Siemens 3RH1921-1HA22 Contactor Side-Mount Accessory - Contator,disjuntor,sensor,Codificador,CLP,Conversor

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Siemens 3RH1921-1HA22 Contactor Side-Mount Accessory - Contator,disjuntor,sensor,Codificador,CLP,Conversor

contator/

Siemens 3RH1921-1HA22 Contactor Side-Mount Accessory

Nome completo do produto: SIRIUS side-mounted auxiliary switch block, 4-pólo, 2NÃO+2NC, screw terminals Product Status: Descontinuado (PLM PM500). It is an older accessory for 3RT1 contactors. The new-generation replacement series is 3RH29xx Model Nomenclature 3RH: SIRIUS auxiliary switches / contactor relay accessories 19: External side-mounted auxiliary contacts for contactors 21: Side snap-on mounting, fits S0~S3 contactor ...

  • Detalhes do produto

Nome completo do produto: SIRIUS side-mounted auxiliary switch block, 4-pólo, 2NÃO+2NC, terminais de parafuso

Status do produto: Descontinuado (PLM PM500). It is an older accessory for 3RT1 contatores. The new-generation replacement series is 3RH29xx

  1. Nomenclatura do Modelo

3RH: SIRIUS auxiliary switches / contactor relay accessories

19: External side-mounted auxiliary contacts for contactors

21: Side snap-on mounting, fits S0~S3 contactor sizes

1: Terminais de parafuso; 2 = spring-cage terminals (3RH1921-2HA22)

HA: 4-pole side-mounted contact block

22: Configuração de contato 2 Normalmente aberto + 2 Normalmente fechado (2NÃO+2NC)

  1. Principais parâmetros técnicos
  2. Contatos: 2NÃO+2NC, 4-pólo, compatível com EN 50012
  3. Montagem: Snap-on side installation on the contactor
  4. Compatible base unit: SIRIUS 3RT1 motor contactors, frame sizes S0 / S2 / S3
  5. Terminais: Tipo de parafuso, wire cross-section 0.5~2.5 mm²
  6. Proteção: Front face IP20
  7. Tensão nominal de isolamento: 690 V (grau de poluição 3), tensão suportável de impulso 6 kV
  8. Endurance: Vida mecânica 10 milhões de ciclos operacionais; AC-15 230V electrical life 200,000 ciclos
  9. Temperatura operacional: -25 ~ +60 °C; temperatura de armazenamento: -55 ~ +80 °C
  10. Contact reliability: 17 V / 1 mA, máx. 1 failure within 100 milhões de operações
  11. Cenários de aplicação

Side expansion of auxiliary contacts for 3RT1 (S0~S3) Contatores CA

PLC feedback signals, indicação de status, circuitos de intertravamento, saída de sinal de falha

Motor start-stop control circuits, fã & water pump control panels, low-voltage switchgear cabinets

Observação: Side auxiliary switches can only be fitted on the left side of the contactor. The total number of NC contacts is limited; positively driven contacts must be verified for safety interlock applications.

  1. Seleção de substituição (Discontinued Upgrade)

Modelo original descontinuado. The corresponding side-mounted unit for new 3RT2 (S0~S3) contatores:

3RH2921-1DA22 (terminal de parafuso, 2NO+2NC side-mounted auxiliary switch)

  1. Solução de problemas & Inspection Guidelines
  2. Falhas comuns: Oxidação de contato, contact burning, loose snap-fit clips leading to intermittent feedback signals
  3. Teste de multímetro: With the contactor de-energized, NC contacts shall be conducting and NO contacts open; contact status flips when the coil is energized
  4. Verificação da fiação: Tighten all terminal screws firmly; loose thin wires frequently cause unstable PLC digital inputs
  5. Substituição: Direct snap-on disassembly without touching the main power circuit; always test interlock logic after replacement
  6. Cross-reference List for the Same Series

3RH1921-1HA22: Terminais de parafuso, 2NÃO+2NC, side mount S0–S3 (Descontinuado)

3RH1921-2HA22: Terminais de mola, same contact configuration (Descontinuado)

3RH2921-1DA22: New-generation screw-type side-mounted 2NO+2NC (Modelo de substituição)

Siemens 3RT1 Contactor Replacement Overview

3RT1 (S00~S3, ≤95A) foi descontinuado (PLM PM500). First-choice official direct replacement: 3RT2 (imported SIRIUS Innovation series). For cost-saving domestic alternatives, select 3RT6 / 3RT5. Larger frame 3RT1 (>95UM) remains available with no forced phase-out schedule

  1. 3RT2 [Importado, Preferred OEM Replacement]

Série: 3RT20xx, direct replacement for legacy 3RT10xx

Frame size match: S00 / S0 / S2 / S3, AC-3 current range 7A~95A

Regra de substituição:

Exemplo: 3RT1024-1BB40 → 3RT2024-1BB40. Keep coil voltage and rated current unchanged; only change the middle digit from 1 para 2.

