Schneider XCKM102 Limit Switch - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Schneider XCKM102 Limit Switch - Contator,disjuntor,sensor,Codificador,CLP,Conversor

elétrica/

Schneider XCKM102 Limit Switch

Complete order-part numbers: XCKM102C (Pg11 cable entry)、XCKM102H29 (Entrada de cabo M20×1,5, commonly used in China) Série: Telemecanique XC-Standard metal-housing limit switch, actuator ZCK-D02 steel-roller plunger, spring return Model Code Explanation XCKM: M = Zamak zinc-alloy metal housing, modular limit-switch body 102: Contact block: 1NO+1NC snap-action contacts with forced-opening safety NC contact; supplied with ZCK-D02 roller-plunger actuator ...

  • Detalhes do produto

Complete order-part numbers: XCKM102C (Pg11 cable entry)、XCKM102H29 (Entrada de cabo M20×1,5, commonly used in China)

Série: Telemecanique XC-Standard metal-housing interruptor de limite, actuator ZCK-D02 steel-roller plunger, retorno na primavera

Explicação do código do modelo

XCKM: M = Zamak zinc-alloy metal housing, modular limit-switch body

102: Contact block: 1NO+1NC snap-action contacts with forced-opening safety NC contact; supplied with ZCK-D02 roller-plunger actuator

Sufixo C: Pg11 threaded cable entry; Suffix H29: M20×1.5 metric threaded cable entry (mainstream for domestic projects)

Especificações Técnicas Principais

ItemParâmetro
Configuração de contato1 Normally‑Open (NO‑13‑14) +1 Normally‑Closed (NC‑21‑22), snap‑action with forced opening
AtuadorTop steel‑roller plunger, retorno na primavera, bidirectional side actuation
Actuating ForceMinimum operating force 12 N; Minimum forced‑opening force 36 N
Classificações ElétricasAC‑15 240V /3A; DC‑13 250V/0.27A; Máx.. 500 V
TerminaisTerminais de parafuso, conductor cross‑section 0.34‑1.5 mm²
Classe de ProteçãoIP66, IK05
Vida Mecânica20 milhões de operações
Temperatura operacional‑25℃~+70℃
Dimensões Gerais64×64×30 mm, peso aprox.. 0.255 kg
Entradas de cabos3 threaded ports; XCKM102C=Pg11; XCKM102H29=M20×1.5

Definição de terminal

13-14: NO Normally-Open

21-22: NC Normally-Closed

⚠️ The NC contact features forced-opening function, designed for safety circuits; do not treat it as an ordinary micro-switch contact.

Aplicações Típicas

Machine-tool hard overtravel limit, equipamento transportador, lifting machinery, position detection for automation equipment. Suitable for dusty and splashing-water environments; metal housing provides impact resistance. Projeto modular: ZCK-D02 actuator can be replaced separately without changing the whole switch.

Substituição & Seleção

  1. Original OEM replacement: XCKM102H29 (M20) / XCKM102C (Pg11)
  2. Domestic compatible alternatives: Metal-housing roller-plunger limit switches; verificar: 1NO+1NC snap-action, IP66, mounting hole pitch 64 mm
  3. Same-series actuator exchange: Retain switch body, fit various ZCK-XX lever-type actuators.

Falhas Comuns & Solução de problemas

  1. Sem sinal: Check roller-plunger jamming / fadiga da primavera; inspect contact burning; verify screw-terminal tightening torque.
  2. Sinal instável: Reserve sufficient mechanical over-travel; avoid over-compressing plunger; actuating speed ≤0.5 m/s.
  3. Water ingress damage: Match cable gland to entry thread; do not force Pg11 gland onto M20 port.

Observação: XCKM102 consists of body plus actuator. Confirm cable-entry thread when ordering; XCKM102H29 is preferred for most Chinese field installations.

Cenários de aplicação de Schneider XCKM102 Steel-Roller-Plunger Limit Switch

Principais recursos: Top steel-roller plunger, bidirectional side actuation, automatic spring return, 1Contatos de ação instantânea NO+1NC, forced-opening safety NC contact, IP66 metal housing. Designed for lateral cam-dog actuation, for position confirmation, hard overtravel limiting and safety interlocking.

  1. Machine-Tool Equipment
  2. Máquinas-ferramentas CNC, fresadoras, tornos, moedores: Positive/negative hard overtravel protection for slides / work-tables to prevent collision; tool-change position feedback, tailstock position check, pallet clamping confirmation.
  3. Injection-molding machines, die-casting machines: Mold open-close position detection, mechanical safety-gate interlock; ejector-stroke limit.
  4. Equipamento de imprensa: Slide travel limit, guard-door interlock; NC contact wired into safety circuit.

