Schneider GV2PM10C Motor Circuit Breaker

A classic motor protection series from Schneider Electric, designed for low-power motors rated 0.1-32A. It provides protection against short circuit, overload and phase loss. Equipped with a rotary knob for manual closing and tripping, and built-in thermal-magnetic trip unit to deliver delayed overload protection and instantaneous short-circuit protection. O código 10 represents an adjustable setting ...

  • Detalhes do produto

A classic motor protection series from Schneider Electric, designed for low-power motors rated 0.1-32A. It provides protection against short circuit, overload and phase loss. Equipped with a rotary knob for manual closing and tripping, and built-in thermal-magnetic trip unit to deliver delayed overload protection and instantaneous short-circuit protection. O código 10 represents an adjustable setting current range of 4-6.3A, compatible with 1.5-2.2kW three-phase motors at 400V. Models suffixed with C are domestic versions, while those without C are imported versions. Both share identical performance parameters and comply with IEC and GB standards.

  1. Explicação do código do modelo
SegmentoGV2PM10C
SignificadoSérie de produtos: TeSys Deca GV2 disjuntor do motorOperation type: Panel Mount Rotary Knob with thermal-magnetic protectionSetting current range code: 4-6.3UMOrigin code: Manufactured in China
  1. Principais Especificações Técnicas
CategoriaDados TécnicosObservações
Informações gerais
Nome do produtoTeSys Deca GV2PM Motor Circuit BreakerSpecifically designed for motor control and protection
Código do pedidoGV2PM10CStandard commercial model
Status do produtoAtivoStandard product of Schneider Electric
Parâmetros Elétricos
Poloneses3P (Trifásico)For three-phase asynchronous motors
Configurando o intervalo atual4-6.3UMAdjustable via rotary knob, for 1.5-2.2kW motors (400V)
Corrente Operacional Nominal (É)6.3UMCorrente máxima de operação contínua
Tensão nominal de isolamento (interface do usuário)690VWithstand voltage level of insulation system
Tensão operacional nominal (Ué)400V e (50/60Hz)Standard industrial voltage
Capacidade nominal máxima de interrupção de curto-circuito (UTI)100kA @ 400VCompatível com IEC 60947-2
Tipo de proteçãoTermomagnéticoDelayed overload protection + proteção instantânea contra curto-circuito
Parâmetros Mecânicos
Dimensões (L×A×P)89mm×85mm×91mmCompact structure to save cabinet space
PesoAprox.. 280gEasy for installation and maintenance
Montagem35mm montagem em trilho DINCompatível com EN 60715
TerminaisTerminais de parafuso, for 1.5-4mm² conductorsSuitable for solid and stranded wires
Modo de operaçãoBotão giratório (OFF-ON-RESET)Manual reset required after tripping
Parâmetros Ambientais
Temperatura operacional-20°C ~ +60°CAdaptable to industrial environments
Proteção de entradaIP20Prevents finger access to live parts
CertificaçõesCE, CCC, UL, CSAEm conformidade com os padrões internacionais de segurança
  1. Full Range of GV2PM Rotary Knob Motor Circuit Breakers
ModeloConfigurando o intervalo atualPotência do motor correspondente (400V)Observações
GV2PM01C0.1-0.16UM0.025-0.04kWMinimum current rating
GV2PM02C0.16-0.25UM0.04-0.06kW
GV2PM03C0.25-0.4UM0.06-0.1kW
GV2PM04C0.4-0.63UM0.1-0.16kW
GV2PM05C0.63-1UM0.16-0.25kW
GV2PM06C1-1.6UM0.25-0.4kW
GV2PM07C1.6-2.5UM0.4-0.63kW
GV2PM08C2.5-4UM0.63-1.1kW
GV2PM10C4-6.3UM1.1-2.2kWCurrent model
GV2PM14C6.3-10UM2.2-3kW
GV2PM16C9-14UM3-4kW
GV2PM20C13-18UM4-5.5kW
GV2PM21C17-23UM5.5-7.5kW
GV2PM22C23-32UM7.5-11kWMaximum current rating
  1. Concorrente & Modelos Equivalentes
MarcaModeloConfigurando o intervalo atualModo de operaçãoDescrição da substituição
Schneider ElétricaGV2ME10C4-6.3UMPush-buttonAlternative with different operation mode within the same series
Siemens3RV2011-0JA104-6.3UMBotão giratórioCross-brand functional replacement
ABBMS116-6.34-6.3UMBotão giratórioCross-brand functional replacement
EatonDIL M9-104-6.3UMBotão giratórioCross-brand functional replacement
ChintNDM1-63/33004-6.3UMBotão giratórioEconomical domestic alternative
  1. Ambientes de aplicativos & Casos Típicos

