Schneider Electric NSX250N‑3P‑160A

This is a Schneider Electric ComPacT NSX series molded case circuit breaker (MCCB) for power distribution protection. New standard order number: C25N3TM160 Obsolete old order number: LV431832 Compliant with IEC 60947‑2 and GB/T 14048.2 padrões. Basic Rated Core Parameters Item Value Type Low‑voltage MCCB for power distribution protection Frame rating 250A Poles 3P (3 postes, ...

  • Detalhes do produto

This is a Schneider Electric ComPacT NSX series disjuntor em caixa moldada (MCCB) for power distribution protection.

New standard order number: C25N3TM160

Obsolete old order number: LV431832

Compliant with IEC 60947‑2 and GB/T 14048.2 padrões.

  1. Basic Rated Core Parameters
ItemValor
TipoLow‑voltage MCCB for power distribution protection
Frame rating250UM
Poloneses3P (3 postes, all protected)
Rated current In160UM (continuous at 40℃)
Rated operational voltage Ue690Vca 50/60 Hz, suitable for 380V/400V/415V systems
Rated insulation voltage Ui800V e
Rated impulse withstand voltage Uimp8kV
Freqüência50/60Hz
Utilization categoryType A (no short‑time delay, general distribution)
Isolation functionCertified isolating function per IEC 60947‑2
  1. Short‑Circuit Breaking Capacity
Tensão do sistemaRated ultimate shortircuit breaking capacity IcuRated service shortircuit breaking capacity Ics
415V e50o50o (100% UTI, reusable after breaking)
500V e36o36o
690V e10o10o

Rated short‑time withstand current Icw (1é): 12kA at 415V AC

  1. TMD Thermal‑Magnetic Release Characteristics

Standard TMD thermal‑magnetic release, LI protection (long‑time overload + instantaneous short‑circuit).

  1. Long‑time overload thermal protection

Ir setting range: 0.7–1×In (112A–160A)

Characteristic: 120–400s at 1.5×Ir; ≤15s at 6×Ir (standard inverse time)

  1. Short‑circuit instantaneous magnetic protection

Instantaneous current Ii: fixed at 1250A

Operating time: ≤20ms

  1. Mecânico & Installation Parameters
ItemValor
Dimensões (L×A×P)105mm × 161mm × 86mm
Standard mounting centersVertical 125mm × Horizontal 35mm
MontagemFixo, front connected; horizontal/vertical, no derating
Wiring capacityUp to 70mm² copper cable / busbar
Mechanical endurance20,000 operações
Electrical endurance10,000 operations at 440V AC, Em
Ingress protectionIP40 (body), IP54 (panel‑mounted)
Impact resistanceIK07
Net weightAprox.. 2.4kg
  1. Environmental & Compliance Parameters

Temperatura ambiente: -25℃ ~ +70 ℃; no derating below 40℃

Altitude: 0–2000m without derating

Grau de poluição: 3

Overvoltage category: Ii

Certificações: CCC, CE, EAC, Marinho, etc..

Accessory slots: 5 standard slots for auxiliary, alarm, shunt, liberação de subtensão, etc..

  1. Expansion & Compatibilidade

Can be fitted with Vigi earth‑leakage modules

Compatible with motor operators for remote control

Can add interlock, position indicator, padlock devices

Top/bottom feed both allowed without performance derating

Replacement & Notas de seleção

  1. Old type LV431832 is discontinued; use C25N3TM160 instead.
  2. For electronic release (adjustable short delay / falha de terra), upgrade to NSX250N with MicroLogic (2.2/5.0).
  3. Breaking ratings: H (70o), S (100o), based on short‑circuit calculation.
  4. Concorrentes: ABB Tmax T2, Siemens 3VT250, suitable for cross‑brand replacement.

NSX250N‑3P‑160A Direct Replacement Solutions

Core Matching Rules (100% match required)

Frame rating: 250UM (do NOT downgrade to 160A frame)

Poloneses: 3P

Corrente nominal: 160UM

Capacidade de ruptura: ≥50kA at 415V AC

Release type: thermal‑magnetic (LI characteristic)

Montagem: fixed front connection, matching panel holes

  1. Recommended Replacements

Cenário 1: Import Brand Direct Replacement

ABB Tmax XT3N250 TMD160/1600 FF 3P

Pedido nº.: 1SDA068266R1

Corresponder: 100%

Frame 250A, 3P, 160UM, TMG thermal‑magnetic

UTI=50kA, Ics=50kA at 415V AC

Identical dimensions and mounting holes

Full accessory compatibility

Aplicativo: foreign‑funded plants, export equipment, on‑site repair

Siemens 3VC250N TMA160 3P

Pedido nº.: 3VC2316‑2DA33‑0AA0

Corresponder: 98%

Frame 250A, 3P, 160UM, TMA thermal‑magnetic

50kA at 415V AC

Highly compatible dimensions

Aplicativo: Siemens low‑voltage systems

Cenário 2: Domestic High‑Cost‑Performance Replacement

Changshu Switch CM3‑250H/3300 160A

Corresponder: 99%

Frame 250A, 3P, 160UM, distribution type thermal‑magnetic

Icu=50kA at 415V AC

Compliant with IEC 60947‑2 / GB 14048.2

Aplicativo: industrial, building distribution, domestic projects

Chint NM8‑250N/3P 160A

Corresponder: 95%

Frame 250A, 3P, 160UM, thermal‑magnetic

50kA at 415V AC

Aplicativo: civil construction, general distribution

  1. Dimensões & Parameters Comparison
ModeloDimensões (L×A×P)Mounting CentersUTI (415V)ReleaseFrame
NSX250N‑3P‑160A105×161×86mm125mm×35mm50oDTM250UM
ABB XT3N250 3P 160A105×161×86mm125mm×35mm50oTMG250UM
Siemens 3VC250N 3P 160A105×160×85mm125mm×35mm50oTMA250UM
CM3‑250H 3P 160A108×162×86mm125mm×35mm50oThermal‑magnetic250UM

> Observação: ABB XT3N250 matches dimensions and holes 100% – best direct replacement.

  1. Safety Rules for Replacement
  2. No frame downgrade: Do NOT use 160A frame breakers (por exemplo, ABB T2N, NSX160).
  3. Breaking capacity ≥50kA: Do NOT use 36kA / 25kA models.
  4. Release matching: Use distribution‑type thermal‑magnetic only.
  5. Compatibilidade de acessórios: Match auxiliary, shunt, subtensão, earth‑leakage modules.
  6. Final Selection Guide

Direct replacement, import, no cabinet modification: ABB XT3N250 TMD160/1600 FF 3P

New project, domestic approval, cost‑effective: Changshu CM3‑250H/3300 160A

Siemens system replacement: Siemens 3VC250N TMA160 3P