Inversor Schneider ATV71HU55N4Z - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Inversor Schneider ATV71HU55N4Z - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

inversor solar/elétrica/

Inversor Schneider ATV71HU55N4Z

Segmento de modeloSignificado
ATV71Altivar 71 series high-performance inverter
HStandard coating, Classe de proteção IP20, wall-mounted installation
U55Rated for 5.5kW motor power
N4380-480V three-phase power supply, 50/60Hz
ZFiltro EMC integrado, no graphic terminal, with Modbus and CANopen communication

  • Detalhes do produto

Visão geral: The ATV71HU55N4Z is a general-purpose inverter of Schneider‘s Altivar 71 série, with a rating of 5.5kW/7.5HP, compatible with 380-480V three-phase power supply. It features a built-in EMC filter and Modbus/CANopen communication, without a graphic terminal, and is suitable for constant torque loads. This model has been discontinued, and the ATV340 or ATV930 series are recommended as replacements.

  1. Interpretação completa do modelo
Segmento de modeloSignificado
ATV71Altivar 71 series high-performance inverter
HStandard coating, Classe de proteção IP20, wall-mounted installation
U55Rated for 5.5kW motor power
N4380-480V three-phase power supply, 50/60Hz
ZFiltro EMC integrado, no graphic terminal, with Modbus and CANopen communication
  1. Parâmetros técnicos principais
Item de parâmetroValor
Potência nominal5.5kW (7.5HP)
Tensão de entrada380-480V three-phase, allowable fluctuation -15%~+10%
Corrente de saída14.3UM (400V), 17UM (480V), 20.3UM (380V)
Modos de controleControle V/f, sensorless flux vector control, closed-loop vector control (encoder required)
Interfaces de comunicaçãoBuilt-in Modbus and CANopen, supports various expansion cards (Profibus DP, DeviceNet, etc.)
Funções IntegradasStandard STO safety function (ISO 13849 PL e), PID regulator, brake control, over 150 built-in functions
EMC ClassFiltro EMC Classe A integrado, compatível com EN 55011 padrão
Classe de ProteçãoIP20 (external cabinet protection required)
Dimensões & PesoAprox.. 210*380*190milímetros, aprox.. 8kg
  1. Recursos do produto & Vantagens
  2. High Dynamic Performance: Achieves 100% rated torque at zero speed (150% torque nominal) output under closed-loop vector control, suitable for high-demand scenarios such as hoisting and lifting.
  3. Comprehensive Safety Integration: Standard STO (Torque seguro desativado) função, no additional modules required for safety circuit construction.
  4. Flexible Communication Expansion: Plug-in communication cards compatible with mainstream industrial fieldbuses, enabling seamless interconnection with Siemens, Rockwell, Omron PLCs.
  5. Robust and Durable Design: Standard coating for resistance to harsh industrial environments, with comprehensive protection mechanisms for over-temperature, over-voltage, over-load, etc..
  6. Operação fácil & Manutenção: Optional graphic terminal, “Easy Startmenu, parameter protection, and intuitive fault diagnosis.
  7. Cenários típicos de aplicação

The ATV71 series is designed exclusively for constant torque loads. Typical applications of ATV71HU55N4Z include:

Hoisting and lifting equipment (crane, elevator, winch)

Material conveying systems (belt conveyor, chain conveyor)

Máquinas de embalagem, máquinas para trabalhar madeira, wood-based panel equipment

Process control equipment, misturadores, compressors and other constant torque loads

Start-up and speed control of high-inertia loads

  1. Discontinuation & Soluções de substituição

The ATV71 series has been discontinued, and Schneider officially recommends the following replacement paths:

5.1 Schneider Original Replacements

Primeira escolha: ATV340U55N4 (5.5kW, 380-480V, built-in EMC, Modbus/CANopen)

Heavy-Duty/Complex Applications: ATV930U55N4 (higher performance and richer functions)

Key Replacement Notes: Match power, tensão, modo de controle, communication requirements, safety functions and installation method.