Critical compatibility note (relevant to your 3RH1921 auxiliary contacts):

Old 3RH1921 cannot be used on 3RT2; you must upgrade to 3RH2921 series auxiliary switches together with the contactor body.

  1. Large-size 3RT1 (S6 / S10 / T12, Still Active, Not Discontinued)

S6 (3RT105×, Frame S6, 115A~150A, 55kW~75kW @400V)

Base Order No.Corrente AC-3Potência do motor (400V)Tipo de terminalAcessórios correspondentes
3RT1054115 UM55 KWParafuso / box terminalsContato auxiliar: 3RH1951; Overload relay: 3RU1156
3RT1055150 UM75 KWParafuso / box terminalsContato auxiliar: 3RH1951; Overload relay: 3RU1156

Complete model examples: 3RT1054-6AF36, 3RT1055-6NB36

S10 (3RT106×, Quadro S10, 185A~225A, 90kW~110kW @400V)

Base Order No.Corrente AC-3Potência do motor (400V)Tipo de terminalAcessórios correspondentes
3RT1064185 UM90 KWBusbar terminalsContato auxiliar: 3RH1961; Overload relay: 3RU1166
3RT1065225 UM110 KWBusbar terminalsContato auxiliar: 3RH1961; Overload relay: 3RU1166

T12 (3RT107×, Quadro S12, 265A~300A, 132kW~160kW @400V)

Base Order No.Corrente AC-3Potência do motor (400V)Tipo de terminalAcessórios correspondentes
3RT1075265 UM132 KWBusbar terminalsContato auxiliar: 3RH1971; Overload relay: 3RU1176
3RT1076300 UM160 KWBusbar terminalsContato auxiliar: 3RH1971; Overload relay: 3RU1176

T14 (Extra-large frame, still available)

3RT1096: 400UM / 200KW

3RT1097: 500UM / 250KW

  1. Dedicated Accessories for S6/S10/S12 (Not Interchangeable with S00~S3)

(1) Side-mounted auxiliary switches (Base unit already has built-in 2NO+2NC; add-on optional)

S6: 3RH1951

S10: 3RH1961

T12: 3RH1971

Lembrete importante: 3RH1921 (for small frames) cannot be installed here due to incompatible snap-in geometry.

(2) Plug-in thermal overload relays (direct plug-on mounting with 3RT1)

S6: 3RU1156

S10: 3RU1166

T12: 3RU1176

(3) Mechanical interlocks (for reversing contactor pairs)

S6: 3RT1951

S10: 3RT1961

T12: 3RT1971

  1. Coil Voltage Suffix Codes (Universal for all frames)

1AB36: CA/CC 24 V

1AD36: CA/CC 48 V

6AF36: AC/DC 110~127 V

6AU36: AC/DC 200~277 V (wide-voltage coil)

  1. Phase-out Boundary Rules (Crítico)
  2. 3RT101~3RT104 (S00~S3, ≤95A): PM500, fully discontinued. Must migrate to 3RT2 / 3RT6.
  3. 3RT105~3RT107 (S6/S10/S12): PM300, active production, long-term supply, no end-of-life plan.
  4. Future upgrade path (if needed): 3RT105 → 3RT205; 3RT106 → 3RT206; 3RT107 → 3RT207. Replace accessories with 3RH2951/2961/2971 accordingly.
  5. Popular Complete Order Numbers
  6. 3RT1054-6AF36|S6, 115UM, AC/DC 110V coil
  7. 3RT1055-6NB36|S6, 150UM, wide-voltage coil
  8. 3RT1064-6AU36|S10, 185UM, AC/DC 240V coil
  9. 3RT1065-6AU36|S10, 225UM, AC/DC 240V coil
  10. 3RT1075-6AU36|S12, 265UM
  11. 3RT1076-6AU36|S12, 300UM

Anterior:

Deixe uma resposta

Deixe um recado