Catalog Code Breakdown
| Segment | Definiţie |
| 2080 | Family code for Micro800 series |
| LC20 | Micro820 CPU unit |
| 20 | Total native I/O count: 20 puncte |
| Q | Tip ieșire: Ieșire tranzistor (NPN Sinking) |
| B | Alimentare electrică: 24Intrare VDC |
| B | Tip de intrare: 24VDC digital input |
Native I/O Allocation (20 Puncte)
Intrări: 12-point DC24V Digital Inputs
Terminals I-00~I-11, sinking/sourcing compatible (configurable)
Ieșiri: 8-point DC24V NPN Transistor Outputs
Terminals O-00~O-07, NPN transistor type. AC loads cannot be driven directly.
⚠️ Distinction:
2080-LC20-20QBB = NPN transistor output
2080-LC20-20QBBR = Relay output version
Specificații tehnice cheie
- Alimentare electrică: 24 VDC (domeniul de operare:18~30 VDC)
- Memoria programului: 10K instructions
- Variable Memory: 10K bytes
- Interfețe de comunicare
USB (programming port)
Embedded RS485 (Modbus RTU Master/Slave)
- Capacitate de extindere
✅ Supports Micro800 plug-in modules (analog I/O, RTD/TC, high-speed counter, serial modules)
✅ Maximum 4 plug-in modules can be installed
- Funcții de mare viteză
4-channel High-Speed Counter (HSC), max. 100kHz
4-channel Pulse Train Output (PTO), max. 100kHz for basic positioning control
- Evaluări de mediu
Temperatura de functionare: 0 ~ 55 ℃
Temperatura de depozitare: -40 ~ 85 ℃
Clasa de protectie: IP20, cabinet mounting only
Cerință software
Software de programare: Connected Components Workbench (CCW)
Minimum supported version: CCW V8.0 and above
Aplicații tipice
Small conveying equipment, mașini de ambalare, ventilator & controlul pompei, custom automated tooling, control HVAC, basic stepper/servo positioning systems.
Ghid de selecție & Common Pitfalls
- NPN sinking transistor output: Load negative wire connects to PLC output terminal; AC loads cannot be driven directly. Use DC24V solenoid valves preferentially.
- Fără port Ethernet încorporat! Ethernet communication requires additional Ethernet plug-in module (de ex. 2080-EWEB).
- Freewheeling diodes are recommended for inductive loads to avoid transistor breakdown caused by back EMF.
- Micro820 does not support remote I/O, only local plug-in expansion available.
Înlocuiri directe & Comparație de serie
Same I/O count relay variant: 2080-LC20-20QBBR
Higher I/O capacity: Upgrade to Micro830 (2080-LC30 series)
Complete Reference for 2080-LC20-20QBB
(Terminal Wiring + Modbus RTU Configuration + PTO Program + Depanare + Cod HS)
- Hardware Terminal Definition & Ghid de cablare
Model: Micro820 2080-LC20-20QBB
Alimentare electrică: DC24V; DIN:12-channel DC24V; DO:8-channel NPN Sinking Transistor Output
⚠️ Embedded serial port: Shared RS485/RS232 without galvanic isolation
1.1 Terminale de alimentare (PLC Main Power)
| Terminal Label | Definiţie | Instrucțiuni de cablare |
| 0 | Positive power input | Connect to DC24V+ |
| 0 | Negative power input | Connect to DC24V 0V/GND |
1.2 Terminale de intrare digitală (12 DIN: eu-00 ~ I-11)
Terminal comun: CM0
Sinking Wiring (Cele mai comune): CM0 connected to DC24V+; NPN sensor output to I-xx; sensor negative to 0V
Sourcing Wiring: CM0 connected to 0V; PNP sensor output to I-xx; sensor positive to DC24V
eu-00, eu-01, eu-02, eu-03: Dedicated high-speed counter channels
DI Terminal List:
eu-00, eu-01, eu-02, eu-03, eu-04, eu-05, eu-06, eu-07, eu-08, eu-09, I-10, I-11
1.3 Terminale de ieșire digitală (8 DO O-00 ~ O-07, NPN)
Terminal comun: -CM0
✅ NPN Sinking characteristic: Terminal O-xx approximates 0V when energized
Standard Wiring Scheme:
+DC24V → Load positive terminal; Load negative terminal → O-xx; All -CM0 terminals tied to DC24V 0V
O-00, O-01: PTO pulse output channels (de mare viteză)
Freewheeling diode must be reverse-paralleled for inductive loads (electrovalve)
DO Terminal List: O-00, O-01, O-02, O-03, O-04, O-05, O-06, O-07
1.4 Embedded RS485/RS232 Serial Terminal (6-pin terminal block)
| Pin | Semnal | Funcţie |
| 6 | SG | Signal Ground (common ground mandatory) |
| 7 | TX/R1OUT | RS485-B / RS232 TXD |
| 8 | RX/R2IN | RS485-A / RS232 RXD |
RS485 Wiring: Pin7(B) ↔ Device B terminal; Pin8(O) ↔ Device A terminal; Pin6 shared ground
❗ No galvanic isolation on this port. Install isolated repeater for long-distance communication.