✅ Selection hint: Plunger requires lateral cam actuation. Cam-dog surface shall be smooth to prevent heavy impact damage to roller.

  1. Material-Handling & Equipamento de transporte
  2. Cinto, rolo, transportadores de corrente: Pallet/bin stop-position signal, end-of-travel limit, stop-dog position feedback; sorting-mechanism position signal.
  3. Plataformas elevatórias, guinchos, stacker cranes: Upper/lower travel limits, fork extend/retract confirmation; over-travel prevention; NC contact for safety cut-off circuit.
  4. Armazéns automatizados: Rail hard limit for shuttle cars, position confirmation.
  5. Embalagem & Printing Production Lines
  6. Máquinas de embalagem, seladores de caixas, rotuladores: Cilindro / slide position detection, mechanism status feedback; roll-holder limit.
  7. Máquinas de impressão: Paper-pile lifting limit, pusher-mechanism position signal.
  8. Elevação & Light Machinery
  9. Pequenas pontes rolantes, electric chain hoists: Trolley travel limit, lifting-tool position sensing (not for main hoist ultimate height limit — heavy-duty lever-head type is recommended for main hoist).
  10. Robôs, gantry axes: Mechanical hard limit (physical backup beyond PLC soft-limit).
  11. Industrial Doors, Gates & Access Interlocks
  12. High-speed industrial doors, lifting gates: Full-open / full-closed position feedback; intertravamento de segurança.
  13. Machine-guard access doors, maintenance hatches: Door-closed confirmation interlock; stop equipment when door opens.
  14. Other Industrial Machinery

Máquinas têxteis: Slider limit for looms & carding machines

Water-treatment & environmental equipment: Gate / baffle position detection

Linhas de montagem: Fixture-clamping position confirmation

Operating-Condition Compatibility

✅ Suitable for XCKM102

Lateral cam-dog pushes roller-plunger, linear reciprocating motion

Empoeirado / splashing-water ambient conditions requiring IP66

Safety circuits requiring forced-opening NC contact

Medium actuating force (≥12 N), immune to minor vibration false-triggering

❌ Not Suitable

  1. Direct vertical impact onto plunger (risk of internal-mechanism damage)
  2. Large-stroke pivoting actuation (use lever-head models e.g. XCK-M115)
  3. Repeated high-speed impact; maximum actuating speed ≤0.5 m/s.

Typical Wiring Practices

  1. Position-reached signal: Usar 13-14 (NÃO). Contact closes when cam compresses plunger; status read by PLC.
  2. Hard safety-limit: Arame 21-22 (NC, forced-opening) in series within motor-control circuit. On over-travel impact, hardware directly cuts power, independent of PLC logic.

Complete Technical Specifications for Schneider XCKM102 Limit Switch

Série: XC-Standard (Telemecânica); Atuador: ZCK-D02 steel-roller plunger, retorno na primavera, bidirectional side actuation

Order-part variants:

XCKM102C: Pg11 cable entry

XCKM102H29: M20×1.5 metric cable entry (widely used in China)

  1. Especificações Mecânicas
ItemParâmetro
AtuadorSteel‑roller plunger, automatic spring return, bidirectional side actuation
Minimum Operating Force12 N
Minimum Forced‑Opening Force36 N (for safety NC contact)
Máx.. Permitted Operating Speed0.5 m/s, high‑speed impact not permitted
Mínimo. Velocidade operacional0.01 m/min
Vida Mecânica20 milhões de operações
Material da HabitaçãoZamak zinc‑alloy
Dimensões Gerais64 × 64 × 30 mm
Peso líquido0.255 kg
Entradas de cabos3 threaded ports; C‑variant Pg11; H29‑variant M20×1.5
Classe de ProteçãoIP66; Impact resistance IK05
Resistência à vibração10‑500 Hz, 25 gn
Resistência ao choque50 gn, 11 EM
  1. Especificações Elétricas
ItemParâmetro
Configuração de contato1NÃO(13-14)+1NC(21-22), snap‑action with forced‑opening NC contact
Corrente Térmica Convencional Ith10 A AC
AC‑15 Inductive Load240 V, 3 UM (A300)
DC‑13 Inductive Load250 V, 0.27 UM (Q300)
Tensão nominal de isolamento Ui500 V (Grau de poluição 3)
Tensão nominal de impulso suportável Uimp6 kV
Vida Elétrica (DC-13)5 milhões de operações
Short‑Circuit Protection10 A gG fuse
TerminaisTerminais de fixação por parafuso, condutor: 0.34‑1.5 mm², accept two wires per terminal
  1. Condições Ambientais

