Hakko MONITOUCH V810iCN-080 HMI

The V8 series HMI is discontinued. It is widely used on legacy equipment (de ex., Toshiba injection molding machines), featuring a 10.4-inch analog resistive industrial touchscreen. Model Code Definition V810: V8 series, 10.4-inch model i: Built-in LAN Ethernet port (V810iCN has no optional expansion unit port) C: Standard VGA (640×480) economy version N: Atingere analogică rezistivă ...

  • Detalii despre produs

The V8 series HMI este întreruptă. It is widely used on legacy equipment (de ex., Toshiba injection molding machines), featuring a 10.4-inch analog resistive industrial touchscreen.

Definiția codului modelului

V810: V8 series, 10.4-inch model

i: Built-in LAN Ethernet port (V810iCN has no optional expansion unit port)

C: Standard VGA (640×480) economy version

N: Analog resistive touch panel

080: DC24V power supply variant (suffix D also stands for DC24V; AC models have no such suffix)

Specificații hardware de bază

Afişa: 10.4″ LCD color TFT, 640×480 VGA, 65,536 culorile

Touch type: Atingere analogică rezistivă

Iluminare de fundal: LED, rated service life approx. 70,000 ore

Memorie: 4.5MB FROM for screen storage; 128KB SRAM (for recipes & alarm logs)

Front panel protection: IP65 (with original waterproof gasket), rear side IP20

Dimensiuni de gabarit: 303.8 × 231.0 × 69.0 mm

Panel cutout size: 289.0 × 216.2 mm (+0.5/-0 toleranţă)

Rear Interface List

  1. LAN RJ45: 10/100Ethernet Mbps
  2. MJ1, MJ2 (8-pin modular): RS232/485
  3. D-Sub9 (CN1): RS232C / RS422/485
  4. USB-A (Gazdă), USB-B (Programming slave port)
  5. CF card slot (legacy CF card, not SD card)
  6. 24VDC power terminal block

Nota: V810iCN does NOT support GU video/RGB optional modules

Software & Comunicare

Software de programare: V-SFT-5 / V-SFT-6 (V-SFT6 supports V8, V9 and V10 series simultaneously)

8-way multi-protocol communication: Conectați-vă la 8 PLCs of different brands simultaneously (Mitsubishi, Siemens, Omron, Delta, regulatoare de temperatura, invertoare, etc.)

Supported functions: Alarme, trend graphs, recipe management, macro scripts, PLC ladder transfer, USB printing, CF card backup for screens & busteni

Opțiuni de înlocuire (Discontinued Model Upgrade)

  1. Official Series Upgrade: V1010iC (10.4-inch, identical cutout; project conversion via V-SFT automatic tool) – Top priority for direct replacement
  2. Domestic HMI Replacement: 10.4-inch local HMIs. Requires redeveloping project screens and reconfiguring communication protocols.

Important reminder: V8→V10 project conversion is irreversible. Always back up the original project before conversion.

Defecte comune & Sfaturi de întreținere

Typical failures: Unresponsive touch, touch offset, black screen, backlight failure, communication loss, unreadable CF card

Piese de schimb: Panou tactil, Iluminare de fundal cu LED, power board, card CF, backup battery for SRAM

Notă de întreținere: Legacy CF cards are difficult to source. Use USB for program upload/download whenever possible.

Hakko MONITOUCH V8 Series (Hakko Electronics / Fuji Electric) Lista completă a modelelor

The entire V8 series is end-of-life (EOL).

Suffix Explanation

i: Built-in LAN Ethernet port; no i = no Ethernet port

S: High-performance model, supports GU RGB video optional modules

T: Mid-range model

C: Standard economy model (V810iCN belongs to this branch)

M: Simplified model exclusive to V806

CH: 7.5-inch handheld type

X: 15-inch XGA high-end model

N: Atingere analogică rezistivă; D / 080: Sursa de alimentare DC24V

5.7-inch | V806 Series (320×240 QVGA)

V806M / V806iM

V806C / V806iC

V806T / V806iT

Power variants: V806iCD, V806iTD, V806iMD (DC24V)

7.5-inch | Handheld Model V808CH

V808CH / V808iCH

8.4-inch | V808 Series (640×480 VGA)

V808C / V808iC

V808S / V808iS

Power variants: V808iCD, V808iSD (DC24V)

10.4-inch | V810 Series (640×480 VGA, your target model here)

