Material nr.: 97720906|Grundfos SMART Digital DDE Economy Digital Diaphragm Dosing Pompa (Acționat cu motor pas cu pas)

Defalcarea codului de model

DDE 6-10 B-PP/E/C-X-31I001FG

  1. DDE: Serie, economy digital dosing pump (basic model, differs from premium DDA/DDC)
  2. 6: Debit maxim 6 L/h
  3. 10: Max working pressure 10 bar
  4. B: Control version = Basic, manual adjustment + pulse signal input control
  5. PP: Pump head material = Polypropylene
  6. E: Seal material = EPDM (ethylene propylene diene monomer, resistant to water, weak acids & weak alkalis)
  7. C: Ball material = Ceramic
  8. X: Valve type = Standard double ball valve (non-spring-loaded)
  9. 31I001: Voltaj / regiune / connection code: 230V 50Hz, I = Australia & New Zealand specification, 4/6mm hose connection
  10. FG: Cable and certification configuration code

Date tehnice de bază

Max flow: 6 L/h; Min flow: 6 mL/h

Turn-down ratio: 1:1000, logarithmic adjustment knob 0.1~100% continuous regulation

Conduce: Stepper motor, full-stroke operation, stable dosing even with aerated media

Diafragmă: Solid PTFE diaphragm

Repeat accuracy: ≤5%

Clasa de protectie: IP65 / NEMA 4X

Max medium viscosity: 50 mPa·s

Built-in air vent valve for easy priming

Control modes: Local manual, external pulse input (dividable)

Certificari: CE, CSA-US, NSF61, EAC, RCM

Aplicații tipice

Tratarea apei (raw water, ape uzate, apa cazanului, apa de racire circulanta), RO & ultrafiltration, swimming pools, light chemical dosing, sodium hypochlorite, acid & dozarea alcaline (subject to EPDM chemical compatibility)

Nota: EPDM is not suitable for strong oxidants, concentrated chlorine or aromatic solvents. For high-chlorine applications, select V (FKM) versiune.

Equivalent Series Reference (pentru selecție & înlocuire)

DDE 6-10 B-PP/V/C-X-31I001FG: PP pump head + Garnituri FKM (sodium hypochlorite resistant)

DDE 6-10 B-PVC/E/C-X-31I001FG: PVC pump head + EPDM seals

DDE 6-10 B-PV/T/C-X-31I001FG: PVDF pump head + PTFE seals (heavy corrosion)

Accesorii optionale (Kit de instalare)

Foot valve, injection valve, PE discharge tubing, PVC suction tubing, vent tubing, compression fittings (4/6mm hose)

Spare Parts List for DDE 6-10 B-PP/E/C-X-31I001FG (97720906)

Pump configuration: PP pump head + EPDM seals + ceramic ball valves (SD-S-1-PP/E/C-2, S-series for 6~9L/h flow range)

Complete Repair Kit (Cele mai populare, Full Set)

97751105|Pump Head Repair Kit SD-S-1-PP/E/C-2

Contains:

  1. PTFE composite main diaphragm
  2. Suction valve assembly (ceramic ball + EPDM seat seal)
  3. Discharge valve assembly (ceramic ball + EPDM seat seal)
  4. Pump head O-rings and small sealing gaskets
  5. Fixing screws, shims and air vent components

Compatible with DDE 6-10 and equivalently configured DDA 6–9L/h, PP/E/C combination

Mementouri: Grundfos S-series (≤15L/h) does not supply loose individual balls or diaphragms as standalone OEM part numbers. Factory supply prioritizes complete valve kits or diaphragm+valve kits; loose single parts on the market are mostly aftermarket.

Split Kits (Separate Procurement If Required)

  1. Valve Kit (suction + discharge valves only, no diaphragm)

Cod: SD-S-PP/E/C-2 valve assembly (8-digit material number to be retrieved via Grundfos channel using pump PN 97720906)

Cuprins: 2 sets of valve assemblies (Al₂O₃ ceramic ball + EPDM valve seals)

  1. Diaphragm Only Kit (PTFE diaphragm only, no valves)

Cod: SD-S-1-PP diaphragm kit, also retrieved by pump serial/material number

Material Breakdown (Cross-check for replacements)

Diafragmă: PTFE faced diaphragm with support flange

Valve ball: Al₂O₃ alumina ceramic ball

Valve seat O-ring / main pump head O-ring: EPDM (E code)

Pump head body: Polipropilenă (PP)

If upgraded to sodium hypochlorite resistant version (V=FKM), repair kit PN will change and cannot be interchanged.

