M18 Flush-mount Inductive Proximity Switch (2-wire AC/DC universal, Normalmente aberto NÃO)
- Explicação do código do modelo
XS6: Uso geral inductive proximity sensor of XS6 series
18: M18 threaded cylinder
B: Standard sensing distance
1: Normalmente aberto (NÃO)
M: 2-wire AC/DC universal
UM: Saída de cabo
L2: 2-meter fixed cable
- Núcleo Elétrico & Especificações Mecânicas
| Item | Parâmetro |
| Nominal Sensing Distance Sn | 8 milímetros, montagem embutida (tipo blindado) |
| Tensão de alimentação | 24…240 V CA/CC (50/60Hz) |
| Tipo de saída | 2-arame, Normalmente aberto (NÃO) |
| Corrente de carga | CC: 5~200mA; AC: 5~300mA |
| Comprimento do corpo | 62 milímetros; Thread M18×1 |
| Material da Habitação | Latão niquelado; Sensing face PPS |
| Cabo | 2m cabo fixo |
| Classe de Proteção | IP68 / IP69K, double insulation |
| Temperatura operacional | -25℃ ~ +70 ℃ |
| Frequência de comutação | 1kHz |
| Detected Object | Metallic conductors (optimal for ferromagnetic metals) |
- Diretrizes de instalação
- Montagem embutida (Shielded Type): The sensor can be fully embedded inside a metal mounting seat without false triggering caused by side metal.
- Mounting hole M18, supplied with double lock nuts.
- Minimum spacing between adjacent sensors of the same model ≥3×Sn (≥24mm) para evitar interferência mútua.
- Target metal plate thickness ≥1mm, area ≥30×30mm for stable detection.
- Instruções de fiação
2-projeto de fio, não polarizado (CA/CC universal):
Connect two wires in series between power supply and load.
When metal approaches the sensing face → switch turns ON (NO contact closed).
Observação: 2-wire sensors carry standby leakage current. False actuation may occur with low-power loads (high-resistance relay coils). Load calculation is required during selection.
- Cenários típicos de aplicação
Metal detection on conveyor lines, machine tool limit positioning, detecção de presença de material, hydraulic/cylinder position feedback, food processing washdown equipment (IP69K for high-pressure cleaning), máquinas de embalagem.
- Alternativa / Equivalent Models within the Series
XS618B1MBL2: 2-wire Normally Closed NC, outros parâmetros idênticos
XS618B1PAM12: 3-fio PNP normalmente aberto, M12 connector type
XS618B1NAM12: 3-wire NPN Normally Open, M12 connector type
- Solução de problemas comuns
- Sem saída: Verify supply voltage within 24~240V; confirm metal target enters the 8mm sensing range; inspect cable for breakage.
- Falso acionamento: For flush mounting, ensure mounting metal does not cling to the sensing face; check interference from neighboring sensors.
- Cannot turn off: Too small load; leakage current of 2-wire sensor keeps relay energized. Replace with 3-wire PNP/NPN version.
Operating Principle of Flush-mount Inductive Proximity Switches (such as XS618B1MAL2)
Princípio Básico
Inductive proximity switches work based on the eddy current effect, with a high-frequency oscillating coil as the core component.
- Internal circuit generates a high-frequency alternating magnetic field, radiating outward from the front sensing face.
- Quando um alvo de metal se aproxima da face de detecção, the alternating magnetic field induces eddy currents on the metal surface.
- Eddy currents generate a reverse magnetic field to counteract the original oscillating magnetic field of the sensor.
- The amplitude of the oscillation circuit attenuates; detection circuit identifies this change and outputs switching signal (LIGADO/DESLIGADO).
✅ Core difference between Flush-mount (Blindado) and Non-flush (Não blindado): A metal shielding ring surrounds the coil
Structural Features of Flush-mount (Shielded Type)
A metal shielding layer wraps the sides of the sensing coil for flush-mount sensors:
Restricts magnetic field to directly in front of the sensor, nearly no magnetic field on lateral sides.
Portanto, it can be fully screwed into metal mounting brackets with sensor end face flush to mounting surface and no false triggering from surrounding metal.
Trade-off: Under identical specifications, sensing distance is shorter than non-flush type (Sn=8mm for XS618B1MAL2 flush model).
Tipo não nivelado: Magnetic field exists on sides; cannot be embedded in metal seat, otherwise continuous triggering occurs, with longer sensing distance.
Signal Output Flow (2-wire NO model XS618B1MAL2)
- Power on → internal oscillator starts oscillation.
- No metal nearby → stable oscillation, switch open (NÃO Normalmente aberto).
- Metal approaches and reaches rated sensing distance Sn → oscillation attenuates, detection circuit actuates and the 2-wire circuit conducts.
- Metal moves away → oscillation recovers, switch opens.
Características principais
- Only detects metal: Plástico, wood and glass cannot produce eddy currents and will not be detected. Ferromagnetic metals (aço, iron) deliver optimal sensing distance; effective distance attenuates for non-ferrous metals such as copper and aluminum.
- Velocidade de resposta rápida, suitable for high-speed counting and position detection.
- Flush mounting resists side metal interference, preferred for machine tools, conveyor metal frame installations.
- 2-wire version carries leakage current; load selection needs attention.
Simple Comparison Table
| Tipo | Estrutura | Mounting Feature | Distância de detecção |
| Montagem embutida (Blindado) | Coil with metal shielding ring | Can be flush embedded into metal holes | Mais curto |
| Não nivelado (Não blindado) | No side shielding | Cannot embed into metal; front clearance required | Longer |
Common Application Scenarios of Inductive Proximity Switches
Recursos principais: Detect metal only, non-contact, sem desgaste mecânico, resistant to dust and oil; Flush type (XS618B1MAL2) suitable for flush installation on metal frames
- Position Detection / Limite de viagem (Mais Comum)
- Cylinder position feedback: Detect extended/retracted end position of cylinder piston rod to confirm completion of cylinder action, standard fitting for pneumatic automation; M18 flush sensors widely used on cylinder mounting seats.
- Machine tool travel limit: Soft limit and hard overtravel protection for CNC machine slides and worktables; turret and tool magazine positioning, tool change confirmation; fixture clamping verification to judge workpiece seating status.
- Válvula, baffle and safety door status detection: Detect closure of metal safety gates for safety interlock; equipment startup prohibited when door open.
- Robot positioning: Homing and station in-place detection for robotic arms.
- Contando, Speed Measurement & Rotational Speed Monitoring
- Metal workpiece counting on conveyor lines: Count metal parts, parafusos, metal caps and metal pallets on production lines for output statistics.
- Rotational speed / line speed acquisition: Gear tooth disc fitted on motor shaft; proximity sensor detects gear teeth pulses, PLC collects pulses to calculate rotation speed and line speed, widely used for conveyors and reducer spindle monitoring.
- Material break / shortage detection: Monitor feeding of metal rods to confirm material delivery and breakage.
- Transporte & Classificação Logística
- Detect arrival of metal workpieces on belt conveyors to trigger cylinder actions for transfer and sorting;
- Metal pallet presence detection and rack positioning in automated warehouses;
- Jam monitoring: Alarm for material accumulation and blockage.
- Embalagem & Máquinas Alimentares (Suitable for XS618B1MAL2 with IP68/IP69K)
Detection of cans, metal caps and aluminum foil seals to verify cap presence;
Trigger filling when metal containers arrive at filling stations;
High-pressure washdown capability; flush sensors preferred for food & beverage cleaning lines.
- Fabricação Automotiva
Workpiece positioning at welding stations and fixture clamping confirmation for welded car bodies;
Gear position detection for gearboxes and presence check of wheel hubs;
Stable performance under welding slag and heavy dust; inductive sensors outperform photoelectric sensors in contaminated environments.
- Hidráulico & Máquinas de construção
Hydraulic cylinder position detection and metal float liquid level monitoring;
Position feedback for machinery doors and buckets;
Adapt to heavy vibration and oily harsh environments.
- Other Segmented Applications
- Equipamento de estampagem: Mold closure detection and safety interlock;
- Equipamento eletrônico: Metal component detection on SMT lines;
- Bombear & fã: Shaft stall monitoring via gear tooth speed measurement.
