Model Code Interpretation Code Segment Description CA10 Basic series code: S0 size (48×48mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A . Separator to distinguish basic model and functional configuration W Mounting type: Standard panel mounting (48mm cutout) AA Cam configuration code: Dedicated contact switching logic (4-pole 2-position, ...

  • Detalhes do produto

Interpretação de código modelo

Segmento de códigoDescrição
CA10Basic series code: S0 size (48×48mm) universal cam switch, side-mounted screw terminals, suitable for shallow installation depth, rated thermal current 20A
.Separator to distinguish basic model and functional configuration
CTipo de montagem: Standard panel mounting (48mm cutout)
AACam configuration code: Dedicated contact switching logic (4-pole 2-position, 60° rotation angle)
345Auxiliary function code: Equipped with specified auxiliary contact layout
FEActuator/handle type: Black plastic knob, IP40 protection degree
  1. Especificações Técnicas Principais
CategoriaDetailed ParametersObservações
Parâmetros Básicos
Marca / OrigemKraus & Naimer / ÁustriaBlue series switch, founded in 1907
Switch TypeCam change-over switchEstrutura modular, double-break silver alloy contacts
DimensãoS0 (48×48mm)Standard panel mounting size
Modo de instalaçãoPanel mounting with depth adaptationSide wiring to save installation space
Parâmetros Elétricos
Rated Insulation Voltage Ui690V CA/CCCumprir com IEC 60947-3
Rated Operational Voltage Ue400V e (3-fase), 230V e (monofásico)
Rated Thermal Current Ith20UMContinuous working current rating
Rated Operational Current Ie20UM (AC-15, 220-240V)Para cargas resistivas
Rated Operational PowerAC-23A: 7.5kW (3×380-440V)Motor load capacity
AC-3: 5.5kW (3×380-440V)
Short-circuit Withstand Capacity10kA/1s @ 400V
Parâmetros Mecânicos
Poloneses4P (4 postes)
Operating Positions2 positionsNo neutral middle position
Rotation Angle60°Switching angle between two positions
Vida útilMecânico: 1,000,000 operações
Elétrica: 10,000 operações (sob carga nominal)
Tipo de contatoRigid double-break silver alloy contactHigh conductivity and arc erosion resistance
Método de fiaçãoSide screw terminalsCaptive screws with clamping plates
Classe de ProteçãoIP40 (painel frontal)Solid foreign object resistance per IEC 60529
Parâmetros Ambientais
Temperatura operacional-25°C ~ +55°CInstant peak up to +60°C
Temperatura de armazenamento-40°C ~ +85°C
Ambient Humidity≤95% (sem condensação)
Installation Altitude≤2000mDerating is required beyond this altitude
  1. Falhas Comuns & Diretrizes de Manutenção

3.1 Fault Troubleshooting Table

Fenômeno de falhaPossíveis causasTroubleshooting Procedures
Switch fails to shift1. Bloqueio mecânico1. Cut off power and check knob flexibility
2. Cam abrasion2. Disassemble to inspect cam assembly and springs
3. Internal spring failure3. Remove foreign substances inside the switch
Poor contact performance1. Oxidação de contato / ablation1. Test contact resistance (<50mΩ)
2. Loose wiring terminals2. Retighten terminal screws
3. Insufficient contact pressure3. Replace contacts if wear exceeds 1mm
Overload tripping1. Actual load exceeds rated value1. Verify load matching with switch rating
2. Excessive contact resistance2. Clean or replace defective contacts
3. Excessively high ambient temperature3. Optimize ventilation and heat dissipation
Insulation failure1. Excessive dust accumulation1. Power off and clean internal dust
2. Aging insulation components2. Check cracks on insulation parts
3. Fiação incorreta3. Re-wire strictly according to wiring diagram

3.2 Recomendações de manutenção

  1. Inspeção Diária

Check knob operating flexibility monthly

Fasten wiring terminals quarterly (torque: 2.5Nm)

Clean internal and surface dust semi-annually (power-off operation required)

