Defalcarea codului de model
E5EC QR 2 A S M 820
- E5EC: Serie, DIN panel mount digital PID temperature controller, dimension 48 mm(H) × 96 mm(W)
- QR: Dual control outputs
Q: OUT1 = Voltage pulse output (DC12V, for SSR drive)
R: OUT2 = SPST relay contact output (1o)
✅ Supports Heating + Cooling dual control
- 2: 2 auxiliary alarm outputs
- O: Power supply AC 100~240 V (50/60 Hz)
- S: Screw terminal block
- M: Universal multi-input
Supports K/J/T/S/R/B/N thermocouples, Pt100/Pt1000 RTD, 4~20 mA / 0~10 V analog signal
- 820: Function option code
Built-in RS485 Modbus communication
No heater burnout detection (intrare CT), no external event input
Distinction:
800 = No communication; 820 = With RS485; 808/828 = With CT heater current detection
- Specificații electrice cheie
| Articol | Caietul de sarcini |
| Dimensiunea de ansamblu | 48(H) × 96(W) × 60(D) mm, panel embedded mounting |
| Alimentare electrică | AC100~240 V, consum de energie aprox. 6.6 VA |
| Control Output 1(Q) | DC12V±20%, max. 21 mA PNP, SSR driving output |
| Control Output 2(R) | SPST relay 1a, AC250 V 5 O (sarcină rezistivă) |
| Ieșiri auxiliare | 2 ieșiri releu (for alarm, high/low limit, deviation alarm) |
| Sampling Cycle | 50 Domnișoară, high-speed PID calculation |
| Moduri de control | Standard PID, Auto-tuning (AT), ON/OFF control, Încălzire & Cooling control |
| Comunicare | Modbus RTU over RS485 (Standard for suffix -820) |
| Input Accuracy | RTD: ±0,2% FS; Termocuplu: ±0,3% FS |
| Mediul de operare | 0~50°C, fara condens, non-corrosive atmosphere |
- Simplified Terminal Definition
1, 2: AC Power Input
3, 4: OUT1 SSR voltage drive output
5, 6: OUT2 Relay control output
7, 8 / 9, 10: Two groups of auxiliary alarm outputs
Sensor terminals: Universal connection for thermocouple / Pt100 RTD
- Scenarii tipice de aplicare
Regulatoare de temperatură a matriței (TCU), Hot Air Ovens, Industrial Ovens, extruder heating & cooling control
Applications requiring SSR for heating + relay for cooling fan / cooling water valve
Automated production lines where PLC reads temperature and writes setpoint via RS485
- Cross-Series Alternative Models
E5EC-QR2ASM-800: Without RS485 communication (hardware identical otherwise)
E5EC-RR2ASM-820: Dual relay outputs, not suitable for high-frequency SSR control
E5EC-QX2ASM-820: Second output is 4~20 mA linear analog output
- Selecţie & Precauții de funcționare
- QR configuration is ideal: SSR for heating, relay for cooling loads;
- Relay output is NOT suitable for frequent switching (contact burnout risk); high-frequency loads must adopt Q voltage pulse output;
- Do not reverse A/B polarity of RS485 wiring; terminate resistor can be installed on demand;
- When enabling heating/cooling function, activate 2-PID heating-cooling control in parameters.
Practical Application Cases for OMRON E5EC-QR2ASM-820 Temperature Controller
Recap of core hardware strengths for this model:
✅ OUT1: DC12V voltage pulse output (drives SSR, suitable for high-frequency heating)
✅ OUT2: Relay contact output (drives fan / cooling water valve for cooling control)
✅ 2 independent alarm relay outputs
✅ Built-in RS485 Modbus-RTU (sufix -820)
✅ Universal input: Pt100 RTD, K/J/T thermocouple, 4~20 mA analog signal
👉 Best fit: Încălzire & Cooling 2-PID control + PLC network communication
Caz 1: Injection Mold Temperature Controller (Most Common Industry Solution)
Working Requirements
Stable mold temperature 40~120°C; cooling water valve activates above set temperature, electric heater turns on below set temperature; PLC remotely reads process temperature & setpoint; overtemperature alarm.
