SMC SY3220-5G-C4 Solenoid Valve - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

SMC SY3220-5G-C4 Solenoid Valve - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

SMC SY3220-5G-C4 Solenoid Valve

SMC SY3220-5G-C4 5/2-way Single-coil Pilot-operated Solenoid Valve Product Positioning SMC SY3000 series miniature 5/2-way single-coil pilot-operated solenoid valve. Designed specifically for high-frequency switching, suitable for small cylinder control. Widely applied in pneumatic automation, electronic equipment, packaging machinery and other industries. Definição de código de modelo (SY3220-5G-C4) Segment Code Description Optional Configuration SY SY SMC SY series pilot-operated ...

  • Detalhes do produto

SMC SY3220-5G-C4 5/2-way Single-coil Pilot-operated Solenoid Valve

  1. Posicionamento do produto

SMC SY3000 series miniature 5/2-way single-coil pilot-operated solenoid valve.

Designed specifically for high-frequency switching, suitable for small cylinder control.

Widely applied in pneumatic automation, electronic equipment, packaging machinery and other industries.

  1. Definição de código de modelo (SY3220-5G-C4)
SegmentoCódigoDescriçãoOptional Configuration
SYSYSMC SY series pilot-operated 5-way solenoid valveFixo
33Size code: 3000 series miniature body (width 10mm)3=Mini, 5=Medium, 7=Large, 9=Extra Large
22Function type: 5/2-way2=5/2-way, 3=5/3-way
2020Estrutura: Single-coil + manifold base mounting20=Single-coil, 40=Dual-coil
55Tensão da bobina: CC24V4=AC110V, 5=DC24V, 6=AC220V
GGWiring type: Direct outlet type (lead type, cable length 300mm)G=Direct outlet, LZ=Socket with indicator, LD=Socket with indicator + diode
C4C4Port size: φ4mm push-in fittingC4=φ4mm, C6=φ6mm, M5=M5 thread
  1. Main Technical Specifications
CategoriaParâmetroDetalhes
Basic CharacteristicsValve Type5/2-way, Single-coil, Internal pilot, Elastic seal
Working MediumCompressed air (Lubrication optional; ISO VG32 lubricant recommended)
Tipo de montagemManifold base mounting
Pressure RatingsOperating Pressure0.15~0.7 MPa
Pressão de prova1.0 MPa
Guaranteed Withstand Pressure1.5 MPa
Electrical RatingsTensão nominalCC24V
Voltage Fluctuation±10%
Consumo de energiaPadrão: 2.5C; Energy-saving: 0.1C (with power-saving circuit)
Classe de ProteçãoIP40
Flow CharacteristicsEffective Cross-sectional Area1.1 mm²
Max Flow Rate196 NL/min @ 0.5MPa
Environmental RatingsAmbient / Medium Temperature-5℃~+50℃ (Non-freezing)
Umidade35%~85%RH
Physical ParametersValve Body Width10milímetros (SY3000 series standard width)
PesoAprox.. 60g (including coil)
Piping MethodFront piping (push-in fitting)
  1. Standard Accessories List
Nome do acessórioEspecificaçãoQuantidadeObservações
Solenoid Valve Main BodySY3220-5G-C41 pcIncludes coil, valve body, pilot valve
Outlet Cable300milímetros, 2-essencial1 pcStandard for G-type direct outlet
Mounting GasketFor SY3000 series1 pcManifold sealing
Parafusos de montagemM3×8mm2 peçasFix valve to manifold
Instruction ManualEletrônico / Paper Version1 copyIncluding installation, manutenção & solução de problemas
  1. SY3220 Series Full Model List (Common Types)
    ModeloTensãoWiring TypeTamanho da portaCaracterísticas
    SY3220-5G-C4CC24VDirect outletφ4mmTipo padrão, high-frequency switching
    SY3220-5G-C6CC24VDirect outletφ6mmHigh flow type
    SY3220-5LZ-C4CC24VSocket with indicatorφ4mmVisible status, easy diagnosis
    SY3220-5LD-C4CC24VSocket with indicator + diodeφ4mmReverse polarity protection, proteção de circuito
    SY3220-4G-C4AC110VDirect outletφ4mmCompatible with AC110V control system
    SY3220-6G-C4AC220VDirect outletφ4mmCompatible with AC220V control system
    SY3220-5G-M5CC24VDirect outletM5 threadThread connection type
    SY3220-5GUE-C4CC24VDirect outlet with indicator + proteção contra surtosφ4mmAdvanced protection type