- Step-by-step CCW Modbus RTU Configuration (Master/Slave Supported)
Software: Connected Components Workbench CCW V8.0 and above
Step1: Project Hardware Configuration
- Create new project → Select controller 2080-LC20-20QBB
- Double-click [Controlor] on left pane to open configuration page → Locate [Serial Port]
- Driver selection: Modbus RTU
Step2: Communication Parameters (Recommended Defaults)
| Parametru | Valoare recomandată | Observații |
| Rata baud | 19200 | Adjust to 9600/38400 după cum este necesar; both sides must match |
| Data bits | 8 | Fix |
| Stop bits | 1 | Fix |
| Paritate | Nici unul | No parity |
| Mode | RS485 | Match hardware wiring |
| Role | Slave / Master | Select based on system architecture |
| Slave Address | 1~247 | Valid only under Slave mode |
Step3: Register Mapping (Critical Section)
Modbus address mapping rule for Micro820
Coils (0x addresses): PLC BOOL variables
Discrete Inputs (1x addresses): Read-only BOOL status
Holding Registers (4x addresses): INT/DINT (Read & Write, cel mai utilizat)
Input Registers (3x addresses): Read-only INT values
Notă importantă: Micro800 series does not support automatic tag mapping for Modbus. Use function blocks for master read/write operations:
`MODBUS_READ` / `MODBUS_WRITE`
- PTO Pulse Positioning Control (O0/O1 Pulse Output for Stepper/Servo)
Hardware Channel Assignment
PTO0: Pulse Output → O-00; Direction signal recommended on O-02
PTO1: Pulse Output → O-01; Direction signal recommended on O-03
Max output frequency: 100kHz
Output type is NPN sinking. Servo drive pulse input setting must be low-level active / sinking input
CCW Configuration Workflow
- Controller Configuration → Enable [Ieșire impuls (PTO0)]
- Set maximum frequency: 100000 Hz; Acceleration/Deceleration time: 500Domnișoară
- Call motion function block `PTO_RUN` inside program
Structured Text Example: Relative Positioning
⚠️ Critical Limitation: Micro820 does not support electronic cam or multi-axis synchronization; only basic point-to-point positioning available.
- High-Speed Counter (HSC) Configurare (I0~I3)
4 independent HSC channels, support single-phase input & quadrature encoder with 4x multiplication
Common operation modes:
Mode0: Single-phase up-counting
Mode4: Quadrature encoder, 4x frequency multiplication mode
- Cablaj & Selection Hard Rules (Risk Avoidance)
- 2080-LC20-20QBB = NPN sinking output. AC loads cannot be driven directly. Add intermediate relays for AC loads.
- Do not overload transistor outputs continuously: 0.3A per point maximum (ambient temperature 55℃)
- RS485 port non-isolated. Communication errors easily occur under multi-ground power supply systems; implement shared ground or galvanic isolation.
- No native Ethernet port. Install plug-in module 2080-EWEB if Ethernet connection is required.
- Maximum 4 plug-in modules supported. Remote I/O expansion is not available.
- Use shielded cables for pulse wiring; route away from power cables of contactors and inverters to reduce interference.
- HS Code Reference for Import & Export Customs Declaration
8537101100
Descriere: Controler logic programabil (PLC)
⚠️ Reference only. Confirm classification with local customs authority before formal customs clearance.
- Matricea de depanare comună a erorilor
| Fenomen de eroare | Cauza de bază | Soluţie |
| No PTO pulse output | Pulse signal mismatch; Output common terminal not connected to 0V | Switch drive to sinking input; Verify -CM0 wiring |
| Intermittent Modbus communication | Missing signal ground; Excessive cable length; No terminating resistor | Connect SG pin on both ends; Adăuga 120 terminating resistor |
| False triggering of digital inputs | Sensor cable interference; Incorrect CM0 wiring | Deploy shielded cable; Verify sinking/sourcing configuration |
| PLC restarts repeatedly after power-on | Insufficient DC24V power rating, excessive ripple | Replace power supply with minimum 3A capacity |
- Official Manual Reference
Manual de utilizare: 2080-UM005E-EN-E (Micro820 Controller User Manual)
Allen‑Bradley 2080-LC20-20QBB (Micro820) Programmable Controller Overview
- Poziționarea produsului
2080-LC20-20QBB is an Allen‑Bradley Micro820 compact integrated PLC manufactured by Rockwell Automation. Designed for standalone OEM machinery and small complete automation systems. It replaces conventional control circuits built with massive intermediate relays. Equipped with integrated digital & analog I/O and multiple communication ports, Montabil pe șină DIN. Target market: compact, low-cost standalone automation solutions.