Hardware Layout
Senzor: Immersion Pt100 RTD
OUT1(Q) → SSR Solid State Relay → Electric heating tube
OUT2(R) → Intermediate Relay → Cooling water solenoid valve (cooling circuit)
ALM1: Absolute high overtemperature alarm; ALM2: Sensor breakage alarm
RS485 connected to Siemens S7-1200 / Mitsubishi FX5U PLC
Critical Controller Parameter Settings
- Modul de control: HEAT/COOL 2-PID
- Action type: Heating Reverse Action, Cooling Direct Action
- Enable AT auto-tuning to auto-calculate heating & cooling gain
- Comunicare: Modbus RTU, 9600, 8, N, 1
Project Benefits
Contactless SSR supports frequent cycling and extends heater service life; relay dedicated to cooling water valve; centralized collection of temperature data for multiple TCUs via PLC, production curve monitoring on HMI/SCADA.
Caz 2: Constant-Temperature Circulating Hot Air Oven / Food Baking Oven
Working Requirements
Temperature range 30~220°C; electric heating for temperature rise, exhaust fan activates for overheat ventilation; local panel operation + remote setpoint via HMI; audible & visual alarm when temperature exceeds limit.
Hardware Layout
Senzor: Type K Thermocouple
OUT1(Q) → SSR → Heating elements
OUT2(R) → Relay → Heat exhaust fan
Dual alarms: High absolute limit alarm, deviation alarm
RS485 directly connected to Weinview / Kunlun Tongtai HMI (PLC not mandatory)
Operation Tips
Ovens feature large thermal inertia; appropriately increase derivative time parameter. Set cooling dead band to prevent frequent toggle between heater and exhaust fan.
Caz 3: Auxiliary Zone Temperature Control for Plastic Extruder Barrel
Working Requirements
Thermal holding of extruder barrel section; cooling water jacket enabled when temperature rises excessively; unified communication management via machine main PLC.
Hardware Layout
Type K thermocouple mounted on outer barrel surface
OUT1: SSR control for heating bands
OUT2: Cooling water solenoid valve
RS485 integrated into machine Modbus bus; PLC reads zone process temperatures
Selection Advantage vs RR model
E5EC-QR2ASM-820 outperforms RR type: Contactless SSR on heating channel supports 24/7 continuous production and avoids relay contact ablation.
Caz 4: Small High-Low Temperature Test Chamber / Thermostatic Water Bath
Working Requirements
Precise temperature control ±0.5°C; heating compensation at low temperature, refrigeration activated at high temperature; support simple programmable temperature ramp/soak profile.
Layout
Immersion Pt100 RTD probe
OUT1 = Heating SSR; OUT2 = Refrigeration compressor / chilled water circulation pump
Built-in 2-PID heating-cooling balance suppresses minor temperature fluctuations.
Nota: Frequent compressor start-stop should be avoided; add start-stop delay logic in PLC program.
Caz 5: Lithium Battery Formation & Aging Thermostatic Cabinet (Noua industrie a energiei)
Working Requirements
Constant aging temperature 45°C; heater turns on when temperature drops, cooling fan activates for overheat; multiple controllers networked, MES system collects temperature data for traceability.
Architecture
Daisy-chain RS485 wiring for multiple E5EC units
PLC acts as Modbus master to poll PV(process value), SV(valoarea stabilită) and alarm status of each controller.
Two alarm outputs wired into safety circuit; overtemperature triggers overall equipment shutdown protection.
Caz 6: Small Rubber Curing Mold Heating Device
Working Requirements
Constant curing temperature 150~170°C; forced water cooling triggered on overtemperature; temperature adjustable locally, recipe parameters downloadable remotely.
Typical Fault Prevention
Cooling channel uses relay output, not suitable for ultra-frequent switching. PID buffering mitigates temperature fluctuation to prevent rapid cycling of cooling water valve.
Universal Wiring Logic (Applicable to all above cases)
- Alimentare electrică: Terminal 1, 2 → AC100~240 V
- OUT1 (3,4): SSR drive → Heating load
- OUT2 (5,6): Relay output → Cooling valve / ventilator de racire
- 11(O), 12(B): RS485 communication wires
- Sensor terminals: Wiring for Pt100 RTD / Termocuplu
Potrivit & Unsuitable Application Summary
✅ Recommended to select E5EC-QR2ASM-820
- Systems requiring Heating + Cooling bidirectional control
- High-frequency switching heating loads driven by SSR
- RS485 Modbus communication required with PLC/HMI
- Demand for two independent alarm outputs
❌ Not recommended for this model
- Only heating function required, no cooling (choose E5EC-QX2ASM-800 for cost saving)
- Continuous 4~20 mA analog output required (select QX series)
- Heater burnout detection via CT current transformer required (choose suffix -828 modele)
Contactor,întrerupător de circuit,invertor solar,contor electric,baterii solare




















NH42-63-318x560.png)