Brand: Schneider Electric
Series: Easy 7 (Project Type/EZ7 Series)
Order Number: EZ711603G
Modelo: EZ7DPN 4.5kA 1P+N C16A
Pole Configuration: 1P+N (Phase Wire + Neutral Wire)
Corrente nominal: 16UM
Trip Characteristic: Tipo C (Distribution Protection Type)
Quebrando Capacidade: 4.5o
Tensão nominal: 230VAC
Frequency: 50/60Hz
Dimensões: Approximately 18mm wide (standard width per pole)
Model Interpretation
EZ7: Easy 7 Series
DPN: 1P+N Structure (controls phase wire and neutral wire simultaneously)
C: Trip characteristic (Type C suitable for distribution protection)
16: Rated current of 16 amperes
G: Product series suffix identifier
Recursos funcionais
- Overload Protection: When the circuit current exceeds 16A, o disjuntor will trip within a certain time to protect wires and equipment.
- Proteção contra curto-circuito: Quickly (in milliseconds) cuts off the circuit when a short circuit occurs, with a breaking capacity of 4.5kA.
- Simultaneous Disconnection of Phase and Neutral Wires: Enhances electrical safety and prevents accidental electric shock.
- Type C Trip Characteristic: Short-circuit tripping current is 5-10 vezes a corrente nominal (80-160UM), suitable for conventional distribution protection.
Cenários de aplicação
Residential Distribution Boxes: Protection for lighting circuits and socket circuits.
Edifícios Comerciais: Terminal power distribution in offices, shops, and other venues.
Industrial Equipment: Protection for single-phase power supply equipment.
General Distribution Systems: Terminal power distribution protection for industrial, comercial, and civil use below 400V.
Detailed Technical Specifications
| Parâmetro | Value |
| Tensão operacional nominal | 230V e |
| Rated Current Range | 6/10/16/20/25/32/40UM |
| Trip Characteristic | Tipo C (5-10Em) |
| Quebrando Capacidade | 4.5o |
| Vida Mecânica | ≥20,000 cycles (C-O cycles) |
| Certifications | CCC, CE, RoHS |
| Largura | 18milímetros (1P+N) |
Usage Notes
- Ensure the power supply is disconnected before installation, and confirm no voltage in the circuit using professional voltage detection equipment.
- Only use under the rated voltage (230VAC).
- Ensure wiring is secure to avoid overheating caused by loose connections.
- Regularly inspect the circuit breaker status to ensure proper operation.
The Schneider EZ7DPN-C16 (EZ711603G) is an economical 1P+N miniature circuit breaker with reliable overload and short-circuit protection functions, suitable for single-phase distribution systems in residential, comercial, and industrial settings. The Type C trip characteristic makes it particularly suitable for protecting conventional loads such as lighting and sockets, while the 4.5kA breaking capacity is sufficient to handle short-circuit faults in general household and small commercial environments.
Installation Specifications for Schneider EZ7DPN-C16 Circuit Breaker (EZ711603G)
- Safety Preparation
- Power Disconnection: Disconnect the upstream power supply before installation, and confirm no voltage in the circuit using professional voltage detection equipment.
- Professional Installation: Must be installed by qualified electricians in compliance with electrical safety standards (NFPA 70E, GB 50149, etc.).
- Personal Protective Equipment (PPE): Wear insulating gloves, safety goggles, and other PPE.
- Installation Environment:
Dry, well-ventilated environment free of corrosive gases.
Ambient temperature: -5℃~40℃, relative humidity ≤90% (at 25℃).
Avoid vibration, high-temperature, or humid locations.
- Etapas de instalação
- Instalação em trilho DIN (if not pre-installed in the distribution box)
Use a 35mm standard DIN rail, ensuring the rail levelness ≤2mm/m.
Fix the rail to the distribution box base with M4 screws, spacing ≤300mm.
The rail must be reliably grounded (connect to the distribution box grounding bar with a yellow-green grounding wire).
- Circuit Breaker Installation
Vertical Installation (Recommended): Handle facing upward, tilt angle not exceeding 5°.
Horizontal Installation (Special Cases): Ensure flexible operation and that the closing direction complies with markings.
Specific Operations:
- Align the buckle on the back of the circuit breaker with the upper edge of the DIN rail.