5.1 Aplicativos recomendados

Automação Industrial: Protection for small pumps, fans and conveyor motors; compatible with PLC control circuits

Building Facilities: Control and protection for air conditioning fans, bombas de água, elevator door motors and fire linkage equipment

Comida & Indústria de Bebidas: Motor protection for packaging machines, filling machines and small mixers; meets hygiene requirements

Equipamento Médico: Safety protection for laboratory stirrers, centrifuges and small medical pumps

Agricultural Machinery: Protection for outdoor motors such as irrigation pumps, small harvesters and feed mixers

Centros de dados: Protection for precision air conditioner fans, cooling water pumps and UPS cooling fans

5.2 Non-recommended Applications

Partida frequente: Not applicable for equipment starting more than 10 vezes por hora. GV3 series or soft starters are recommended instead.

Heavy-duty start: Not suitable for motors with starting current over 8 vezes a corrente nominal. Additional overload protection is required.

Explosive hazardous areas: No explosion-proof certification. Do not use directly in Zone IIC explosive areas.

DC motors: The GV2 series is designed exclusively for AC motors. Use dedicated protective devices for DC motors.

5.3 Casos de aplicação típicos

Caso 1: Mixing System in Pharmaceutical Factory

Aplicativo: Sobrecarga, short-circuit and phase loss protection for 1.5kW reactor stirring motors

Configuração: GV2PM10C + LC1D12 Contactor + Control Buttons

Benefícios: Prevents motor burnout caused by agitator jamming; complies with GMP standards and trips rapidly for equipment protection during faults.

Caso 2: Air Conditioning System in Commercial Buildings

Aplicativo: Protection and control for 2.2kW fresh air handling units and water pump motors

Configuração: GV2PM10C + Building Automation System (BASE) + Temperature Sensors

Benefícios: Enables automatic start/stop of fans and pumps, protects motors against overload, reduces maintenance costs and improves energy efficiency by 12%.

Caso 3: Conveyors on Automated Production Lines

Aplicativo: Protection and control for 1.1kW small conveyor motors

Configuração: GV2PM10C + CLP + Emergency Stop Buttons

Benefícios: Avoids motor damage from conveyor jamming, works with emergency stop system for safe shutdown, and shortens Mean Time To Repair (MTTR) to within 3 minutos.

Caso 4: Aeration System in Wastewater Treatment Plant

Aplicativo: Protection and control for 2.2kW small aeration fans

Configuração: GV2PM10C + Liquid Level Sensors + Automatic Control Cabinet

Benefícios: Performs reliably in humid environments, prevents fan burnout from overload, realizes unattended automatic operation and cuts operational costs by 30%.

  1. Dicas de seleção & Regras de referência rápida

Selection Rhythm

Choose GV2PM10C,

Intervalo atual 4 to 6.3A,

Matches motors 1.5 to 2.2kW,

Operação do botão rotativo, IP20 rating,

35mm trilho DIN, 89mm largura,

High breaking capacity with thermal-magnetic protection,

Safeguards motors from overload and short circuit,

Reliable for industrial and building applications.

Regras de referência rápida

  1. Correspondência atual: 10 = 4-6.3A; 08 = 2.5-4A; 14 = 6.3-10A. Larger figure means wider current range.
  2. Modo de operação: PM = Rotary knob; ME = Push-button; LP = Magnetic-only type (short-circuit protection only).
  3. Combinação de poder: 4-6.3A corresponds to 1.5-2.2kW @ 400V. Approximate formula: Current × 0.5 ≈ Matched motor power (kW).
  4. Installation Features: 89mm largura, 35mm montagem em trilho DIN, Classificação de proteção IP20, ideal for installation inside control cabinets.
  5. Solução de problemas
Fenômeno de falhaPossíveis causasSoluções
Tropeços frequentesSetting current too lowTurn the rotary knob clockwise to increase current within 4-6.3A
Sobrecarga do motor / locked rotorCheck for overloading and eliminate jamming
Phase loss operationInspect three-phase power supply and repair broken wires or poor contacts
Falha ao fecharKnob not resetTurn the knob to OFF position then back to ON after tripping
Bloqueio mecânicoClear foreign objects or replace damaged components
Fiação erradaRecheck three-phase wiring and eliminate short circuits
Overheated contactsTerminais de fiação soltosRetighten terminals for good contact
Carga excessivaReduce load or replace with higher-rated circuit breaker if needed
Temperatura ambiente excessivamente altaImprove ventilation and keep temperature below 60°C
  1. Key Features Summary
  2. Proteção Abrangente: Thermal-magnetic trip unit provides delayed overload, instantaneous short-circuit and phase loss protection, compatível com IEC 60947-4-1.
  3. Wide Compatibility: 4-6.3A adjustable current range for 1.5-2.2kW three-phase motors; easy operation via rotary knob.
  4. Estrutura Compacta: Dimension 89mm×85mm×91mm with 35mm DIN rail mounting to save cabinet space.
  5. Alta confiabilidade: Ampla faixa de temperatura operacional (-20°C ~ +60°C) and IP20 rating for harsh industrial conditions.
  6. Fácil instalação & Manutenção: Standard interface for seamless matching with contactors; simple knob reset after faults.

