Schneider RXZE2M114M 14-pin Relay Socket - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Schneider RXZE2M114M 14-pin Relay Socket - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

elétrica/

Schneider RXZE2M114M 14-pin Relay Socket

Schneider RXZE2M114M is a 14-pin mixed-type relay socket, specially designed for RXM2/RXM4 series miniature intermediate relays. It features 10A rated current, IP20 protection degree and wide operating temperature range, suitable for various industrial control applications. Its mixed terminal layout ensures flexible wiring, and dual mounting modes fit different control cabinet designs. Approved with CE, UL, ...

  • Detalhes do produto

Schneider RXZE2M114M is a 14-pin mixed-type relay socket, specially designed for RXM2/RXM4 series miniature intermediate relays. It features 10A rated current, IP20 protection degree and wide operating temperature range, suitable for various industrial control applications. Its mixed terminal layout ensures flexible wiring, and dual mounting modes fit different control cabinet designs. Approved with CE, UL, CSA e outras certificações internacionais, it can be shipped as ordinary goods by air without special formalities.

  1. Definição de código de modelo
Segmento de códigoSignificadoDescrição
RXZSérie de produtosZelio Relay series relay sockets
E2Código da série2nd-generation standard socket, compatible with 2-pole & 4-pole RXM relays
MTerminal ArrangementMixed layout, coil and contact terminals arranged alternately
114Configuração de contato14 alfinetes, fits relays with 4 change-over contacts (4CO/4PDT) ou 2 change-over contacts (2CO/2PDT)
MRegional StandardCompliant with RIS standard; differs from RXZE2M114 (SCR standard) in partial certification details

Full Product Name: Schneider Harmony Zelio RXZE2M114M Mixed-type 14-pin Relay Socket, compatible with RXM2/RXM4 relays, screw terminal connection, Montagem em trilho DIN

  1. Especificações Técnicas Principais
CategoriaEspecificaçõesObservações
Parâmetros Básicos
Tipo de produtoMixed-type relay socketMixed layout of coil and contact terminals
Compatible RelaysRXM2 (2CO, 8-alfinete), RXM4 (4CO, 14-alfinete), REXL seriesCompatible with standard Schneider Zelio relays
Pin ShapeFlat typeEnsures stable plug-in connection
Wiring TypeM3 screw terminalsTightening torque ≤1 N·m
Parâmetros Elétricos
Tensão operacional nominal (Ué)≤250V AC/DCApplicable to most industrial control circuits
Conventional Free-air Thermal Current (É)10UMContinuous rated working current
Resistência Dielétrica2500VCompatível com IEC 61984
Grau de ProteçãoIP20Finger-proof and dust-proof
Parâmetros Mecânicos
Método de montagem35mm standard DIN rail clip-on / panel screw mountingDual installation options
Largura27milímetrosTamanho compacto, economia de espaço
Peso líquido0.056kgLightweight design
Fios AplicáveisSolid wire: 0.5~2,5 mm² (AWG20~14)Covers various wiring requirements
Stranded wire with ferrule: 0.25~2,5 mm² (AWG22~14)
Twin solid wire: 0.5~1.5mm² (AWG20~16)
Twin stranded wire with ferrule: 0.25~1mm² (AWG22~17)
Parâmetros Ambientais
Temperatura operacional-40°C ~ +55°CWide temperature range for harsh industrial environments
Temperatura de armazenamento-40°C ~ +85°CSuitable for transportation and storage
CertificaçõesCE, UL, CSA, Lloyd’sMeets major international safety standards
Ordering Info
Número da peçaRXZE2M114MUnique product model
Minimum Order Qty10 peçasStandard packing quantity
Modelo AlternativoRXZE2M114 (SCR standard)Same function, different certification standards
  1. Falhas Comuns & Maintenance Solutions

3.1 Solução de problemas

Fenômeno de falhaPossíveis causasSoluções
Relay cannot be inserted/removed1. Deformed socket pins1. Straighten pins gently with tweezers
2. Oxidized/dirty relay pins2. Clean pins with anhydrous alcohol
3. Distorted socket caused by over-tight installation3. Adjust installation tightness and reinstall
Mau contato / signal interruption1. Loose wiring terminals1. Retighten terminals within 1 N*m torque
2. Oxidized/burned contacts2. Polish contacts gently with metallographic sandpaper
3. Deformed internal terminals3. Inspect and replace defective socket
Abnormal overheating1. Overload operation over 10A1. Replace higher-capacity socket or split load
2. Large contact resistance at terminals2. Re-crimp wires for better contact
3. Excessively high ambient temperature3. Improve ventilation and lower temperature
Reduced insulation performance1. Dust and oil accumulation1. Clean socket surface regularly
2. Insulation aging under long-term high temperature2. Replace aged sockets timely
3. Chemical corrosion3. Use anti-corrosion sockets or protective covers

3.2 Daily Maintenance Recommendations

  1. Inspeção Regular: Check terminal tightness every 3 meses
  2. Limpeza: Remove dust with compressed air every 6 meses, wipe surface with anhydrous alcohol if needed
  3. Preventive Replacement: Replace sockets every 2-3 years in high-temperature, high-humidity or corrosive environments
  4. Regras de instalação: Avoid mechanical shock and vibration; ensure full fitting between socket and relay; keep ≥5mm gap between adjacent sockets for heat dissipation
  5. Dica de seleção: Reserva 20% current margin according to resistive/inductive loads to avoid overload
  6. Full RXZE2 Series Model List
ModeloDisposição dos TerminaisPin CountRelé compatívelCaracterísticasAplicativo
RXZE2M114MMixed14RXM2(2CO), RXM4(4CO)RIS standard, terminais de parafusoControle industrial geral, flexible wiring
RXZE2M114Mixed14RXM2(2CO), RXM4(4CO)SCR standard, terminais de parafusoSame function, different certifications
RXZE2S114MSeparated14RXM4(4CO)Separated coil & contact terminalsLogic control circuit, anti-interferência
RXZE2S111MSeparated11RXM3(3CO)For 3-pole relaysSpecial control such as star-delta starting
RXZE2S108MSeparated8RXM2(2CO)For 2-pole relaysCompact control circuits
RXZE2M108MMixed8RXM2(2CO)Mixed 8-pin designCompact control boxes
  1. Cross-brand Comparison
MarcaModeloMontagemPreço(USD)Compatibilidade
SchneiderRXZE2M114MDIN Rail/Panel6.23RXM2/RXM4 series
OmronPYFZ-014Trilho DIN5.8Partial fit for RXM, fits MY4
Siemens3RH2911-1FA22Trilho DIN7.5Limited compatibility with 3RT series
ABBCR-M14STrilho DIN6.9Partial fit for CR-M series
IDECSH4B-05BTrilho DIN6.1Good mechanical compatibility with RH4B
FênixPLC-RSC-24DC/21-21Trilho DIN8.2Low cross-brand compatibility

Replacement Suggestion

  1. Compatibilidade total: Adopt original Schneider RXZE2M114 / RXZE2M114M
  2. Cost-effective alternative: Omron PYFZ-014, IDEC SH4B-05B
  3. Observação: Verify terminal wiring diagrams before replacement to avoid wiring errors
  4. Air Shipment Compliance & Certificações

6.1 Shipment Regulation

Conclusão: Pure electromechanical component, no built-in lithium battery or super capacitor, non-dangerous goods

Shipping Class: Ordinary cargo, no UN38.3 test or dangerous goods packaging required

Packaging Advice: Pack individually with anti-static bag; use hard carton for anti-deformation; separate bulk goods with partition boards

6.2 Main Certifications

CertificatePadrãoStatusApplicable Area
CEEN/IEC 61984CompliantEU & EEA
ULUL 508CompliantAmérica do Norte
CSACSA C22.2 No.14CompliantCanadá
Lloyd’sMarine StandardCompliantMarinho & engenharia offshore
RoHS2011/65/EUCompliantGlobal environmental compliance

6.3 Certification Inquiry Way

  1. Search RXZE2M114M on official Schneider website
  2. Check certification marks on product labels and packages
  3. Obtain full certification documents via Schneider technical support
  4. Aplicativo & Guia de seleção

7.1 Cenários Aplicáveis

Automação industrial: PLC output expansion, válvula solenóide & contactor control

Controle motor: Início estrela-triângulo, forward/reverse rotation, proteção contra sobrecarga

Elétrica predial: Iluminação, air conditioning and fire linkage control

Marine engineering: Marine electrical control with Lloyd’s approval

Controle de processo: Sensor signal amplification, actuator drive control

7.2 Unrecommended Scenarios

Severe high-vibration working conditions without shockproof measures

Strong corrosive environment such as chemical plants and salt fog areas

Working current exceeding 10A rated value

High-frequency switching over 10 vezes por segundo

7.3 Etapas de seleção

  1. Confirm relay model: RXM2 (2CO 8-pin) / RXM4 (4CO 14-pin)
  2. Choose socket type: Mixed (M) / Separated (S)
  3. Confirm pin quantity: 8-pin /14-pin
  4. Select standard: RIS (M suffix) / SCR standard
  5. Confirm mounting method: DIN rail or panel mounting

Anterior:

Deixe uma resposta

Deixe um recado