    Compatible Manifold Models

Manifold ModelNumber of StationsTamanho da portaCaracterísticas
SS5Y3-01-011-stationC4/C6/M51-station manifold
SS5Y3-02-022-stationC4/C6/M52-station manifold
SS5Y3-05-055-stationC4/C6/M55-station manifold
SS5Y3-10-1010-stationC4/C6/M510-station manifold
SS5Y3-20-2020-stationC4/C6/M520-station manifold
SS5Y3-05-05D5-stationC4/C6/M5With DIN rail mounting
  1. Competitor & Tabela de substituição entre marcas
MarcaModeloCorrespondência de especificaçõesDiferença CentralIntercambialidade
SMCSY3220-5G-C4100%Original genuine, qualidade confiável, preço mais alto-
Airtac4V210-0690%30% Menor preço, slightly lower flowSame mounting holes, direct interchangeable
MindmanMVSC-220-4E190%Similar response speed, preço moderadoCompatible mounting dimensions
FestoVUVS-L20-M52-AD-G14-F885%Preço mais alto, Proteção IP65Requires adapter plate
CKD4F210-0885%Japanese quality, preço moderadoSame mounting holes
  1. Diretrizes de seleção & Replacement Rules

Dicas de seleção

Three key factors for SY3220 selection: tensão, wiring and port size;

5 stands for 24V, G for direct wire outlet;

C4 for Φ4 tube, C6 for Φ6 tube;

20 for single-coil, 40 for dual-coil match;

10mm miniature body, manifold mounting saves space.

Árvore de decisão de seleção

  1. Tensão de controle: Choose 5 for DC24V, 4 for AC110V, 6 for AC220V
  2. Wiring Type: Fixed installation → G (direct outlet); Frequent replacement → LZ/LD (socket type)
  3. Tamanho da porta: Low flow → C4 (Φ4mm); High flow → C6 (Φ6mm)
  4. Modo de controle: Single-acting → 20 single-coil; Double-acting → 40 dual-coil
  5. Montagem: Manifold mounting → Standard type; Independent mounting → Model with F1 bracket

Recomendações de substituição

Budget limited: Choose Airtac 4V210-06, 30% cost down, sufficient performance for most working conditions

Frequent maintenance: Select LZ/LD socket type for fast coil replacement and less downtime

Higher flow required: Upgrade to SY5220 series (medium body, effective area 2.8mm²)

Harsh environment: Choose UE suffix model (with indicator + proteção contra surtos) for higher reliability

  1. Campos de aplicação típicos
  2. Electronic Equipment: Small cylinder drive, automatic assembly line, PCB conveying & posicionamento
  3. Máquinas de embalagem: Label attaching, film tension control, packaging sealing cylinder
  4. Equipamento Médico: Pneumatic control of analytical instruments, sample conveying mechanism
  5. Automation Production Line: Jig & fixture positioning, small manipulator joint control
  6. Processamento de Alimentos: Small pneumatic actuator, sorting mechanism control
  7. Operação chave & Pontos de Manutenção
  8. Antes da instalação: Ensure medium cleanliness (5μm filter recommended) to prevent seal damage by impurities
  9. Direção de instalação: Follow the flow arrow on valve body; reverse installation is prohibited
  10. Manifold Mounting: Use sealing gasket, tighten screws evenly (torque 0.5~0.7N·m)
  11. Ciclo de Manutenção: Inspect seals every 6 meses; replace O-rings annually
  12. Solução de problemas: No action → Check in sequence: Voltage → Air pressure → Coil → Pilot valve

SMC SY Series Solenoid Valve Complete Model List & Guia de seleção

  1. Series Classification & Naming Rule Overview

1.1 Series Specification Classification (by Body Size & Flow)

Código da sérieBody WidthEffective AreaMax FlowSuitable CylinderAplicação Típica
SY300010milímetros1.1m㎡196NL/minφ6~φ20Mini cylinder, precision control
SY500015milímetros2.8m㎡470NL/minφ25~φ40Small cylinder, general automation
SY700020milímetros5.2m㎡860NL/minφ50~φ63Medium cylinder, production line
SY900030milímetros11.0m㎡1780NL/minφ80~φ125Large cylinder, high flow system

