Pepperl+Fuchs UC2000-F43-2KIR2-V17 sensor

Articol nr.: 120329 | Stare produs: Învechit (Discontinued by Manufacturer) Model Code Breakdown `UC2000-F43-2KIR2-V17` UC2000: UC series ultrasonic sensor, maximum measuring distance 2000 mm F43: Flat rectangular housing (F-type enclosure) 2K: 2 relay contact outputs I: Analogue 4…20 mA current output R2: Built-in RS232 interface for parameter programming V17: Hardware version V17 Core Technical Specifications ...

  • Detalii despre produs

Articol nr.: 120329 | Stare produs: Învechit (Discontinued by Manufacturer)

  1. Defalcarea codului de model

`UC2000-F43-2KIR2-V17`

  1. UC2000: UC series senzor ultrasonic, maximum measuring distance 2000 mm
  2. F43: Flat rectangular housing (F-type enclosure)
  3. 2K: 2 relay contact outputs
  4. eu: Analogue 4…20 mA current output
  5. R2: Built-in RS232 interface for parameter programming
  6. V17: Hardware version V17
  7. Specificații tehnice de bază

Ranging Performance

ArticolCaietul de sarcini
Effective measuring range100 … 2000 mm
Blind zone (zona moarta)0 … 100 mm
Transducer frequencyAproximativ. 175 kHz
Standard reflector target100×100 mm flat plate
Measurement resolution0.5 mm
Non-linearity error<0.2% of full scale
Repeat accuracy≤0.1% of full scale
Programmable hysteresis0~15% of measuring range adjustable

Date electrice

Tensiune de alimentare:

Without analogue output: 10…30 VDC; With 4–20mA activated: 15…30 VDC

No-load power consumption: ≤0.7 W; Max. full-load power consumption: ≤2 W

Output Combination (Key Feature)

2 independent relay outputs (SPDT changeover contacts)

Evaluarea contactului: 60 VDC / 1 O (sarcină rezistivă, max. 24 W DC)

1 analogue 4 … 20 mA output, maximum load impedance ≤500 Ω

Comunicare: RS232, 9600bps, 8N1. Parameter configuration via UC-PROG1-USB and ULTRA2001 software

Timp de răspuns: Min. ≤50 ms; Factory default ≤150 ms

Mecanic & Specificații de mediu

Conexiune: M12×1 8-pin male connector

Clasa de protectie: IP65

Materialul carcasei: PBT thermoplastic

Temperatura de functionare: -25 ℃ ~ +70 ℃

Temperatura de depozitare: -40 ℃ ~ +85 ℃

Greutate: 290 g

Built-in temperature compensation

Indicație LED de stare

Green LED steady ON: Target within measuring window; Green LED flashing: Nu a fost detectată nicio țintă

Red LED ON: Fault condition (high acoustic interference, eroare de cablare, etc.)

  1. M12 8-Pin Pin Assignment
PinDefiniţie
1DC+ Power Positive
2Releu 1 Terminal comun
3DC- Power Negative
4Releu 2 Terminal comun
54~20mA Analogue Signal Output
6Releu 1 Deschis normal / În mod normal închis
7Releu 2 Deschis normal / În mod normal închis
8Shield (Housing Earth) + RS232 Communication

⚠️ Important Note: When using the 4–20mA output, supply voltage must not drop below 15 VDC; otherwise analogue output malfunction will occur.

  1. Câmpuri tipice de aplicare
  2. Warehouse & Logistică: Level height detection, pallet presence detection, anti-collision distance measurement
  3. Mașini de ambalare: Roll diameter measurement, material presence monitoring
  4. Tratarea apei: Non-contact level measurement for open tanks
  5. Automatizare generală: All-in-one solution for dual limit switching + continuous distance transmission

Avantaj: Single sensor delivers two limit switch signals + continuous distance feedback, economisind spațiu de instalare.

  1. Opțiuni de înlocuire (Critical Section)

No direct pin-to-pin upgraded model available with original F43 flat housing. Two selection options:

Opţiune 1: Functional Equivalent (Requires modified mounting bracket & electrical adaptation)

UC2000-L2-IUR2-V15

Domeniul de măsurare: 100…2000 mm

Ieșiri: 4–20mA analogue + 2 PNP switching outputs + RS232

Diferenţă: Ieșire tranzistor, no relay contacts; Cylindrical housing with different mounting dimensions

If passive relay contacts are mandatory on site, select third-party ultrasonic sensor paired with external relay.

