Schneider GVAE11 Auxiliary Contact Block

GVAE11 is a 1NO + 1NC instantaneous auxiliary contact block of Schneider TeSys GV series. It is front-mounted and compatible with GV2/GV3 series motor circuit breakers. With a rated current of 2.5A and IP20 protection degree, it is used for status monitoring and signal feedback of motor control circuits, serving as a standard accessory for ...

  • Detalii despre produs

GVAE11 is a 1NO + 1NC instantaneous auxiliary contact block of Schneider TeSys GV series. It is front-mounted and compatible with GV2/GV3 series motor circuit breakers. With a rated current of 2.5A and IP20 protection degree, it is used for status monitoring and signal feedback of motor control circuits, serving as a standard accessory for motor control in industrial automation systems.

Segment de codSensDescriere
GVACategoria de produsAuxiliary contact block for GV series
EPoziția de montareMontare frontala, different from side-mounted models
11Configurare contact1 Deschis normal (NU) + 1 În mod normal închis (NC) instantaneous contacts with mechanical linkage

Definiție completă a modelului: GVAE11 = Schneider GV series, front-mounted, 1NO+1NC instantaneous auxiliary contact block

  1. Specificații tehnice de bază
CategorieSpecificațiiObservații
Caracteristici generale
Tip de produsInstantaneous auxiliary contact blockMechanically linked, operates synchronously with main contacts of circuit breaker
Configurare contact1NU + 1NC (Instantaneu)NO/NC status switches in sync with the main circuit of the circuit breaker
Compatible DevicesSchneider TeSys GV2/GV3 series motor circuit breakersCompatible with GV2L, GV2LE, GV2ME, GV2P, GV2RT, GV3L, GV3P and other models
Metoda de montareFront snap-on installationTool-free assembly & quick removal with precise positioning
Parametrii electrici
Tensiune nominală de funcționare24-240V AC, 24–60V DCSuitable for standard voltages of control circuits
Curent nominal de funcționare2.5O (Ith)Continuous current carrying capacity
Tensiune nominală de izolație690V șiComplies with insulation requirements for industrial control circuits
Rezistenta mecanica100,000 cicluri de operareHigh reliability for frequent operations
Rezistenta electrica100,000 cicluri de operare (AC-15 2.5A/240V)Meets long-term service requirements of control circuits
Tip terminalBorne cu șuruburiCopper wire cross-section: 0.5–1.5mm²; Tightening torque: 0.8–1.2Nm
Fizic & Parametrii de mediu
Grad de protectieIP20Prevents finger access to live parts
Dimensiuni (L × H × D)45 × 20 × 15mmStructură compactă, no extra installation space required for circuit breakers
Temperatura de operare-25℃ ~ +60℃Gamă largă de temperatură pentru medii industriale
CuloareGriMatches the appearance of GV series circuit breakers
CertificariCCC, UL, CSA, EACMulti-standard certifications for global application
Informații de comandă
Manufacturer Part No.GVAE11Official Schneider model
Cod de comandă standardGVAE11Original imported version
EAN Code3.38911E+12International universal commodity code
  1. Lista completă a modelelor (GVAE Series Auxiliary Contacts)
ModelConfigurare contactPoziția de montareCompatible DevicesMain Application
GVAE11NO or 1NC (Opțional)FaţăGV2/GV3 SeriesSimple status indication, single signal output
GVAE111NU + 1NCFaţăGV2/GV3 SeriesStandard status monitoring, output open/close signals simultaneously
GVAE202NUFaţăGV2/GV3 SeriesControl circuits requiring multiple NO signals
GVAE022NCFaţăGV2/GV3 SeriesControl circuits requiring multiple NC signals
GVAE141NU + 1NCLaturaGV2/GV3 SeriesSide mounting for space-limited installations
GVAE242NULaturaGV2/GV3 SeriesSide mounting for multiple NO signal demands
GVAE042NCLaturaGV2/GV3 SeriesSide mounting for multiple NC signal demands
  1. Modele de înlocuire & Comparația concurenților

4.1 Internal Schneider Replacements

Model originalModel de înlocuireDiferențeleScenarii de aplicare
GVAE11GVAE14Different mounting position (side mounting)Insufficient front space, side mounting required
GVAE11GV2ME + Built-in ContactsDesign integrat, no extra assembly neededNew equipment selection for integrated layout
GVAE11GV3P + Built-in ContactsUpgraded series with enhanced functionsHigh-standard applications requiring advanced protection

4.2 Comparație între concurenți între mărci

MarcaModelConfigurare contactCompatible DevicesPrincipalele diferențe
SchneiderGVAE111NU + 1NCGV2/GV3 SeriesPrecise mechanical linkage, Protectie IP20, high compatibility
ABBMS132-011NU + 1NCMS132 SeriesMontaj lateral, rated current 3A, pret similar
Siemens3RV2091-1A1NU + 1NC3RV20 SeriesMontare cu plug-in, rated current 2A, complete certifications
EatonPKZM0-AUX111NU + 1NCPKZM0 SeriesMontare frontala, rated current 2.5A, terminale cu arc
ChintNXC-A111NU + 1NCNXC SeriesEficient din punct de vedere al costurilor, reliable domestic alternative
  1. Medii de aplicație & Cazuri tipice

5.1 Aplicații recomandate

Motor Control Circuit: Feedback circuit breaker ON/OFF status for PLC/DCS system monitoring

Alarm System: Trigger audible and visual alarms via NC contacts when the circuit breaker trips

Interlock Control: Prevent simultaneous startup of multiple motors and realize sequence control

Monitorizare de la distanță: Transmit status signals to SCADA system for remote diagnosis

Safety Circuit: Form safety protection circuits together with emergency stop buttons

5.2 Aplicații nerecomandate

Main Circuit Usage: Rated current is only 2.5A, not applicable for motor main circuits

High-frequency Switching: Peste 1000 switching cycles per hour will shorten service life

Severe Electromagnetic Interference Environment: Additional shielding is required to avoid malfunction

Humid/Corrosive Environment: IP20 protection is insufficient; install extra enclosure or select higher protection grade products

5.3 Cazuri tipice de aplicare

Caz 1: Pump Unit Control in Wastewater Treatment Plant

Echipamente: 15kW submersible pump, GV2P32 circuit breaker + GVAE11 auxiliary contact

Configurare: NO contact of GVAE11 connected to PLC digital input module; NC contact connected to alarm circuit

Rezultat: Real-time monitoring of pump operating status, automatic alarm and event recording upon faults

Caz 2: Conveyor System in Automotive Production Line

Echipamente: 12 conveyor lines, each equipped with GV2P32 + GVAE11

Configurare: GVAE11 contacts linked with PLC to realize sequential startup and interlock protection for conveyors

Caracteristici: Mechanical linkage ensures accurate status feedback and reduces misjudgment of control systems

  1. Depanare & Maintenance Manual

6.1 Defecte comune & Soluții

Fenomen de eroareCauze posibileSoluții
No change of contact signals1. Improper installation of contact block1. Reinstall the block and ensure the clip is fully engaged
2. Damaged mechanical linkage2. Inspect linkage mechanism and replace damaged unit
3. Burned or oxidized contacts3. Clean or replace the contact block
4. Cablaj greșit4. Check wiring and confirm correct connection of NO/NC contacts
Contact welding1. Excessive current in control circuit1. Ensure control circuit current ≤ 2.5A
2. Overheating caused by frequent switching2. Reduce switching frequency or select higher-rated contacts
3. Arc erosion3. Replace with a new contact block
Interferența semnalului1. Control wires not separated from main wires1. Separate control wires from main wires (spacing ≥ 100mm)
2. No shielded cable used2. Use shielded cable with single-end grounding
3. Poor grounding3. Inspect and ensure reliable grounding
Instalare liberă1. Clip not fully locked1. Reinstall until a click sound is heard
2. Loosening caused by vibration2. Fit shock-absorbing pads or reinforce installation

6.2 Maintenance Procedures

  1. Inspecție zilnică (Săptămânal)

Check installation condition and ensure no looseness

Inspect terminals for overheating and looseness

Test contact switching to confirm synchronization with circuit breaker

  1. Întreținere de rutină (Fiecare 6 Luni)

Power off and remove dust on the contact block

Măsurați rezistența de contact (shall be ≤ 50mΩ)

Check flexibility of mechanical linkage

  1. Întreținere anuală

Replace frequently used contact blocks

Test insulation performance of control circuits

Retighten all electrical connections

6.3 Quick Diagnosis Tips

No signal? Check installation and linkage first.

Contact welded? Limit current and cut switching times.

Interferența semnalului? Separate wires, apply shielding and good grounding.

Loose fitting? Re-clip firmly and add shockproof measures for vibrating sites.

  1. Selecţie & Ghid de instalare

7.1 Reguli de selecție

Compatibilitate: Confirm matching with GV2/GV3 series circuit breakers; not applicable for other series

Configurare contact: Select 1NO+1NC (GVAE11), 2NU (GVAE20) or 2NC (GVAE02) according to control demands

Poziția de montare: Choose GVAE11 for front mounting, GVAE14 for side mounting

Potrivire curentă: Control circuit current shall not exceed 2.5A; select higher-specification products if overloaded

7.2 Note de instalare

Installation Sequence: Install circuit breaker first, then attach the contact block and fully lock the clip

Standard de cablare: Use 0.5–1.5mm² copper wires with tightening torque of 0.8–1.2Nm; avoid over-tightening

Clear Marking: Label NO/NC contacts to prevent wiring errors

Linkage Test: Manually operate the circuit breaker after installation to verify synchronous contact action

Măsuri de protecție: Install extra enclosures for dusty or humid environments

  1. Production Status & Soluții de înlocuire

Current Status of GVAE11: In production, no discontinuation plan (as of June 2026)

Upgrade & Opțiuni de înlocuire:

  1. Upgrade funcțional: GV3 series models with built-in contacts (no extra assembly, fewer fault points)
  2. Intelligent Upgrade: TeSys T series (with communication function for network-based status transmission)
  3. Alternativă internă: Compatible domestic GVAE11 models (lower cost with equivalent performance)