Definirea segmentului de model

SegmentSensObservații
3*70Applicable cable specification3-cablu miez, conductor cross-section per core 70 mm²
QTIICod seria produsului3M 2nd generation pre-expanded cold shrink cable termination sistem (Quality Termination II)
94Product type codeOutdoor cold shrink termination, potrivit pentru 18/30 kV voltage level
EBInsulation material & structure codeSilicone rubber insulation with integrated stress control unit
63Conductor cross-section range codeSuitable for 50–150 mm² conductors (some versions fit 95–240 mm²)
4Core number & application codeSpecial for outdoor application of 3-core cables
  1. Parametrii de specificație de bază

Parametrii electrici

ParametruValoareDescriere
Tensiune nominală18/30 kV (Max 36 kV)Suitable for medium voltage power system
Max System Voltage24 kVCompliant with IEC standards
Applicable Cable TypeWire shield / Tape shield XLPE/EPR insulated power cableDedicated for polymer insulated cables
Insulation Outer Diameter Range21.3–35.0 mmTypical insulation outer diameter for 3×70 mm² cable
Power Frequency Withstand Voltage65 kV / 1 minFactory test standard
Partial Discharge≤10 pCHigh voltage performance index

Mecanic & Parametrii de mediu

ParametruValoareDescriere
Material de izolareHigh dielectric constant silicone rubberPermanent radial pressure, excellent weather resistance
Protecție la intrareIP68Fully dustproof and waterproof, suitable for harsh outdoor environments
Temperatura de operare-40℃ ~ +90℃Gamă largă de temperatură, adapts to extreme climates
Durată de viață mecanică≥30 yearsDesign fără întreținere, durata de viata lunga
Metoda de instalareCold shrink type (no heating tools required)Automatically shrinks by pulling out the support core rope
GreutateAproximativ. 1.2 kg/setComplete with all components, convenient for site installation

Applicable Cable Parameters

ParametruDomeniu de aplicareObservații
Conductor Cross-section3×50–150 mm²Some versions fit 3×95–240 mm²
Material conductorCopper / AluminumCompatible with two mainstream conductor materials
Insulation Thickness10–15 mmStandard insulation thickness for medium voltage cables
Shield TypeBraided copper wire shield / Wrapped copper tape shieldFits two common shielding structures
  1. Lista de accesorii
Nume accesoriuQtyScop
QTII Cold Shrink Termination Body (with integrated stress control)3 pcsProvide insulation and stress control
Silicone Rubber Insulation Tube3 pcsCable insulation restoration
Stress Control Mastic1 setStress control at branch joint and shield cut-off position
Sealing Mastic1 setTop sealing of termination
Cleaning Kit (CC-2)1 setPre-cleaning treatment for cable surface
Copper Mesh Grounding Wire3 pcsGrounding connection for shielding layer
Phase Color Marker (Yellow/Green/Red)3 setsPhase identification
Installation Instruction Manual1 copyDetailed installation guidance
Support Core Rope Pulling Tool1 pcAssist in pulling core rope during installation
  1. Competitor & Comparație între mărci
MarcaModelDiferența principalăScenariul aplicației
Original 3M94-EB63-3Indoor type, 18/30 kV, 3×25–150 mm²Indoor connection of medium voltage distribution equipment
Original 3M94-EB63-1Single-core outdoor type, 18/30 kV, 1×50–150 mm²Outdoor termination for single-core cable
ABBCold Shrink Termination SeriesSimilar structure, slightly higher price, same applicable rangePower system supporting, brand preference
SchneiderCold Shrink Termination SeriesDifferent stress control design, slight difference in installation stepsIndustrial automation system supporting
Alternativă internăChangyuan / Walen Cold Shrink TerminationPrice about 1/2–2/3 of 3M, performance meets national standardBudget-sensitive projects, non-critical circuits
  1. Ghid de selecție & Replacement Solutions

5.1 Key Selection Parameters

Voltage Level Matching: Confirm system voltage is 18/30 kV; not applicable for 12 kV or above 36 kV systems.

Cable Specification Confirmation:

Conductor cross-section: 3×70 mm² is well compatible within 50–150 mm² range.

Insulation outer diameter: Must be within 21.3–35.0 mm; otherwise replace model.

Shield type: Only for wire/tape shielded cables; not for non-shielded or aluminum sheathed cables.

Mediul de instalare:

Outdoor application: Alege 94 serie (outdoor type) with UV resistance and weatherability.

Indoor application: Select indoor type 94-EB63-3.

Installation Tools: No heating tools required; only basic electrician tools and cleaning supplies needed.

5.2 Soluții de înlocuire recomandate

Scenariul aplicațieiRecommended Replacement ModelAvantaje
Direct replacement with same specification3M 94-EB63-4 (50–150 mm² applicable)Original genuine, fully compatible
Large cross-section upgrade3M 94-EB63-4 (95–240 mm² applicable)Fits larger cross-section cables, reserved for future expansion
Indoor installation3M 94-EB63-3Dedicated indoor type, more compact structure
Cost optimizationChangyuan CYLS-30/3.1High-quality domestic alternative, obvious price advantage
Upgrade de performanță3M QTIII Series3rd generation cold shrink technology, fiabilitate mai mare

5.3 Precauții de instalare

  1. Cable Pre-treatment

Thoroughly clean cable surface with 3M CC-2 cleaning kit.

Keep smooth transition at shield cut-off to avoid tip discharge.

  1. Installation Procedure

Install branch joint sealing and stress control mastic first, then mount cold shrink termination body.

Pull the core rope steadily at constant speed to avoid termination distortion.

  1. Safety Regulations

Installers must hold medium voltage cable construction qualification.

Confirm cable power off and fully grounded before construction.

  1. Quality Control

Perform insulation test and partial discharge test after installation.

Record installation date and test data for future maintenance.

  1. Product Features Summary
  2. Maintenance-free Design: Silicone rubber provides permanent radial pressure without regular inspection.
  3. Instalare ușoară: Cold shrink technology requires no heating tools; single-person installation available.
  4. Fiabilitate ridicată: Integrated stress control unit effectively reduces partial discharge risk.
  5. Adaptabilitate puternică la mediu: -40℃~+90℃ operating temperature and IP68 rating suit various harsh environments.
  6. Wide Compatibility: Compatible with multiple specifications of XLPE/EPR insulated cables with high versatility.

3M Medium Voltage Cold Shrink Cable Termination Model List & Ghid de selecție

  1. Model Naming Rule Explanation

3M medium voltage cold shrink cable termination model consists of Series Code + Voltage Level + Mediul de instalare + Insulation OD / Conductor Cross-section + Core Number, clearly reflecting core parameters:

SegmentSensExemplu
QTII/QTIIIProduct generation seriesQTII = 2nd generation pre-expanded cold shrink; QTIII = 3rd generation cold shrink technology
56xx/76xxCod seria produsului56xx = QTII series; 76xx = QTIII series
94/7620/7680Voltaj & environment code94 = 18/30kV outdoor; 7620 = 15kV indoor; 7680 = 35kV outdoor
EB63/4-T/150Applicable range codeEB63 = fits 50–150mm²; 4-T = fits 23.4–30.0mm insulation OD
-0.75Core number code-3 = 3-core indoor; -4 = 3-core outdoor; -1 = single-core outdoor
-CN/-TIRegional / Special mark-CN = China market; -TI = Special insulation type adaptation
  1. Prezentare generală a seriei de produse

3M medium voltage cold shrink cable terminations are mainly divided into two core series: QTII (2nd Gen) and QTIII (3rd Gen), covering 5–35kV voltage level, single-core/3-core, full indoor/outdoor applications.

SerieGenerationGama de tensiuneCaracteristici de bazăAplicație tipică
QTII 5600 Serie2nd Gen5–35 kVPre-expanded cold shrink, silicone rubber insulation, integrated stress controlGeneral medium voltage distribution system, rentabil
QTIII 7600 Serie3rd Gen5–35 kVGrease-free, lower partial discharge, fiabilitate mai mareCritical distribution circuits, high reliability required occasions
QTII 5680 Serie2nd Gen18/30–26/35 kVOutdoor type, UV resistance, superior weatherabilityOutdoor cable termination for 18/30kV and above
QTIII 7690 Serie3rd Gen5–35 kVInverted shed design, anti-pollution flashover, suitable for heavily polluted areasCoastal / industrial area outdoor application
  1. Detailed Model List

3.1 QTII Series (2nd Gen Cold Shrink, 5600 Serie)

3.1.1 18/30kV (24kV) Outdoor Type (94 Serie)

Caracteristici de bază: Silicone rubber insulation, with rain shed, integrated stress control, suitable for wire/tape shielded XLPE/EPR cables

