Inversor Schneider ATV71 HU75N4Z - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Inversor Schneider ATV71 HU75N4Z - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

inversor solar/elétrica/

Inversor Schneider ATV71 HU75N4Z

This is a Schneider Altivar 71 series inverter dedicated for fans and pumps. Below is technical data organized directly for selection/purchasing: Model Breakdown ATV71: Schneider high-performance general-purpose vector inverter series HU: Dedicated for HVAC fans & bombas (energy-saving algorithm, suitable for pump/fan loads) 75: Applicable motor power 7.5 kW N: Voltage class 3-phase 380~480 V, ...

  • Detalhes do produto

This is a Schneider Altivar 71 série inverter dedicated for fans and pumps. Below is technical data organized directly for selection/purchasing:

  1. Análise do modelo

ATV71: Schneider high-performance general-purpose vector inverter series

UH: Dedicated for HVAC fans & bombas (energy-saving algorithm, suitable for pump/fan loads)

75: Applicable motor power 7.5 kW

N: Voltage class 3-phase 380~480 V, 50/60 Hz

4: Modo de controle: Controle vetorial

Z: Versão padrão (filtro EMC integrado, braking unit, Chinese operation panel)

  1. Principais parâmetros técnicos
ItemValor
ModeloATV71HU75N4Z
Applicable Motor7.5 kW 3-phase asynchronous motor
Corrente nominal17 UM (typical at 380V)
Tensão de entrada3-phase AC 380~480 V
Modo de controleControle V/F + Controle vetorial sem sensor
Grau de ProteçãoIP20 (montado em gabinete)
Standard FeaturesFiltro EMC integrado, braking unit, Chinese panel
  1. Aplicativo & Seleção

Aplicações Típicas: Ventiladores centrais de ar condicionado, circulation pumps, water supply pumps, exhaust systems, AVAC

Load Characteristic: Optimized for quadratic torque loads, outstanding energy-saving effect

Same-series replacement/upgrade:

One size smaller: ATV71HU55N4Z (5.5 kW)

One size larger: ATV71HU11N4Z (11 kW)

General replacement: ATV340, ATV610 series in the same power range for fans and pumps

  1. Instalação & Manutenção

Instalação: Rail/screw mounting inside cabinet, air duct top inlet, bottom outlet

Resfriamento: Natural air cooling; cabinet space reserved for heat dissipation recommended

Common protections: Sobrecorrente, sobrecarga, sobretensão, subtensão, superaquecimento, proteção contra travamento

Complete ATV71 Series Model List & Replacement Options from Major Global Brands

  1. Full ATV71 Series Models (by Type & Poder)

ATV71 is a Schneider high-performance general-purpose vector inverter, covering 0.37kW~630kW. It is discontinued and officially upgraded to ATV930/ATV630/ATV340 series.

1.1 Regra de nomenclatura de modelo (Review)

`ATV71` + `Type Code` + `Power Code` + `Voltage Code` + `Control Code` + `Configuration Code`

Código de tipo: HU=HVAC fan/pump; HD=General heavy-duty; HC=Enhanced coating (harsh environment); H0=Basic version

Código de energia: por exemplo, 75=7,5kW, 11=11kW, 15=15kW, etc..

Voltage Code: N=3-phase 380~480V; M=3-phase 220~240V; Y=3-phase 500~690V

Control Code: 4=Vector control; 3=V/F control

Configuration Code: Z=Standard (EMC integrado, braking unit, Chinese panel); D=Enhanced; X=Basic