Opţiune 2: Maintain Relay Output

Folosit doar / refurbished stock available for legacy series. Pentru proiecte noi:

UC2000-L2-IUR2-V15 + auxiliary miniature relay for contact conversion.

  1. Selecţie & Ghid de operare / Evitarea capcanelor
  2. Blind Zone Limitation: Reliable measurement impossible within 100 mm; Do not select for close-range applications.
  3. Acoustic Cone Interference: Activate sensor synchronisation function when multiple sensors are installed side-by-side to prevent mutual ultrasonic interference.
  4. Medium Limitation: Soft foam, fluffy fabrics produce weak echo and lead to unstable detection.
  5. Relay Service Life: Electrical service life limited to 3×10⁵ switching cycles. Not suitable for high-frequency switching applications. Transistor output models are recommended for frequent operation.
  6. Programming Requirement: Adjustment of switching points, measuring range and hysteresis requires UC-PROG1-USB programming cable. No external teach-in button available.
  7. Matricea de depanare
Simptom de eroareCauza de bazăRemedial Action
Analogue output locked at 4mA / 20mATarget out of measuring range / Undersupply voltageVerify supply ≥15 VDC; Confirm target is within 100~2000 mm range
Relay triggers falsely and frequentlyAcoustic reflection interference, insufficient hysteresis settingIncrease hysteresis parameter; Install separation baffles; Enable synchronisation mode
Red LED continuously illuminatedOndularea excesivă a sursei de alimentare / Internal sensor failureAdd power supply filter; Check shielding wiring of pin 8
Communication connection failureIncorrect RS232 wiring, mismatched baud rateConfirm 9600,8N1 setting; Use original UC-PROG1 adapter

Pepperl+Fuchs UC2000-F43-2KIR2-V17 Practical Application Cases

Core Feature Recap (All cases based on unique strengths of this model)

Flat F43 rectangular housing, measuring range 100~2000 mm;

2 SPDT passive relay contacts + 4…20mA analogue output + RS232 programmable interface;

Highlight: Single sensor integrates dual limit switching + continuous distance transmission. Passive relay contacts can directly drive contactors and audible/visual alarms. Flat housing fits confined mounting spaces; IP65 rated with built-in temperature compensation.

Memento important: This sensor is discontinued by the manufacturer. Alternatives are recommended for new projects. The below cases are proven historical applications.

Cse 1 | Wastewater Treatment: Level Monitoring & Pump Control for Open Settling Tank

Conditii de munca

Open regulating tank in small wastewater treatment plant with surface foam and high humidity. Requirements:

① Continuous level signal transmitted to PLC via 4–20mA;

② Low-level pump start, high-level pump stop (two relays directly control contactors to reduce PLC point consumption);

③ Limited installation space above tank guardrail, cylindrical sensors cannot be fitted.

Schema de implementare

Sensor installed horizontally with downward tilt above the tank, avoiding severe foam zones.

Releu 1: High level limit (1.6 m) → Trigger to stop drainage pump

Releu 2: Low level limit (0.4 m) → Trigger to activate water inlet

4–20mA signal sent to central control for real-time liquid level display

RS232 used on-site to calibrate measuring range and hysteresis, suppressing frequent fluctuation caused by water ripples.

Reason for Model Selection

Flat F43 housing compatible with narrow mounting brackets; Passive relays drive contactors directly without additional auxiliary relays. Ultrasonic measurement immune to water colour and mild foam.

Risk Notes

Thick foam absorbs ultrasound; proper mounting tilt required. Blind zone of 100 mm prevents low-level alarm setup near tank bottom.

Caz 2 | Plastic Extrusion Industry: Residual Roll Diameter Monitoring for Film / Nonwoven Web

Conditii de munca

Continuous unwinding of raw material rolls on cast film production line. Control system requirements:

  1. Real-time roll outer diameter measured; 4–20mA signal sent to tension controller for automatic unwinding torque regulation;
  2. Dual limit: Low material pre-warning + complete roll depletion safety shutdown.

Schema de implementare

Sensor mounted laterally on machine frame, aligned horizontally with roll outer surface; 0.1~2m measuring range matches maximum roll diameter.