1.2 Regra de nomenclatura completa (Exemplo: SY3220-5G-C4)

SegmentoCódigoSignificadoOptional Configuration
SYSYSeries prefixFixo
3/5/7/93Size code3=SY3000, 5=SY5000, 7=SY7000, 9=SY9000
23º dia do mês2Código de função2=5/2-way, 3=5/3-way
20/40/30/31/3220Modo de controle20=Single-coil, 40=Dual-coil, 30=Closed center, 31=Exhaust center, 32=Pressure center
2005/4/65Tensão da bobina4=AC110V, 5=DC24V, 6=AC220V
G/LZ/LD/UEGWiring typeG=Direct outlet, LZ=Socket with indicator, LD=Socket with indicator+diode, UE=Indicator+surge protection
C4/C6/M5C4Port sizeC4=φ4mm push-in, C6=φ6mm push-in, M5=M5 thread
-P-PCertificaçãoQ=CE certified (opcional)
  1. Full Standard Model List By Series

2.1 SY3000 Series (Mini, 10mm Width)

5/2-way Single-coil (Tipo 20)

ModeloTensãoWiring TypeTamanho da portaCaracterísticas
SY3220-4G-C4AC110VDirect outletφ4mmTipo padrão
SY3220-4G-C6AC110VDirect outletφ6mmAlto fluxo
SY3220-4LZ-C4AC110VSocket with indicatorφ4mmStatus visible
SY3220-5G-C4CC24VDirect outletφ4mmMost commonly used
SY3220-5G-C6CC24VDirect outletφ6mmHigh flow common
SY3220-5LZ-C4CC24VSocket with indicatorφ4mmStatus visible
SY3220-5LD-C4CC24VSocket with indicator+diodeφ4mmReverse polarity protection
SY3220-5G-M5CC24VDirect outletM5 threadThread connection
SY3220-5GUE-C4CC24VDirect outlet+indicator+surge protectionφ4mmProteção avançada
SY3220-6G-C4AC220VDirect outletφ4mmAC220V system compatible

5/2-way Dual-coil (Tipo 40)

ModeloTensãoWiring TypeTamanho da porta
SY3240-5G-C4CC24VDirect outletφ4mm
SY3240-5LZ-C4CC24VSocket with indicatorφ4mm
SY3240-5G-C6CC24VDirect outletφ6mm

5/3-way (30/31/32 Tipo)

ModeloTipo de controleTensãoWiring TypeTamanho da porta
SY3330-5G-C4Closed CenterCC24VDirect outletφ4mm
SY3331-5G-C4Exhaust CenterCC24VDirect outletφ4mm
SY3332-5G-C4Pressure CenterCC24VDirect outletφ4mm

2.2 SY5000 Series (Médio, 15mm Width)

5/2-way Single-coil (Tipo 20)

ModeloTensãoWiring TypeTamanho da porta
SY5220-5G-C4CC24VDirect outletφ4mm
SY5220-5G-C6CC24VDirect outletφ6mm
SY5220-5LZ-C6CC24VSocket with indicatorφ6mm
SY5220-5LD-C6CC24VSocket with indicator+diodeφ6mm
SY5220-5G-M5CC24VDirect outletM5 thread

5/2-way Dual-coil (Tipo 40)

ModeloTensãoWiring TypeTamanho da porta
SY5240-5G-C6CC24VDirect outletφ6mm
SY5240-5LZ-C6CC24VSocket with indicatorφ6mm
SY5240-5LD-C6CC24VSocket with indicator+diodeφ6mm

5/3-way (30/31/32 Tipo)

ModeloTipo de controleTensãoWiring TypeTamanho da porta
SY5330-5G-C6Closed CenterCC24VDirect outletφ6mm
SY5331-5G-C6Exhaust CenterCC24VDirect outletφ6mm
SY5332-5G-C6Pressure CenterCC24VDirect outletφ6mm

