Siemens 3VA9267-0HA20 Molded Case Circuit Breaker - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

Conversamos: +86-13184948252 Whatsapp: 0086-13811255435 E-mail: kent@bestcontactor.com

Sobre Contato |

 Siemens 3VA9267-0HA20 Molded Case Circuit Breaker - Contator,disjuntor,inversor solar,medidor elétrico,baterias solares

disjuntor/

Siemens 3VA9267-0HA20 Molded Case Circuit Breaker

Model Code Interpretation Segment 3VA 9 267 -0HA 20 Meaning Product series: SENTRON 3VA molded case circuit breaker system Accessory category: 3VA9 series accessories Accessory type: MO320 Front-mounted Motor Operator Control voltage code: 110-230V e / 110-250V DC Applicable breaker rating: 3VA2 100/160/250A Description Flagship low-voltage power distribution series of Siemens, covering MCCBs from 16A ...

  • Detalhes do produto

Interpretação de código modelo

Segmento3VA9267-0HA20
SignificadoSérie de produtos: SENTRON 3VA molded case circuit breaker systemAccessory category: 3VA9 series accessoriesAccessory type: MO320 Front-mounted Motor OperatorControl voltage code: 110-230V e / 110-250Em DCApplicable breaker rating: 3VA2 100/160/250A
DescriçãoFlagship low-voltage power distribution series of Siemens, covering MCCBs from 16A to 1600AAccessory system specially designed for 3VA series circuit breakersMO320 motor operator, supporting remote closing and trippingProjeto de ampla tensão, compatible with various power supply systemsSuitable for 3VA2 circuit breakers rated at 100A, 160A and 250A
  1. Principais Especificações Técnicas
Categoria de parâmetroDados TécnicosObservações
Informações gerais
Nome do produtoMO320 Front-mounted Motor OperatorFor 3VA2 series molded case circuit breakers
Número do pedido.3VA9267-0HA20Standard commercial model
Status do produtoAtivo (PM300)Defined by Siemens Product Lifecycle Management System
Parâmetros Elétricos
Tensão de controle110-230V e (50/60Hz) / 110-250Em DCWide voltage compatibility
Rated Apparent Power250VAPower consumption of the operator
Tempo de operação (Fechando & Tropeçar)Typical 1 segundoMechanical response time
Parâmetros Mecânicos
Dimensões (L×A×P)105mm×75mm×132mmCompact design to save cabinet space
PesoAprox.. 846gEasy for installation and maintenance
Terminal CapacityFor 1.5-2.5mm² conductorsSólido, stranded and fine-stranded conductors applicable
Wire Stripping Length7milímetrosEm conformidade com os padrões IEC
Tightening Torque0.36-0.44N·mEnsure reliable connection
Parâmetros Ambientais
Temperatura operacional-25°C a +70°CAdequado para ambientes industriais
Temperatura de armazenamento-40°C a +80°CWide temperature range for storage
Proteção de entradaIP30Compatível com IEC 60529
  1. Full Range of MO320 Motor Operators
ModeloTensão de controleApplicable Breaker SeriesObservações
3VA9267-0HA1024-60Em DC3VA2 100/160/250Low voltage DC type
3VA9267-0HA20110-230V e / 110-250Em DC3VA2 100/160/250Universal wide voltage type (Current Model)
3VA9157-0HA1024-60Em DC3VA1 100/160For 3VA1 series
3VA9157-0HA20110-230V e / 110-250Em DC3VA1 100/160For 3VA1 series
3VA9467-0HA1024-60Em DC3VA2 400/630For high-current 3VA2 breakers
3VA9467-0HA20110-230V e / 110-250Em DC3VA2 400/630For high-current 3VA2 breakers
3VA9257-0HA1024-60Em DC3VA2 100/160Side-mounted type
3VA9257-0HA20110-230V e / 110-250Em DC3VA2 100/160Side-mounted type
  1. Concorrente & Equivalent Model List
MarcaModeloApplicable BreakerTensão de controleDescrição da substituição
Siemens3VA9267-0HA103VA2 100/160/25024-60Em DCLow-voltage alternative within the same series
Schneider ElétricaLV432642NSX 400-630380-415V eFunctional cross-brand replacement
ABBCD2-400T1-T6 Series220V CA/CCFunctional cross-brand replacement
ABBOTM-D250Tmax Series24-250V CA/CCFunctional cross-brand replacement
EatonNZM-E200NZM Series24-230V CA/CCFunctional cross-brand replacement
  1. Ambientes de aplicativos & Casos da Indústria

