Schneider LC1D256BL Contactor - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

Schneider LC1D256BL Contactor - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

contator/

Schneider LC1D256BL Contactor

Model Code Explanation Code Segment Meaning Detailed Description LC1 Product series identifier Basic code for Schneider TeSys contactors D Series code TeSys Deca series, high-performance full-range industrial contactors 25 Rated current 25A (rated operational current under AC-3 utilization category) 6 Coil characteristic Low-power consumption coil (<2.4C), energy-saving design B Coil voltage 24V L Coil type ...

  • Detalhes do produto

Explicação do código do modelo

Segmento de códigoSignificadoDescrição detalhada
LC1Identificador da série do produtoBasic code for Schneider TeSys contactors
DCódigo da sérieTeSys Deca series, high-performance full-range industrial contactors
25Corrente nominal25UM (rated operational current under AC-3 utilization category)
6Coil characteristicLow-power consumption coil (<2.4C), projeto de economia de energia
BTensão da bobina24V
euTipo de bobinaBobina CC
Descrição completaThree-pole contactor of Schneider TeSys Deca series, corrente nominal 25A, 24VDC low-power coil, ring terminal connection, 1Contatos auxiliares NO+1NC
  1. Principais Especificações Técnicas
CategoriaDados TécnicosObservações
Parâmetros Básicos
Tipo de produto3-pole non-reversible contactor3 main NO contacts
Corrente nominal (AC-3)25A @ 400VFor controlling 11kW three-phase motors
Corrente nominal (AC-1)40A @ 400VPara cargas resistivas
Tensão operacional nominalMáx.. 690VAC / Máx.. 300CCV
Especificação da bobina24CCV, Baixo consumo de energia (≤2.4W)Pull-in voltage: 19.2-30CCV
Mecânico & Resistência Elétrica
Vida Mecânica15,000,000 ciclos (sem carga)
Vida Elétrica (AC-3)1,600,000 ciclos (with load)
Physical Features
Tipo de montagemMontagem em trilho DIN padrão de 35 mm
Tipo de conexãoRing-lugsFor firm wiring
Contatos Auxiliares1NÃO+1NC (padrão)Expansível
Dimensões (milímetros)Aprox.. 45×85×101Tamanho compacto, economiza espaço no armário
Certificações & PadrõesCEI 60947-4-1, EM 60947-4-1, Compatível com RoHSComply with international industrial standards
Ambiente Operacional
Temperatura operacional-25°C ~ +70°CAmpla faixa de temperatura para ambientes industriais agressivos
Temperatura de armazenamento-40°C ~ +85°C
Proteção de entradaIP20 (unidade principal)Use with qualified protective enclosures
  1. Lista completa de modelos (LC1D Series, 25A Range)
ModeloTensão da bobinaTipo de bobinaConsumo de energia da bobinaContatos AuxiliaresNúmero do pedido de referência.
LC1D256BL24CCVCCBaixo consumo de energia (<2.4C)1NÃO+1NCLC1D256BL
LC1D256B724VACACBaixo consumo de energia1NÃO+1NCLC1D256B7
LC1D2501BL24CCVCCStandard power1NÃO+1NCLC1D2501BL
LC1D2501B724VACACStandard power1NÃO+1NCLC1D2501B7
LC1D2510BL24CCVCCStandard power1NC+1NOLC1D2510BL
LC1D2510B724VACACStandard power1NC+1NOLC1D2510B7
LC1D25BD24CCVCCStandard power1NÃO+1NCLC1D25BD
LC1D25M7220VACACStandard power1NÃO+1NCLC1D25M7
LC1D25Q7380VACACStandard power1NÃO+1NCLC1D25Q7
LC1DT256BL24CCVCCBaixo consumo de energia1NÃO+1NC (4-pólo)LC1DT256BL
  1. Cross-brand & Old/New Model Replacement List

4.1 In-brand Replacement (Schneider)

Modelo originalModelo de substituiçãoDescrição
LC1D25BDLC1D256BLUpgraded to low-power coil, 24VDC retained with improved performance
LC1D25B7LC1D256B7Low-power AC coil version
LC1D2500BLLC1D256BLOptimized auxiliary contacts (1NO+1NC replaces 0NO+0NC)

4.2 Cross-brand Replacement

Original BrandModelo originalEquivalente de SchneiderNível de correspondênciaObservações
ABBA26-30-10LC1D256BL★★★★★3-pole 25A, 24Bobina V, identical specifications
Siemens3RT6026-1AN20LC1D256BL★★★★☆25UM, 24CCV, mesma configuração de contato auxiliar
OmronGMC-25LC1D256BL★★★★☆3-pole 25A, 24CCV, equivalent mechanical life
MitsubishiS-N25LC1D256BL★★★★☆3-pole 25A, low-power 24VDC coil
  1. Ambiente de aplicação & Casos da Indústria

5.1 Aplicativos recomendados

Automação Industrial: Control of three-phase asynchronous motors (fãs, bombas de água, compressores, transportadores)

Sistemas HVAC: Air conditioning compressors and ventilation systems

Elétrica predial: Automação predial, lighting systems and fire-fighting equipment