- Press the circuit breaker downward until a “click” sound is heard, indicating it is securely snapped into the rail.
III. Especificações de fiação
- Wiring Principles
“Top In, Bottom Out”: Upper terminals for power incoming wires, lower terminals for load outgoing wires.
“Neutral on Left, Phase on Right”: When facing the front of the circuit breaker, connect the neutral wire (N) to the left terminal and the phase wire (L) to the right terminal.
Strict Distinction: The N pole of the 1P+N circuit breaker has no protection function; reverse connection of phase and neutral wires is strictly prohibited.
- Terminal Connection Steps
- Strip the wire insulation (approximately 10-12mm) without damaging the conductor.
- Insert the wire into the corresponding terminal (L for phase wire, N for neutral wire).
- First hand-tighten the terminal screw until the wire is secure, then tighten it to the specified torque with a torque wrench.
Terminal Markings:
L (or unmarked): Connect to phase wire (live wire).
N: Connect to neutral wire.
- Technical Parameters and Installation Requirements
| Parâmetro | Value | Description |
| Tensão nominal | 230V e | Only suitable for 230V systems |
| Corrente nominal | 16UM | Matches loads ≤16A |
| Quebrando Capacidade | 4.5o | Maximum breaking capacity during short circuits |
| Trip Characteristic | Tipo C (5-10Em) | Suitable for general distribution protection |
| Largura | 18milímetros (1P+N) | Standard modular design |
| Wiring Torque | 1.5-3N·m | Torque screwdriver recommended |
| Applicable Wires | 2.5-4mm² copper wires | Select based on load current |
- Precauções de instalação
- Key Prohibitions
Prohibited Inverted Installation: Upside-down installation is not allowed.
Prohibited Reverse Connection: Incorrect connection of N and L poles is forbidden; de outra forma, the breaker may not trip in case of leakage.
Prohibited Neutral Wire Parallel Connection: When multiple residual current circuit breakers are installed side by side, parallel connection of outgoing neutral wires is strictly prohibited.
- Clearance Requirements
Horizontal distance from adjacent equipment≥200mm, vertical distance≥150mm for easy operation and maintenance.
Distance between high-voltage and low-voltage equipment in the distribution box ≥50mm to reduce interference.
- Wiring Points
Ensure terminal connections are secure to avoid overheating affecting protection performance.
Use a PZ-type Phillips screwdriver (recommended) to prevent thread slipping.
Do not press the wire insulation into the terminal to ensure electrical clearance.
- Post-Installation Inspection
- Insulation Test: Check circuit insulation with an insulation resistance tester (≥0.5MΩ).
- Function Test:
Manually close and open the breaker 3 times to confirm flexible operation.
Conduct simulated overload and short-circuit tests if conditions permit (performed by professionals).
- Marking: Label the circuit purpose on the breaker or distribution box for easy maintenance.
VII. Recomendações de manutenção
Regularly inspect the tightness of circuit breaker connections, especially after long-term use.
Keep the circuit breaker surface clean to avoid dust accumulation affecting heat dissipation.
If the breaker trips frequently, troubleshoot the fault first rather than resetting repeatedly.
The key to installing the Schneider EZ7DPN-C16 circuit breaker lies in: safe power disconnection, correct installation (vertical or horizontal), standardized wiring (“Top In, Bottom Out”; “Neutral on Left, Phase on Right”), and reliable fixation on a 35mm DIN rail with proper grounding. After installation, perform a function test to ensure normal protection performance.
Translation Notes for Export Business:
- Terminology Consistency: Adopted international standard electrical terms (por exemplo, “1P+N” retained, “trip characteristic” instead of “tripping feature”) for global customer understanding.
- Standard References: Retained original standard codes (NFPA 70E, GB 50149) with English names for compliance verification in target markets.
- Unit Clarity: Specified units (por exemplo, “mm²”, “N·m”) with international symbols for technical accuracy.
- Practical Expressions: Used concise phrases (por exemplo, “securely snapped into”, “strictly prohibited”) suitable for technical documents and customer communication.
- Certification Retention: Kept original certification marks (CCC, CE, RoHS) to facilitate import customs clearance and product certification in overseas markets.