ModelApplicable Cable SpecInsulation OD RangeCore TypeObservații
94-EB63-43×50–150 mm²21.3–35.0 mm3-core OutdoorMost common model for 3×70mm² cable
94-EB63-33×50–150 mm²21.3–35.0 mm3-core IndoorNo rain shed, indoor dedicated
94-EB63-11×50–150 mm²21.3–35.0 mmSingle-core OutdoorOutdoor termination for single-core cable
94-EB64-43×95–240 mm²28.0–45.0 mm3-core OutdoorPentru cabluri cu secțiune mare
94-EB64-11×95–240 mm²28.0–45.0 mmSingle-core OutdoorOutdoor termination for large single-core cable

3.1.2 8.7/15kV (20kV) Serie

Caracteristici de bază: Suitable for 15kV system, compact structure, instalare ușoară

ModelApplicable Cable SpecInsulation OD RangeMediul de instalare
5601PST-G-CN3×35–70 mm²16.0–28.0 mmIndoor / Outdoor
5602PST-G1-CN3×95–150 mm²21.0–35.0 mmIndoor / Outdoor
5602PST-G2-CN3×185–240 mm²28.0–45.0 mmIndoor / Outdoor
5603PST-G-CN3×300–500 mm²35.0–55.0 mmIndoor / Outdoor
5620K1×35–400 mm²16.0–45.0 mmSingle-core Outdoor

3.1.3 26/35kV (40.5kV) Serie

Caracteristici de bază: Suitable for 35kV system, high insulation performance, corona resistance design

ModelApplicable Cable SpecInsulation OD RangeCore Type
56821×50–150 mm²21.0–35.0 mmSingle-core Outdoor
56841×95–240 mm²28.0–45.0 mmSingle-core Outdoor
56833×50–150 mm²21.0–35.0 mm3-core Outdoor
56853×95–240 mm²28.0–45.0 mm3-core Outdoor

3.2 QTIII Series (3rd Gen Cold Shrink, 7600 Serie)

Avantajele de bază: Grease-free, lower partial discharge (≤5pC), integrated environmental sealing, easier installation

3.2.1 8.7/15kV (20kV) Serie

ModelApplicable Cable SpecInsulation OD RangeMediul de instalareCaracteristici
7620-S-33×35–70 mm²16.0–28.0 mm3-core IndoorNo rain shed, indoor use
7620-S-43×35–70 mm²16.0–28.0 mm3-core OutdoorWith rain shed, outdoor use
7620-S-11×35–70 mm²16.0–28.0 mmSingle-core IndoorSingle-core indoor termination
7620-S-21×35–70 mm²16.0–28.0 mmSingle-core OutdoorSingle-core outdoor termination
7693-S-4-3G3×95–150 mm²23.4–30.0 mm3-core OutdoorFor medium cross-section cables

3.2.2 18/30kV (24kV) Serie

ModelApplicable Cable SpecInsulation OD RangeMediul de instalareObservații
7642-T-1103×50–150 mm²21.3–35.0 mm3-core OutdoorReplacement for QTII 94-EB63-4
7642-T-1503×95–240 mm²28.0–45.0 mm3-core OutdoorReplacement for QTII 94-EB64-4
7642-T-11×50–150 mm²21.3–35.0 mmSingle-core OutdoorSingle-core outdoor termination

3.2.3 26/35kV (40.5kV) Serie

Caracteristici de bază: High voltage level, anti-pollution flashover design, potrivit pentru medii dure

ModelApplicable Cable SpecInsulation OD RangeMediul de instalareCaracteristici de design
7680-S-43×50–150 mm²21.0–35.0 mm3-core OutdoorStandard rain shed design
7680-S-11×50–150 mm²21.0–35.0 mmSingle-core OutdoorStandard rain shed design
7690-S-INV-3RJS3×95–240 mm²28.0–45.0 mm3-core OutdoorInverted shed, anti-pollution flashover
7695-T-1503×300–500 mm²35.0–55.0 mm3-core IndoorPentru cabluri cu secțiune mare

3.3 Seria de aplicații speciale

3.3.1 High Fault Current Series

Caracteristici de bază: Suitable for high short-circuit current system, enhanced insulation design

ModelVoltage LevelApplicable Cable SpecCaracteristici
7650-S-HSG5–35 kV1×50–240 mm²Single-core with connector
7660-S-HSG5–35 kV3×50–240 mm²3-core with connector

3.3.2 Special Cable Adaptation Series

Caracteristici de bază: Suitable for JCN cables (sheath concentric neutral) and special shielding structure cables

ModelVoltage LevelApplicable Cable TypeInsulation OD Range
7654-S-4-TI5–25/28 kVJCN Cable21.1–38.9 mm
7654-S-1-TI5–25/28 kVJCN Cable21.1–38.9 mm
  1. General Specification Comparison Table

General Electrical Parameters (All Series)

ParametruValoareDescriere
Material de izolareHigh dielectric constant silicone rubberPermanent radial pressure, excellent weather resistance
Protecție la intrareIP68Fully dustproof & waterproof for harsh outdoor conditions
Temperatura de operare-40℃ ~ +90℃Wide temperature range for extreme climates
Viața mecanică≥30 yearsMaintenance-free long service life
Metoda de instalareCold shrink type (no heating required)Self-shrinking by pulling support rope
Partial DischargeQTII: ≤10 pCHV performance index; QTIII better
QTIII: ≤5 pC
Power Frequency Withstand Voltage2.5× rated voltage / 1 minFactory acceptance test standard

Series Key Parameter Comparison

SerieRated Voltage RangeApplicable Conductor Cross-sectionInsulation OD RangeInstallation EnvPrice Level
QTII 94 Serie18/30 kV50–240 mm²21.3–45.0 mmIndoor/OutdoorMid-to-high
QTII 5600 Serie8.7/15 kV35–500 mm²16.0–55.0 mmIndoor/OutdoorMid-range
QTII 5680 Serie26/35 kV50–240 mm²21.0–45.0 mmOutdoorHigh-end
QTIII 7620 Serie8.7/15 kV35–150 mm²16.0–30.0 mmIndoor/OutdoorMid-to-high
QTIII 7640 Serie18/30 kV50–240 mm²21.3–45.0 mmIndoor/OutdoorHigh-end
QTIII 7680 Serie26/35 kV50–500 mm²21.0–55.0 mmIndoor/OutdoorPremium
  1. Ghid de selecție & Replacement Solutions

5.1 Key Selection Parameters

Voltage Level Matching

8.7/15kV system: Alege 5600 / 7620 serie

18/30kV system: Alege 94 / 7640 serie

26/35kV system: Alege 5680 / 7680 serie

Cable Specification Confirmation

Conductor cross-section must fall within model applicable range.

Insulation outer diameter strict matching; tolerance ≤±1mm.

Only for XLPE/EPR cables with copper wire/tape shield.

Installation Environment Selection

Outdoor: Select models with rain shed (suffix -4/-2), UV resistant.

Indoor: Select non-rain shed type (suffix -3/-1), compact structure.

Heavily polluted area: Prioritize QTIII 7690 series with inverted shed design.

5.2 Replacement Recommendation Table

Model originalÎnlocuire directăUpgrade ReplacementCost-Effective Alternative
94-EB63-47642-T-110 (QTIII)7693-S-4-3G (Anti-pollution)Changyuan CYLS-30/3.1
5601PST-G-CN7620-S-3 (QTIII)7620-S-4 (Outdoor Type)Walen WRS-15/3.1
56827680-S-1 (QTIII)7690-S-INV (Inverted Shed)Domestic 35kV Cold Shrink Termination

5.3 Note de instalare

  1. Cable Pre-treatment

Clean cable surface thoroughly with 3M CC-2 cleaning kit.

Smooth transition at shield cutting position to avoid corona discharge.

  1. Etape de instalare

QTII series: Install branch sealing & stress mastic first, then termination body.

QTIII series: Integrated design, no extra stress mastic needed, simpler installation.

  1. Safety Regulations

Installers must hold valid medium voltage cable construction qualification.

Ensure cable de-energized and grounded before work.

  1. Quality Control

Conduct insulation resistance test and partial discharge test after installation.

Record installation date and test data for later maintenance.

  1. Difference between QTII and QTIII Series

QTIII is 3rd generation technology, grease-free, lower partial discharge (≤5pC), easier installation; price about 20% higher than QTII.

  1. How to select correct insulation outer diameter range

Measure actual cable main insulation outer diameter, select the smallest model covering the measured size to ensure sufficient radial compression.

  1. Interchangeability of indoor and outdoor types

Outdoor type can be used indoors; indoor type cannot be used outdoors (no rain shed, insufficient protection).

  1. Difference for copper core vs aluminum core cable

3M medium voltage cold shrink terminations fit both copper and aluminum conductors without special model selection.