Schneider ATV310HU75N4E Variable Frequency Drive - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Schneider ATV310HU75N4E Variable Frequency Drive - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

Schneider ATV310HU75N4E Variable Frequency Drive

Model Code Definition Code Segment Description ATV Base series code: Altivar Variable Speed Drive, Schneider’s VFD product line 310 Designação de série: Economy Altivar 310 série, cost-effective drives for general industrial applications H Load rating: Serviço Pesado, designed for continuous heavy-load operation with higher rated output current U75 Power rating: 7.5 kW (10 HP), matched for ...

  • Detalhes do produto

Definição de código de modelo

Segmento de códigoDescrição
quadricicloBase series code: Altivar Variable Speed Drive, Schneider’s VFD product line
310Designação de série: Economy Altivar 310 série, cost-effective drives for general industrial applications
HLoad rating: Serviço Pesado, designed for continuous heavy-load operation with higher rated output current
U75Power rating: 7.5 kW (10 HP), matched for 7.5kW three-phase asynchronous motors
N4Power supply specification: 3-phase 380–460 V AC, 50/60 Hz; permissible voltage variation: -15% ~ +10%
EConfiguration option: Standard version without built-in EMC filter; models with integrated filter end with suffix A
  1. Especificações Técnicas Principais

2.1 Especificações Elétricas

ItemValorObservação
Potência nominal7.5kW(10HP) Serviço Pesado / 11kW(15HP) Dever normalDual rating design for diverse working conditions
Tensão de entrada nominal3-phase 380–460 V ACOperating range:323–528 V AC
Corrente de saída nominal17 UM (alta definição) / 24 UM (DE)Full rating up to 55°C; 2.2% derating per °C above 55°C up to 60°C
Faixa de frequência de saída0.1~500 HzMinimum 0.1Hz under sensorless vector control
Modo de controleControle vetorial sem sensor / Controle V/FAutomatic torque boost for various asynchronous motors
Instant Overload Torque170~200% of rated torqueSustain for 2 seconds for shock load applications
Unidade de Frenagem IntegradaEquipado de sériePre-installed on models ≥7.5kW for fast braking requirements
Porta de comunicaçãoRS485 (Modbus RTU)RJ45 terminal on front panel for remote monitoring
Classe de ProteçãoIP20Cabinet indoor mounting only

2.2 Mecânico & Especificações Ambientais

ItemValorObservação
Dimensão Geral(L×A×P)210×380×170 mmCompact footprint to save cabinet space
Tipo de montagemParede / Montagem em painelVertical installation to secure unobstructed cooling airflow
Temperatura operacional-10℃ ~ +55℃ (full rating)2.2% power derating per ℃ between 55℃~60℃
Temperatura de armazenamento-25℃ ~ +70 ℃Keep away from damp and corrosive gas atmosphere
Umidade Ambiente5%~95% (sem condensação)Dehumidifier recommended inside control cabinet
Método de resfriamentoForced air cooling with built-in fanFan with thermal protection and auto fault alarm
Peso líquidoApprox.7.8 kgEasy transportation and field installation