V810C / V810iC (Varianta economica; V810iCN-080 falls here; iC version cannot install GU video modules)

V810T / V810iT (Gama medie, supports GU optional units)

V810S / V810iS (De înaltă performanță, supports GU video/RGB modules)

Suffix variants: N (resistive touch), D/080 (DC24V), de ex., V810iCN, V810iTN, V810iSN

12.1-inch | V812 Series (800×600 SVGA)

V812S / V812iS (De înaltă performanță, supports GU video modules)

15-inch | V815 Series (1024×768 XGA)

V815iX (V8 series flagship; Ethernet + intrare video)

Function Comparison Table

Model BranchBuilt-in LAN (i)GU Video Module SupportPoziționare
V8xxC (V810iC/V808iC)Optional i❌Economie (standard for injection molding machines)
V8xxT (V810iT)Optional i✅Mid-range general purpose
V8xxS (V810iS/V812iS/V808iS)Optional i✅De înaltă performanță
V815iX✅✅15″ XGA top model
V806MOptional i❌5.7-inch entry-level
V808CHOptional i❌7.5-inch handheld

Optional Units (For V8i models with expansion port, excluding V810iC)

GU-00/01/02/03/10/11: RGB video input units; DUN-10: V806 dedicated expansion unit

Software & Înlocuire

Software de programare: V-SFT5 / V-SFT6

Official upgrade series: V10 series (V1010iC is the preferred drop-in replacement for V810iCN, same cutout size; one-click project conversion in V-SFT6)

Replacement Model List for V810iCN-080 (Hakko MONITOUCH)

Key specs of original unit: 10.4-inch, DC24V, Ethernet încorporat, economy grade, no video expansion port, cutout size: 289.0 × 216.2 mm

  1. Original Brand Upgrade (Prima alegere: Project Migration, No Cutout Modification)

(1) Seria V10 (Current Fuji/Hakko Mainstream, Official Recommended Replacement)

V1010iC-D (Top Pick)

✅ Identical panel cutout; no cabinet modification required. V-SFT6 automatically converts V8 project files.

✅ Equipped with LAN, serial ports and USB; SD card replaces legacy CF card.

⚠️ Resolution upgraded from 640×480 to 800×600; screens auto-scale with minor control adjustments needed. Converted projects cannot be opened again on V8 software.

V1010iS-D (High-end Alternative)

Supports video input with higher performance, same cutout dimensions for future video expansion needs.

(2) Seria V9 (Transitional Discontinued Model, Only Stock Available)

V9100iC (Official designated replacement for V810iC series)

Project migration via V-SFT6. Stock availability is limited; not the first choice.

(3) V8 Series Spare Replacement (Only for Used Secondhand Parts, Not for New Purchases)

V810iTN-080 / V810iSN-080

Același contur & cutout size; extra video expansion port. The original V810iCN cannot fit GU modules, while iTN/iSN support video add-ons. Project files can be downloaded directly without modification.

  1. Domestic HMI Replacement (Project Reconfiguration Required)

Selection criteria: 289×216mm cutout, 10.4-inch, DC24V, Ethernet + RS485/232 ports

Weintek: MT8106iP / MT8106iE (Check cutout carefully; adapter plate may be needed)

Kunlun Tongtai: TPC1061Ti (Verify cutout dimensions)

Kinco / Xinje: Most 10.4-inch high-end models require custom adapter panels or cabinet re-cutting.

Dezavantaj: V-SFT project files cannot be imported directly; full re-configuration and communication debugging required.

Selection Comparison Table

Model de înlocuireNo Cutout ModificationDirect Project MigrationVideo Module SupportStarea aprovizionării
V1010iC-D✅✅ (V-SFT6 conversion)❌Commercially available
V1010iS-D✅✅✅Commercially available
V9100iC✅✅❌Întrerupt, only stock/used
V810iTN/080✅✅✅Întrerupt, secondhand only
Domestic 10.4″ HMIAdapter plate may be needed❌, full re-programmingDepends on modelAbundant stock

Critical Migration Notes

  1. Back up the original V8 project file before conversion; V8→V10 conversion is irreversible.
  2. Recipes and alarm logs stored on the original CF card must be exported and imported separately after migration.
  3. Protocoale de comunicare (Mitsubishi MC, Siemens S7, Omron Hostlink, etc.) are fully compatible with V10; protocol parameters remain almost unchanged.
  4. Terminal pin assignments, 24V power and serial pinouts differ. Always cross-check the V10 manual before wiring.