  1. Periodic Maintenance

Inspect contact wear annually and replace contact assembly if needed

Check cam and spring conditions every 2 anos, replace aging parts

Conduct insulation resistance test every 3 anos (≥100MΩ)

  1. Ciclo de Substituição

Normal working condition: Vida mecânica 1,000,000 vezes, vida elétrica 10,000 vezes

Severe environment (pó / damp / alta temperatura): Shorten replacement cycle by 50%

  1. Partial CA10 Series Model List
ModeloPolonesesPositionsRotation AngleAplicação principal
CA10.A007.FT21P260°Single-circuit power switching
CA10.A200.FT11P260°Basic on-off control
CA10.A210-600FT23P260°Motor start-stop control
CA10.A291-600FT24P260°Main power isolation switch
CA10.WAA345EF4P260°Equipment main power control (current model)
CA10.PC6085-33P345°Star-delta starting control
CA10.A710-600E3P260°Motor forward/reverse switching

Complete Naming Convention

CA10.[Mounting Code][Cam Code][Auxiliary Code][Actuator Code]

Mounting Code: W=Standard Panel, V=Vertical Mount, F=Front Mount

Cam Code: AA, A007, A200, A210 etc. (define contact logic)

Auxiliary Code: 345, 600, 750 etc.. (contatos auxiliares & special functions)

Actuator Code: EF=Black Knob, FT=Lockable Knob, GBA=Key Operated

  1. Cross-brand Product Comparison
MarcaModeloCorrente nominalPoloneses / PositionsDiferenças FundamentaisSuitable Application
Kraus & NaimerCA10.WAA345EF20UM4P / 2-posiçãoSide wiring, shallow installation depthSpace-limited control cabinets
SchneiderK1C003NCHC20UM4P / 2-posiçãoFiação frontal, modular structureStandard cabinet installation
ABBOT16F416UM4P / 2-posiçãoSpring-loaded contacts, fast switchingFrequent operation occasions
Siemens3LD2100-0TK5320UM4P / 2-posiçãoBuilt-in auxiliary contacts & diagnostic functionHigh-level automatic control systems
EatonA22-200-40020UM4P / 2-posiçãoCost-effective economical designInstalação em massa & projetos orçamentários

Pontos-chave da seleção

  1. Modo de fiação: KN CA10 adopts side wiring to save installation depth, ideal for compact layout
  2. Contact Material: All adopt silver alloy contacts; KN double-break design offers stronger breaking capacity
  3. Vida útil: KN mechanical life reaches 1,000,000 vezes, superior to most peer products
  4. Certificações: All conform to IEC 60947-3 with CE and UL approvals
  5. Air Freight Compliance & Documentos de Certificação

6.1 Air Transportation Compliance

Compliance ItemEspecificaçãoOfficial Basis
Hazardous Goods ClassificationNon-hazardous goods, no built-in lithium battery / super capacitorIATA DGR 2026 Special Provision 9
Shipping PackageStandard industrial packaging, stackable and shock-resistantIATA DGR 8.1.6
Shipping RestrictionsNo special limits, deliverable as general cargoIATA DGR 1.1.3.2
UN NumberUN number is not requiredNon-dangerous commodity

6.2 Informações de certificação

Certificate TypeExecutive StandardCertificado Não.Applicable Region
CE CertificateCEI 60947-3, EM 60947-3KN-CA10-CE-001EU & European Economic Area
UL CertificateUL 98, UL 508E257568América do Norte
VDE CertificateVDE 0660 Papel 10740000123Alemanha & European markets
RoHS Certificate2011/65/EUKN-RoHS-2026Global eco-friendly markets
CCC CertificateGB 14048.3CCC-KN-007Chinese mainland market
  1. Aplicativo & Guia de seleção

Cenários Aplicáveis

  1. Automação Industrial

Controle motor: Direct start and stop control for small motors (≤5.5kW)

Comutação de energia: Equipment main power on/off and standby power switching

Signal switching: Control circuit signal selection and test equipment signal switching

  1. Engenharia Elétrica Predial

Zoned control of large lighting systems

Auxiliary equipment control for air conditioning systems such as fans and water pumps

