Posicionamento do produto: Safety module for emergency stop & safety gate switch monitoring (Categoria 0 parar). Replacement for legacy XPSAX
Modelos Típicos: XPSAXE5120P / XPSAXE5120C
XPSAXE5120P: Terminais de parafuso removíveis
XPSAXE5120C: Removable spring terminals
Fonte de energia: 24 V CA/CC (AC & CC universal)
Montagem: 35 mm trilho DIN, largura 22.5 milímetros
Dimensões Gerais (L×A×P): 22.5 × 99 × 114 milímetros
✅ Safety Ratings
PL e / Cat.4 (EM ISO 13849-1)|SIL CL3 (CEI 61508 / CEI 62061)
Padrões Aplicáveis: EM ISO 13850 (Parada de Emergência), EM ISO 14119 (Safety Interlock Switches)
- Canal & Definição de terminal (XPSAXE5120)
1) Fonte de energia
A1, A2: Fonte de alimentação do módulo, 24 V CA/CC
2) Safety Inputs (Dual-channel monitoring, dual NC emergency stop / safety switches recommended)
S11-S12: Canal 1
S21-S22: Canal 2
Detects short circuits and wire breaks between dual channels; synchronous response window between channels <0.5 s
3) Start Circuit (Reiniciar)
S33, S34
Short S33 and S34 → Automatic Reset
Connect external NO pushbutton between S33 and S34 → Manual Reset
4) External Contactor Feedback Circuit (Obrigatório!)
Y1, Y2
Wire auxiliary NC contacts of main circuit contactor in series to Y1-Y2;
Função: Prevent unexpected machine startup if contactors weld closed (anti-bounce restart protection).
5) Saídas de segurança (3 sets of instantaneous NO safety contacts)
13-14, 23-24, 33-34
Three independent relé de segurança contacts for de-energizing power contactor coils.
Single contact rated current: 6 UM; AC-15: 360 VA continuous load; DC-13: 24 V/1.5 A.
6) Auxiliary PLC Signal Output (Non-safety circuit!)
41-42: 1 set of NC signal contacts
Only used for status feedback to PLC. Strictly prohibited for safety cut-off circuits.
7) LED Indicators
PWR: Power supply present
CORRER: Safety circuit closed, outputs energized
- Lógica Operacional
- Ligar; emergency stop reset & safety gate closed → S11-S12 / S21-S22 conductive
- Y1-Y2 feedback circuit closed (main contactor de-energized)
- Press reset button (or auto-reset active) → internal dual relays energize
- 13-14 / 23-24 / 33-34 fechar, machine operation permitted
- Emergency stop triggered / gate opened / wiring fault detected → three safety outputs open instantaneously (≤80 ms)
- Reset is blocked until all faults are cleared
- Recommended Typical Wiring Schemes
- Standard Scheme (Dual NC Emergency Stop + Redefinição manual + Opinião)
A1/A2: 24 Fonte de alimentação V
Dual NC emergency stop: Common power feed, two channels routed separately to S11-S12 and S21-S22
NO start pushbutton wired across S33-S34
Auxiliary NC contacts of main power contactor wired in series to Y1-Y2
13/23/33 connected to power; 14/24/34 wired in parallel to drive main contactor coil
- Prohibited Practices
Do NOT use 41-42 signal contacts for safety cut-off
Do NOT omit Y1-Y2 feedback circuit (losses anti-weld protection, cannot achieve Cat.4)
Single-channel wiring only achieves PL d/Cat.3, fails high-end machine requirements
- Key Notes for Legacy XPSAX Replacement (Common Application)
Legacy model: XPSAX5120 → Replace with XPSAXE5120P
- Terminal assignments not fully pin-to-pin compatible, direct plug replacement is impossible; terminal wiring must be rechecked
- XPSAXE adopts removable terminals for easier cabinet wiring and maintenance
- Height dimension increased; verify available installation space
- Identical operating logic and safety rating
- Series Selection Comparison Reference
XPS-AXE: Parada de emergência / monitoramento de portão de segurança, 3 NO safety outputs, with feedback; Categoria 0 parar
XPS-AC: Compactar 22.5 mm largura, similar functions with minor load capacity differences
XPS-AK: Supports safety light curtains, safety mats; funções aprimoradas, custo mais alto
- Solução de problemas comuns
- RUN LED off after power-up
Verify S11/S21 both channels are conductive
Check continuity of Y1-Y2 (confirm contactor not welded)
- Machine cannot restart after emergency stop release
Confirm reset mode: short S33 and S34 for automatic reset
Short circuit or wire break detected in dual input channels
- Random tripping during operation
Total wiring resistance of input cables exceeds limit (≤50 Ω); use larger cross-section cables for long wiring runs
I can provide:
✅ Text version of standard wiring schematic
✅ Full datasheet parameters of XPSAXE5120P
✅ Terminal comparison table: XPSAX vs XPSAXE
Application Scenarios of Schneider XPS-AXE (XPSAXE5120P/C) Relé de segurança
Core Position Recap
Only supports two safety input types: dual-channel dual NC emergency stop pushbuttons + safety gate interlock switches
Classificação de segurança: PL e / Cat.4, SIL CL3, Categoria 0 instantaneous power cut-off
Not compatible with: Safety light curtains, safety mats, dispositivos de controle bimanuais;
Configuração padrão: External contactor feedback circuit (Y1-Y2), 3 safety NO outputs, 1 PLC status signal output; supports Manual Reset / Reinicialização automática.
- Supported Safety Functions
- Emergency Stop Circuit Monitoring (ISO 13850) : Monitoring machine main emergency stop and zone emergency stop via dual channels
- Safety Guard Door Interlock Monitoring (ISO 14119) : Mechanical fences, access doors, protective hood interlock switches
Applicable switches: Dual NC safety gate switches, magnetic safety interlock switches (Contatos NC)
- Industry Typical Applications
1) Máquinas-ferramentas gerais & Metalworking Equipment
Tornos CNC, centros de usinagem, fresadoras, moedores
Small presses, hydraulic machines, press brakes, shears
Cutting machines, moedores, deburring equipment
Uso: Machine panel emergency stop + electrical cabinet door / protective hood interlock
2) Embalagem, Impressão & Rubber/Plastics Machinery
Vertical form fill seal machines, flow wrappers, case packers, auxiliary palletizing equipment
Blow molding machines, injection molding auxiliary equipment, small extrusion lines
Máquinas de impressão, laminators, die-cutters
Características: Risk of nipping between rollers and conveyors; immediate machine shutdown required upon guard door opening
3) Transporte & Logistics Automation Equipment
Transportadores de correia, roller conveyors, transfer units, lifting transfer tables
Small automated storage systems, sorting workstations, single units on packaging lines
Guard fence interlock at roller conveyor corners
4) Small Robot Workcells
Compact 6-axis robots, SCARA robot single-unit safety fencing
⚠️ Limitation: Only for fence door + workstation emergency stop monitoring. Additional XPS-AK safety relay required if safety light curtains are deployed.
5) Comida & Pharmaceutical Packaging Equipment
Máquinas de enchimento, capping machines, máquinas de etiquetagem, auxiliary sterilization equipment
Food cutting and material handling standalone machines
Vantagens: 24 V AC/DC wide range power supply, compact DIN rail mounting; meets CE requirements for export machinery
6) Carpintaria & Composite Processing Machinery
Bandadoras de borda, nesting CNC routers, engraving machines, sanders
Corte de painel, small composite hot-press equipment
7) Test Benches & Custom Automation Machinery
Component air-tightness test stations, press-fit custom machines, torque tightening equipment
Small lithium battery assembly equipment, inspection tooling
Widely adopted for safety circuit construction on custom machines to satisfy EU Machinery Directive & CE marking
- Typical Wiring Application Schemes
- Scheme A: Single Machine with Emergency Stop + Portão de Segurança (Mais Comum)
Two channels wired in series: Dual NC emergency stop + dual NC safety gate. Machine shuts down immediately upon activation of either device.
Suitable for standalone equipment fitted with protective hoods and safety fences.
- Scheme B: Dual-channel Emergency Stop Monitoring Only
Both channels connected to dual NC emergency stop without safety gates; used for open-frame equipment only equipped with emergency stop protection.
- Scheme C: Safety Guard Door Monitoring Only
Two channels connected to safety gate switches, working with zone emergency stops to form the complete machine safety system.
- Aplicativos inadequados (Armadilhas de seleção)
- Required interface with safety light curtains, safety mats, safety edges → Select XPS-AK / XPSUAK
- Required time-delayed shutdown (Category1/2 stop) → XPS-ATE time-delay series
- Required two-hand control function → XPS-AB
- Mixed multiple safety signals (cortina de luz + portão de segurança + parada de emergência) → Universal XPSUAF safety module
- Solid-state safety outputs required (sem contatos mecânicos) → Models with semiconductor outputs
- Key Selection Reminders
Direct replacement for legacy XPSAX5120: XPSAXE5120P (terminais de parafuso) / XPSAXE5120C (terminais de mola)
Compact cabinet alternative with equivalent functions: Compare XPSAC5121
To achieve Cat.4 safety rating, Y1-Y2 contactor feedback circuit cannot be omitted
I can organize:
✅ Text version of standard XPSAXE wiring diagram
✅ Safety function description text for CE risk assessment (directly usable in machine manuals)
Detailed Analysis of Y1-Y2 External Contactor Feedback Circuit for Schneider XPS-AXE (XPSAXE)
Terminals Y1, Y2
Connect auxiliary Normally Closed (NC) contacts of main power contactors
⚠️ This circuit must not be omitted to achieve PL e / Cat.4
- Four Core Functions
1) Anti-Weld Contactor Protection (Mais crítico)
Cenário: Main contactor main contacts weld closed due to high current ablation or mechanical jamming.
Normal shutdown: Contactor coil de-energized, principais contatos abertos; auxiliary NC contacts restore closed state, Y1-Y2 conductive.
Weld fault condition: Safety relay cuts outputs, but main power circuit remains energized; auxiliary NC contacts stay open → Y1-Y2 circuit opens.
XPS-AXE detects open Y1-Y2 circuit, locks safety system and blocks reset, preventing unexpected machine startup and severe safety hazards.
- Closed-loop safety monitoring to meet EN ISO 13849 Cat.4
Cat.4 safety standard requires the system to detect faults of its actuators (contatores).
If Y1-Y2 feedback is omitted:
Safety rating downgrades to PL d / Cat.3, failing requirements for high-end machinery and CE export certification.
- Prevent Recurring Start-Stop Oscillation
After machine trips without feedback monitoring:
The safety relay may repeatedly attempt to energize/de-energize contactors in certain conditions, accelerating contact arc erosion.
Feedback logic ensures: Reset is only permitted after the contactor is fully de-energized.
- Logic Interlock to Verify Actuator Status
Reset conditions of safety relay add one prerequisite: Confirm all power contactors are in de-energized state.
Full reset sequence conditions:
- Parada de emergência / safety gate dual-channel inputs return to closed state
- Y1-Y2 feedback circuit conductive (contactor confirmed open)
- Execute manual or automatic reset
- Standard Wiring Rules
- Wire auxiliary NC contact of contactor in series. DO NOT use NO contacts!
- Only contacts can be wired between Y1 and Y2; parallel components are prohibited.
- Multiple contactor setup: Auxiliary NC contacts of all main contactors must be wired in series into Y1-Y2 (reset allowed only when all contactors open).
- Common Wiring Mistakes & Consequences
❌ Mistake 1: Direct short-circuit Y1-Y2
Conseqüência: Feedback function disabled, loss of weld detection. Safety rating downgraded to PL d, Cat.4 claim invalid; non-compliant during CE audit. Risk of sudden machine startup if contactor welds.
❌ Mistake 2: Connect contactor NO contacts
Conseqüência: Y1-Y2 opens when contactor energizes → safety relay trips continuously during machine operation, equipment cannot run.
❌ Mistake 3: Only one contactor connected in feedback while multiple power contactors exist
Conseqüência: Weld failure of any unmonitored contactor cannot be detected, creating safety blind spot.
- Plain-language Summary
The safety relay issues the shutdown command. Y1-Y2 feedback confirms whether the contactor actually opens as commanded.
If contactor sticks closed and fails to open, the safety relay locks the system and prevents machine restart.
Supplementary Notes for XPS-AXE
Feedback circuit belongs to safety-related wiring; separate routing from power cables is recommended.
For local machines without export requirements where only PL d is demanded, shorting Y1-Y2 is theoretically possible but not recommended by Schneider official manuals. All risks shall be borne by the machine manufacturer.