The product with the Siemens model number 6SL3210-1KE23-2UF1 belongs to the SINAMICS G120C Series of integrated frequency converters, which are primarily used for speed control and energy-efficient operation of three-phase AC motors. The following is a summary of the key information: Core Technical Parameters Power and VoltageNominal Power: 15.0 KW – Tensão de entrada: ...

  • Detalhes do produto

The product with the Siemens model number 6SL3210-1KE23-2UF1 belongs to the SINAMICS G120C Series of integrated frequency converters, which are primarily used for speed control and energy-efficient operation of three-phase AC motors. The following is a summary of the key information:

  1. Parâmetros técnicos principais
  2. Power and Voltage

Nominal Power: 15.0 KW

– Tensão de entrada: 380-480V (±10%/-20%), three-phase alternating current

– Capacidade de sobrecarga: 150% overload for 3 segundos.

  1. Interfaces and Communication

Integrated PROFINET interface supporting industrial Ethernet communication.

I/O Configuration: 6 digital inputs (DI), 2 digital outputs (DO), 1 analog input (AI), 1 analog output (AO).

For RS485 or DP interfaces, other models need to be selected (por exemplo, 6SL3210-1KE23-2UB1 supports USS/MODBUS, and 6SL3210-1KE23-2UP1 supports DP).

  1. Características Físicas:

– Classe de Proteção: IP20 (suitable for installation inside control cabinets).

– Dimensões: 295×140×225.4 mm (height × width × depth), supports side-by-side installation without derating.

Built-in filter complies with EN 61800-3 C2 standard (Class A).

  1. Cenários de aplicação

Industrial Manufacturing: Used for motor control of equipment such as conveyor belts, mixers, and extruders.

Building and Building Automation: Suitable for energy-efficient speed regulation of elevators, air conditioning systems, and water pumps.

Energy Management: Optimizes the operational efficiency of fans and compressors, reducing energy consumption.

III. Supply and Procurement

Spot Supply: Inventory is still available in the market in 2025. Por exemplo, Hebei China Electric can deliver within 3 dias, with a total supply of 1,000 unidades.

  1. Installation and Commissioning
  2. Installation Key Points

Shielding plates and EMC connection strips need to be installed to ensure electromagnetic compatibility. The built-in filter model should be selected according to actual requirements.

Power and motor connection terminals are pluggable, and the radiator fan can be easily replaced.

  1. Common Issues and Maintenance
  2. Fault Handling

Overvoltage Alarm (por exemplo, F0002): Check if the power supply voltage is within the allowable range (P0210), adjust the ramp-down time (P1121), or add a braking unit.

Communication Interface Issues: Select the correct model according to requirements (por exemplo, PROFINET, DP, or RS485) to avoid compatibility issues caused by mixing.

  1. Recomendações de manutenção

Regularly inspect the power supply board and power modules to prevent strong electrical interference with weak electrical circuits.

Ensure good heat dissipation, with the ambient temperature not exceeding 55°C (PROFINET models support side-by-side installation).

  1. Alternative Models and Upgrades

Communication Requirement Changes: For a DP interface, select 6SL3210-1KE23-2UP1; for RS485, select 6SL3210-1KE23-2UB1.

Function Expansion: For higher performance, consider the SINAMICS G120 modular frequency converter, which supports flexible configuration of control units and power modules.

VII. Official Support and Documentation

Technical Documentation: Detailed user manuals and parameter setting guides are available on the Siemens official website and can be obtained by searching for “6SL3210-1KE23-2UF1”.

After-Sales Service: Agents and the Siemens technical support team can provide installation guidance, firmware updates, and fault troubleshooting services.

It is recommended to confirm specific application requirements (such as communication protocols and environmental conditions) before procurement and contact the supplier for the latest quotations and technical support.

Especificações técnicas

  1. Parâmetros Básicos

Modelo: 6SL3210-1KE23-2UF1

Series: SINAMICS G120C Integrated Frequency Converter

Power Range: 15.0 KW

Supply Voltage: 3AC 380-480V (-20%/+10%)

Faixa de frequência: 47-63 Hz

Control Type: Vector Control (VC) / Vector Control with Encoder (VC+PG) / V/f Control

Classe de Proteção: IP20

Método de resfriamento: Forced Air Cooling

Dimensões: A4 (295 x 140 x 225.4 mm)

  1. Performance Indicators

Capacidade de sobrecarga:

Standard Type: 150% of rated current for 60 segundos

Enhanced Type: 180% of rated current for 3 segundos

Switching Frequency: 2-16 kHz (default 8 kHz)

Speed Regulation Range:

VC Control: 1:100

VC+PG Control: 1:1000

Speed Accuracy:

VC Control: ±0.5%

VC+PG Control: ±0.01%

  1. Input/Output Interfaces

Digital Inputs: 6 channels (default DI1-DI6), configurable as NPN/PNP

Digital Outputs: 2 channels (DO1-DO2), relay outputs

Entrada Analógica: 1 channel (AI1: 0-10V/0-20mA)

Saída Analógica: 1 channel (AO1: 0-20mA/0-10V)

Encoder Interface: Supports SIN/COS, TTL encoders

Communication Interfaces:

Integrated PROFINET interface (RT/IRT)

Optional CBP2 board (Profibus DP) or other communication expansion boards

  1. Power Supply and Power Consumption

Input Power:

Main Power: 3AC 380-480V, 50/60Hz

Control Power: 24VDC (built-in)

Consumo de energia: Approximately 150W

Efficiency: ≥98%

  1. Condições Ambientais

Temperatura operacional: -10°C to +50°C (derating required above 40°C)

Temperatura de armazenamento: -25°C a +70°C

Umidade: ≤95%, non-condensing

Altitude: ≤1000m (derating required above)

Pollution Degree: Aula 2

Características Funcionais

  1. Funções de controle

Modos de controle:

Vector Control (VC)

Vector Control with Encoder (VC+PG)

V/f Control (linear/square)

Speed Control: Supports PID control, closed-loop speed control

Torque Control: Supports Direct Torque Control (DTC)

Positioning Function: Simple positioning (up to 16 position points)

  1. Funções de proteção

Proteção contra sobrecarga: Electronic thermal overload protection (PTC/KTY84 optional)

Overvoltage/Undervoltage Protection: Automatic Voltage Regulation (AVR)

Short Circuit Protection: Dual hardware and software protection

Ground Fault Protection: Built-in ground fault detection

Motor Protection: Stalling protection, stall prevention, underload protection

  1. Communication Functions

PROFINET:

Supports RT/IRT real-time communication

Supports SINAMICS drive basic parameter file (GSDML)

Allows parameter setting and monitoring via PROFINET

Expanded Communication:

Supports Profibus DP via CBP2 board

Supports Modbus TCP via CM AC board

Supports Ethernet/IP, CANopen, etc.. via other expansion boards

  1. Operation and Monitoring

Operation Panel:

Basic Operation Panel BOP-2 (with 7-segment LED display)

Advanced Operation Panel AOP-30 (with LCD graphic display)

Parameter Setting:

Set via the operation panel

Use STARTER or StartDrive software via PC

Remote setting via communication interface

Monitoring Functions:

Real-time monitoring of parameters such as current, tensão, freqüência, e poder

Fault diagnosis and alarm recording (stores up to 100 fault messages)

  1. Special Functions

Energy-Saving Mode: Automatically optimizes the V/f curve to reduce no-load losses

Quick Commissioning Wizard: Simplifies the initial setup process

Ramp Function Generator: Supports S-curve and multi-speed control

Braking Function: Built-in braking chopper, supports dynamic braking

Safety Functions:

Safe Torque Off (STO) – Complies with SIL3/PLe

Optional safety expansion board supports SS1, SS2, SBC, etc..

  1. Application Macros

Built-in multiple application macros to simplify parameter setting:

Pump and Fan Macro

Conveyor Belt Macro

Hoist Macro

Compressor Macro

Custom Macro

  1. Instalação e Manutenção

Método de instalação: Wall-mounted installation

Side-by-Side Installation: Supports installation without spacing (requires EMC shielding plate)

Modular Design:

Separate control unit and power unit

Easy replacement of vulnerable parts (fãs, capacitors)

Firmware Upgrade: Supports firmware updates via USB or communication interface

Aplicações Típicas

Energy-efficient control of pump and fan loads

Speed control of conveyor belts and conveying systems

Precise control of mixers and mixing equipment

Constant torque control of extruders and compressors

Speed regulation of elevators and lifting equipment