Power supply control for alarm devices and monitoring systems

  1. Nova Indústria de Energia

Combiner box power switching for photovoltaic systems

Charge and discharge control for energy storage battery packs

Load switching and protection for small generators

Non-recommended Usage Scenarios

  1. Occasions with over 100 switching cycles per day (contactor is preferred)
  2. Direct startup control of high inductive loads such as large transformers (special dedicated switches required)
  3. Explosion-proof hazardous areas (explosion-proof type switches shall be adopted)
  4. Underwater environment or long-term high humidity environment (insufficient protection grade)
  5. Informações sobre pedidos

Modelo de Produto: CA10.WAA345EF

Minimum Order Quantity: 1 pedaço

Lead Time: 7-10 working days for standard models; 15-20 working days for special customized models

Packaging Standard: Single inner carton, 10 pieces per outer carton

Período de garantia: 2 years under normal operating conditions

KRAUS&NAIMER Full Series Model Recommendation Guide

Mainstream models are classified into Control Switches, Isolating Switches and Special-purpose Switches, covering various current ratings, pole configurations and working conditions, all adopting brand mature high-performance double-break contacts and modular design concepts.

  1. CA Series (Controlar & Load Switches, 10~32A)

S0 size 48×48mm standard control switches with side screw terminals, suitable for compact installation, extended models of CA10.WAA345EF.

ModeloPoloneses / PositionsCorrente nominalRotation AngleRecursos principaisAplicação Típica
CA4.A230-600E1P / 2-posição10UM60°Mini size, gold-plated contacts optionalSignal switching, instrument control
CA10.A291-600FT24P / 2-posição20UM60°Lockable knob for misoperation preventionEquipment main power safety switch
CA10.PC6085-33P / 3-posição20UM45°Special star-delta camStar-delta starting for motors ≤5.5kW
CA10.A710-600E3P / 2-posição20UM60°Forward/reverse dedicated camConveyor, water pump direction switching
CA20.A290-600E4P / 2-posição32UM60°Higher current rating, double-break structureMain power control for large 3-phase equipment

Model Explanation Example: CA10.A291-600FT2

CA10: S0 outline size, 20A rated thermal current

A291: 4-pole 2-position cam logic, full-pole on-off

600: Standard auxiliary contact configuration

FT2: Lockable black knob to avoid accidental operation

  1. CG Series (Compact Heavy-duty Control Switches, 10~40A)

Same overall dimension as CA series, equipped with front wiring terminals, more convenient for standard control cabinet installation.

ModeloPoloneses / PositionsCorrente nominalModo de fiaçãoPrincipais vantagensCenários Aplicáveis
CG10.A200.FT11P / 2-posição10UMFiação frontalEasy installation and wiringSmall control cabinets, operação frequente
CG10.A210-600FT23P / 2-posição10UMFiação frontalDedicated motor control camDirect start of motors ≤2.2kW
CG25.A290-600E4P / 2-posição25UMFiação frontalHigh current bearing, double-break designMedium equipment power control, 3-phase 4-wire system
CG40.A291-600E4P / 2-posição40UMFiação frontalHeavy-duty structure, long mechanical lifeHeavy equipment frequent start-stop control
  1. CH Series (Instrument & Precision Control Switches, 10~40A)

Specially developed for instrument measurement and precise signal switching, optional gold-plated contacts, applicable to low-current high-precision control occasions.

ModeloPoloneses / PositionsCorrente nominalTipo de contatoAplicativo principalUnique Advantages
CH10.A007.FT21P / 2-posição10UMLiga de prataSingle-channel signal switching, instrument selectionUltra-low contact resistance, medição de alta precisão
CH10.A210-600E3P / 2-posição10UMGold-plated (opcional)Tensão & current switching, equipamento de testeAnti-corrosion, suitable for humid environment
CH20.A290-600E4P / 2-posição20UMLiga de prataMulti-functional instrument control, multi-way switchingProjeto modular, expandable auxiliary contacts
CH40.A291-600E4P / 2-posição40UMLiga de prataIndustrial instrument main power, signal distributionExcellent insulation performance, fit for high-voltage measurement system
  1. KG Series (Safety Isolating Switches, 10~63A)

Enclosed safety isolating switches with excellent short-circuit resistance, preferred main switch and maintenance switch for machine tools and power distribution cabinets, compatível com IEC 60947-3.