Temperatura operacional: -25℃ ~ +70 ℃

Temperatura de armazenamento: -40℃ ~ +70 ℃

Certificações: CCC, UL508, CSA; complies with IEC 60947-5-1, IEC 60204-1

  1. Definição de terminal

13-14: NO Normally-Open (position-reached signal)

21-22: NC Normally-Closed (forced-opening, for hard-safety-limit circuits)

  1. Principais notas de aplicação
  2. Designed for lateral cam-dog compression of roller-plunger. Vertical direct impact is not recommended; 30°-angled cam profile is preferred.
  3. Modular construction: ZCK-D02 actuator can be replaced separately without replacing complete switch unit.
  4. Confirm cable-entry thread at ordering: Prefer XCKM102H29 (M20×1,5) for new-build Chinese projects; XCKM102C for legacy Pg11 installations.

Operating Principle of Schneider XCKM102 Limit Switch

XCKM102 is a modular metal-housing mechanical limit switch, fitted with ZCK-D02 roller-plunger actuator. Princípio fundamental: Mechanical force → plunger displacement → internal snap-action contact toggle → automatic spring return; NC contact implements mechanical forced-opening safety feature, compliant with IEC 60947-5-1.

  1. Mechanical Operating Sequence
  2. Free state (non-actuated)

Cam-dog does not contact roller-plunger; return spring holds plunger outward at home position.

Status: 21-22 NC fechado; 13-14 NÃO aberto.

  1. Actuated state (cam-dog compresses roller)

Moving-machine cam-dog laterally pushes steel roller and compresses plunger inward.

Once plunger travels past operating point, internal snap-action rocker mechanism triggers instantaneous contact state change; transition is abrupt, not gradual.

Snap-action benefit: Reliable make-break independent of cam-dog speed; eliminates contact chatter / bounce.

Actuated status: 21-22 NC aberto; 13-14 NÃO fechado.

  1. Reset process

Cam-dog moves away, external force removed; return spring pushes plunger back to home position, contacts restore original state.

⚠️ Caution: Designed for lateral compression. Direct vertical pounding on plunger may destroy internal components.

  1. Forced-Opening Principle for Safety NC Contact 21-22 [Crítico]

O 21-22 NC contact is not a standard micro-switch contact; it implements mechanical forced-opening construction:

When plunger is fully depressed, rigid mechanical linkage physically pries the NC contacts apart, not relying only on contact-spring force.

Even in case of contact welding / furando, mechanical linkage can forcibly separate contacts to break the circuit.

Portanto 21-22 NC is dedicated to hard-safety-limit and safety-interlock circuits, achieving hardware-level power cut-off independent of PLC software logic.

Never use NO contacts for safety circuits; NO contacts have no forced-opening capability.

  1. Electrical Logic Table
Switch Status13-14 (NO Normally‑Open)21-22 (NC Forced‑Opening Normally‑Closed)
Non‑actuated (home)AbrirFechado
Cam‑dog actuatedFechadoAbrir
Cam‑dog retracted, reiniciarAbrirFechado

Two Typical Wiring Modes

  1. Position-feedback signal (PLC digital input): Usar 13-14 NÃO; closure indicates target position reached.
  2. Hardware hard-overtravel protection: Series-connect 21-22 NC into contactor-control circuit. Overtravel impact opens switch and directly de-energizes control circuit to avoid machine damage.
  3. Modular Construction Breakdown

XCKM102 consists of three assemblies:

  1. Atuador: ZCK-D02 (roller-plunger, mola de retorno) receives external mechanical input.
  2. Contact block: Snap-action rocker-contact assembly performs circuit switching.
  3. Carcaça metálica: Provides mechanical mounting, environmental protection and wiring terminals.

Damaged actuator can be replaced separately with ZCK-D02; full-switch replacement is unnecessary.

  1. Fault-Mechanism Analysis
  2. Signal chatter / piscando: Cam-dog travel insufficient; plunger stays near transition threshold without full over-travel.
  3. Contacts fail to reset: Plunger jamming; return-spring fatigue or fracture.
  4. Safety-circuit loss: Mis-application of NO contact for safety function; or contact welding (only NC provides forced-opening anti-weld protection).