Cross-reference for different material sets (stocking reference)

PP/V/C (FKM seal for chlorine): Different repair kit PN from 97751105

PVDF/T/C (PTFE seal for heavy corrosion): Separate SD-S-PVDF/T/C-2 valve kit

PVC/E/C: Dedicated repair kit PN for PVC pump head variant

Grundfos DDE 6-10 B-PP/E/C-X-31I001FG Troubleshooting Guide

Applicable to DDE economy digital diaphragm dosing pump, PP pump head + EPDM seal + ceramic ball valve configuration

Precauție: Isolate power before service. Wear protection for corrosive chemicals; ensure ventilation for hypochlorite, acid and alkali media.

  1. Vina: Pump runs, no suction / no chemical output
SimptomCauza posibilaVerifica & Remediu
Stepper motor runs normally, stroke action visible, no dischargeAir trapped inside pump head, insufficient priming1. Open manual air vent valve on pump head;2. Keep suction hose fully submerged to drain air from piping;3. Cycle pump at low flow to purge bubbles; close vent after air removed
Air leakage on suction side (cel mai frecvent)Inspect foot valve, hose ferrules, cracked tubing;Ageing / kinked PE tubing or loose fittings leak air;Submerge foot valve ≥10cm below liquid level; avoid suction pipe above tank liquid level
Suction/discharge valve stuck, ball stuck or fouledDismantle valve assemblies, clean ceramic balls and EPDM seats;Dirt, scale or crystals prevent tight sealing;Inspect balls for chipping or cracking
Foot valve clogged / foot valve check valve failedRemove and clean foot valve strainer; replace foot valve if worn or jammed
Diaphragm rupturedCheck vent port and pump housing for chemical leakage;Medium entering drive chamber means diaphragm failure; shut down and replace repair kit
Excessive suction liftDDE has limited self-priming capability; flood suction side preferred (tank above pump); vertical suction lift ≤2m
Medium viscosity out of rangeViscosity >50 mPa·s exceeds pump specification, poor priming
  1. Vina: Inaccurate flow, low/high actual output, flow drift
SimptomCauza posibilaVerifica & Remediu
Metered flow deviates from setpoint, persistently low flowAir ingress or poor valve sealing (same as above leakage issues)Perform air purge and suction side leak test first; this is the #1 cause of flow inaccuracy
Valve ball / seat wear, crystal buildup, poor sealingDismantle and clean valve assemblies; EPDM ages and swells under continuous high chlorine exposure – replace repair kit
Diaphragm fatigue, reduced swept volumeDiaphragm creep after long runtime; replace full repair kit
Unstable outlet backpressure, backpressure too lowInstall backpressure valve on dosing pump outlet; free flow siphoning occurs without backpressure valve, causing uncontrolled flow;This pump rated 10 bar; continuous low-pressure siphoning leads to over-dosing
Pulse control mode: wrong pulse scaling or faulty signal sourceVerify pulse ratio and scaling parameters for external pulse control;Switch to local manual mode to isolate pump fault vs controller signal fault
Changing chemical temperature or crystallisationTemperature changes alter density; crystals accelerate valve wear and gradual flow decay
Calibration lostRe-calibrate by timed volumetric collection and re-set calibration on pump panel
  1. Vina: Zgomot anormal, vibratie
SimptomCauza posibilaVerifica & Remediu
Regular tapping / clicking sound with unstable dischargeBall hammering seat (typical air-bound noise)Purge air first; cavitation causes dry ball impact noise
Crapat / chipped ceramic ballDisassemble valve set; replace valve kit if ceramic ball damaged
Hum from motor, vibrații puternice, intermittent outputPiping resonance, loose hose supportsAdd pipe clamps; avoid rigid hard pipe tension pulling pump inlet/outlet
Pump installed off-level, pump head under stressMount pump horizontally; prevent hose tension pulling pump head
Stepper motor overload, diaphragm jammedDDE has no manual crank; energise and observe stroke movement;Jammed crystals or debris on diaphragm increase load
Intermittent high-pitched whistlingOver-restriction / dead-head pressure or cavitationCheck for blocked outlet piping or clogged injection valve; clean injection check valve
  1. Other Common Faults
  2. Display normal, no pumping action at all

Power supply fault / subtensiune; check 230V supply and loose terminals

Keypad lock active; unlock panel

  1. Leakage at pump head

Aged pump head O-rings, uneven bolt torque; tighten pump head bolts diagonally and evenly

Ruptured diaphragm with chemical leaking into drive side → stop immediately, replace repair kit

  1. Continuous dripping from air vent

Worn vent valve seal; replace vent valve component or full repair kit

Recommended Diagnostic Sequence

  1. Confirm power supply and control mode (local / puls)
  2. Vent air → inspect suction side for air leaks
  3. Volumetric flow test to confirm true pump fault or signal issue
  4. Dismantle and inspect valve assemblies, ceramic balls and EPDM seals
  5. Inspect diaphragm for rupture and leakage
  6. Check outlet backpressure valve and injection valve for blockage or failure
  7. Final action: replace complete pump head repair kit (97751105)

Siguranţă & Note de întreținere

For crystallising media (PAC, phosphate, high brine), flush pump head and valves with clean water after shutdown to prevent seizure

EPDM seals are not suitable for long-term high-concentration sodium hypochlorite service; use V variant (FKM) for chlorine dosing

Tighten pump head bolts diagonally and evenly; uneven torque can crack PP pump head

Grundfos SMART Digital DDE Series List (S-series ≤15L/h Economy Range)

Important separation: S-series small flow DDE (6-10 /15-4) (the model above); separate XL large flow DDE (60/120/200 L/h). Spare parts are NOT interchangeable.