Dicas de seleção (For XS618B1MAL2)
✅ Flush-mount (Shielded Type): Can be installed flush within metal mounting seats, free from false triggering by surrounding metal; preferred for machine frames and cylinder mounts.
⚠️ Limitação: Only identifies metal, plástico, paper and non-metallic workpieces cannot be detected; effective sensing distance shortens for copper and aluminum.
⚠️ 2-wire models (por exemplo. XS618B1MAL2) have leakage current, which may cause false pull-in of small-load relays.
Telemecânica XS618B1 Series Full Model List (M18 Flush Mount, Sn=8mm)
Unified Base Specification: XS618B1 = XS6 series, M18 threaded, flush shielded type, nominal sensing distance 8mm, carcaça de latão niquelado, IP68/IP69K, -25~+70℃
Regra de codificação do modelo: XS618B1 + Código de saída + Tipo de saída + Length/Connector
M = 2-wire AC/DC; P=PNP; N=NPN
A=Normally Open NO; B=Normally Closed NC
L2=2m cable; L5=5m cable; M12=M12 circular connector; AU20=1/2″UNF connector
- 2-wire AC/DC (Branch of XS618B1MAL2, 24~240V CA/CC)
| Modelo | Saída | Fiação | Tomada | Observações |
| XS618B1MAL2 | NÃO | 2-arame | 2m cabo | Modelo de referência, Body L=62mm |
| XS618B1MBL2 | NC | 2-arame | 2m cabo | Same specs as MAL2 |
| XS618B1MAU20 | NÃO | 2-arame | 1/2″UNF connector | American thread connector, L=73mm |
| XS618B1MBU20 | NC | 2-arame | 1/2″UNF connector | Normally closed version with American connector |
- 3-fio CC PNP (12~48VDC, most common for PLC)
| Modelo | Saída | Fiação | Tomada | Observações |
| XS618B1PAL2 | NÃO | 3-wire PNP | 2m cabo | L=62mm |
| XS618B1PBL2 | NC | 3-wire PNP | 2m cabo | L=62mm |
| XS618B1PAL5 | NÃO | 3-wire PNP | 5m cabo | Long cable version |
| XS618B1PBL5 | NC | 3-wire PNP | 5m cabo | Long cable normally closed |
| XS618B1PAM12 | NÃO | 3-wire PNP | Conector M12 de 4 pinos | L=74mm |
| XS618B1PBM12 | NC | 3-wire PNP | Conector M12 de 4 pinos | L=74mm |
- 3-fio CC NPN (12~48VDC, for NPN-type PLC)
| Modelo | Saída | Fiação | Tomada | Observações |
| XS618B1NAL2 | NÃO | 3-wire NPN | 2m cabo | 62mm body |
| XS618B1NBL2 | NC | 3-wire NPN | 2m cabo | 62mm body |
| XS618B1NAM12 | NÃO | 3-wire NPN | Conector M12 | 74mm body |
| XS618B1NBM12 | NC | 3-wire NPN | Conector M12 | 74mm body |
- ATEX Dust Explosion-proof Versions (Explosive Atmosphere)
| Modelo | Saída | Fiação | Tomada | Observações |
| XS618B1PAL10EX | NÃO | PNP | 10m cabo | ATEX dust hazardous area |
| XS618B1PBL10EX | NC | PNP | 10m cabo | ATEX dust hazardous area |
Guia de seleção rápida
- 2-wire models starting with M (XS618B1MAL2): Universal AC/DC, no polarity distinction; ⚠️ leakage current exists, prone to false relay pull-in for tiny loads, adequado para cargas pesadas.
- 3-wire P/N prefix: DC12~48V, PNP/NPN, proteção contra curto-circuito, standard PLC selection, preferred replacement for 2-wire sensors.
- Suffix L2/L5: Fixed cable; M12/AU20: Detachable connector for easier maintenance.
- A=NO Normally Open, B=NC Normally Closed: When metal approaches, NO closes and NC opens.
Extended M18 Flush Models in the Same Series (Longer Sn, Non-B1)
XS618B4PAL2: Montagem embutida, Sn12mm, PNP NÃO, 2m cabo
Contator,disjuntor,sensor,Codificador,CLP,Conversor