Indústria Energética: Power generation equipment, power distribution systems and renewable energy facilities

Tratamento de Água: Water pump control and wastewater treatment equipment

Marinho & Ferrovia: Transportation industry requiring special certifications (LC1D series advantages)

5.2 Aplicativos não recomendados

High-frequency switching: Sobre 1200 operações por hora (Select LC1Q / LC1R series instead)

High altitude: Elevation over 2000m (Derate load or use special models)

Corrosive environments: Direct exposure to acid, alkali and salt mist (Additional protection required)

Áreas à prova de explosão: Special explosion-proof certified models are mandatory

5.3 Casos de aplicação típicos

  1. Automobile Manufacturing Plant

Used for motor control of stamping production lines. After replacement, breaking time is reduced by 30%, failure rate drops by 50%, maintenance time is shortened from 2 horas para 30 minutos, and annual maintenance cost is cut by about 200,000 RMB.

  1. Comida & Indústria de Bebidas

Applied to three-phase motors of filling lines. Thanks to 2.4W low power consumption, each contactor saves approximately 18 kWh per year under 24-hour continuous operation. A factory with 100 units saves 1,800 kWh annually.

  1. Centro de dados

Controls air conditioning compressors and ventilation fans. The 24VDC low-power coil ensures stable operation under UPS power supply, reduces battery load and extends backup duration.

  1. Diretrizes de seleção & Regras de referência rápida

Quick Selection Tips

This is a 3-pole 25A contactor with 24VDC low-power coil and ring terminals. Equipped with 1NO+1NC auxiliary contacts, it features energy efficiency, high reliability and long service life, ideal for motors, bombas de água e compressores.

Regras de referência rápida

  1. Correspondência atual: 25A under AC-3 for 11kW three-phase motors; 40A capacity for resistive loads under AC-1.
  2. Coil Identification: Suffix BL = 24VDC low power; B7 = 24VAC low power; BD = 24VDC standard power.
  3. Contatos Auxiliares: Standard 1NO+1NC. Models with suffix 01 ou 10 for alternative contact configurations.
  4. Instalação: Montagem em trilho DIN padrão de 35 mm; ring terminals ensure reliable connection.
  5. Economia de energia: Low-power coil (≤2.4W) saves 70% energy compared with standard coil (aprox.. 8C), perfect for long-term operation.
  6. Falhas Comuns & Solução de problemas
Fenômeno de falhaPossíveis causasSoluções
O contator não consegue puxarInsufficient coil voltage / Fiação erradaCheck power voltage (19.2-30CCV) e fiação
Bobina queimadaSobretensão / Reverse polarityConfirm 24VDC polarity; install overvoltage protection
Overheated contactsSobrecarga / Fiação soltaCheck load current and retighten terminals
Welded contactsSobrecarga / Curto-circuitoInspect circuit protection devices and replace contact assembly
Ruído excessivoDirty core contact surfaceClean core surface and check short-circuit ring
  1. Key Ordering Information

Modelo Padrão: LC1D256BL

Modelos Alternativos: LC1D25BD (standard power version), LC1D256B7 (24VAC low-power version)

Acessórios compatíveis:

Auxiliary contact blocks: Série LADN (por exemplo. LADN20C: 2NÃO; LADN02C: 2NC)

Overload relays: Série LRD (por exemplo. LRD08C: 6-10UM, matches 25A contactor)

Mounting base: Optional separate base

Application Scenarios for LC1D256BL

Core features: 3-pole 25A, 24VDC low-power coil, longa vida útil, standard DIN rail mounting, 1Contatos auxiliares NO+1NC, forte desempenho anti-interferência.

  1. Cenários de aplicação recomendados (Principais aplicações)

Featured with 24VDC low-power DC coil, this model perfectly matches standard industrial DC control circuits. Its 25A rating is suitable for three-phase motors up to 11kW and resistive loads up to 40A, serving as a mainstream component for automatic control cabinets.

1.1 Industrial Automation Equipment (Aplicativo principal)

Equipamento aplicável

PLC/DCS control cabinets, pequenas máquinas-ferramentas, manipulator auxiliary mechanisms, inverter-driven fans, small drive motors, test and inspection equipment.

Vantagens

24VDC is the mainstream control voltage for industrial control systems, no extra power converter required.

DC coil provides strong EMC performance, avoiding misoperation caused by inverters and servos.

Baixo consumo de energia (≤2.4W) generates little heat during continuous power-on, adequado para 24/7 standby equipment.

1.2 AVAC & Air Ventilation Systems

Equipamento aplicável

Interior & outdoor unit fans of central air conditioners, condensate pumps, cooling tower fans, fresh air handling units, damper drive motors, machine room exhaust fans.

Vantagens

HVAC rooms widely adopt 24VDC automatic control circuits for high compatibility.

Low power design reduces energy consumption and cabinet temperature for year-round continuous operation.

Faixa de temperatura operacional: -25°C ~ +70°C, adapts to drastic temperature changes in machine rooms.