Control variants exclusive to DDE: B / P / PR

B: Basic|manual adjustment + pulse input (your unit: DDE 6-10 B)

P: B + external start/stop + low-level input

PR: P + relay alarm output (stroke signal, releu de eroare)

  1. S-series DDE (low flow 0–15 L/h, utilizat pe scară largă) Base Models
Model de bazăDebit maximPresiune maximăTurn-down RatioMin Flow
DDE 6-106 L/h10 bar1000:01:000.006 L/h (6 mL/h)
DDE 15-415 L/h4 bar1000:01:000.015 L/h (15 mL/h)

Full model format:

DDE Flow-Pressure Control Code-Pumphead/Seal/Ball-Valve Type-Voltage Region Code FG

Exemplu: `DDE 6-10 B-PP/E/C-X-31I001FG`

Material Combinations (Pumphead / Sigiliu / Ball)

PP/E/C: PP pump head + EPDM seal + ceramic ball (your configuration, fresh water, weak acid/alkali)

PP/V/C: PP pump head + Sigiliu FKM + ceramic ball (sodium hypochlorite, chlorine media)

PVC/E/C: PVC pump head + EPDM seal + ceramic ball

PVC/V/C: PVC pump head + Sigiliu FKM + ceramic ball

PVDF/T/C: PVDF pump head + PTFE seal + ceramic ball (strong acid / heavy corrosion)

PP/E/SS: PP + EPDM + stainless steel ball (special abrasion service)

Valve Type Codes

X: Standard double ball valve (non-spring-loaded, scop general)

H: Spring-loaded valve (unstable backpressure, high viscosity media)

Voltaj / Region Codes (Comun)

31I001: 230V 50Hz, RCM AU/NZ, 4/6mm hose compression (your unit)

31U2U2: 100–240V universal voltage, CE, EU specification

31V: 110V North America version

S-series Finished Model Examples (Direct for PO)

  1. DDE 6-10 B-PP/E/C-X-31I001FG (PN 97720906|your pump)
  2. DDE 6-10 B-PP/V/C-X-31I001FG (chlorine resistant same rating)
  3. DDE 6-10 PR-PP/V/C-X-31U2U2FG|alarm relay, tensiune universală
  4. DDE 15-4 B-PP/E/C-X-31I001FG|15L/h 4bar, EPDM
  5. DDE 15-4 P-PVDF/T/C-X-31U2U2FG|PVDF heavy corrosion, controlul pulsului
  6. SMART Digital XL DDE (Large Flow 60~200 L/h, independent range)

XL pump head structure and repair kits are incompatible with S-series 6-10 /15-4

| DDE 60-10 | 60 L/h | 10 bar |

| DDE 120-7 | 120 L/h | 7 bar |

| DDE 200-4 | 200 L/h | 4 bar |

XL example:

DDE 60-10 B-PP/V/C-F-31U3U3FG

  1. DDE Control Variant Function Table
Cod de controlManual AdjustmentPulse InputExternal Stop / Low LevelRelay Alarm Output
B✅✅❌❌
P✅✅✅❌
PR✅✅✅✅ (2 relee)
  1. Diferențierea seriei (Avoid mixing with DDC / DDA)

DDE: Economie, basic function, no 4-20mA analog input, rentabil (OEM water treatment standard)

DDC: Clasa standard, 4-20mA analog, extended menu, additional alarms

DDA: Premium grade, built-in FCM flow monitoring, precizie ridicată, batch dosing, complex interlock

  1. Spare Part Cross-reference Summary

S-series (6-10 /15-4): Repair kit family SD-S-1-xxx, PN 97751105 for PP/E/C

XL series (60/120/200): Dedicated XL repair kits, nu sunt interschimbabile

  1. Quick Selection Guidance
  2. Sodium hypochlorite / chlorine dioxide dosing: prefer `/V/` (FKM), avoid EPDM `/E/`
  3. Concentrated acid / heavy corrosion: PVDF `/T/`
  4. Unstable backpressure or siphon risk: select H spring-loaded valve instead of X standard valve
  5. Standard domestic global supply: prefer 31U2U2 universal voltage; AU/NZ export use 31I001