contactor.
  5. Auxiliary wiring, current setting and reset selection follow the same steps above.

Commissioning Steps After Power-on

  1. Jog the motor with no load first to confirm correct rotation direction.
  2. Run motor under load and measure three-phase operating current with clamp meter.
  3. Fine-tune the setting knob if operating current stays close to the set value.
  4. Perform overload test (se disponível) to verify protection function.
  5. Record the final set current value.

Proibições de instalação & Notas importantes

  1. Do not install directly above heat-generating components. Temperatura ambiente operacional: -20~+60℃. Leave ventilation gaps between adjacent components.
  2. This thermal relay only provides overload + proteção contra falha de fase; it does NOT offer short-circuit protection. Fuses or motor circuit breakers must be installed upstream.
  3. Never force-tighten terminal screws when the plug-in pins are misaligned; this will damage pins and cause overheating and burning.
  4. Auxiliary contacts cannot carry heavy loads; rated thermal current is limited to 5A.
  5. Recheck the current setting every time the motor or cable is replaced.

Full LRE Series (TVS EasyPact) Thermal Overload Relay List

General note: Domestic models carry suffix N (LRExxN). All are Class10A differential relays with phase-failure protection, 1Contatos auxiliares NO+1NC. Direct plug-in only for LC1E contactors; not interchangeable with LC1D / LC1N.

Independent mounting accessory: LAEB1N for LRE01N~LRE35N; LAEB3N for LRE322N~LRE365N; LAES1/LAES2 adapter plates for high-current LRE480 series.

Grupo 1: Direct Plug-in for LC1E06 / LC1E09 / LC1E12 / LC1E18 / LC1E25 / LC1E38

ModeloFaixa de configuração atual (UM)Potência do motor correspondente (400V)
LRE01N0.10~0.160.03kW
LRE02N0.16~0.250.06kW
LRE03N0.25~0.400.09kW
LRE04N0.40~0.630.12~0,18kW
LRE05N0.63~1.00.25kW
LRE06N1.0~1.60.37kW
LRE07N1.6~2.50.55kW
LRE08N2.5~4.01.1kW
LRE10N4.0~6.02.2kW
LRE12N5.5~8.03kW
LRE14N7.0~10,04kW
LRE16N9.0~13.05.5kW
LRE21N12.0~18.07.5kW
LRE22N16.0~24.011kW
LRE32N23.0~32.015kW
LRE35N30.0~38.018.5kW

Grupo 2: Direct Plug-in for LC1E40 / LC1E50 / LC1E65 / LC1E80 / LC1E95

ModeloFaixa de configuração atual (UM)Potência do motor correspondente (400V)
LRE322N17~2511kW
LRE353N23~3215kW
LRE355N30~4018.5kW
LRE357N37~5022kW
LRE359N48~6530kW
LRE361N55~7037kW
LRE363N63~8045kW
LRE365N80~10455kW

Grupo 3: High-current LRE48x Series (LC1E120~LC1E630, Requires Adapter Plates)

ModeloFaixa de configuração atual (UM)Contator correspondenteMounting Accessory
LRE480N51~81LC1E120 / LC1E160LAES1
LRE481N62~99LC1E120 / LC1E160LAES1
LRE482N84~135LC1E120 / LC1E160LAES1
LRE483N124~198LC1E200LAES2
LRE484N146~234LC1E250 / LC1E300 / LC1E400LAES2
LRE485N174~279LC1E250 / LC1E300 / LC1E400LAES2
LRE486N208~333LC1E250 / LC1E300 / LC1E400LAES2
LRE487N259~414LC1E250 / LC1E300 / LC1E400LAES2
LRE488N321~513LC1E500LAES3
LRE489N394~630LC1E630LAES3

Full List of Compatible Contactors for LRE Series

Small frame: LC1E06N、LC1E09N、LC1E12N、LC1E18N、LC1E25N、LC1E38N

Quadro médio: LC1E40N、LC1E50N、LC1E65N、LC1E80N、LC1E95N

Large frame: LC1E120N、LC1E160N、LC1E200N、LC1E250N、LC1E300N、LC1E400N、LC1E500N、LC1E630N

Troubleshooting Guide for Schneider LRE16N (9~13A) Relé de sobrecarga térmica

Pré-requisito: Class10A differential design with phase failure protection; only fits LC1E contactors. Always cut off power and verify zero voltage before measurement. Distinguish between genuine overload and false tripping.

  1. Frequent Tripping After Motor Runs for a Period (Most Common Fault)

Causas

  1. Set current is too low: Knob scale lower than motor rated current on nameplate.
  2. Real motor overload: Bloqueio mecânico, damaged bearings, over-tight belts, pump blockage.
  3. Three-phase current unbalance, phase loss or low supply voltage.
  4. Parada frequente & operação jog; continuous high inrush current (Class10A is designed for normal starting; frequent jogging causes false tripping).
  5. Má ventilação do gabinete; mounted directly above contactors/breakers with high ambient temperature (>60℃).
  6. Poor plug-in connection or loose main terminals, creating high contact resistance and overheating.
  7. Excessive vibration causing internal mechanism misalignment.

Soluções

  1. Measure three-phase running current with clamp meter, set knob exactly to motor rated current (within 9–13A range).
  2. Disconnect mechanical load and test motor alone to rule out mechanical blockage; check three-phase voltage balance.
  3. Melhorar a ventilação do gabinete; leave cooling gaps between adjacent components; avoid mounting above heat-generating devices.
  4. Re-seat the relay until latch clicks; tighten main terminals strictly to 1.7N·m torque.
  5. For frequent start-stop applications: add start bypass circuit or replace with electronic thermal relay.
  6. No Tripping Under Motor Overload or Locked Rotor (Protection Failure)

Causas

  1. Setting current is set far higher than motor rated current.
  2. Wrong main wiring or loose terminals; actual motor current does not flow through the bimetallic element.
  3. Oxidized plug-in pins with poor contact; current does not fully pass through thermal elements.
  4. Bimetallic strip fatigue and aging after long-term high temperature.
  5. No tripping even with phase loss because current fails to reach the trip threshold.

Nota importante: LRE only provides overload & proteção contra perda de fase; short-circuit protection must rely on upstream fuses or circuit breakers.

Soluções

  1. Reset the set current; never set it higher than motor rated current.
  2. Power off and test three-phase continuity with multimeter; inspect plug-in pins for oxidation.
  3. Perform mechanical trip test via TEST button and check switching of 95-96 / 97-98 contatos.
  4. If the relay still fails to trip after successful manual test: replace LRE16N directly.
  5. Cannot Reset After Tripping

Causas

  1. Bimetallic strip has not cooled down immediately after tripping (3–5 minutes cooling time required before reset).
  2. Dip switch set to A (Redefinição automática) with jammed mechanism; or set to H (Redefinição manual) but red STOP button not fully pressed.
  3. Internal mechanical mechanism stuck, deformed or corroded.
  4. Trip indicator shows tripped state but auxiliary contacts are welded closed.

Soluções

  1. Cut off power and wait 3–5 minutes for full cooling before reset attempt.
  2. Confirm H/A selection: H = Manual Reset (requires pressing red STOP); A = Auto Reset after cooling.

⚠️ Auto reset mode poses unexpected restart risk; always use H manual reset for rotating machinery.

  1. If reset still fails after cooling and TEST button does not work: thermal relay is damaged and needs replacement.
  2. Abnormal Auxiliary Contacts (95-96 NC fails to open / 97-98 NO fails to close)

Fenómeno

Contactor remains energized after overload tripping; or fault alarm signal cannot be triggered.

Causas

  1. Wrong wiring on auxiliary terminals.
  2. Contact burning and welding.
  3. Trip mechanism moves properly but contact switching assembly fails.
  4. Loose control circuit terminals.

Soluções

  1. Desligar; press TEST button to simulate tripping and measure continuity of 95-96 e 97-98 with multimeter.
  2. Replace relay if contacts do not switch during test.
  3. Use 1~2.5mm² wire for control circuit; tighten terminals to 1.7N·m torque.
  4. Severe Overheating of Relay Housing

Causas

  1. Loose main terminals or poor plug-in connection leading to contact overheating.
  2. Motor continuously running at full load or overloaded condition.
  3. Undersized main cable cross-section.
  4. Poor heat dissipation with high ambient temperature.

Soluções

  1. Re-tighten terminals after power-off; inspect pins for black oxidation; replace immediately if pins are burned.
  2. Measure load current to confirm continuous overload status.
  3. Use 1.5~6mm² main circuit cables matched with operating current.
  4. Instant Tripping Upon Power-up Before Motor Starts

Causas

  1. Relay remains in tripped state without cooling and reset.
  2. Motor winding short circuit or earth leakage causing inrush current on closing.
  3. Missing phase or abnormal phase sequence on incoming three-phase supply.
  4. Internal short-circuit damage inside thermal relay.

Soluções

  1. Complete cooling and reset first before no-load test run.
  2. Test motor insulation with megger and check three-phase supply voltage.
  3. Disconnect motor and test relay function independently with TEST button.
  4. False Phase-loss Tripping While Three-phase Power Is Normal

Causas

  1. Loose terminal on one phase causing voltage drop, which is detected as phase loss.
  2. Severe three-phase current unbalance.
  3. Large voltage fluctuation on power supply.
  4. Aging relay with false differential phase-loss detection.

Soluções

  1. Measure three-phase voltage and current; tighten all terminals on contactor, thermal relay and motor terminals.
  2. Replace LRE16N if phase-loss tripping persists with balanced three-phase supply.

Quick Self-Check Procedure for LRE16N

  1. Cut off power and check trip indicator window.
  2. Press TEST button: auxiliary contacts must switch reliably.
  3. Cool down and reset; confirm mechanical rebound is smooth.
  4. Power on and measure three-phase operating current with clamp meter; compare with set value.
  5. Verify H/A reset dip switch (H manual reset recommended for all equipment).
  6. Confirm it is plugged onto LC1E contactor (not LC1D).

Avisos de segurança

Never use A auto-reset mode on belt conveyors and rotating equipment to prevent unexpected automatic restart and personal injury.

Do not disassemble and repair internal bimetallic components; substitua toda a unidade uma vez que falhou.

Install aM fuses or motor protection circuit breakers upstream; LRE thermal relay cannot provide short-circuit protection.

Anterior:

Deixe uma resposta

Deixe um recado