Disjuntor do motor Schneider GV3P50 - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Disjuntor do motor Schneider GV3P50 - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

disjuntor/

Disjuntor do motor Schneider GV3P50

The Schneider GV3P50 motor circuit breaker is an ideal choice for protecting 22kW three-phase motors. Featuring thermal-magnetic tripping, an adjustable current range of 37–50A, a breaking capacity of 100kA and IP20 ingress protection rating, it is widely deployed in industrial automation, fluid conveyance, building facilities and other sectors. Key points: match breaker rating to motor ...

  • Detalhes do produto

The Schneider GV3P50 motor circuit breaker is an ideal choice for protecting 22kW three-phase motors. Featuring thermal-magnetic tripping, an adjustable current range of 37–50A, a breaking capacity of 100kA and IP20 ingress protection rating, it is widely deployed in industrial automation, fluid conveyance, building facilities and other sectors. Key points: match breaker rating to motor power and operating conditions; avoid non-recommended applications including DC circuits, high-frequency starting and high-altitude environments. Combined with contactors and auxiliary contacts, it forms a complete motor protection and control system.

Segmento de códigoDefiniçãoDescrição detalhada
GV3Série de produtosTeSys GV3 range motor circuit breakers for three-phase motor protection
PTipo de produtoStandard thermal-magnetic trip unit with rotary knob operation
50Corrente nominalMax adjustable trip current 50A; thermal trip setting range: 37–50A
Modelo CompletoGV3P503-pole thermal-magnetic motor breaker, 37–50A, EverLink BTR screw terminals, IP20
Código do pedidoFD6887Schneider official standard part number
  1. Core Technical Specification Table
Categoria de parâmetroDados TécnicosObservações
Parâmetros Básicos
Configuração do Pólo3P (3-pólo)For three-phase AC circuits
Tipo de viagemTérmico-MagnéticoCombines thermal overload protection & magnetic short-circuit protection
Modo de operaçãoRotary Knob ControlManual switching with ON/OFF marking
TerminationEverLink BTR screw-clamp terminalsFast wiring to reduce loose connection risks
Parâmetros Elétricos
Thermal Trip Adjustment37–50ACompatible with motors of different rated powers
Tensão operacional nominal (interface do usuário)690V e50/60Hz
Tensão nominal de isolamento (Ué)690V eCompatível com IEC 60947-2
Corrente Operacional Nominal (Ou seja)50UMCorrente máxima de operação contínua
Corrente de Disparo Magnético700UMShort-circuit instantaneous tripping value
Capacidade de ruptura final (UTI)100oA 400 V
Matched Motor Rating22kW @ 400 VFor three-phase asynchronous motors
Mecânico & Ambient Parameters
Proteção de entradaIP20Finger-touch safe against live components
MontagemMontagem em trilho DINStandard 35mm top-hat rail
PesoAprox.. 0.45kgFácil instalação & transportation
Temperatura operacional-25°C ~ +60°CSuitable for most industrial environments
Temperatura de armazenamento-40°C ~ +85°CWide storage temperature range
Certificações
Main ApprovalsCE, UL, CSA, CCC, EACGlobally certified per international standards
Eco CertificationsRoHS, ALCANÇAREU-compliant environmentally friendly design

III. Full GV3P Series Model List

ModeloThermal Trip RangeMatched Motor Power @400VCorrente de Disparo MagnéticoCódigo do pedido
GV3P4025–40A18.5kW600UMFD6886
GV3P5037–50A22kW700UMFD6887
GV3P6548–65A30kW800UMFD6888
GV3ME5037–50A22kW700UMFD6890
GV3ME6548–65A30kW800UMFD6891
GV3ME8056–80A37kW1000UMFD6892
GV3ME10070–100A45kW1200UMFD6893
  1. Alternative Cross Reference (Modelos de substituição)
  2. In-house Schneider Replacement
Modelo originalSubstituiçãoDescrição
GV3P50GV3ME50Identical performance; ME is enhanced version with better accessory compatibility
GV3P50New production GV3P50No functional change, only production batch update
  1. Equivalentes entre marcas
MarcaModelo EquivalenteMatching GradeVantagens
ABBMS132-50★★★★★Mesma classificação atual, interchangeable mounting dimension
Siemens3RV2031-4KA10★★★★☆Viagem termomagnética, fits 22kW motors
EatonPKZM0-50★★★★☆3-projeto de poste, 100capacidade de interrupção kA
ChintNDM2-63M/3300★★★☆☆Cost-effective for bulk replacement
DeliciosoCDM1-63M/3300★★★☆☆Well-known domestic brand with high cost-performance
  1. Ambientes de aplicativos & Field Cases
  2. Aplicativos recomendados

Automação Industrial: Sobrecarga & short-circuit protection for 3-phase asynchronous pumps, fans and compressors

Fabricação: Production line motor control & machine tool protection

Elétrica predial: Central air-conditioning & fire-fighting pump control

Setor Energético: Front-end protection for small generator sets and inverters

Infraestrutura: Wastewater treatment equipment & bulk material conveying systems

  1. Aplicativos não recomendados

DC Circuits: Designed exclusively for AC; abnormal tripping characteristics under DC supply

Ultra-Frequent Cycling: Not applicable for >30 starts per hour (accelerates trip unit aging)

High Altitude: Derating mandatory above 2000m elevation

Corrosive Atmosphere: No anti-corrosion coating; unsuitable for strong acid/alkali surroundings

  1. Casos de aplicação típicos

Caso 1: Fan System Protection for Food Processing Plant

Equipamento: 3×22kW centrifugal fans, 380V/50Hz

Solução: GV3P50 + LC1D65 contactor combination

Resultado: Proteção tripla contra sobrecarga, curto-circuito & perda de fase; equipment failure rate reduced by 40%

Caso 2: Submersible Sewage Pump Control at Wastewater Plant

Equipamento: 4×22kW submersible sewage pumps, 380V/50Hz

Solução: GV3P50 + contatos auxiliares + PLC interlock control

Resultado: Full motor protection plus remote monitoring, lower maintenance expense

  1. Conformidade de Remessa Aérea & Certificação CE
  2. Conformidade com frete aéreo

UN38.3: Não obrigatório; no built-in lithium battery or supercapacitor inside

Classe de envio: General commodity without special transport restriction

Embalagem: Standard industrial carton to avoid transit damage

Shipping Document: Copy of CE certificate + RoHS compliance declaration available

  1. CE Certification Details

Padrões Aplicáveis: CEI 60947-2 (LV switchgear) & CEI 60947-4-1 (motor control equipment)

Valid Region: European Economic Area (EEE) & global territories accepting CE marking

Validity: Permanently valid complying with current normative requirements

Investigação: Check Schneider official website product page or certification database

VII. Solução de problemas de falhas comuns

Sintoma de falhaProbable CausesRemedial Actions
Frequent thermal tripping1. Sobrecarga do motor1. Inspect motor load
2. Underset trip current2. Adjust rotary knob to correct setting
3. Excess ambient temperature3. Improve ventilation or derate operating current
Não é possível fechar1. Tripping latch not reset1. Toggle knob OFF then ON to reset
2. Short circuit in wiring2. Troubleshoot short-circuit faults
3. Bloqueio mecânico3. Clean or replace breaker
No protection upon phase loss1. Fiação errada1. Recheck three-phase cabling
2. Damaged trip unit2. Replace trip component
3. Severe 3-phase unbalance3. Balance connected loads
Overheated terminals1. Terminais soltos1. Reaperte os parafusos do terminal
2. Undersized cable2. Upgrade to proper wire gauge
3. Terminal oxidation3. Clean terminals or replace unit

VIII. Sizing Guidelines & Regras de seleção rápida

Quick Selection Formula Summary

> GV3P series 3-pole thermal-magnetic breakers;

> Suffix number denotes upper current limit;

> 40 = 25–40A, 50 =37–50A, 65 max at 65A;

> Power matching rule: 40 for 18.5kW, 50 for 22kW, 65 for 30kW.

Quick Rules

  1. Correspondência atual: Motor rated current ×1.1 ≤ breaker setting ≤ motor rated current ×1.3
  2. Power Reference: A 400 V, GV3P50 matches 22kW motor (~44A nominal)
  3. Accessory Option: Contato auxiliar: GV3AE11 (1NÃO+1NC) / GV3AE20 (2NÃO)
  4. Espaçamento de montagem: DIN rail install; ≥10mm clearance for heat dissipation, away from heat-generating devices
  5. Instalação & Wiring Instruction
  6. Etapas de instalação

Confirm standard 35mm DIN rail

Snap breaker firmly onto rail

Incoming power: top-feed or bottom-feed acceptable

Motor cable connection: terminal tightening torque 2.5Nm recommended

  1. Especificação de fiação

Wire cross-section range: 1.5mm² min ~35mm² max

terminal: EverLink BTR screw terminal compatible with copper/aluminum conductors

Phase marking: R/S/T corresponds to L1/L2/L3; no neutral connection (3P without N pole)

  1. EMC Protection

Maintain ≥50mm clearance between breaker and contactors

Separate control wiring from power cables to avoid cross-interference

Install EMC filter if needed for EMI suppression

Full Application Overview for Schneider GV3P50 Motor Circuit Breaker

  1. Core Application Summary

Schneider GV3P50 is a 3-pole thermal-magnetic motor circuit breaker with adjustable trip 37–50A, rated for 22kW three-phase asynchronous motors @400V. Its core functions: motor overload, curto-circuito & phase-loss protection plus manual switching, widely used in below industries:

  1. Detailed Application Classification
  2. Automação Industrial & Fabricação
AplicativoEquipamentoProtection RequirementApplication Benefit
Production Line ControlTransportadores, sorters, máquinas de embalagemContinuous running protection against overload shutdownImprove line stability & reduce breakdown loss
Máquinas-ferramentasMilling, lathe & grinder spindle motorsProtection for frequent start-stop & instant short-circuit breakingProtect costly equipment and extend service life
Bulk HandlingBucket elevators, transportadores helicoidaisParar & phase-loss protectionPrevent burnout & cut maintenance cost
General MachineryImpressão, têxtil & plastic processing machinesProteção contra sobrecarga + emergency manual cut-offSimplify control circuit & enhance operational safety
  1. Fluid Conveyance Systems
AplicativoEquipamentoRecurso de proteçãoTypical Parameter
Pump SetIndustrial pump, fire pump, sewage pumpDual overload + phase-loss protection, resistente à umidade22kW/380V,50Hz, setting 37–50A
Fan UnitCentrifugal/axial/induced draft fansLight-load startup protection against impeller jammingAdapt to current fluctuation from variable duct resistance
CompressorAr & refrigeration compressorsHeavy-start & overheat protectionTolerate frequent loading/unloading cycles
Vacuum PumpIndustrial & water-ring vacuum pumpsLow-current idle-running damage preventionAdjustable setting for light-load operation
  1. Prédio & Municipal Infrastructure
SectorSistemaKey DemandMétodo de montagem
AVACCentral air-con, air handler, cooling towerStable continuous-duty protectionDIN rail mounted with contactor interlock
Automação PredialFire control, segurança & elevator room equipmentEmergency cut-off safetyRemote monitoring via PLC
WastewaterAerator & sludge processing unitsPó & moisture resistanceCabinet installation with IP20 protection
Nova EnergiaSmall gen-set & PV inverterSobrecorrente & grid-fault isolationRated up to 690V high-voltage system
  1. Other Industrial Sectors
IndústriaEquipamentoSpecial RequirementMatching Advantage
AgriculturaIrrigation pump & feed processorOutdoor installation against grid voltage swingWide operating temp: -25°C~+60°C
MineraçãoSmall conveyor & mine ventilation fanHeavy startup + alta resistência a curto-circuito100kA alta capacidade de interrupção
Comida & BebidaMixer & equipamento de esterilizaçãoSanitary & easy-clean layoutNo exposed live parts for hygiene compliance
PharmaFarmacêutico & cleanroom machineryPrecise control & baixa taxa de falhasHigh accuracy thermal-magnetic trip characteristic

III. Aplicativos não recomendados (Avoidance Guide)

Unsuitable ConditionRazãoAlternative Solution
DC CircuitAbnormal tripping characteristic under DC (rated only AC 50/60Hz)Dedicated DC-rated Schneider circuit breakers
>30 Starts/HourAccelerated trip unit ageing & shortened service lifeGV3ME enhanced series or match with soft starter
Altitude>2000mPerformance derating requiredHigh-altitude specified breaker or add upstream protection
Strong Corrosive AtmosphereUncoated terminals prone to oxidationAnti-corrosion coated model or protective enclosure
Explosion Hazard ZonesStandard version without ATEX certificationATEX certified explosion-proof breakers
Single-Phase Motors3-pole structure cannot provide single-phase protectionGV2 single-phase motor breaker series
  1. Detailed Field Application Cases

Case1: 22kW Fan Protection in Food Factory

Setup: 3×22kW centrifugal fans 380V/50Hz, independent control per unit

Esquema: GV3P50 + LC1D65 contactor + GV3AE11 auxiliary contact

Lógica: Manual/Auto switch; auto stop & alarm upon overload

Resultado: Triple protection realized; failure rate -40%, maintenance cost -30%

Case2: Submersible Sewage Pump Control at WWTP

Setup: 4×22kW submersible sewage pumps 380V/50Hz, alternating operation

Esquema: GV3P50 + PLC interlock + level transducer

Doença: Ambiente úmido, 10~15 starts/hour frequent cycling

Resultado: Anti-stall burnout + remote auto-switching, improved system reliability

Case3: Central Air-conditioning for Shopping Mall

Setup: 3×22kW chilled water pumps with VFD control 380V/50Hz

Esquema: GV3P50 + inversor + temperature sensor

Recurso: Speed auto-adjust by return water temp; coordinated protection by inverter + breaker under overload

Resultado: ≥30% energy saving, vida útil duplicada, superior system stability

  1. Recommended Matching Components & Dicas de seleção
  2. Recommended Matching List
AcessórioNúmero da peça.FunçãoValor
Contator CALC1D65Remote control for frequent start-stopEnable automatic control & reduce manual operation
Contato AuxiliarGV3AE111NO+1NC signal outputAlarm feedback or PLC interlock
Relé de sobrecarga térmicaLRD4363Optional secondary overload protectionDouble motor protection for enhanced safety
Control PushbuttonXB4 SeriesManual start/stopIHM & emergency shutdown function
  1. Sizing Rules
  2. Power Match: 22kW (~44A @400V) optimally paired with GV3P50 (37–50A)
  3. Trip Setting: Motor rated current ×1.1 ≤ breaker setting ≤ motor rated current ×1.3
  4. Mount Clearance: ≥50mm gap to adjacent contactors; ≥10mm free space for heat dissipation
  5. Torque de fiação: Cable terminal tightening torque fixed at 2.5Nm
  6. Ambient Derate: Desclassificar 1% rated current per every 1°C rise above +40°C ambient temperature