1.3 Elétrica predial & Fire Emergency Systems

Equipamento aplicável

Domestic water pumps, basement exhaust fans, fire smoke exhaust fans, fire roller shutter motors, centralized emergency lighting circuits (cargas resistivas).

Vantagens

Standard 24VDC for fire emergency circuits, directly powered by UPS/emergency batteries for normal operation during power failure.

Built-in 1NO+1NC auxiliary contacts transmit operation/fault signals to fire alarm hosts and building monitoring systems.

40A load capacity under AC-1 for multi-circuit lighting control.

1.4 Indústria de tratamento de água (Sewage / Purified Water / Circulating Water)

Equipamento aplicável

Circulating water pumps, dosing metering pumps, aeration fans, small agitator motors, ventilation equipment for water treatment workshops.

Vantagens

Almost all automatic control systems for water treatment use 24VDC.

IP20 protection rating adapts to slightly humid indoor machine rooms.

Satisfactory electrical endurance for frequent start-stop operation with low failure rate.

1.5 Nova Energia, VP & Energy Storage Cabinets

Equipamento aplicável

Cooling fans for PV boxes, temperature control pumps for battery compartments, ventilation motors of energy storage cabinets, small auxiliary inverter loads.

Vantagens

PV and energy storage systems are DC-powered inherently; no inverter needed for 24VDC coil.

Ultra-low coil power avoids extra consumption of backup battery power and extends backup time.

No AC humming for DC coil, ideal for quiet energy storage rooms.

1.6 Logística, Armazenagem & Conveyor Lines

Equipamento aplicável

Transportadores de correia, roller sorting lines, small elevators, warehouse ventilation fans.

Vantagens

Mechanical and electrical endurance meets frequent regular start-stop for long-running production lines.

Auxiliary contacts realize interlock, chain control and sequence start to ensure safety logic of production lines.

1.7 Comida, Embalagem & Light Industrial Equipment

Equipamento aplicável

Conveyors of packaging machines, auxiliary motors of filling lines, dehumidifiers and ventilation fans for workshops.

Vantagens

Suitable for clean indoor workshops without heavy corrosion; standard rail mounting facilitates standardized cabinet wiring.

Compact structure saves cabinet space, a standard OEM component for complete machines.

  1. Não recomendado / Cenários Proibidos (Riscos & Alternativas)

2.1 High-frequency Start-Stop (Sobre 1200 cycles per hour)

Risco: Excessive switching frequency causes rapid contact ablation, welding and shortened service life.

Alternativa: Schneider LC1R / LC1R series high-frequency contactors.

2.2 Altitude acima de 2.000 m

Risco: Thin air degrades arc extinction capability, leading to arcing and reduced insulation performance.

Recomendação: Use special high-altitude contactors or derate the load by over 30%.

2.3 Severe Corrosion, Salt Spray & Poeira Pesada (Chemical Plants, Coastal Open Areas, Minas)

Risco: IP20 rating cannot protect coil, terminals and contacts from acid, alkali, salt mist and dust erosion.

Exigência: Bare installation is forbidden. Use sealed enclosures of IP54 or higher; select anti-corrosion models for chemical environments.

2.4 Direct Outdoor Installation without Protection

Risco: Rain, sunlight and condensation lead to coil short circuit and contact oxidation.

Mandatory Requirement: Install inside distribution cabinets or control enclosures with IP54 or higher protection.

2.5 High-power Pure DC Main Circuit Loads

Risco: Designed mainly for AC loads with poor DC breaking capacity; high DC loads easily cause contact welding.

Alternativa: Schneider LP1D dedicated DC contactors.

2.6 AC220V / AC380V Control Circuits

Risco: 24VDC coil will burn out instantly if connected to AC power.

Alternative AC coil models:

24VAC: LC1D256B7

220VAC: LC1D25M7

380VAC: LC1D25Q7

2.7 Control Three-phase 380V Motors over 11kW (AC-3)

Risco: Rated 25A under AC-3 corresponds to 11kW motor; overload results in overheating and burnt contacts.

Alternativa: Upgrade to higher current models such as LC1D32 series.

  1. Notes for Marginal Operating Conditions (Usable with Protection Measures)
  2. Basements & Humid Machine Rooms

The product is applicable. Install dehumidifiers inside control cabinets to prevent condensation inside the contactor.

  1. Ambient Temperature near Limits (-25°C / +70°C)

Derate the load by 10% and avoid long-term full-load operation.

  1. Coil Wiring Length over 10m

Voltage drop occurs on 24VDC lines. Ensure terminal voltage of the contactor coil is no lower than 19.2V (minimum pull-in voltage).

  1. Control Inductive Loads such as Motors

Equip with surge suppressors (Schneider LADRC series) to absorb back EMF and protect the coil.

  1. Scenario Summary

✅ Preferred Applications: Indoor control cabinets, 24VDC control systems, three-phase motors up to 11kW, 24/7 continuous-operation equipment (Automação, AVAC, Fire Protection, Tratamento de Água, Energy Storage).

❌ Evite: High-frequency switching, alta altitude, unprotected outdoor areas, heavily corrosive environments, high-power DC main circuits, AC control power supply.

Anterior:

Deixe uma resposta

Deixe um recado