5.1 Cenários de aplicação recomendados

Sistemas de Automação Industrial: Remote closing and tripping of motor circuits for production line automatic control

Centros de dados: Remote operation of breakers for UPS systems to improve power supply reliability

Edifícios Comerciais: Remote control of breakers for emergency lighting and fire protection systems, complying with safety regulations

Infraestrutura Energética: Remote monitoring of breakers for photovoltaic inverters and energy storage systems to boost operation efficiency

Water Treatment Facilities: Automatic switching of pump circuits to realize unattended operation

5.2 Cenários não recomendados

Explosive Hazardous Areas: Additional explosion-proof certification is required; not suitable for direct use in IIC explosive zones

High Electromagnetic Interference Environments: Extra electromagnetic shielding is needed; not recommended near unshielded high-frequency equipment

Severe Vibration Environments: Not applicable where vibration acceleration exceeds 5g, which may impair mechanical reliability

5.3 Casos de aplicação típicos

Caso 1: Automobile Manufacturing Plant

Aplicativo: Remote control of power circuits for welding robots

Configuração: 3VA2 250A MCCB + 3VA9267-0HA20 Motor Operator + PLC Control System

Benefícios: Realize automatic power-off protection for production lines, reduce manual operation and increase productivity by 15%

Caso 2: Large-scale Data Center

Aplicativo: Remote management of Power Distribution Units (PDU) in server cabinets

Configuração: 3VA2 160A MCCB + 3VA9267-0HA20 + Building Management System (BMS)

Benefícios: Remote monitoring and circuit switching, quick fault isolation; Mean Time To Repair (MTTR) reduced to less than 5 minutos

Caso 3: Hospital Operating Room

Aplicativo: Emergency control of dedicated power circuits for medical equipment

Configuração: 3VA2 100A MCCB + 3VA9267-0HA20 + Emergency Control System

Benefícios: Fast power switching for operating rooms, ensure safe operation of medical devices; compatível com IEC 60601 medical standards

  1. Dicas de seleção & Regras de referência rápida

Selection Rhythm (For Reference)

Model 3VA9267-0HA20,

Covers 110 to 230V AC/DC,

Matches 3VA2 100/160/250A breakers,

Front-mounted MO320 design,

One second for remote switch action,

Rated power at 250VA,

Dimension 105×75×132mm,

Ideal for industrial and building applications.

