SIEMENS 3RT1056-6AP36 Power Contactor

SIRIUS 3RT series 3-pole AC power contactor, Size S6, main circuit busbar connection, AC/DC 220~240V coil, built-in 2NO+2NC auxiliary contacts Model Decoding 3RT1056-6AP36 3RT: SIRIUS power contactor series 10: Contator padrão (non-safety, tipo sem reversão) 56: Frame size S6, AC-3 400V 185A 6: Coil voltage 220…240V AC/DC A: Main circuit busbar connection P: Screw terminals for ...

  • Detalhes do produto

SIRIUS 3RT series 3-pole AC power contactor, Size S6, main circuit busbar connection, AC/DC 220~240V coil, built-in 2NO+2NC auxiliary contacts

  1. Decodificação de modelo

3RT1056-6AP36

3TR: SIRIUS power contactor series

10: Contator padrão (non-safety, tipo sem reversão)

56: Frame size S6, AC-3 400V 185A

6: Coil voltage 220…240V AC/DC

UM: Conexão do barramento do circuito principal

P: Screw terminals for auxiliary contacts

36: Contatos auxiliares 2 Normalmente aberto + 2 Normalmente fechado (2NÃO+2NC)

  1. Especificações elétricas principais
ItemParâmetro
Número de pólos principais3 postes (3NÃO)
AC-3 (Motor load @400V)185UM, 90kW
AC-1 (Resistive load @40℃)215UM
Tensão nominal de operação UeMáx.. 1000V e
Coil control voltage Uc220~240V CA/CC (Wide-range AC/DC coil)
Contatos auxiliares2NÃO + 2NC, terminais de parafuso
Conexão do circuito principalBarramento
Tamanho do quadroS6
Grau de proteçãoFront IP00; IP20 with cover installed
Tensão suportável de impulso8kV main circuit / 6kV auxiliary circuit
Temperatura ambiente-25℃ ~ +60 ℃ (Derating necessário acima de 40℃)
  1. Escopo de aplicação

On/off control of 3-phase motors such as fans, bombas de água e compressores

Control cabinets, ar condicionado central, industrial production lines and power cabinets

Can be matched with 3RU thermal overload relay for motor overload protection; 3RT19 surge suppressor for coil EMC interference suppression

  1. Modelos Alternativos
  2. Doméstico SIEMENS substituição: 3RT5056-6AP36

Função idêntica, current rating and coil specification. Made in China, direct replacement for 3RT1056-6AP36 with identical mounting dimensions, officially recommended replacement model

  1. Upgraded model in same series: 3RT1064-6AP36 (AC-3 225A, 110kW)
  2. Downsized model in same series: 3RT1055-6AP36 (AC-3 150A, 75kW)

Observação: 3RT1056 manufactured in Germany; 3RT5056 manufactured domestically. Fully compatible in electrical performance and mounting hole layout, direct interchangeable in projects.

  1. Instalação & Diretrizes de Manutenção
  2. Instalação: Montagem vertical, tilt ≤ ±5°. Heat dissipation clearance required. S6 frame generates considerable heat; derating is required for multiple units mounted side-by-side inside cabinet.
  3. Circuito principal: Conexão de barramento, tighten to specified torque per datasheet to prevent overheating and contact burning.
  4. Bobina: Wide-range AC/DC coil, compatible for AC and DC control. 3RT19 surge suppression module is recommended in parallel to reduce interference to PLC digital outputs.
  5. Contact life: Under AC-3 motor duty, mechanical life approx. 10 milhões de operações; electrical life depends on breaking current.
  6. Solução de problemas

Coil energized but no pull-in: Medir a tensão da bobina, check coil open circuit or mechanical jamming

Pull-in but no continuity on main circuit: Loose busbar or burned main contacts

Chattering / ruído anormal: Baixa tensão da bobina, accumulated dust on iron core, fadiga da primavera

  1. Código HS Aduaneiro

85364900 (Electromagnetic contactor)

  1. Optional Spare Parts & Acessórios

Relé de sobrecarga térmica: 3RU2156 series (for 90kW motor)

Supressor de surto: 3RT1955-1CD00 (RC circuit), 3RT1955-1DG00 (Varistor)

Bloco de contato auxiliar: 3RH1951 (for extra auxiliary contacts)

Arc shield & main contact repair kit: 3RT1956 contact assembly

Tabela de comparação: SIEMENS 3RT1056-6AP36 VS 3RT5056-6AP36

Both models feature identical electrical parameters, mounting dimensions and compatible accessories for direct replacement. The core differences lie in origin, nameplate marking, lead time and applicable certifications.

Item de comparação3RT1056-6AP36 (Imported Version)3RT5056-6AP36 (Versão Doméstica)
Linha de ProdutosSIRIUS 3RT1, global standard imported versionSIRIUS 3RT5, local domestic version
OrigemAmberg Factory, AlemanhaSIEMENS low voltage plant in China (SEAL)
AC-3 @400V185UM / 90kW185UM / 90kW
AC-1 Resistive Load215UM215UM
Especificação da bobina220~240V CA/CC220~240V CA/CC
Contatos Auxiliares2NÃO+2NC, terminais de parafuso2NÃO+2NC, terminais de parafuso
Conexão do Circuito PrincipalBarramentoBarramento
Tamanho do quadroS6S6
Dimensão Geral / Orifícios de montagemIdêntico, direto intercambiávelIdêntico, direto intercambiável
Vida Mecânica10 milhões de operações10 milhões de operações
Vida Elétrica AC-3Mesmo (depends on breaking current)Mesmo (depends on breaking current)
Faixa de temperatura ambiente-25℃ ~ +60 ℃-25℃ ~ +60 ℃
Acessórios compatíveisCompatibilidade total: 3RU thermal relay, 3RT19 surge suppressor, contact repair kit, bloco de contato auxiliar100% compatible with accessories of 3RT1056
CertificaçõesCCC, CE, UL, CSA, suitable for overseas projectsCCC, CE; UL optional for certain batches, standard for domestic projects
Placa de identificaçãoAlemão + English marking, Fabricado na Alemanhachinês + English marking, made in China
Delivery Lead TimeLongo, mostly forward order with unstable lead timeCurto, domestic stock available with fast delivery
PreçoMais altoLower with cost advantage
Cenários de aplicaçãoEquipamento de exportação, projetos no exterior, high-end foreign-invested projects, cases requiring imported componentsDomestic control cabinets, bombas de água & fãs, AVAC, general industrial automation
Desempenho ElétricoIdêntico, no derating differenceIdêntico, no derating difference
Código HS8536490085364900
Model Naming Definition3RT10: Global original series3RT50: Domestic localized series