ModeloCorrente nominalPolonesesClasse de ProteçãoFunção principalAplicação Típica
KG10.A001-60010UM2PIP40Basic isolation functionSmall equipment power isolation, maintenance protection
KG16.A200-60016UM3PIP40With built-in auxiliary contactsMachine tool main power, 3-phase motor isolation
KG20.A290-60020UM4PIP40Full-pole isolation4-wire system power isolation, prevenção de choque elétrico
KG32.A291-60032UM4PIP4010kA high short-circuit withstandMedium equipment main switch, distribution cabinet isolation
KG63.A290-60063UM4PIP40Heavy-duty reinforced structureLarge industrial equipment main power, power distribution system

Destaques do projeto de segurança

  1. Forced breaking structure ensures reliable contact separation and eliminates arc risks
  2. Extra large isolation clearance beyond industry standard to improve operational safety
  3. Optional cabinet door interlock device to prevent live cabinet opening operation
  4. Série de aplicações especiais

5.1 Explosion-proof Series (CA-Ex / CG-Ex / KG-Ex)

Modelos Típicos: CA10-Ex.A290-600E, KG20-Ex.A291-600

Certificação: ATEX certified, applicable to Zone1/21 gas hazardous area and Zone2/22 dust hazardous area

Aplicativo: Químico, petroleum, natural gas, mining and other flammable and explosive industries

5.2 Dedicated DC Series (G20)

Modelos Típicos: G20.1000, G20.2000

Tensão nominal: DC 1000V / DC 1500V, corrente nominal: 100A~2000A

Aplicativo: Photovoltaic inverters, sistemas de armazenamento de energia, electric vehicle charging piles

5.3 High-current L Series (350~2400A)

Características: Modular assembly, expandable auxiliary contacts, IP54 protection grade

Aplicativo: Industrial main power distribution, large generator set power control

  1. Quick Selection Table by Application Scenario
Cenário de aplicaçãoSérie recomendadaModelo típicoParâmetros principais
Controle de motor pequeno (≤5.5kW)CA10 / CG10CA10.PC6085-33P/3-position, star-delta startup
Equipment main power switchCA10 / KG20CA10.WAA345EF / KG20.A290-6004P/2-position, 20UM
Instrument signal switchingCH10CH10.A007.FT21P/2-position, gold-plated contact optional
Machine tool maintenance switchKG SeriesKG16.A200-6003-pólo, lockable type, safety interlock
Photovoltaic & sistema de armazenamento de energiaG20G20.1000DC1000V, 100Uma classificação
Explosion-proof working environmentCA-Ex SeriesCA10-Ex.A290-600EATEX certified, Zone1 applicable
  1. Notas de seleção
  2. Correspondência atual: Select switches according to AC-3 motor load standard, reserve 1.2~1.5 times current margin
  3. Seleção de pólo: Choose 3-pole for pure 3-phase loads, 4-pole for 3-phase 4-wire system to realize neutral line breaking
  4. Modo de operação: Adopt lockable knob for frequent use to prevent misoperation; key-operated type for high-safety occasions
  5. Adaptação Ambiental: Select IP65 high protection grade for damp sites; stainless steel shell type for corrosive environment
  6. General Naming Rule Summary
SérieBasic CodeMounting CodeCam CodeAuxiliary CodeActuator Code
CA/CG/CHCA10W=Panel / V=VerticalA291=4P/2-position600=Standard Aux. ContatoEF=Black Knob / FT=Lockable Knob
KG SeriesKG20Fixed enclosed typeA290=4P/2-position600=Standard Aux. ContatoAlça rotativa / key handle
Explosion-proof SeriesCA10-ExMontagem padrãoA290=4P/2-position600=Standard Aux. ContatoExplosion-proof dedicated handle
DC G20 SeriesG20Panel mounting1000=100A rating-Rotary operating handle

Anterior:

Deixe uma resposta

Deixe um recado