Releu 1: Minimum roll diameter reached (pre-warning) → Audible & visual alarm for material preparation

Releu 2: Roll diameter hits minimum limit → Full production line safety shutdown

Continuous 4–20mA analogue distance output for roll diameter conversion and closed-loop tension control.

Selection Advantage Comparison

Conventional transistor-output sensors rely on PLC logic for dual alarm functions. Built-in relays enable direct wiring to alarm circuits for legacy retrofit projects without modifying PLC programs.

Operation Tip

Surface wrinkles and web vibration cause signal fluctuation; configure sufficient measurement hysteresis via software.

Caz 3 | Logistics Conveyor Line: Pallet Height Detection & Dual Position Limit

Conditii de munca

Roller conveyor for automated warehouse transporting wooden / plastic pallets. Photoelectric sensors prone to false triggering caused by dust and pallet gaps. Requirements:

① Confirm pallet arrival (near-point switch);

② Overheight pallet detection to prevent jamming in vertical lift;

③ Real-time pallet height data uploaded to WMS for cargo dimension verification.

Schema de implementare

Sensor side-mounted above conveyor channel:

Releu 1: Pallet arrival confirmation signal

Releu 2: Pallet overheight alarm, trigger conveyor emergency stop

4–20mA output of measured pallet height sent to upper system for cargo dimension validation.

Valoarea de bază

Slim flat housing embedded into narrow side space of conveyor. Ultrasonic detection unaffected by pallet holes and dust; passive relay contacts compatible with legacy safety circuits.

Caz 4 | Chemical Raw Material Hopper: Granular Level Monitoring (Plastic Pellets, Calcium Carbonate)

Conditii de munca

Open-top raw material hopper for small extruders. Heavy dust environment unsuitable for capacitive level switches. Requirements:

Low-level pre-warning, high-level full hopper shutdown, plus continuous level monitoring.

Schema de implementare

UC2000-F43 installed laterally at hopper top:

Releu 1: High material level → Stop feeding conveyor motor

Releu 2: Low material level → Start raw material feeding conveyor

4–20mA signal transmitted to central control for daily raw material consumption tracking.

Precauții

Severe dust clouds attenuate ultrasonic echo; avoid vertical installation facing falling material stream.

Caz 5 | Utilaje de constructii / AGV: Anti-collision Distance Warning System

Conditii de munca

Indoor factory Automated Guided Vehicle (AGV). Dual-stage collision protection required:

  1. Long-distance pre-warning (speed reduction); 2. Short-distance emergency stop; Continuous distance signal sent to on-board controller.

Schema de implementare

Flat-mounted F43 sensor on AGV outer body (cylindrical sensors protrude and risk collision damage). Measuring range 100~2000 mm:

Releu 1: 1.2 m detection distance → Vehicle speed reduction

Releu 2: 0.5 m danger distance → Emergency stop

4–20mA real-time distance signal for obstacle distance display on vehicle HMI.

Avantaj

Flat housing resists scratches from cargo. Independent safety relay circuit enables emergency stop even if main controller fails.

Caz 6 | Mașini de ambalare: Stacked Carton Height Monitoring

Conditii de munca

Palletising station for carton stacking. Verify stack height compliance and implement overheight protection.

Releu 1: Stack height reaches target → Robot executes transfer operation

Releu 2: Overheight stack → Equipment lock and alarm

Continuous 4–20mA height data for production data acquisition.

Suitable for rigid flat-surface targets such as cartons and turnover boxes.

Rezumat: Ideal Application Characteristics for This Model (Selection Checklist)

✅ Preferred Application Scenarios

  1. Confined installation space requiring flat rectangular housing; cylindrical ultrasonic sensors cannot be fitted
  2. Retrofit projects with existing control cabinets using passive contact signals; no intention to expand PLC I/O points
  3. Processes requiring dual limit switches + continuous analogue transmission integrated within one sensor
  4. Direct drive of 220 VAC audible/visual alarms or contactors (passive relay contacts)
  5. Environment with wide temperature fluctuation, praf și umezeală (built-in temperature compensation, IP65)

❌ Unsuitable Scenarios

  1. Applications with millions of frequent switching cycles (limited mechanical relay life; transistor-output sensors preferred)
  2. Targets made of thick / soft foam (ultrasound absorption leads to poor detection)
  3. Measurement distance below 100 mm (inherent blind zone)

 