1.2 Common Model List (by Power Range)

PoderHVAC Fan/Pump Type (UH)General Heavy-Duty (alta definição)Enhanced Coating (HC)
0.75kWATV71HU075N4ZATV71HD075N4ZATV71HC075N4
1.5kWATV71HU15N4ZATV71HD15N4ZATV71HC15N4
2.2kWATV71HU22N4ZATV71HD22N4ZATV71HC22N4
3kWATV71HU30N4ZATV71HD30N4ZATV71HC30N4
4kWATV71HU40N4ZATV71HD40N4ZATV71HC40N4
5.5kWATV71HU55N4ZATV71HD55N4ZATV71HC55N4
7.5kWATV71HU75N4Z (your model)ATV71HD75N4ZATV71HC75N4
11kWATV71HU11N4ZATV71HD11N4ZATV71HC11N4
15kWATV71HU15N4ZATV71HD15N4ZATV71HC15N4
18.5kWATV71HU18N4ZATV71HD18N4ZATV71HC18N4
22kWATV71HU22N4ZATV71HD22N4ZATV71HC22N4
30kWATV71HU30N4ZATV71HD30N4ZATV71HC30N4
37kWATV71HU37N4ZATV71HD37N4ZATV71HC37N4
45kWATV71HU45N4ZATV71HD45N4ZATV71HC45N4
55kWATV71HU55N4ZATV71HD55N4ZATV71HC55N4
75kWATV71HU75N4ZATV71HD75N4ZATV71HC75N4
90kWATV71HU90N4ZATV71HD90N4ZATV71HC90N4
630kWATV71HD63N4DATV71HC63N4D
  1. Cross-Reference Table for Major Global Brands (7.5kW Base)

2.1 Schneider Official Upgraded Models (Primeira escolha)

Modelo originalSubstituição recomendadaCaracterísticas
ATV71HU75N4ZATV930HU75N4Controle vetorial de alto desempenho, compatible with old parameters, EcoStruxure smart architecture
ATV71HU75N4ZATV630HU75N4Optimized for fans & bombas, upgraded energy-saving algorithm
ATV71HU75N4ZATV340HU75N4Econômico, suitable for basic HVAC applications

2.2 Equivalent Models from Other International Brands

MarcaSérieModelo de substituiçãoModo de controleSuitable Voltage
SiemensSINAMICS G1206SL3224-0BE27-5UA0Controle vetorial3-fase 380~480V
SiemensSINAMICS V206SL3210-5BE27-5UV0V/F + Vector3-fase 380~480V
ABBACS580ACS580-01-145A-4Controle direto de torque3-fase 380~480V
ABBACS380ACS380-040S-07A5-1Controle vetorial3-fase 380~480V
MitsubishiFR-A840FR-A840-00163-2-60Controle vetorial3-fase 380~480V
MitsubishiFR-F840FR-F840-00163-2-60Controle V/F3-fase 380~480V
RockwellPowerFlex 52525B-D017N104Controle vetorial3-fase 380~480V
DanfossVLT AutomationDriveFC302P11KT4E20H2BXCDControle vetorial3-fase 380~480V
FujiFRENIC-AceFRN0016E2S-4CControle vetorial3-fase 380~480V
YaskawaGA700CIMR-GA2A0018ABAControle vetorial3-fase 380~480V
  1. Key Points for Replacement Selection
  2. Combinação de poder: Rated current of replacement ≥ 17A of original ATV71HU75N4Z (typical at 380V)
  3. Funções de controle: For fan/pump applications, prioritize models with PID, sleep/wake-up, multi-pump control
  4. Compatibilidade de instalação: Match dimensions, recortar, cooling requirements with original equipment
  5. Migração de parâmetros: ATV930/630 support direct parameter import from ATV71, reducing commissioning cost
  6. Capacidade de sobrecarga: ATV71: 150% overload for 60s; verify equivalent rating when replacing
  7. Recomendações de seleção

Prioritize Schneider official upgraded models (ATV930/630): best compatibility, full technical support

HVAC fan/pump applications: Choose HU type first, then brand-specific HVAC-optimized drives (por exemplo, ABB ACS580-01, Siemens G120X)

Aplicações industriais gerais: HD type or general vector inverters; verify braking unit, EMC filter options

Anterior:

Próximo:

Deixe uma resposta