Notas principais

  1. Intercambialidade: SIEMENS officially approves direct replacement. No modification required for cabinet cutout, barramento, secondary control loop or thermal relay selection. Electrical characteristic curve, temperature rise and contact breaking capacity are identical.
  2. Orientação de seleção

✅ Choose 3RT5056: Projetos nacionais, budget control, fast delivery; preferred for most domestic panel building projects.

✅ Choose 3RT1056: Máquinas de exportação, overseas site, specification explicitly requiring German origin, mandatory UL/CSA certification.

  1. Misconception Clarification: It is NOT a downgraded domestic variant. Same product platform and design, manufactured at different factories under identical design and test standards.

Suplementar: Shared Spare Parts List

Relé de sobrecarga térmica: 3RU2156 series

Supressor de surto: 3RT1955-1CD00 / 3RT1955-1DG00

Main contact repair kit: 3RT1956

Additional auxiliary contact block: 3RH1951

Application Scenarios for 3RT1056-6AP36 and 3RT5056-6AP36

Identical load capacity for both models, rated for 400V, 90kW 3-phase motor direct-on-line start (AC-3, 185UM). Differences are only based on project location, certification requirements and client procurement specification, NOT load capacity.

  1. Common Applications (Both Models Applicable)

(1) Direct-on-line Motor Starting (Main AC-3 Duty)

Bombas de água, bombas de esgoto, bombas de circulação (tratamento de água, AVAC, prédio, indústria química)

Compressores de ar, grandes fãs, exaustores de fumaça

Transportadores, misturadores, extrusoras, trituradores (comida, building material, mineração)

Chillers and large refrigeration compressors for central air conditioning

MCC motor control centre drawer units for 90kW motor circuits

(2) AC-1 Resistive Load

High-power heating elements, fornos de resistência

Main circuit switching of high-power circuits inside distribution cabinets

(3) AC-6B Capacitor Switching

Capacitor bank switching for reactive power compensation cabinet (reactor required to suppress inrush current)

Correspondência: 3RU thermal relay for motor overload protection; 2NO+2NC auxiliary contacts for PLC running feedback and fault interlock.

  1. Preferred Scenarios for 3RT5056-6AP36 (Domestic Local Version)
  2. Domestic panel projects, domestic factories, AVAC, fornecimento de água & drenagem, general factory automation

Complete CCC certification for domestic projects, sufficient stock and cost advantage, preferred by most EPC and cabinet manufacturers.

  1. Domestic municipal projects: Estações de tratamento de águas residuais, municipal pump stations, building HVAC cabinets
  2. Domestic machinery OEM: Fãs, compressores de ar, chiller units sold in domestic market
  3. Ordinary motor circuits in domestic power plants, metallurgy and chemical plants (no mandatory imported component requirement by client)
  4. Retrofit replacement for old contactors, tight budget and fast delivery required

✅ Adequado para: Domestic projects without mandatory UL/CSA certification or German origin requirement

  1. Preferred Scenarios for 3RT1056-6AP36 (German Imported Version)
  2. Máquinas de exportação & equipamento (export to Southeast Asia, Médio Oriente, Europe and other overseas sites)

Full set of international certifications CE, UL, CSA to meet overseas owner and customs requirements.

  1. New construction projects of foreign-invested factories where technical specification explicitly requires SIEMENS components made in Germany
  2. Overseas EPC projects, control cabinets exported together with equipment, certificate of origin required
  3. High-end pharmaceutical and semiconductor foreign projects where imported components are specified by client
  4. Spare part replacement for legacy equipment: Original unit fitted with 3RT1056 and client requires identical OEM spare parts

✅ Adequado para: Máquinas de exportação, projetos no exterior, client specified imported components, mandatory UL/CSA certification

  1. Seleção para evitar armadilhas
  2. Identical load rating: Both can drive 90kW motors. 3RT5056 has no limitation for heavy-duty applications; only differs in origin and certification documents.
  3. For domestic projects without “imported contactor” clause in specification, 3RT5056 is preferred for shorter lead time and better price.
  4. For export to Europe / América do Norte, select 3RT1056 and confirm in advance whether UL/CSA certificates are required.
  5. Heavy vibration & dusty heavy industry environments (mineração, cement plant): Both have identical mechanical life. Installation and heat dissipation requirements are the same; selection only depends on origin requirement.
  6. Cenários não aplicáveis

Direct-on-line starting for motor power exceeding 90kW; soft starter recommended for higher power.

Frequent jogging, frequent forward/reverse AC-4 duty (accelerated contact wear, derating evaluation required)

Safety circuits and emergency stop safety functions (SIEMENS safety contactor 3RT2 series should be adopted)