5.2 Cross-Brand Replacement Recommendations

MarcaModelo recomendadoPrincipais pontos de correspondência
SiemensMM440-5.5kW/380-480VConstant torque control, built-in EMC, Modbus
ABBACS550-01-12A6-45.5kW, IP20, filtro EMC integrado
MitsubishiFR-A840-00122-2-605.5kW, 380-480V, controle vetorial
RockwellPowerFlex 525-5.5kWBuilt-in EMC, multiple communication protocols
  1. Seleção & Notas de substituição
  2. Correspondência de tipo de carga: Confirm the load is constant torque; for variable torque loads (ventiladores/bombas de água), economical series such as ATV610 are recommended.
  3. Compatibilidade de acessórios: Original ATV71 I/O expansion cards, encoder interface cards, etc., may need to be replaced with models adapted to the new series.
  4. Migração de parâmetros: Use Schneider’s parameter conversion tool to ensure correct migration of key parameters (por exemplo, acceleration/deceleration time, torque limit, PID parameters).
  5. Funções de segurança: The STO function of the new series needs to be reconfigured to meet the safety class requirements of the original system.
  6. Espaço de instalação: The dimensions of ATV340/ATV930 are slightly different from ATV71; confirm the installation space is compatible.

Schneider ATV71HU55N4Z Replacement Models

Visão geral: The ATV340U55N4 (general/economical) is the first choice for original factory replacement, and ATV930U55N4 (high-performance/full-function) is for heavy-duty/complex applications; cross-brand options include 5.5kW models of the same specification such as Siemens MM440, ABB ACS550, Mitsubishi FR-A840, and Rockwell PowerFlex 525.

  1. Official Original Factory Replacement Solutions (Schneider Recommended)

The ATV71 series has been discontinued, and Schneider officially provides two core replacement paths:

1.1 Substituição padrão (Primeira escolha): ATV340U55N4 (Altivar Machine Series)

Item de parâmetroATV71HU55N4ZATV340U55N4Compatibilidade
Power/Voltage5.5kW/380-480V three-phase5.5kW/380-480V three-phase100%
Modos de controleV/f, vetor sem sensor, closed-loop vectorV/f, vetor sem sensor, closed-loop vector (standard encoder interface)100%
Interfaces de comunicaçãoBuilt-in Modbus, CANopenBuilt-in Modbus, CANopen, optional EtherNet/IPAtualizado
EMC FilterBuilt-in Class ABuilt-in Class A100%
Funções de segurançaSTO (PL e)STO (PL e) + optional SS1Atualizado
Classe de ProteçãoIP20IP20 (IP42 with optional cover)100%
Dimensões & Peso210*380*190mm/8kg200*360*180mm/7.5kgCompatível
VantagensMature and stableMais compacto, energy-efficient, highly integrated, econômico

Cenários Aplicáveis: Constant torque loads such as general machinery, material conveying, and packaging equipment, pursuing a balance between cost performance and functions.

1.2 High-Performance Replacement: ATV930U55N4 (Altivar Process Series)

Item de parâmetroATV71HU55N4ZATV930U55N4Compatibilidade
Power/Voltage5.5kW/380-480V three-phase5.5kW/380-480V three-phase100%
Modos de controleBasic vector controlAdvanced vector control + synchronous motor control + servo functionsAtualizado
Interfaces de comunicaçãoBasic communicationBuilt-in Modbus, CANopen, optional EtherNet/IP, ProfinetFully Upgraded
Capacidade de ExpansãoLimited expansionSupports more I/O, safety and communication expansion modulesAtualizado
Funções de segurançaSTOSTO+SS1+SLS+SBC (complete safety package)Fully Upgraded
Classe de ProteçãoIP20IP20/IP21 (opcional)Aprimorado
Dimensões & Peso210*380*190mm/8kg220*400*200mm/9kgCompatível
VantagensMature and stableIndústria 4.0 integration, advanced diagnosis, predictive maintenance

Cenários Aplicáveis: High-demand applications such as hoisting, lifting and high-precision positioning, requiring advanced safety functions and communication capabilities.

