PNOZ m B0 Base Unit, Comanda nr. 772100
Familie de produse: PNOZmulti 2 modulare safety controller (PNOZ m2), configurable multi-function safety relay / compact safety PLC
- Definiția codului modelului
PNOZ: CIUPERCĂ safety relay series identifier
m: Multi, modular configurable system
B0: Unitate de bază 0, entry-level host without onboard fieldbus
772100: Unique material order number
- Specificații tehnice de bază
- Alimentare electrică: 24 În DC
- Onboard Inputs: 8 safe digital inputs
- Onboard Outputs:
4 safe semiconductor outputs (OSSD)
- Comunicare: No integrated fieldbus interface (only B1/B2 models come with Profinet/EtherCAT onboard)
- Programare: Configured via PNOZmulti Configurator, program downloaded over USB port
- Safety Performance: PL e / SIL 3 (per EN ISO 13849 & IEC 61508)
- Temperatura de operare: -10℃ ~ +55℃
- Montare: Montare pe șină DIN
- Evaluare incintă: IP20 (numai pentru instalarea dulapului)
- Program Storage: SD card; program can be copied to another identical unit directly via card swapping
- Funcții & Aplicații tipice
Monitoring emergency stop pushbuttons, safety gate switches, safety light curtains, covorașe de siguranță, two-hand control stations
Safety logic: AND/OR operations, întârziere de timp, interblocare, safety counter, selectarea modului (auto/manual)
Target Equipment: Masini-unelte, utilaje de ambalare, linii de producție automatizate, sisteme de transport, robot peripheral safety protection
Key Feature: Modular architecture; I/O expansion modules can be added later.
Nota: PNOZ m B0 has no built-in bus interface and only supports local I/O. For fieldbus communication, select PNOZ m B1 (772100, Profinet) or PNOZ m B2 (772102, EtherCAT).
- Componente de potrivire
Module de expansiune (PNOZmulti 2 serie, mounted on the right side of 772100)
Digital input expansion: 772110
Relay output expansion: 772120
Semiconductor output expansion: 772121
Software
PNOZmulti Configurator (free download from PILZ official website; supports PNOZmulti Classic and PNOZmulti 2)
Program Migration
Programs can be copied directly via SD card; identic 772100 units run the program immediately after card insertion. Migration to B1/B2 bus versions requires hardware reconfiguration inside the software.
- On-Site Troubleshooting Guide
- No POWER LED: Verifica 24 V DC polarity, sigurante, terminal wiring and power supply ripple
- Constant ERR LED: Program configuration error, corrupted SD card or hardware fault; read diagnostic data via software
- No response from safety inputs: Check dual-channel wiring continuity, scurtcircuite, contact polarity and input filter parameters
- OSSD semiconductor outputs fail to energize: Safety logic conditions not met, output overload or short circuit; verify load status
- Cross-Model Alternatives & Competitor Products
Upgrade în serie
PNOZ m B1 (772101): Profinet interface
PNOZ m B2 (772102): EtherCAT FSoE interface
Echivalente între mărci
Schneider Electric XPSM series
Siemens F30 safety relay modules
IFM safety controllers
Domestic Replacements
Configurable safety controllers certified up to PL e / SIL 3.
Prescripţie: Different software, certification and terminal definitions; projects cannot be migrated directly and require full reconfiguration.
PNOZmulti 2 (PNOZ m2) Lista completă a modelelor (Comanda nr. 7721xx)
Base Units (Left: module de magistrală; Right: Module de extindere I/O)
| Model | Comanda nr. | Descrierea cheii | Max. Module de expansiune |
| PNOZ m B0 | 772100 | Entry model without onboard bus; 8DIN + 4OSSD; USB + SD card; this unit | Până la 6 safety I/O modules on the right |
| PNOZ m B0.1 | 772104 | Compact successor to PNOZmulti Mini; numai 1 expansion module allowed | Max. 1 I/O module |
| PNOZ m B1 | 772101 | Dual Profinet + Modbus TCP ports; large project capacity | 12 safety modules + 6 standard modules |
| PNOZ m B1 Burner | 772103 | B1 version dedicated for burner control with certified burner function blocks | Same as B1 |
| PNOZ m B2 | 772102 | Native EtherCAT FSoE onboard | Same as B1 |
| PNOZ m C0 | 772105 | Standalone non-expandable unit; 8DIN + 4OSSD; nicio capacitate de expansiune | 0 module de expansiune |
Right-Side Safe I/O Expansion Modules (PNOZ m EF, PL e / SIL3)
Digital I/O Modules
| Model | Comanda nr. | Configurare I/O |
| PNOZ m EF 16DI | 772140 | 16 safe digital inputs |
| PNOZ m EF 8DI4DO | 772142 | 8DIN + 4 OSSD semiconductor safety outputs |
| PNOZ m EF 8DI2DOT | 772144 | 8DIN + 2 transistor outputs with test pulses (for press machines) |
| PNOZ m EF 4DI4DOR | 772143 | 4DIN + 4 relay safety outputs (NU contacte) |
| PNOZ m EF 4DI4DORD | 772145 | 4DIN + 4 ieșiri releu (NU + contacte NC) |
| PNOZ m EF 2DOR | 772146 | 2 independent relay safety outputs |
Safe Analog Input Module
|PNOZ m EF 4AI|772160|4-channel safe analog input (0–10 V / 4-20 mA)|
Motion Monitoring Modules (Safe axis control)
| Model | Comanda nr. | Axis Count |
| PNOZ m EF 1MM | 772170 | 1-viteza axei / monitorizarea poziției |
| PNOZ m EF 1MM2DO | 772172 | 1 axă + 2 OSSD safety outputs |
| PNOZ m EF 2MM | 772171 | Dual-axis synchronous & speed monitoring |
Right-Side Standard Non-Safe I/O Modules (PNOZ m ES, only supported by B1/B2)
| Model | Comanda nr. | Configurare I/O |
| PNOZ m ES 16DI | 772182 | 16 standard digital inputs |
| PNOZ m ES 14DO | 772181 | 14 standard semiconductor outputs |
Left-Side Communication & Link Modules
Fieldbus Modules
| Model | Comanda nr. | Bus Type |
| PNOZ m ES Profinet | 772138 | Profinet IO (your previously referenced part number) |
| PNOZ m ES EtherCAT | 772132 | EtherCAT |
| PNOZ m ES ETH | 772130 | Standard Ethernet TCP/IP |
| PNOZ m ES Profibus | 772131 | Profibus DP |
| PNOZ m ES CANopen | 772133 | CANopen |
| PNOZ m ES CC-Link | 772134 | CC-Link |
| PNOZ m ES Powerlink | 772135 | Ethernet Powerlink |
| PNOZ m ES EtherNet/IP | 772136 | EtherNet/IP |
Safety Interlink Modules (Multi-controller networking)
|PNOZ m EF Multi Link|772120|Interlink multiple PNOZ m2 controllers (cupru / fibre optic)|
|PNOZ m EF PDP Link|772121|Connect distributed PDP67 remote I/O|
|PNOZ m EF SafetyNET|772122|SafetyNET p safety Ethernet networking (max. 16 unitati)|
|PNOZ m EF FSoE|772123|EtherCAT FSoE safety communication extension|
Preconfigured Complete Packages
PNOZ m2p: 772100 + 772144 (standard press machine configuration)
PNOZ m2p ETH: 772100 + 772130 + 772144 (press version with Ethernet)
Piese de schimb & Accesorii
- Program SD card (not included with base unit; comandat separat)
- Terminale de conectare: Spring-clamp terminal 783542; borna cu șurub 793542
- Inter-module jumpers: 779260
Expansion Rules (Critic)
- PNOZ m B0 (772100): Max. 6 EF safety modules on the right; ES standard I/O modules are NOT supported; numai 1 bus/link module on the left.
- PNOZ m B1/B2: Max. 12 EF safety modules + până la 6 ES standard I/O modules on the right.
- PNOZ m B0.1 (772104): Numai 1 I/O module allowed; no multi-module cascading.
Application Scenarios for PNOZ m B0 (772100)
- General Safety Monitoring (Most Common Use Case)
It monitors and executes safety logic for these protection devices:
- Dual-channel E-Stop pushbuttons
- Safety gate switches (PSEN series)
- Perdele luminoase de siguranță & laser scanners
- Safety mats and safety edges
- Two-hand control buttons (press machine dedicated logic)
- 3-position enabling switches (teach pendant)
- Mode selector switches (auto/manual/jog interlock)
- Reset buttons and muting functions
Supported logic: AND/OR, întârziere de timp, interblocare, edge detection.
The OSSD outputs cut off main contactors or servo enable signals, fully complying with EN ISO 13849 standardele de siguranță a mașinilor.
- Industry-Specific Deployments
(1) Mașini-unelte & Press Equipment
Echipamente: Mechanical presses, hydraulic presses, presa frana, shears
Monitored signals: Two-hand stations, porti de siguranta, perdele luminoase, slider position (cu 772170 motion module)
Funcții de siguranță: Single-stroke operation, anti-repeat stroke, interblocare, delayed safe stop; pre-certified press function blocks available
Cerinţă: PL e Category 4; ideal for retrofits replacing multiple discrete safety relays.
(2) Mașini de ambalare
Machines: Vertical form-fill-seal machines, mașini de ambalare orizontale, case erectors, palletizers
Monitored points: Guard doors, feed opening light curtains, Opri, material muting
Benefit: Consolidate multiple safety door controls into one controller, reduce cabinet wiring and simplify fault diagnosis.
(3) Assembly Workstations & Robot Cells
Aplicații: Standalone robot cells, conveyor stations, fixare & stații de testare
Protecţie: Fence safety gates, laser area scanners, teach pendant enable switches, multi-zone safety interlocking
Optional upgrade: Instala 772138 Profinet module on the left to transmit safety status and fault codes to the main PLC and HMI for remote diagnostics.
(4) Manipularea materialelor & Logistics Automation
Echipamente: Transportoare cu bandă, linii de role, transfer lifts, sisteme de sortare
Use case: Multiple E-stops along the line, access door interlocks, sectional safe stop; distinguish local shutdown from global emergency stop.
(5) Cauciuc & Materiale plastice / Injection Molding Machines
Injection moulders and extruders: Guard door interlocks, hopper protection, mould area light curtains, mould safety interlock and safety time delay.
(6) Thermal Processing / Furnace Systems (ÎN 298 Conform)
Small heating furnaces: Monitor air pressure, flame signals, safety valve interlocks and burner safety chains.
Nota: Multi-burner large furnace systems should select the B1 Burner variant.
- Two Standard Engineering Configurations
Mode 1: Standalone Base Unit (No Expansion Modules)
8 safe DI + 4 OSSD onboard I/O.
Best for small standalone machines: 1~2 safety gates + 1 perdea luminoasă + E-stop with simple logic, economisind spațiu în dulap.
Mode 2: With Right-Side EF Expansion Modules (Max. 6 Module)
Expandable for:
Extra digital inputs / ieșiri releu
Safe analog modules (temperatură & pressure safety monitoring)
Safe motion control modules (viteză, position and safe speed limitation)
Suitable for medium-sized machines with multiple guard points and axis safety monitoring.
- Modernizare & Machine Modernisation Projects
Perfect for legacy equipment upgrades:
Replace dozens of discrete safety relays with one controller, simplify wiring and reduce troubleshooting time.
Logic is software-configured; the built-in LCD directly pinpoints fault locations, cutting spare part varieties.
Program backup via SD card; replacement units run immediately after card insertion.
- Selection Boundaries (When NOT to choose 772100)
- Large production lines with high I/O count and demand for standard non-safety I/O → Choose PNOZ m B1 (772101)
- Native EtherCAT FSoE bus required → Choose PNOZ m B2 (772102)
- Minimal safety points with zero expansion needed → Compact PNOZ m C0 (772105)
- Multi-burner furnace systems → PNOZ m B1 Burner
- Bus Communication Solution: 772100 + 772138
Install the PNOZ m ES Profinet (772138) module on the left slot of PNOZ m B0:
Hardwired local safety cut-off remains fully independent. Safety status, fault codes and I/O states are uploaded to the main PLC via Profinet.
The PLC only performs monitoring; safety shutdown never relies on fieldbus communication, fully complying with functional safety regulations.
Contactor,întrerupător de circuit,senzor,Codificator,PLC,Convertor




















NH42-63-318x560.png)