2.3 Certificação & Conformidade

CertificaçãoPadrão AplicávelObservação
CEEM 61800-5-1 / EM 61000-6-2/4Segurança & EMC compliance standard
UL RecognizedUL 508CNorth American standard for industrial control equipment
Eco ComplianceEU RoHS / RoHS da ChinaRestriction of hazardous substances
HS Customs Code85044099Used for customs clearance in international trade
  1. Full Heavy-Duty Model List of ATV310 Series
Número da peça.Descrição do modeloClassificação de potênciaRecurso EspecialAplicação Típica
ATV310HU75N4E7.5kW Heavy Duty7.5kW /10HPWithout built-in EMC filterGeneral industrial fans & bombas
ATV310HU75N4A7.5kW Heavy Duty7.5kW /10HPWith built-in EMC filterSites with strict EMC requirements
ATV310H037N4E0.37kW Heavy Duty0.37kW /0.5HPSem filtro EMCMáquinas pequenas, correias transportadoras
ATV310H075N4E0.75kW Heavy Duty0.75kW /1HPSem filtro EMCMini fans & bombas de água
ATV310H15N4E1.5kW Heavy Duty1.5kW /2HPSem filtro EMCEmbalagem & máquinas têxteis
ATV310H22N4E2.2kW Heavy Duty2.2kW /3HPSem filtro EMCEquipamento de manuseio de materiais, compressores
ATV310H30N4E3.0kW Heavy Duty3.0kW /4HPSem filtro EMCAgitators, pequenas bombas de água
ATV310H40N4E4.0kW Heavy Duty4.0kW /5.5HPSem filtro EMCTorres de resfriamento, sistemas de ventilação
ATV310H55N4E5.5kW Heavy Duty5.5kW /7.5HPSem filtro EMCMedium-sized fans & process pumps
ATV310HD11N4E11kW Heavy Duty11kW /15HPSem filtro EMCCompressores grandes, industrial pumps
  1. Referência Cruzada: Internal Upgrade & Competitor Equivalent

4.1 Schneider Internal Replacement

Modelo ObsoletoModelo de substituiçãoVantagens de atualização
ATV303HU75N4ATV310HU75N4E/AWider operating temp (-10~55℃), unidade de frenagem integrada, anti-corrosion coating, more compact dimension
ATV310HU75N4EATV310HU75N4AAdd integrated EMC filter to satisfy stricter EMC regulations

4.2 Cross-brand Alternative Comparison

Modelo SchneiderEquivalente SiemensABB EquivalentKey Differentiation
ATV310HU75N4EMM440-7.5kWACS510-7.5kWSchneider: Dual power rating, full capacity @55℃, unidade de freio embutida, cost competitive
150% overload for 3s160% overload for 1minSiemens: Higher vector control precision; ABB: Richer communication options
  1. Escopo de aplicação & Casos Industriais

5.1 Aplicativos recomendados

  1. Industrial Pumps & Fãs: Sistemas HVAC, raw & wastewater treatment plants; 30~50% energy saving achievable
  2. Manuseio de materiais: Transportadores, guinchos, cranes for smooth soft start and variable speed regulation
  3. Textile Equipment: Winding machines, looms, impressão & dyeing machines for constant tension control
  4. Máquinas de embalagem: Enchimento, labeling and sealing equipment to boost production efficiency & product quality
  5. Compressores: Ar & refrigeration compressors; soft start reduces grid surge and extends motor service life
  6. Equipamento de mistura: Chemical reactors & food blenders for mixing of fluids with variable viscosity

5.2 Aplicativos não recomendados

  1. Precision speed control for synchronous motors: Select ATV340 series with encoder-feedback vector drive
  2. High altitude installation (>1000eu): Mandatory power derating by 1% per additional 100m elevation
  3. Corrosive gas environment: Add external anti-corrosion enclosure or specify ATV320 anti-corrosion variant
  4. IP rating higher than IP20: Choose ATV320 IP54 protected models

5.3 Casos de aplicação típicos

Case1: Aeration System for Municipal Wastewater Plant

Aplicativo: Variable speed control of 7.5kW submersible aerator based on real-time dissolved oxygen value

Original Issue: Direct-on-line start leads to short motor lifespan, high power consumption and severe grid disturbance

Solução: Install ATV310HU75N4E for soft start; 40% power saving, double motor service life and reduced maintenance cost

Case2: Textile Spool Winding Machine

Aplicativo: Constant tension control for uniform yarn winding

Original Issue: Big tension fluctuation causes high yarn breakage rate and unstable finished quality

Solução: Adopt sensorless vector control to adjust output torque dynamically; tension tolerance controlled within ±5% and 15% improvement on finished product yield

  1. Diretrizes de seleção & Regras de referência rápida

Regras de seleção rápida

  1. Code Identification: ATV310=core series; H=Heavy Duty; U75=7.5kW; N4=3-phase 380V; E=No EMC filter
  2. Key Specs Recap: 17Uma corrente nominal, 170~200% overload torque, integrated brake unit, Modbus RTU communication
  3. Upgrade Option: Suffix A = built-in EMC filter; high-performance demand → ATV340 series
  4. Application Rule: Continuous heavy load → H version; light load → D version; strict EMC → A suffix model
  5. Air Shipment & CE Compliance Specification

7.1 Air Transport Regulation

Lithium Battery Check: No built-in lithium cells, classified as non-restricted cargo without special air shipping marks

Padrão de envio: Complies with IATA DGR Class9, allowed for general cargo transportation

Embalagem: Original factory carton preferred; anti-shock foam padding recommended to avoid transit damage

7.2 CE Certification Details

Applied Standards: EM 61800-5-1(Segurança), EM 61000-6-2(Immunity), EM 61000-6-4(Emission)

DOC Download: EU Declaration of Conformity available on Schneider official website (Doc No.:ATV310_CE_DOC.pdf)

Valid Territory: All EU member states and regions recognizing CE marking

  1. On-site Troubleshooting Guide
Código de falha & DescriçãoCausa raizCorrective Action
CF Overcurrent Fault1. Motor winding short or earth fault1. Insulate motor cable & enrolamento
2. Too short acceleration ramp2. Prolongue o tempo de aceleração (Parâmetro 202)
3. Excessive mechanical overload3. Reduce load or upgrade to higher power drive
OH Overheat Fault1. Excessive ambient temperature1. Improve cabinet cooling & reduce surrounding temp
2. Failed cooling fan2. Inspect/replace faulty fan
3. Poor cabinet ventilation3. Reserve ≥10cm clearance around drive
PF Power Supply Fault1. Tensão de entrada anormal (phase loss/low voltage)1. Measure three-phase incoming voltage & sequência de fase
2. Severe mains fluctuation2. Add line reactor or stabilizer
3. Loose input terminal wiring3. Retighten terminals at 2.5~3.0 N·m torque
SC Output Short-circuit1. Short on output terminals1. Check output terminal insulation
2. Damaged motor cable insulation2. Replace defective power cable
3. Internal drive hardware damage3. Contact Schneider after-sales service
FL Underload Alarm1. Disconnection between motor and mechanical load1. Check mechanical coupling between motor & carregar
2. Insufficient load2. Adjust underload protection threshold (Parameter404)
3. Incorrect parameter setting3. Verify entered motor nameplate parameters
  1. Instalação & Wiring Specification for Field Use

9.1 Requisitos de instalação

  1. Posição de montagem: Middle/upper zone inside control cabinet, avoid dusty bottom area; vertical mounting only
  2. Liberação: ≥10cm left/right spacing, ≥15cm top/bottom spacing for smooth heat dissipation
  3. Earthing Rule: Reliable PE connection; earth resistance ≤4Ω; ground conductor ≥6mm² copper cable

9.2 Main Power Circuit Wiring

Marcação de terminaisDefiniçãoPadrão de fiação
L1/L2/L33-phase AC Input≥6mm² copper cable, torque de aperto:2.5~3.0 N·m
U/V/WMotor Output Terminals≥6mm² copper cable, torque de aperto:2.5~3.0 N·m
PA/PBExternal Brake Resistor Connection(Opcional)≥4mm² copper cable, torque de aperto:2.0~2.5 N·m
Educação FísicaTerra Protetora≥6mm² copper cable, torque de aperto:3.0~3.5 N·m

9.3 Fiação do Circuito de Controle

  1. Digital Input DI1~DI6: PNP/NPN switchable for limit switches & sensor signals
  2. Analog Input AI1: 0~10V /4~20mA for speed reference or process feedback signal
  3. Analog Output AO1:0~10V/4~20mA for output frequency, current or torque monitoring
  4. Comunicação: RS485 Modbus RTU for data exchange with PLC & IHM