Application Scenarios of Schneider GV2PM10C (4~6,3A)

This is a 3-pole rotary-knob motor circuit breaker with thermal-magnetic protection. It is suitable for 1.1~2.2kW three-phase asynchronous motors at 400V. Adopting DIN rail mounting, it integrates overload, short-circuit and phase loss protection, and is widely used in industrial, prédio, light industry and municipal fields.

  1. Main Application Scenarios

1.1 Industrial Automated Production Lines

Small belt conveyors and roller motors

Workshop auxiliary fans and dust extraction fans

Auxiliary power motors for manipulators and small positioners

Machine tool cooling pumps and lubrication pumps

Combined with PLC and relay circuits for local and remote control & proteção

1.2 AVAC & Building Electromechanical Systems

Terminal fans, fresh air fans and exhaust fans of central air conditioning

Small circulating water pumps and make-up water pumps for building water supply & drenagem

Cooling fans for computer room precision air conditioners

Auxiliary fans and door drive motors in elevator rooms

Fire exhaust fans and damper linkage motors (meeting fire power distribution standards)

1.3 Indústria Leve, Comida & Indústria de embalagens

Small mixers, blenders and feeding machines

Máquinas de embalagem, labelers and conveyor drive motors

Filling equipment and small roller conveyors

Ventilation fans and washing pumps for food workshops

(Compact body and qualified protection level, suitable for dusty and humid workshop conditions)

1.4 Tratamento de Água & Municipal Engineering

Small aeration fans, dosing pumps and reflux pumps in sewage treatment plants

Booster pumps for landscape pools and residential water supply

Small power motors inside on-site control boxes of pumping stations

Fans and water pumps supporting river and pipeline monitoring equipment

1.5 Laboratory & Medical Supporting Equipment

Laboratory stirrers, centrifuges and circulating water pumps

Exhaust and fresh air system motors for medical clean rooms

Medical water purifiers and small delivery pumps

(Sensitive protection effectively prevents equipment stalling and motor burnout)

1.6 Armazenagem, Logística & Supermarkets

Warehouse ventilation fans and dust removal equipment

Condenser fans and fresh air systems for supermarket refrigeration units

Motors for light sorting lines and small roller conveyors

1.7 Agricultural Machinery & Outdoor Light-duty Equipment

Small irrigation pumps and spray devices for farmland

Feed mixers and small agricultural ventilation equipment

(Wide temperature adaptability for outdoor simple electrical control boxes)

  1. Cenários não recomendados
  2. High-frequency starting equipment: Mais do que 10 starts per hour may cause false tripping. Dedicated starting solutions are recommended.
  3. Heavy-load motors with high starting current: Starting current far exceeds normal level; match with thermal relays and contactors additionally.
  4. Explosive hazardous areas: Without explosion-proof certification, not allowed for direct use in explosive zones.
  5. DC motors and high-power single-phase motors: Designed for three-phase AC motors only.
  6. Environments with long-term temperature above +60°C or strong corrosive gas: Protection accuracy and service life will be reduced.
  7. Common Matching Solutions for On-site Use
  8. Standard motor circuit: GV2PM10C + LC1D Contactor + Botões de pressão (Local start & parar)
  9. Automatic control circuit: GV2PM10C + Contator + CLP (Remote automatic control)
  10. Fire linkage circuit: GV2PM10C + Fire Module + Contator (Fire forced start / forced trip)

Anterior:

Deixe uma resposta

Deixe um recado