Regras de referência rápida

  1. Correspondência de tensão: HA20 = Wide voltage (110-230V e / 110-250Em DC); HA10 = Low voltage (24-60Em DC)
  2. Série aplicável: 9267 = 3VA2 100/160/250A; 9157 = 3VA1 100/160A; 9467 = 3VA2 400/630A
  3. Tipo de montagem: 9267 = Front-mounted; 9257 = Side-mounted
  4. Parâmetros principais: 1-second operating time, 250VA power rating, compatible with 1.5-2.5mm² conductors
  5. Solução de problemas & Soluções
Fenômeno de falhaPossíveis causasSoluções
Failure to close or tripTensão de controle anormalVerify the voltage is within 110-230V AC / 110-250Em DC
Terminais de fiação soltosRetighten terminals with torque of 0.36-0.44N·m
Bloqueio mecânicoCheck connection between operator and breaker, remove foreign objects
Slow closing/trippingInsufficient power supply capacityEnsure control circuit power ≥ 250VA
Temperatura ambiente excessivamente baixaApply heating measures when temperature is below -25°C
Excessive operating noiseMechanical wearInspect transmission parts and replace grease if necessary
Unstable installationRe-fix the operator and ensure flat mounting surface
  1. Key Features Summary
  2. Ampla compatibilidade de tensão: 110-230V e / 110-250Em DC, reducing spare parts stock and procurement costs
  3. Resposta rápida: Typical 1-second operating time, meeting emergency control requirements
  4. Estrutura Compacta: Dimension 105×75×132mm, saving space inside switchgear cabinets
  5. Alta confiabilidade: Operating temperature range from -25°C to +70°C, adaptable to harsh industrial conditions
  6. Fácil instalação & Manutenção: Standard interface for perfect matching with 3VA2 series breakers

Typical Application Cases of Siemens 3VA9267-0HA20 (MO320 Motor Operator)

This accessory is designed for 3VA2 100/160/250A molded case circuit breakers to realize remote motorized closing and tripping. With control voltage of 110–230V AC / 110–250V CC, it is widely applied in industrial, centro de dados, building and energy sectors.

  1. Automobile Welding Workshop (Automação Industrial)

Configuração: 3VA2 250A + 3VA9267-0HA20 + CLP / Fieldbus System

Aplicativo: Remote switching and automatic fault isolation for power circuits of welding robots and welders

Benefícios: Minimize manual work, improve workshop safety; cut downtime via remote power-off during faults

  1. Large-scale Data Center (Infraestrutura)

Configuração: 3VA2 160A + 3VA9267-0HA20 + BMS / EMS

Aplicativo: Centralized remote control for cabinet PDUs, UPS outputs and precision air conditioners

Benefícios: Remote inspection and circuit operation, rapid fault location and isolation; wide voltage design compatible with global mains power

  1. Commercial Complex & Prédios altos (Smart Power Distribution)

Configuração: 3VA2 100–250A + 3VA9267-0HA20 + Fire Alarm / BAS System

Aplicativo: Interlocked control for emergency lighting, fire pumps and exhaust fans; remote power cut for energy saving during off-hours

Benefícios: Comply with mandatory fire power cut regulations; lower operation costs and improve energy efficiency

  1. Fotovoltaico & Energy Storage Power Stations (Nova Energia)

Configuração: 3VA2 250A + 3VA9267-0HA20 + Power Station Monitoring System

Aplicativo: Remote grid connection/disconnection and fault protection for AC sides of inverters and energy storage cabinets

Benefícios: Adapt to wide outdoor temperature (-25°C a +70°C); realize remote operation and reduce on-site inspection work

  1. Hospital Operating Room & UTI (Medical Power Supply)

Configuração: 3VA2 100A + 3VA9267-0HA20 + Medical Isolated Power System

Aplicativo: Emergency switching and protection for surgical equipment and life support systems

Benefícios: Fast switching (aprox.. 1 segundo), high operational reliability and compliance with medical power supply standards

  1. Tratamento de Água & Pumping Stations (Municipal Engineering)

Configuração: 3VA2 160–250A + 3VA9267-0HA20 + Pump Station PLC

Aplicativo: Remote start/stop and overload protection for submersible pumps, blowers and chemical dosing equipment

Benefícios: Suitable for humid and dusty environments; unattended remote control to reduce operation costs

Core Matching Points

Applicable Breakers: 3VA2 100/160/250A (3-pólo / 4-pólo)

Tensão de controle: 110–230 Vca / 110–250V CC (Universal wide voltage)

Tipo de montagem: Front-mounted (MO320), Dimensão: 105×75×132mm

Funções principais: Remote closing & tripping, fault isolation; adequado para indústrias, building and new energy applications

Anterior:

Próximo:

Deixe uma resposta

Deixe um recado