2.3 SY7000 Series (Grande, 20mm Width)

ModeloFunçãoTipo de controleTensãoWiring TypeTamanho da porta
SY7220-5G-C65/2-waySingle-coilCC24VDirect outletφ6mm
SY7240-5G-C65/2-wayDual-coilCC24VDirect outletφ6mm
SY7330-5G-C65/3-wayClosed CenterCC24VDirect outletφ6mm
SY7331-5G-C65/3-wayExhaust CenterCC24VDirect outletφ6mm
SY7332-5G-C65/3-wayPressure CenterCC24VDirect outletφ6mm

2.4 SY9000 Series (Extra Large, 30mm Width)

ModeloFunçãoTipo de controleTensãoWiring TypeTamanho da porta
SY9220-5G-C65/2-waySingle-coilCC24VDirect outletφ6mm
SY9240-5G-C65/2-wayDual-coilCC24VDirect outletφ6mm
SY9330-5G-C65/3-wayClosed CenterCC24VDirect outletφ6mm
SY9331-5G-C65/3-wayExhaust CenterCC24VDirect outletφ6mm
SY9332-5G-C65/3-wayPressure CenterCC24VDirect outletφ6mm
  1. Special Specification Models (Common Derivatives)

3.1 With Mounting Bracket (Suffix F1)

For independent mounting, only available for 5/2-way single-coil models

SY3220-5G-C4-F1

SY5220-5G-C6-F1

SY7220-5G-C6-F1

3.2 CE Certified Model (Suffix -Q)

Compliant with EMC & Low Voltage Directive, widely used for European export

SY3220-5G-C4-Q

SY5220-5G-C6-Q

SY7220-5G-C6-Q

3.3 External Pilot Type (Suffix -P)

Suitable for vacuum or low-pressure environment (0~0.7MPa)

SY3220-5G-C4-P

SY5220-5G-C6-P

3.4 Clean Room Version (Suffix -C)

Suitable for Class 100 clean environment

SY3220-5G-C4-C

SY5220-5G-C6-C

  1. Compatible Manifold Models (Universal for All Series)
Manifold ModelSérie aplicávelNumber of StationsTamanho da portaCaracterísticas
SS5Y3-01-01SY30001-stationC4/C6/M51-station manifold
SS5Y3-05-05SY30005-stationC4/C6/M55-station manifold
SS5Y5-05-05SY50005-stationC4/C6/M55-station manifold
SS5Y7-05-05SY70005-stationC4/C6/M55-station manifold
SS5Y3-10-10DSY300010-stationC4/C6/M510-station with DIN rail
SS5Y5-20-20SY500020-stationC4/C6/M520-station manifold
  1. Selection Mnemonic

Five key points for SY selection: série, função, tensão;

3=Mini,5=Medium,7=Large,9=Extra Large;

2=5/2-way,3=5/3-way remember clearly;

20=Single-coil,40=Dual-coil;

30=Closed,31=Exhaust,32=Pressure center;

5=24V,G=direct wire outlet;

C4 for Φ4,C6 for Φ6 tube;

Manifold mounting saves space, add F1 for standalone installation;

Add -Q for CE, add -P for external pilot.

  1. Core Selection Decision Tree
  2. Flow Demand: Mini cylinder → SY3000; Small → SY5000; Medium → SY7000; Large → SY9000
  3. Modo de controle: Single-acting → Single-coil(20); Reciprocating → Dual-coil(40); Mid-stop → 5/3-way(30/31/32)
  4. Voltage Match: DC24V→5; AC110V→4; AC220V→6
  5. Wiring Preference: Fixed installation→G; Frequent replacement→LZ/LD
  6. Tamanho da porta: Low flow→C4; High flow→C6; Thread→M5
  7. Montagem: Manifold→Standard; Independent→Model with F1 bracke
  8. Cross-Series Replacement Reference
Modelo originalSubstituição de atualizaçãoDowngrade ReplacementReplacement Reason
SY3220-5G-C4SY5220-5G-C6-Upgrade when flow insufficient
SY5220-5G-C6SY7220-5G-C6SY3220-5G-C6Cylinder upsize / downsize
SY7220-5G-C6SY9220-5G-C6SY5220-5G-C6High flow demand / cost optimization

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado