Contato Fênix 2320157 Redundancy Module - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Contato Fênix 2320157 Redundancy Module - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

Contato Fênix 2320157 Redundancy Module

This is the Phoenix Contact QUINT series diode redundancy module (QUINT-DIODE/12-24DC/2X20/1X40). It is designed for 12–24VDC dual power parallel redundancy or power superposition, supporting 2×20A redundancy mode or 1×40A capacity expansion mode. It adopts DIN rail mounting with IP20 protection degree, suitable for high-availability power supply scenarios such as industrial automation and process control. Modelo ...

  • Detalhes do produto

This is the Phoenix Contact QUINT series diode redundancy module (QUINT-DIODE/12-24DC/2X20/1X40).

It is designed for 12–24VDC dual power parallel redundancy or power superposition, supporting 2×20A redundancy mode or 1×40A capacity expansion mode. It adopts DIN rail mounting with IP20 protection degree, suitable for high-availability power supply scenarios such as industrial automation and process control.

  1. Definição de segmento de modelo
SegmentoSignificado
QUINTPhoenix Contact high-performance power supply series, representing high quality and high reliability
DIODEDiode-type redundancy module; realizes electrical isolation between power supplies via diodes
12-24CCApplicable DC input voltage range: 12–24V DC (ampla gama: 10–30V DC)
2X20Redundancy mode: 2-channel input, rated current per channel 20A (-25°C ~ 60 °C)
1X40Capacity expansion mode: 1-channel output, total rated current 40A (-25°C ~ 60 °C)
2320157Phoenix Contact global unique part number for ordering and identification
  1. Parâmetros de especificação principal
Categoria de parâmetroEspecificações detalhadas
Basic FeaturesRedundancy module / diode decoupling / 2-input 1-output / IP20 / Class III protection / UL 508 certified
Parâmetros Elétricos• Input Voltage: 10–30V DC (rated 12–24V DC)
• Rated Current: 2×20A (redundância) / 1×40A (capacity expansion)
• Max Current: 2×30A (-25°C~40°C) / 1×60A (-25°C~40°C)
• Power Loss: ≤10W @ 20A output
• Efficiency: >97%
Parâmetros Mecânicos• Dimensions: 50(C)×130(H)×125(D) milímetros
• Mounting: E 35 Trilho DIN (EM 60715)
• Weight: 0.75kg
Parâmetros Ambientais• Operating Temperature: -40°C ~ 70°C (2.5% derating per K above 60°C)
• Storage Temperature: -40°C ~ 85°C
• Humidity: ≤95% RH @ 25°C, sem condensação
• Protection Class: IP20
• MTBF: 40,000,000 horas (CEI 61709)
Connection Parameters• Input Terminals: M3 screw / 0.2–6mm² (solid) / 0.2–4mm² (stranded) / stripping length 7mm
• Output Terminals: M4 screw / 0.5–16mm² (solid/stranded) / stripping length 10mm
• Wire Gauge: Input AWG 12–10 / Output AWG 10–6
Safety CertificationsUL/C-UL Listed UL 508, UL 60950-1, ANSI/ISA-12.12.01 (Class I Div.2), ATEX, IECEx
  1. Lista de acessórios & Conteúdo do pacote

Standard Package: 1 pcs QUINT-DIODE/12-24DC/2X20/1X40 Module (2320157)

Supplied Documents: Installation manual, product certificate, PDF download link for technical datasheet

Acessórios opcionais:

DIN rail mounting adapter (por exemplo. UTA 107/30)

Terminal protective cover

Marker strip / marking system

  1. Competitor & Lista de substituição entre marcas
MarcaModeloParâmetros principaisReplace Compatibility
Phoenix Contact Upgrade Version2907719 (QUINT4-DIODE/12-24DC/2X20/1X40)Mesmas especificações, new generation QUINT4 series with optimized performanceTotalmente compatível, substituição direta
Schneider ElétricaABL8RPS2404024CCV / 2×20A / 1×40A / Diode redundancyFuncionalmente equivalente, slight difference in mounting dimensions
SiemensSITOP Redundancy Module 6EP1961-3BA2124CCV / 2×20A / Diode redundancyFuncionalmente equivalente, confirm installation space
WeidmüllerDRM 20-24DC/2×20/1×4024CCV / 2×20A / 1×40A / Diode redundancyDirect competitor with similar performance
ABBCM-MRD 24DC 4024CCV / 40UM / Diode redundancy moduleSimilar function, different input channel quantity possible
  1. Pontos-chave da seleção & Soluções Alternativas

5.1 Critérios Básicos de Seleção

✅ Voltage Matching: Confirm system voltage 12–24VDC, fluctuation range within 10–30VDC

✅ Current Matching:

Redundancy Mode: Single power supply rated current ≤20A, dual power parallel connection

Capacity Expansion Mode: Total load current ≤40A, dual power parallel for power upgrade

✅ Installation Space: Reserve 50mm width, 5mm gap on both sides, 15mm top clearance and 20mm bottom clearance for heat dissipation

✅ Environmental Conditions: Operating temperature ≤60°C (2.5% derating per K over temperature), humidity ≤95% non-condensing

5.2 Alternative Solution Decision Tree

Cenário de aplicaçãoModelo recomendadoRazão
Standard Redundancy Requirement2320157 (Original Version)Mature, stable and cost-effective
Latest Technology Requirement2907719 (QUINT4 Series)New generation, optimized performance and longer service life
Maior exigência atualQUINT-DIODE/48DC/2X20/1X40 (2320160)48VDC system with same current rating
Lower Current RequirementTRIO-DIODE/12-24DC/2X10/1X2010A/20A rating with lower cost
Active Redundancy RequirementQUINT S-ORING (2907752)Active switching, lower voltage drop and higher efficiency
  1. Selection Mnemonic (Seleção & Aplicativo)

QUINT Diode Redundancy Module Selection Mnemonic

12–24 DC for use, two inputs one output keep in view

20A stable for redundancy, 40A flexible for capacity boost

Derate above sixty centigrade, 2.5% per Kelvin degrade

Reserve mounting gap well, ensure heat dissipation as well

Old version 2320157, new version 2907719

Choose S-ORING for active redundancy, higher efficiency and more steady

  1. Key Application Scenarios
  2. Automação Industrial: Dual power redundancy for PLC control cabinets to ensure uninterrupted control system operation
  3. Controle de Processo: Power supply for critical process instruments in chemical, pharmaceutical and other industries to avoid production shutdown caused by power failure
  4. Centro de dados: Redundant power backup for servers and network equipment to guarantee data security
  5. Rail Transit: Dual power guarantee for on-board equipment and signal systems, adapting to harsh environments
  6. Energia Renovável: Redundant power supply for photovoltaic and wind power control systems to improve system availability

Complete Model List of Phoenix Contact Diode Redundancy Modules

Visão geral: Classified into 6 major series: QUINT4 / QUINT / TRIO2 / TRIO / UNO / STEP3, covering 5–48VDC voltage and 5–40A current specifications, including standard type / monitored type / coated type versions to meet different power and reliability requirements.

  1. QUINT4 Series (New Generation High Performance)
Número da peça.ModeloFaixa de tensãoClassificação atualRecursos principais
2907719QUINT4-DIODE/12-24DC/2X20/1X4012–24 VCC (10–30VDC)2×20A Redundancy / 1×40A Capacity ExpansionLatest QUINT4 platform, alta confiabilidade, MTBF>40 million hours
2907720QUINT4-DIODE/48DC/2X20/1X4048CCV (30–56VDC)2×20A Redundancy / 1×40A Capacity ExpansionCompatible with 48V system, fully interchangeable with classic QUINT
2907721QUINT4-DIODE/12-24DC/2X10/1X2012–24 VCC (10–30VDC)2×10A Redundancy / 1×20A Capacity ExpansionLow current version, space-saving and cost-effective
2907722QUINT4-DIODE/48DC/2X10/1X2048CCV (30–56VDC)2×10A Redundancy / 1×20A Capacity Expansion48V low current application, matches TRIO power supply
  1. QUINT Series (Classic High Performance)
Número da peça.ModeloFaixa de tensãoClassificação atualRecursos principais
2320157QUINT-DIODE/12-24DC/2X20/1X4012–24 VCC (10–30VDC)2×20A Redundancy / 1×40A Capacity ExpansionMost commonly used model, matched with QUINT 24V power supply
2320160QUINT-DIODE/48DC/2X20/1X4048CCV (30–56VDC)2×20A Redundancy / 1×40A Capacity ExpansionMatched with QUINT 48V power supply, industrial standard
2866585QUINT-DIODE/48DC/4048CCV (30–56VDC)1×40AWith protective coating, adequado para ambientes agressivos
2938963QUINT-DIODE/4012–24 VCC (10–30VDC)1×40ASimplified version, single-channel 40A output
2866584QUINT-DIODE/12-24DC/4012–24 VCC (10–30VDC)1×40AWith protective coating, single-channel output
  1. TRIO2 Series (Cost-Efficient High-Efficiency)
Número da peça.ModeloFaixa de tensãoClassificação atualRecursos principais
2907379TRIO2-DIODE/12-24DC/2X20/1X4012–24 VCC (10–30VDC)2×20A Redundancy / 1×40A Capacity ExpansionDesempenho de alto custo, matched with TRIO2 power supply
2907380TRIO2-DIODE/12-24DC/2X10/1X2012–24 VCC (10–30VDC)2×10A Redundancy / 1×20A Capacity ExpansionLow current version for light load
2907381TRIO2-DIODE/48DC/2X10/1X2048CCV (30–56VDC)2×10A Redundancy / 1×20A Capacity Expansion48V system, matched with TRIO2 48V power supply
2907382TRIO2-DIODE/48DC/2X20/1X4048CCV (30–56VDC)2×20A Redundancy / 1×40A Capacity Expansion48V high current, economic alternative solution
  1. TRIO Series (Basic Economy Type)
Número da peça.ModeloFaixa de tensãoClassificação atualRecursos principais
2866514TRIO-DIODE/12-24DC/2X10/1X2012–24 VCC (10–30VDC)2×10A Redundancy / 1×20A Capacity ExpansionWith function monitoring, first choice for basic applications
2866527TRIO-DIODE/48DC/2X10/1X2048CCV (30–56VDC)2×10A Redundancy / 1×20A Capacity Expansion48V with monitoring, matched with TRIO 48V power supply
2866515TRIO-DIODE/12-24DC/2X20/1X4012–24 VCC (10–30VDC)2×20A Redundancy / 1×40A Capacity ExpansionHigh current with monitoring, econômico
2866528TRIO-DIODE/48DC/2X20/1X4048CCV (30–56VDC)2×20A Redundancy / 1×40A Capacity Expansion48V high current with monitoring, general industrial use

 

  1. UNO Series (Ultra-Compact Miniature)
Número da peça.ModeloFaixa de tensãoClassificação atualRecursos principais
2905489UNO-DIODE/5-24DC/2X10/1X205–24 VCC (4.5–28VDC)2×10A Redundancy / 1×20A Capacity ExpansionUltra-compact design, matched with UNO miniature power supply
2905490UNO-DIODE/5-24DC/2X5/1X105–24 VCC (4.5–28VDC)2×5A Redundancy / 1×10A Capacity ExpansionMinimum current rating, suitable for embedded systems
  1. STEP3 Series (Entry-Level for Control Cabinet)
Número da peça.ModeloFaixa de tensãoClassificação atualRecursos principais
1283937STEP3-DIODE/5-24DC/2X5/1X10/PT5–24 VCC (4.5–28VDC)2×5A Redundancy / 1×10A Capacity ExpansionEntry-level price, matched with STEP3 basic power supply
1283938STEP3-DIODE/12-24DC/2X10/1X2012–24 VCC (10–30VDC)2×10A Redundancy / 1×20A Capacity ExpansionBasic high current type for simple redundancy demand
  1. Selection Mnemonic & Key Differentiation

7.1 Series Positioning Mnemonic

QUINT4: New flagship, alta confiabilidade, longa vida útil

QUINT: Modelo clássico, desempenho estável, wide application

TRIO2: New economy, econômico, matches new power supplies

TRIO: Modelo básico, with monitoring, baixo custo

UNO: Ultracompacto, miniaturized, embedded use

STEP3: Entry-level, preço baixo, basic application

7.2 Key Parameter Differentiation

ParâmetroPontos de seleção
Tensão12–24 VCC(10–30VDC): Most common in industry
48CCV(30–56VDC): High power / remote power supply
5–24 VCC(4.5–28VDC): Baixa tensão / hybrid system
Atual2×5A/1×10A: Light load
2×10A/1×20A: Medium load
2×20A/1×40A: Heavy load / power superposition
FunçãoWith monitoring: Fault alarm for easy maintenance
With coating: Adapt to humid / dusty environment
Tipo padrão: General scenarios with high cost performance
  1. Application Scenario Matching Guide
Cenário de aplicaçãoSérie recomendadaModelo típico
Industrial Automation PLC CabinetQUINT / QUINT42320157(2907719), 2320160(2907720)
Process Control Critical EquipmentQUINT4 (Coated Version)2907719, 2866585
Small Control Cabinet / Embedded SystemUNO / STEP32905489, 1283937
Cost-Effective ProjectsTRIO2 / TRIO2907379, 2866514
48V System (Telecom / Centro de dados)QUINT4 / QUINT2907720, 2320160

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado