PHOENIX TRIO-PS-2G/3AC/24DC/10 DIN Rail Mount Switching Power Supply

Comanda nr.: 2903154 Phoenix Contact TRIO POWER 2nd-generation three-phase DIN rail switching power supply with Push-in spring terminals. Designed for powering PLCs, sensors and actuators inside electrical control cabinets. Widely used in machine manufacturing, linii de producție automatizate, HVAC and hoisting equipment. Codul 2901354 often appears in industry documents as shorthand; the complete official part ...

  • Detalii despre produs

Comanda nr.: 2903154

Phoenix Contact TRIO POWER 2nd-generation three-phase DIN rail switching alimentare electrică with Push-in spring terminals. Designed for powering PLCs, sensors and actuators inside electrical control cabinets. Widely used in machine manufacturing, linii de producție automatizate, HVAC and hoisting equipment.

Codul 2901354 often appears in industry documents as shorthand; the complete official part number is 2903154.

✅ Model Definition

TRIO: TRIO POWER series industrial power supply

PS: Alimentare electrică

2G: 2nd Generation

3AC: 3-phase AC input

24DC: 24V DC ieșire

10: Rated output current 10A

📌 Key Technical Specifications

Intrare

Evaluat: 3×400~500V AC; capable of emergency operation with 2×400~500V AC two-phase supply

Interval de operare: 3×320~575V AC

Frecvenţă: 50/60Hz

Input current: 3×0.6A @400VAC

Ieșire

Evaluat: 24V DC /10A (240W)

Adjustable output: 24~28V DC

Dynamic Boost: 15A pentru 5 secunde (to handle inrush loads of motors and capacitors)

Clipoci & zgomot: ≤50mVpp

OVP overvoltage protection: Output clamped ≤30V DC

Mecanic & de mediu

Montare: DIN 35mm rail

Dimensiuni (L × H × D): 42 ×130 ×160 mm

Cablaj: Push-in screwless spring terminals

Temperatura de functionare: -25℃ ~ +70℃; derating 2.5%/K above 60℃

Eficienţă: >92%

Parallel operation: Supports parallel connection for capacity expansion and redundancy; series connection for voltage boosting

Protections: Supracurent, scurtcircuit, supratemperatura, output overvoltage

Semnal: Relay alarm contact (DC-OK signal)

📋 Certifications & Aplicații

Standarde: EN61010, UL, CE, PELV protective extra-low voltage

Aplicații tipice: Linii de producție automatizate, utilaje de ambalare, sisteme de transport, 24V power supply for control cabinets feeding PLC, DI/DO modules, sensors and solenoid valves

High MTBF, potrivit pentru 24/7 continuous industrial operation

⚠️ Selection & Note de înlocuire

  1. Model distinction: 2903154 is 3-phase 3AC; single-phase 1AC version is 2903149, do not mix them up
  2. Alternativă internă: Mean Well SDR-240-24, Delta DRP-240-24 (nota: no dynamic boost capability for inrush current)
  3. Redundancy solution: When paralleling two 2903154 unitati, use redundancy module such as QUINT-DIODE
  4. Instalare: Maintain ≥50mm vertical clearance at top and bottom for heat dissipation; units can be mounted side-by-side with zero horizontal clearance

🛠️ Troubleshooting Guide

POWER LED off: Check 3-phase L1/L2/L3 mains supply; loss of any phase may prevent startup; verify PE earth connection

Căderea tensiunii de ieșire / insufficient load capacity: Prioritize checking loose terminals, low input voltage and high-temperature derating

OK contact open: Output overcurrent / short circuit or internal overtemperature protection. Disconnect load and retest

Tripping on power-up due to inrush: Utilize boost feature and evaluate switching surge current

📦 HS Code for Export

8504401400 (Static converters, industrial switching power supply, for customs reference only, subject to local customs determination)

TRIO-PS-2G/3AC/24DC/10 (Comanda nr. 2903154)

Eficienţă: >92%

Condiție de testare: 400V AC input, full rated load

Additional Power Consumption Parameters

No-load power consumption: <1.1 W

Power loss at rated load: <22 W

Nota: This value is the nominal figure from Phoenix Contact official datasheet. Actual efficiency under light load (20%~50% load) will be slightly lower than the 92% full-load rating.

TRIO-PS-2G/3AC/24DC/10 (Comanda nr. 2903154)

Dimensiuni de gabarit (L × H × D): 42 mm × 130 mm × 160 mm

📌 Installation Clearance (Critical for cabinet layout)

Horizontal sides: Zero gap side-by-side mounting allowed at ambient ≤40℃; reserve 10mm side clearance when temperature approaches 70℃

Vertical: ≥50mm clearance at top and bottom (obligatoriu)

Sina de montare: Standard NS35 DIN rail (EN60715)

Greutate

Aproximativ. 1.1kg

Phoenix Contact TRIO-PS-2G Series Full Model List (TRIO POWER 2nd Generation, Terminale push-in)

Series common features: Montare pe șină DIN35, dynamic Boost (1.5×rated current for 5s), DC-OK relay alarm, parallel redundancy support, -25~+70℃, derating 2.5%/K above 60℃

1-phase Input 1AC (100~240VAC)|24VDC Output

ModelComanda nr.Evaluare de ieșireDimension W×H×D(mm)
TRIO-PS-2G/1AC/24DC/3/C2LPS290314724V 3A /72W30 ×130 ×115
TRIO-PS-2G/1AC/24DC/5290314824V 5A /120W36 ×130 ×115
TRIO-PS-2G/1AC/24DC/10290314924V 10A /240W42 ×130 ×160
TRIO-PS-2G/1AC/24DC/20290315124V 20A /480W65 ×130 ×160

3-phase Input 3AC (3×320~575VAC, rated at 3×400VAC)|24VDC Output (Your target model group)

ModelComanda nr.Evaluare de ieșireDimension W×H×D(mm)
TRIO-PS-2G/3AC/24DC/5290315324V 5A /120W36 ×130 ×115
TRIO-PS-2G/3AC/24DC/10290315424V 10A /240W42 ×130 ×160
TRIO-PS-2G/3AC/24DC/20290315524V 20A /480W65 ×130 ×160
TRIO-PS-2G/3AC/24DC/40290315624V 40A /960W120 ×130 ×160

1-phase Input 1AC|48VDC Output

ModelComanda nr.Evaluare de ieșireDimension W×H×D(mm)
TRIO-PS-2G/1AC/48DC/5290315948V 5A /240W42 ×130 ×160
TRIO-PS-2G/1AC/48DC/10290316048V 10A /480W65 ×130 ×160
  1. Common Matching Accessories (For cabinet integration)
  2. QUINT-DIODE/12-24DC/20 Redundancy diode module for dual power supply redundancy
  3. CBM E4 24DC/0.5-10A NO-R 4-channel 24V electronic circuit breaker (2905743)
  4. CBM E8 24DC/0.5-10A NO-R 8-channel electronic circuit breaker (2905744)

✅ Key Selection Guidelines

  1. Suffix C2LPS: Only available for the 3A single-phase variant with SIL capability; not required for standard automation projects
  2. 3AC three-phase models can run on two phases (L1/L2 only)
  3. Width reference: 3A=30mm; 5A=36mm; 10A=42mm; 20A=65mm; 40A=120mm, cabinet layout mainly depends on width

Phoenix Contact TRIO-PS-2G Series Certification List (Including TRIO-PS-2G/3AC/24DC/10, Order No.2903154)

All models in this series share the same certification package. Only the C2LPS suffix model has extra SIL0 capability; standard models are SIL=0

✅ Global Certifications

  1. CE (UE)

Low Voltage Directive LVD 2014/35/EU

EMC Directive 2014/30/EU

  1. UL / cULus (Listat UL)

UL508 (Industrial control equipment)

UL60950-1 (Information technology safety)

ANSI/ISA-12.12.01, Class I Division II Groups A/B/C/D (suitable for North American hazardous areas)

  1. IECEE CB Certificate (CB scheme, foundation for multi-country certification conversion)
  2. EAC Customs Union Certification (Rusia, Bielorusia, Kazakhstan and other EAEU markets)
  3. DNV GL Marine Certificate (Suitable for ship and offshore control cabinets)
  4. BIS (BIS license for India market)

✅ Environmental Compliance

RoHS (UE)

AJUNGE

WEEE compliant with waste electrical and electronic equipment directive

✅ Safety & Functional Standards (Standards ≠ Certificates; product compliance specifications)

IEC 60950-1: SELV Safety Extra-Low Voltage

ÎN 50178: PELV Protective Extra-Low Voltage

ÎN 60204-1: Safety of machinery electrical equipment (widely used for machinery)

ÎN 50121-4: Railway EMC standard

IEC 61508: SIL 0 (Standard models of this series; TRIO-PS-2G/1AC/24DC/3/C2LPS is specifically marked SIL0 functional safety)

Housing flammability: UL94 V0

✅ EMC Electromagnetic Compatibility Standards

ÎN 61000-6-1 / 6-2: Immunity (Rezidențial / medii industriale)

ÎN 61000-6-3 / 6-4: Radiated & conducted emissions

ÎN 61000-3-2: Harmonic current limits

📌 Selection Remarks

  1. Proiecte interne: No CCC certificate, not within mandatory 3C scope. CE for EU export, UL for North America, EAC for Russia/Central Asia, DNV for marine projects.
  2. SIL level: Standard TRIO-PS-2G cannot be used for SIL1 and above safety loops. If SIL higher level is required, select QUINT series SIL-rated power supplies.