The S-T35 belongs to Mitsubishi MS-T Series, the upgraded successor model of S-N35, which is fully interchangeable with S-N35. It is an AC coil driven contactor widely used for three-phase motor start-stop and power circuit control in control cabinets.
✅ Core Specifications
Dimensiunea cadrului: 35 cadru, 3-contactele principale ale polului
AC-3 rating at 380/400V: 18.5kW, rated operating current 35A
Tensiunea maximă a circuitului principal: AC690V
Standard built-in auxiliary contacts: 2NU + 2NC (2a2b)
Dimensiuni de gabarit: 75(W) × 89(H) × 91(D) mm, weight 0.55kg
Montare: DIN rail mounting or screw fixing; mounting hole positions fully compatible with S-N35
Clasa de protectie: IP20
Rezistenta mecanica: 10 milioane de operațiuni; Rezistenta electrica (AC-3): aproximativ. 1 milioane de operațiuni
Coil voltage options (AC standard): AC24V, AC110V, AC220V, AC380V, AC400V, AC500V, 50/60Hz universal
✅ Model Naming Rule
`S-T35 + Coil Voltage`
Exemplu: S-T35 AC220V, S-T35 AC380V
Nota: S-T series is AC coil by default. DC coil version is SD-T series; do not mix them up.
✅ Comparison with S-N35
Curentul nominal al contactului principal, power rating and auxiliary contact configuration are identical
Mounting dimensions and drilling holes are interchangeable for direct replacement
Optimized coil pull-in performance, wider voltage tolerance range and lower power consumption; officially recommended replacement for S-N35
✅ Matching Accessories
Module de contact auxiliare: UA, UN series (for contact expansion)
Surge suppressor: SZ series (varistor / RC absorber to suppress coil back EMF)
Releu termic de suprasarcina: TH-T35 (protectie la suprasarcina motorului, potrivit pentru 35 cadru)
Mechanical interlock unit: used for forward/reverse (inversarea) circuit
✅ Typical Application Scenarios
Mașini de turnat prin injecție, fani & pompe de apa, linii de producție, compresoare de aer, HVAC control cabinets, machine tool power circuits, direct start-stop control of three-phase asynchronous motors.
✅ Troubleshooting Guide
- Coil energized but no pull-in: Verificați tensiunea bobinei, check loose wiring, test burnt coil
- Humming noise after pull-in: Undervoltage supply, dust/rust on iron core mating surfaces
- Severe main contact arcing & ardere: Overload beyond AC-3 rating, pierdere de fază, frequent switching, damaged arc shield
- Unstable auxiliary contact signals: Oxidized contact surface, insufficient terminal tightening torque
✅ Cross-Brand Equivalent Models
Schneider LC1D38, Siemens 3RT2035, OMRON CJX2-32
- Terminal Definition of S-T35 (Standard 2a2b)
Circuitul principal (Incoming top, outgoing bottom)
L1, L2, L3 (Partea de alimentare); T1, T2, T3 (Partea de încărcare, connected to TH-T35 thermal relay input terminals)
Terminale bobine
A1, A2: bobina AC. Two A2 terminals are internally shorted for easy jumper wiring.
Built-in Auxiliary Contacts (2NU+2NC)
✅ Normally Open (NU): 13-14, 43-44
✅ Normally Closed (NC): 21-22, 31-32
Screw size: Main circuit M4; Bobina & auxiliary contacts M3.5
- Basic Self-Locking Wiring Diagram (S-T35 + TH-T35 Thermal Relay, Motor Start-Stop)
Circuitul principal
3-phase power → Circuit breaker → S-T35 L1/L2/L3 → S-T35 T1/T2/T3 → TH-T35 thermal relay input → Thermal relay output → Motor M
Circuit de control (AC220V example)
- L → Stop button (NC) → Butonul Start (NU) → S-T35 A1
- N → S-T35 A2
- Self-locking: Paralel 13-14 (NU) across the start button
- Protectie la suprasarcina: Wire TH-T35 95-96 (NC) in series into the control circuit; the coil will cut off when overload trips
Full Model List of MS-T Series
1) Non-Reversing Standard Models (S-T, your S-T35 is included)
| Model | AC-3 Current (380V) | Puterea motorului (380V) | Contacte auxiliare standard |
| S-T10 | 11O | 5.5kW | 1a1b |
| S-T12 | 13O | 7.5kW | 1a1b |
| S-T20 | 18O | 7.5kW | 1a1b |
| S-T21 | 21O | 11kW | 2a2b |
| S-T25 | 25O | 11kW | 2a2b |
| S-T32 | 32O | 15kW | 2a2b |
| S-T35 | 35O | 18.5kW | 2a2b |
| S-T50 | 50O | 22kW | 2a2b |
| S-T65 | 65O | 30kW | 2a2b |
| S-T80 | 80O | 37kW | 2a2b |
| S-T100 | 100O | 45kW | 2a2b |
Coil suffix options: AC24V / AC110V / AC220V / AC380V; de ex. S-T35 AC220V
2) Mers înapoi (Înainte/înapoi) Integrated Models (S-2×T with built-in interlock)
S-2×T10, S-2×T12, S-2×T20, S-2×T21, S-2×T25, S-2×T32, S-2×T35, S-2×T50, S-2×T65, S-2×T80, S-2×T100
3) Special Derivative Models (Same frame, structură diferită)
- DC Coil Version (SD-T, not interchangeable with S-T)
SD-T10, SD-T12, SD-T20, SD-T21, SD-T25, SD-T32, SD-T35, SD-T50, SD-T65, SD-T80, SD-T100
- Mechanical Latching Type (SL-T): Pull-in on energization, keep closed after power cut; only released when control circuit is disconnected
SL-T21, SL-T35, SL-T50, SL-T65, SL-T80, SL-T100
- Off-Delay Release Type (S-T□DL)
S-T12DL, S-T21DL, S-T35DL
- Matching Thermal Overload Relays (TH-T Series, frame-matched one-to-one)
TH-T18 (for T10/T12/T20)
TH-T25 (for T21/T25/T32)
TH-T35 (for S-T35)
TH-T50 (for T50)
TH-T65 (for T65/T80)
TH-T100 (for T100)
III. Magnetic Starters (Integrated contactor + releu termic)
Nerevers: MSO-T10, MSO-T12, MSO-T20, MSO-T21, MSO-T25, MSO-T32, MSO-T35, MSO-T50, MSO-T65, MSO-T80, MSO-T100
Mers înapoi: MSO-2×T10 …… MSO-2×T100
- Regula de denumire a modelului (S-T□)
S = Contactor
T = MS-T Series (replaces old S-N series)
Numeral = Frame current rating (10/12/20/21/25/32/35/50/65/80/100)
Sufix: Tensiunea bobinei (AC220V/AC380V); DL = Off-delay release; SL = Mechanical latch; SD = DC coil
- Cross-Replacement Table with Old S-N Series (Înlocuire directă)
S-T10 ↔ S-N10
S-T12 ↔ S-N12
S-T20 ↔ S-N20
S-T21 ↔ S-N21
S-T25 ↔ S-N25
S-T32 ↔ S-N32
S-T35 ↔ S-N35 (modelul dvs)
S-T50 ↔ S-N50
S-T65 ↔ S-N65
S-T80 ↔ S-N80
S-T100 ↔ S-N100