Catalog Summary
2080: Micro800 series identifier
LC20: Micro820 controller platform
20: 20 native I/O points
Q: 24V DC sourcing (PNP) ieșire digitală
BB: Onboard 4 intrări analogice +1 ieșire analogică, PTO pulse output, embedded Ethernet
- Native Hardware I/O Specifications
- Intrări digitale:12-point DC24V (configurable sinking/sourcing)
Signal acquisition: Photoelectric sensors, comutatoare de proximitate, limit switches, start/stop pushbuttons, oprire de urgență, door interlock switches
- Ieșiri digitale:7-point DC24V PNP sourcing output
Drive small solenoid valves, indicator lamps, relee intermediare (de ex. MY2N-GS), bobine de contactor
- Integrated Analog Channels (Avantajul de bază)
4 intrări analogice: 0~10V, 0~20mA, thermistor temperature acquisition supported
1 ieșire analogică: 0~10V / 0~20mA, used for inverter speed regulation and modulating valve control
- Motion Control Functions
Încorporat 1 channel PTO/PWM pulse output, capable of driving stepper motor controllers for basic point positioning
- Capacitate de expansiune: 2 plug-in slots for high-speed counters, serial ports and additional I/O modules
- Funcții de bază
3.1 Discrete Logic Control (Funcția de bază)
Based on signals from sensors and operation buttons, execute programmed sequence, interblocare, mutual lock and start-stop logic:
Sequential start/stop of conveyors, automatic cylinder cycling, automatic machine workflows, safety loop judgment and fault alarm output.
Can be paired with MY2N-GS intermediate relays to drive high-power loads indirectly.
3.2 Analog Process Control (Advantage of Onboard Analog Channels)
Collect temperature, presiune, liquid level and flow signals from transducers
Built-in PID function: Constant temperature control, alimentare cu apă la presiune constantă, air volume regulation; Analog output to adjust inverter speed and proportional valves.
3.3 High-speed Signal Processing
High-speed counters read encoder pulses (viteză & position measurement); PTO pulses implement basic stepper positioning.
3.4 Communication Networking
- EtherNet/IP Ethernet Port
Connect HMI touchscreens, SCADA host computers and other Rockwell PLCs for remote monitoring, parameter access and program upload/download.
- RS232/RS485 (Non-isolated Serial Port)
Modbus RTU Master/Slave interface to connect inverters, instruments and third-party sensors.
- USB Programming Port: Direct connection to PC for program download and online debugging.
3.5 Stocarea datelor, Recipe & Log Management
Embedded RTC real-time clock: Timed tasks, timestamp for fault logging
MicroSD card slot: Store production recipes, runtime logs, înregistrări de erori; support program backup & one-click restore.
3.6 HMI Expansion
Supports external remote text display 2080‑REMLCD, enabling parameter modification and alarm display without additional touchscreen panels.
- Typical Industries & Echipamente
- Mașini de ambalare: Small sealers, etichetatoare, mașini de umplere, miniature sorting conveyor systems
- HVAC & Tratarea apei: Small pump stations, air handling units, constant temperature water tanks, chemical dosing systems
- Utilaje alimentare & Central Kitchen Equipment: Washing lines, material conveyors, temperature-controlled ovens, smoke exhaust control systems
- Custom Automation: Assembly tooling, test benches, small transfer equipment
- Auxiliary control for machine tools, material conveying lines
- Laboratory equipment, small constant-temperature aging equipment
- Software de programare
Software de programare: Connected Components Workbench (CCW)
Supported languages: Diagrama de scară (LD), Diagrama blocului funcțional (FBD), Text structurat (SF), compliant with IEC61131‑3
- Application Boundaries
✅ Suitable for: Standalone machines with limited I/O, analog acquisition/PID demand, Ethernet networking requirement, cost-sensitive OEM equipment
❌ Not suitable for: Multi-axis servo synchronization, large-scale distributed production lines, massive remote I/O, high safety-level safety circuits (install dedicated safety relays such as G9SX for safety functions)
Supplement Remarks
- Terminology strictly follows Rockwell Automation official datasheet standards, suitable for export tender documents, equipment manuals and overseas product catalogs;
- Consistent industrial automation vocabulary matching international engineering conventions;
- If you need Russian translation or condensed datasheet version, I can process further.