1.3 Substituições de aplicações especiais

Fan/Water Pump Applications: ATV610U55N4 (Altivar Process Series, otimizado para torque variável, higher energy efficiency)

Explosion-Proof Environment: ATV340U55N4 + explosion-proof enclosure (certification required)

Ultra-Compact Installation: ATV320U55N4 (design miniaturizado, simplified function version)

  1. Cross-Brand Replacement Model Recommendations (5.5kW/380-480V, Same Specification)
MarcaModelo recomendadoCore Matching PointsObservações
SiemensMM440-5.5kW/380-480V (6SE6440-2UD25-5CA1)Constant torque control, built-in EMC, Modbus communicationClassic general-purpose model with sufficient spare parts
ABBACS550-01-12A6-45.5kW, IP20, filtro EMC integradoSuitable for harsh environments with strong overload capacity
MitsubishiFR-A840-00122-2-60Controle vetorial, 380-480V, unidade de freio embutidaRepresentative of Japanese performance with convenient debugging
RockwellPowerFlex 525-5.5kW (25B-D017N114)Built-in EMC, multiple communication protocols, safety functionsSuitable for Rockwell automation system integration
Omron3G3RX-A4055-ZV25.5kW, controle vetorial, Modbus/CANopenMiniaturized design with high cost performance
DanfossVLT 2800-5.5kW (132F0015)Built-in EMC, fácil de usar, energy-saving modeSuitable for small machinery applications
  1. Key Replacement Notes

3.1 Correspondência de tipo de carga

Confirm the original load is constant torque (the design target of ATV71); for variable torque loads (ventiladores/bombas de água), it is recommended to use the ATV610 series for higher efficiency.

For heavy-duty applications (por exemplo, hoisting), ATV930 or heavy-duty inverters of other brands must be selected to ensure 150% torque output capacity.

3.2 Key Parameter Migration Points

Parâmetros principais: Acceleration/deceleration time, torque limit, PID parameters, motor nameplate data (must be re-entered).

Communication settings: Modbus address, baud rate and data format must be consistent with the original system.

Safety functions: STO parameters need to be reconfigured to meet the safety class requirements of the original system (ISO 13849 PL e).

3.3 Hardware Compatibility

Dimensões de instalação: ATV340 is slightly smaller and ATV930 is slightly larger than ATV71; confirm the installation space is compatible.

Disposição dos Terminais: The terminal positions of the new series have changed, requiring rewiring.

Accessory Adaptation: Original ATV71 I/O expansion cards and communication cards cannot be directly used for ATV340/930 and need to be replaced with corresponding models.

3.4 Utilization of Function Upgrades

ATV340/930 are equipped with a standard encoder interface (optional for ATV71), enabling higher precision control.

The new series supports industrial Ethernet such as EtherNet/IP, facilitating system upgrade to Industry 4.0.

Enhanced diagnostic functions can early warn of faults and reduce downtime.

  1. Recommended Replacement Implementation Steps

4.1 Preparations

Record all parameters of the original ATV71 (backup with Schneider SoMove software is recommended).

Confirm motor nameplate data (poder, tensão, atual, velocidade, número do pólo).

Evaluate load characteristics (constant torque/variable torque, starting torque requirements, braking needs).

4.2 Selection Confirmation

Select ATV340 or ATV930 series according to the application scenario.

Confirm accessory requirements (communication expansion card, brake resistor, filtro, etc.).

4.3 Instalação & Comissionamento

Install the new inverter with power off and ensure correct wiring (pay special attention to phase sequence).

Enter motor parameters and perform auto-tuning (mandatory step).

Migrate key control parameters and test basic operation.

Verify communication connection and safety functions.

Conduct load test and adjust parameters to the optimal state.

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado