PILZ PNOZ m B0 Modular Safety Controller

PNOZ m B0 Base Unit, Comanda nr. 772100 Familie de produse: PNOZmulti 2 modular safety controller (PNOZ m2), configurable multi-function safety relay / compact safety PLC Model Code Definition PNOZ: PILZ safety relay series identifier m: Multi, modular configurable system B0: Unitate de bază 0, entry-level host without onboard fieldbus 772100: Unique material order number Core Technical ...

  • Detalii despre produs

PNOZ m B0 Base Unit, Comanda nr. 772100

Familie de produse: PNOZmulti 2 modulare safety controller (PNOZ m2), configurable multi-function safety relay / compact safety PLC

  1. Definiția codului modelului

PNOZ: CIUPERCĂ safety relay series identifier

m: Multi, modular configurable system

B0: Unitate de bază 0, entry-level host without onboard fieldbus

772100: Unique material order number

  1. Specificații tehnice de bază
  2. Alimentare electrică: 24 În DC
  3. Onboard Inputs: 8 safe digital inputs
  4. Onboard Outputs:

4 safe semiconductor outputs (OSSD)

  1. Comunicare: No integrated fieldbus interface (only B1/B2 models come with Profinet/EtherCAT onboard)
  2. Programare: Configured via PNOZmulti Configurator, program downloaded over USB port
  3. Safety Performance: PL e / SIL 3 (per EN ISO 13849 & IEC 61508)
  4. Temperatura de operare: -10℃ ~ +55℃
  5. Montare: Montare pe șină DIN
  6. Evaluare incintă: IP20 (numai pentru instalarea dulapului)
  7. Program Storage: SD card; program can be copied to another identical unit directly via card swapping
  8. Funcții & Aplicații tipice

Monitoring emergency stop pushbuttons, safety gate switches, safety light curtains, covorașe de siguranță, two-hand control stations

Safety logic: AND/OR operations, întârziere de timp, interblocare, safety counter, selectarea modului (auto/manual)

Target Equipment: Masini-unelte, utilaje de ambalare, linii de producție automatizate, sisteme de transport, robot peripheral safety protection

Key Feature: Modular architecture; I/O expansion modules can be added later.

Nota: PNOZ m B0 has no built-in bus interface and only supports local I/O. For fieldbus communication, select PNOZ m B1 (772100, Profinet) or PNOZ m B2 (772102, EtherCAT).

  1. Componente de potrivire

Module de expansiune (PNOZmulti 2 serie, mounted on the right side of 772100)

Digital input expansion: 772110

Relay output expansion: 772120

Semiconductor output expansion: 772121

Software

PNOZmulti Configurator (free download from PILZ official website; supports PNOZmulti Classic and PNOZmulti 2)

Program Migration

Programs can be copied directly via SD card; identic 772100 units run the program immediately after card insertion. Migration to B1/B2 bus versions requires hardware reconfiguration inside the software.

  1. On-Site Troubleshooting Guide
  2. No POWER LED: Verifica 24 V DC polarity, sigurante, terminal wiring and power supply ripple
  3. Constant ERR LED: Program configuration error, corrupted SD card or hardware fault; read diagnostic data via software
  4. No response from safety inputs: Check dual-channel wiring continuity, scurtcircuite, contact polarity and input filter parameters
  5. OSSD semiconductor outputs fail to energize: Safety logic conditions not met, output overload or short circuit; verify load status
  6. Cross-Model Alternatives & Competitor Products

Upgrade în serie

PNOZ m B1 (772101): Profinet interface

PNOZ m B2 (772102): EtherCAT FSoE interface

Echivalente între mărci

Schneider Electric XPSM series

Siemens F30 safety relay modules

IFM safety controllers

Domestic Replacements

Configurable safety controllers certified up to PL e / SIL 3.

Prescripţie: Different software, certification and terminal definitions; projects cannot be migrated directly and require full reconfiguration.

PNOZmulti 2 (PNOZ m2) Lista completă a modelelor (Comanda nr. 7721xx)

Base Units (Left: module de magistrală; Right: Module de extindere I/O)

ModelComanda nr.Descrierea cheiiMax. Module de expansiune
PNOZ m B0772100Entry model without onboard bus; 8DIN + 4OSSD; USB + SD card; this unitPână la 6 safety I/O modules on the right
PNOZ m B0.1772104Compact successor to PNOZmulti Mini; numai 1 expansion module allowedMax. 1 I/O module
PNOZ m B1772101Dual Profinet + Modbus TCP ports; large project capacity12 safety modules + 6 standard modules
PNOZ m B1 Burner772103B1 version dedicated for burner control with certified burner function blocksSame as B1
PNOZ m B2772102Native EtherCAT FSoE onboardSame as B1
PNOZ m C0772105Standalone non-expandable unit; 8DIN + 4OSSD; nicio capacitate de expansiune0 module de expansiune

Right-Side Safe I/O Expansion Modules (PNOZ m EF, PL e / SIL3)

Digital I/O Modules

ModelComanda nr.Configurare I/O
PNOZ m EF 16DI77214016 safe digital inputs
PNOZ m EF 8DI4DO7721428DIN + 4 OSSD semiconductor safety outputs
PNOZ m EF 8DI2DOT7721448DIN + 2 transistor outputs with test pulses (for press machines)
PNOZ m EF 4DI4DOR7721434DIN + 4 relay safety outputs (NU contacte)
PNOZ m EF 4DI4DORD7721454DIN + 4 ieșiri releu (NU + contacte NC)
PNOZ m EF 2DOR7721462 independent relay safety outputs

Safe Analog Input Module

|PNOZ m EF 4AI|772160|4-channel safe analog input (0–10 V / 4-20 mA)|

Motion Monitoring Modules (Safe axis control)

ModelComanda nr.Axis Count
PNOZ m EF 1MM7721701-viteza axei / monitorizarea poziției
PNOZ m EF 1MM2DO7721721 axă + 2 OSSD safety outputs
PNOZ m EF 2MM772171Dual-axis synchronous & speed monitoring

Right-Side Standard Non-Safe I/O Modules (PNOZ m ES, only supported by B1/B2)

ModelComanda nr.Configurare I/O
PNOZ m ES 16DI77218216 standard digital inputs
PNOZ m ES 14DO77218114 standard semiconductor outputs

Left-Side Communication & Link Modules

Fieldbus Modules

ModelComanda nr.Bus Type
PNOZ m ES Profinet772138Profinet IO (your previously referenced part number)
PNOZ m ES EtherCAT772132EtherCAT
PNOZ m ES ETH772130Standard Ethernet TCP/IP
PNOZ m ES Profibus772131Profibus DP
PNOZ m ES CANopen772133CANopen
PNOZ m ES CC-Link772134CC-Link
PNOZ m ES Powerlink772135Ethernet Powerlink
PNOZ m ES EtherNet/IP772136EtherNet/IP

Safety Interlink Modules (Multi-controller networking)

|PNOZ m EF Multi Link|772120|Interlink multiple PNOZ m2 controllers (cupru / fibre optic)|

|PNOZ m EF PDP Link|772121|Connect distributed PDP67 remote I/O|

|PNOZ m EF SafetyNET|772122|SafetyNET p safety Ethernet networking (max. 16 unitati)|

|PNOZ m EF FSoE|772123|EtherCAT FSoE safety communication extension|

Preconfigured Complete Packages

PNOZ m2p: 772100 + 772144 (standard press machine configuration)

PNOZ m2p ETH: 772100 + 772130 + 772144 (press version with Ethernet)

Piese de schimb & Accesorii

  1. Program SD card (not included with base unit; comandat separat)
  2. Terminale de conectare: Spring-clamp terminal 783542; borna cu șurub 793542
  3. Inter-module jumpers: 779260

Expansion Rules (Critic)

  1. PNOZ m B0 (772100): Max. 6 EF safety modules on the right; ES standard I/O modules are NOT supported; numai 1 bus/link module on the left.
  2. PNOZ m B1/B2: Max. 12 EF safety modules + până la 6 ES standard I/O modules on the right.
  3. PNOZ m B0.1 (772104): Numai 1 I/O module allowed; no multi-module cascading.

Application Scenarios for PNOZ m B0 (772100)

  1. General Safety Monitoring (Most Common Use Case)

It monitors and executes safety logic for these protection devices:

  1. Dual-channel E-Stop pushbuttons
  2. Safety gate switches (PSEN series)
  3. Perdele luminoase de siguranță & laser scanners
  4. Safety mats and safety edges
  5. Two-hand control buttons (press machine dedicated logic)
  6. 3-position enabling switches (teach pendant)
  7. Mode selector switches (auto/manual/jog interlock)
  8. Reset buttons and muting functions

Supported logic: AND/OR, întârziere de timp, interblocare, edge detection.

The OSSD outputs cut off main contactors or servo enable signals, fully complying with EN ISO 13849 standardele de siguranță a mașinilor.

  1. Industry-Specific Deployments

(1) Mașini-unelte & Press Equipment

Echipamente: Mechanical presses, hydraulic presses, presa frana, shears

Monitored signals: Two-hand stations, porti de siguranta, perdele luminoase, slider position (cu 772170 motion module)

Funcții de siguranță: Single-stroke operation, anti-repeat stroke, interblocare, delayed safe stop; pre-certified press function blocks available

Cerinţă: PL e Category 4; ideal for retrofits replacing multiple discrete safety relays.

(2) Mașini de ambalare

Machines: Vertical form-fill-seal machines, mașini de ambalare orizontale, case erectors, palletizers

Monitored points: Guard doors, feed opening light curtains, Opri, material muting

Benefit: Consolidate multiple safety door controls into one controller, reduce cabinet wiring and simplify fault diagnosis.

(3) Assembly Workstations & Robot Cells

Aplicații: Standalone robot cells, conveyor stations, fixare & stații de testare

Protecţie: Fence safety gates, laser area scanners, teach pendant enable switches, multi-zone safety interlocking

Optional upgrade: Instala 772138 Profinet module on the left to transmit safety status and fault codes to the main PLC and HMI for remote diagnostics.

(4) Manipularea materialelor & Logistics Automation

Echipamente: Transportoare cu bandă, linii de role, transfer lifts, sisteme de sortare

Use case: Multiple E-stops along the line, access door interlocks, sectional safe stop; distinguish local shutdown from global emergency stop.

(5) Cauciuc & Materiale plastice / Injection Molding Machines

Injection moulders and extruders: Guard door interlocks, hopper protection, mould area light curtains, mould safety interlock and safety time delay.

(6) Thermal Processing / Furnace Systems (ÎN 298 Conform)

Small heating furnaces: Monitor air pressure, flame signals, safety valve interlocks and burner safety chains.

Nota: Multi-burner large furnace systems should select the B1 Burner variant.

  1. Two Standard Engineering Configurations

Mode 1: Standalone Base Unit (No Expansion Modules)

8 safe DI + 4 OSSD onboard I/O.

Best for small standalone machines: 1~2 safety gates + 1 perdea luminoasă + E-stop with simple logic, economisind spațiu în dulap.

Mode 2: With Right-Side EF Expansion Modules (Max. 6 Module)

Expandable for:

Extra digital inputs / ieșiri releu

Safe analog modules (temperatură & pressure safety monitoring)

Safe motion control modules (viteză, position and safe speed limitation)

Suitable for medium-sized machines with multiple guard points and axis safety monitoring.

  1. Modernizare & Machine Modernisation Projects

Perfect for legacy equipment upgrades:

Replace dozens of discrete safety relays with one controller, simplify wiring and reduce troubleshooting time.

Logic is software-configured; the built-in LCD directly pinpoints fault locations, cutting spare part varieties.

Program backup via SD card; replacement units run immediately after card insertion.

  1. Selection Boundaries (When NOT to choose 772100)
  2. Large production lines with high I/O count and demand for standard non-safety I/O → Choose PNOZ m B1 (772101)
  3. Native EtherCAT FSoE bus required → Choose PNOZ m B2 (772102)
  4. Minimal safety points with zero expansion needed → Compact PNOZ m C0 (772105)
  5. Multi-burner furnace systems → PNOZ m B1 Burner
  6. Bus Communication Solution: 772100 + 772138

Install the PNOZ m ES Profinet (772138) module on the left slot of PNOZ m B0:

Hardwired local safety cut-off remains fully independent. Safety status, fault codes and I/O states are uploaded to the main PLC via Profinet.

The PLC only performs monitoring; safety shutdown never relies on fieldbus communication, fully complying with functional safety regulations.